HomeMy WebLinkAboutA115 - ROOF PLANROOF PLAN LEGEND
1 TPO MEMBRANE ROOF - SEE WALL SECTIONS
AND ASSEMBLY SHEETS
CROSS HATCH REPRESENTS TAPERED
INSULATION AT 1/4" PER FOOT TO ACHIEVE
POSITIVE DRAINAGE.
METAL COPING ON PARAPET
48" X 48" ROOF HATCH WITH BUILT-UP CURB -
SEE SPECIFICATIONS FOR MORE
INFORMATION.
TPO SLIP-RESISTANT WALKWAY PAD - 30"
WIDE.
ROOF AND OVERFLOW DRAINS. SEE
PLUMBING DRAWINGS FOR MORE
INFORMATION.
#
2
3
4
5
6
GENERAL NOTES
1. ALL CEILING ARE TO BE 10'-0" A.F.F. UNLESS
NOTED OTHERWISE.
2. ALL UNITS ARE DESIGNED AS A117.1 ANSI TYPE
B UNITS. ALL UNITS ARE TO COMPLY WITH THE
ACCESSIBILITY CODES LISTED ON THE COVER
SHEET.
3. SEE MECHANICAL DRAWINGS FOR IN-WALL
WATER CONNECTIONS
4. CONTRACTOR TO VERIFY SIZE AND FRAMING
DIMENSIONS OF HVAC UNIT, BATHTUB DOORS
AND WINDOWS.
5. PROVIDE 1x2 PTD WOOD TRIM @ INTERIOR OF
ALL CLOSETS / UTILITY CLOSETS WHERE
STANDARD DOOR CASING WILL NOT FIT.
6. UNDERCUT ALL INTERIOR DOORS FOR
RETURN AIR 1".
7. BASE OF MIRROR REFLECTED SURFACE TO
BE INSTALLED 40" AFF MAXIMUM.
8. PROVIDE ELECTRICAL OUTLET IN KITCHEN
ISLAND SIDEWALL 6" BELOW COUNTERTOP AT
CENTERLINE OF WALL. SEE ELECTRICAL
DRAWINGS FOR MORE INFORMATION.
9. ALL WALLS / WALL SECTIONS BEHIND
PLUMBING FIXTURES TO BE 2X6 MINIMUM. -
FINISH WALLS TO ALIGN.
10. ALL SLOPED CONCRETE SURFACES ARE TO
RECEIVE BROOM FINISH.
11. ALL PENETRATIONS THROUGH RATED
ASSEMBLIES ARE TO BE PROTECTED AS PER
APPLICABLE UL SYSTEM LISTING.
A212
A212
A211
1
2
1
A2112
6
A301
1/4"/12" 1/4"/12"
1/4"/12" 1/4"/12"1/4"/12"1/4"/12" 1/4"/12" 1/4"/12"1/4"/12"1/4"/12" 1/4"/12"1/4"/12" 1/4"/12"1/4"/12" 4
6 66
3
3
3
1 11
1
2
2 22
22 ARCHITECTCLIENT GC/CM PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20022
NOVEMBER 11, 2020
100% CONTRACT SET
A115ROOF PLAN MAGNOLIACONDOMINIUMSCARMEL, INSCALE: 1/4" = 1'-0"1 ROOF PLAN
# DESCRIPTION DATE
10/25/21