Loading...
HomeMy WebLinkAboutA021 - FLOOR AND ROOF ASSEMBLIESARCHITECTCLIENT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20022 NOVEMBER 11, 2020 # DESCRIPTION DATEMAGNOLIACONDOMINIUMSCARMEL, IN100% CONTRACT SET GC/CM UL DESIGN - UL L563 (1 HOUR) STC RATING - 50 MIN IIC RATING - 50 MIN A021FLOOR AND ROOFASSEMBLIESCEMENTITIOUS UNDERLAYMENT, 1 12" MINIMUM 38" SOUND MAT SHEATHING, REF. STRUCTURAL DWGS. FOR ADDITIONAL INFO. 24" OPEN WEB FLOOR TRUSS, REF. STRUCTURAL DWGS. FOR ADDITIONAL INFO. 12" RESILIENT CHANNEL @ 12" O.C. 58" TYPE 'C' GYPSUM BOARD SCALE: FLOOR ASSEMBLY F1 1 1/2" = 1'-0" 6 MIL UNDERSLAB VAPOR RETARDER COMPACTED SUB-GRADE, SEE CIVIL DWGS. CONCRETE SLAB PER STRUCTURAL DWGS. & STRUCTURAL SPECS FOR FINISH INFO. SCALE: FLOOR ASSEMBLY F2 1 1/2" = 1'-0" USE: SLAB ON GRADE USE: 1 HOUR RATED TYPICAL UPPER FLOOR SCALE: ROOF ASSEMBLY R1 1 1/2" = 1'-0" 60 MIL TPO ROOFING ADHERED/ FASTENED TO TAPERED INSULATION PER MANUFACTURER'S REQUIREMENTS POLYISOCYANURATE ROOF INSULATION TO ACHIEVE MINIMUM R-20 R-VALUE. ONE LAYER OF 58" TYPE 'C' GYPSUM BOARD RESILIENT CHANNELS @ 12" O.C. WOOD SHEATHING PER STRUCTURAL DWGS. ROOF TRUSS PER STRUCTURAL DWGS., TOP OF TRUSSES SLOPED TO ACHIEVE POSITIVE DRAINAGE USE: 1 HOUR RATED FLAT ROOF UL DESIGN - UL P522 (1 HOUR) NOTE: SEE A030 SERIES FOR UL ASSEMBLY INFORMATION. NOTE: ENSURE CEMENTITIOUS UNDERLAYMENT IS POURED UNDER TUB/SHOWERS AND IN DEAD AIR CAVITIES.SCHEDULED FINISH SCALE: ROOF ASSEMBLY R2 1 1/2" = 1'-0" USE: 1 HOUR RATED ROOF OVER ELEVATOR SHAFT UL DESIGN - GA-FC-5406 (1 HOUR) TWO LAYERS OF 58" TYPE 'C' GYPSUM BOARD 60 MIL TPO ROOFING ADHERED/ FASTENED TO TAPERED INSULATION PER MANUFACTURER'S POLYISOCYANURATE ROOF INSULATION TO ACHIEVE R-20 R-VALUE, TAPER TO ACHIEVE POSITIVE DRAINAGE WOOD SHEATHING PER STRUCTURAL DWGS. 2X WOOD FRAMING PER STRUCTURAL DWGS SCALE: FLOOR ASSEMBLY F3 1 1/2" = 1'-0" UL DESIGN - UL L563 (1 HOUR) STC RATING - 50 MIN IIC RATING - 50 MIN USE: 1 HOUR RATED UPPER FLOOR OVER GARAGE CEMENTITIOUS UNDERLAYMENT, 1 12" MIN. 38" SOUND MAT SHEATHING, REF. STRUCTURAL DWGS. FOR ADDITIONAL INFO. 24" OPEN WEB FLOOR TRUSS, REF. STRUCTURAL DWGS. FOR ADDITIONAL INFO. R-30 BLOWN-IN OR BATT FIBERGLASS INSULATION 12" RESILIENT CHANNEL @ 12" O.C. 58" TYPE 'C' EXTERIOR GRADE GYPSUM BOARD SCHEDULED FINISH SCALE: FLOOR ASSEMBLY B1 1 1/2" = 1'-0" 12" RESILIENT CHANNEL @ 12" O.C. 58" TYPE 'C' EXTERIOR GYPSUM BOARD INTERLOCKING WOOD DECK TILES OR DECKING WITH INTEGRATED DRAINAGE LAYER, SET DIRECTLY ON TPO FLEXIBLE TPO SHEET ROOFING SYSTEMSHEATHING, REF. STRUCTURAL DWGS. FOR ADDITIONAL INFO. USE: 1 HOUR RATED PRIVATE ROOF DECK NOTE: ENSURE CEMENTITIOUS UNDERLAYMENT IS POURED UNDER TUB/SHOWERS AND IN DEAD AIR CAVITIES. TAPERED POLYISOCYANURATE ROOF INSULATION TO ACHIEVE POSITIVE DRAINAGE TO INTERNAL ROOF DRAINS SCALE: FLOOR ASSEMBLY B2 1 1/2" = 1'-0" 18" OPEN WEB JOIST, REF. STRUCTURAL DWGS. FOR ADDITIONAL INFO. 12" RESILIENT CHANNEL @ 12" O.C. 58" TYPE 'C' GYPSUM BOARD INTERLOCKING WOOD DECK TILES OR DECKING WITH INTEGRATED DRAINAGE LAYER, SET DIRECTLY ON TPO FLEXIBLE TPO SHEET ROOFING SYSTEMSHEATHING, REF. STRUCTURAL DWGS. FOR ADDITIONAL INFO. USE: 1 HOUR RATED PRIVATE ROOF DECK TAPERED POLYISOCYANURATE ROOF INSULATION TO ACHIEVE POSITIVE DRAINAGE TO INTERNAL ROOF DRAINS SCALE: FLOOR ASSEMBLY B3 1 1/2" = 1'-0" 18" OPEN WEB JOIST, REF. STRUCTURAL DWGS. FOR ADDITIONAL INFO. 12" RESILIENT CHANNEL @ 12" O.C. 58" TYPE 'C' GYPSUM BOARD SYNTHETIC TURF WITH DRAINAGE COURSE (SYNTHETIC GRASS WAREHOUSE AS BASIS OF DESIGN) FLEXIBLE TPO SHEET ROOFING SYSTEMSHEATHING, REF. STRUCTURAL DWGS. FOR ADDITIONAL INFO. USE: 1 HOUR RATED PRIVATE ROOF DECK TAPERED POLYISOCYANURATE ROOF INSULATION TO ACHIEVE R-20 R-VALUE. POSITIVE DRAINAGE TO INTERNAL ROOF DRAINS UL DESIGN - UL P522 (1 HOUR)UL DESIGN - UL P522 (1 HOUR)UL DESIGN - UL P522 (1 HOUR) SOUND ATTENUATION BATT INSULATION 18" OPEN WEB JOIST, REF. STRUCTURAL DWGS. FOR ADDITIONAL INFO. MINIMUM R-38 BLOWN-IN OR BATT FIBERGLASS INSULATION INSTALLED AT TOP OF TRUSSES, ARCHITECT RECOMMENDS FILLING TRUSS SPACE WITH INSULATION. (ALT.: SPRAY INSULATION) PROVIDE VENTS TO ENSURE AIR CIRULATION OF FLOOR CAVITY, ALTERNATE IS TO FILL FLOOR CAVITY WITH INSULATION MINIMUM R-38 BLOWN-IN OR BATT FIBERGLASS INSULATION INSTALLED AT TOP OF TRUSSES, ARCHITECT RECOMMENDS FILLING TRUSS SPACE WITH INSULATION. (ALT.: SPRAY INSULATION) SCALE: FLOOR ASSEMBLY B4 1 1/2" = 1'-0" 18" OPEN WEB JOIST, REF. STRUCTURAL DWGS. FOR ADDITIONAL INFO. 12" RESILIENT CHANNEL @ 12" O.C. 58" TYPE 'C' EXTERIOR GYPSUM BOARD SYNTHETIC TURF WITH DRAINAGE COURSE (SYNTHETIC GRASS WAREHOUSE AS BASIS OF DESIGN) FLEXIBLE TPO SHEET ROOFING SYSTEMSHEATHING, REF. STRUCTURAL DWGS. FOR ADDITIONAL INFO. USE: 1 HOUR RATED PRIVATE ROOF DECK TAPERED POLYISOCYANURATE ROOF INSULATION TO ACHIEVE R-20 R-VALUE. POSITIVE DRAINAGE TO INTERNAL ROOF DRAINS UL DESIGN - UL P522 (1 HOUR) SCALE: ROOF ASSEMBLY R3 1 1/2" = 1'-0" 60 MIL TPO ROOFING ADHERED/ FASTENED TO TAPERED INSULATION PER MANUFACTURER'S REQUIREMENTS POLYISOCYANURATE ROOF INSULATION TO ACHIEVE MINIMUM R-20 R-VALUE. ONE LAYER OF 58" TYPE 'C' EXTERIOR GYPSUM BOARD RESILIENT CHANNELS @ 12" O.C. WOOD SHEATHING PER STRUCTURAL DWGS. ROOF TRUSS PER STRUCTURAL DWGS., TOP OF TRUSSES SLOPED TO ACHIEVE POSITIVE DRAINAGE USE: 1 HOUR RATED FLAT ROOF UL DESIGN - UL P522 (1 HOUR) MINIMUM R-38 BLOWN-IN OR BATT FIBERGLASS INSULATION (ALT.: SPRAY INSULATION 1 100% CONTRACT SET 11-11-2020 11 1 1 1 1 1 10/25/21