HomeMy WebLinkAboutA400 - TYPICAL UNIT DETAILSEXTERIOR SIDE
EXTERIOR WALL FINISH
JOINT (TAPE AND COMPOUND)
THE EXTERIOR WALL FINISH AND THE SHEATHING ARE
THE ONLY SOLID WALL OR FLOOR ELEMENTS THAT
BRIDGE THE SEPARATION BETWEEN DWELLING UNITS
CONTINUOUS SEALANTCONTINUOUS SEALANT
JOINT (TAPE AND COMPOUND)
24" MIN.
SEAL DRYWALL TIGHT TO BASE AND FILL GAPS WITH
TAPE AND MUD OR NON-HARDENING SEALANT
NOTES:
1. LIGHT SWITCHES AND OUTLETS SHOULD BE OFFSET AT LEAST 24" AND BE
LOCATED IN SEPARATE STUD CAVITIES.
2. SOUND ATTENUATION INSULATION SHOULD EXTEND BEHIND ELECTRICAL
OUTLETS
SEAL DRYWALL TIGHT TO BOX
PENETRATION AND FILL GAPS WITH JOINT
COMPOUND/MUD. USE JOINT REINFORCING
TAPE AS NEEDED
WATER CLOSET
FILL THE GAP BETWEEN THE EDGES
OF THE FLOOR PENETRATION AND
THE WATER CLOSET FLANGE WITH
AN APPROVED MEMBRANE
PENETRATION FIRESTOP SYSTEM
WATER CLOSETS TO BE RESILIENTLY MOUNTED WHEN SERVED BY DRAINS
OR VENTS WHICH ARE INSTALLED WITHIN DEMISING ASSEMBLIES
SECTION VIEW
JOINT (TAPE AND
COMPOUND)
AT BOTH SIDES OF
WALL
SET RESILIENT CHANNELS ON EA.
SIDE OF THE WALL WITH STUD
LEG AS SHOWN AND MAX. 1.75
INCHES AWAY FROM WALL STUD,
THEN CONTINUE INSTALLING THEM
PER UL ASSEMBLY
REQUIREMENTS
UNIT SIDEUNIT SIDE
NON- HARDENING SEALANT
CONTINUOUS SEALANT
CONTINUOUS SEALANT
PROVIDE FIRE BLOCKING AT
ALL CEILING LINES
SEE 2/A311 FOR ADDITIONAL INFORMATION
PROVIDE PERIMETER ISOLATION FOAM STRIP @
ALL UNIT WALL TO FLOOR INTERSECTIONS.
CONTINUE TO FACE OF SILL PLATESECTION VIEW
SHEATHING PER STRUCTURAL DWGS
SOUND ISOLATION MAT
CEMETITIOUS UNDERLAYMENT
SCHEDULED FLOORING
GAP UNDER BASE BOARD
SCHEDULED BASE BOARD SHALL NOT
CONTACT FLOORING. DO NOT APPLY SEALANT
BETWEEN BASE AND FLOORING
SCHEDULED WALL, REF. ENLARGED UNIT PLANS
CONTINUOUS SEALANT
TOP OF COUNTER
3'-0" A.F.F.
REF. FLOOR PLANS FOR
WALL TYPES
WRAP BOX (5 SIDES) WITH 58"
TYPE 'X' GWB, TAPE ALL
JOINTS
SEMI-RECESSED FIRE
EXTINGUISHER CABINET
2 x WIDTH OF WALL FIRE
BLOCKING, TYP.
FLEXIBLE FLASHING (ON
EXTERIOR SHEATHING)
TOP STRAIGHT FLASHING
OVER VERTICAL STRAIGHT
FLASHING
WALL PENETRATION.
SEAL CONTINUOUS AROUND IT
AND FINAL EXT. WALL FINISH
VERT. STRAIGHT FLASHING
OVER HRZ. BOTTOM
STRAIGHT FLASHING
REFER TO LIGHTING
SCHEDULE FOR
ACTUAL DESIGN
CAULK ELECTRICAL
BOXES TO DRYWALL
NOTE:
1. LIMIT INSTALLATION OF
RECESSED CANS TO FURRED
DOWN LOCATIONS AT UNIT
SEPARATIONS TO AVOID
COMPROMISING
FIRE AND SOUND RATINGS.
SEAL BATHROOM DRAIN
PENETRATION
FIRE-RETARDENT
SEALANT,
ENTIRE PERIMETER OF
COLLAR
NON-COMBUSTABLE FLUE
COLLAR (SHEET METAL)
HVAC UNIT
PROVIDE SEALANT (FIRE-RETARDANT
AT RATED CONSTRUCTION) AT
PERIMETER OF COLLAR BEHIND ALL
REGISTER/RETURN AIR BOOTS,
TYPICAL.
HVAC DUCT
GRILL COVER - SEE MECH
DRAWINGS
UNIT TYPICALDETAILSA400
SCALE:
01 AT INTERIOR WALLS
TUB/SHOWER
1 1/2" = 1'-0"
58" TYPE 'X' GYPSUM WALL BOARD
SHALL EXTEND TO FLOOR LEVEL.
SCALE:
07 AT DEMISING ASSEMBLY
ELECTRICAL PENETRATION
1 1/2" = 1'-0"
SCALE:
08 AT DEMISING ASSEMBLY
PLUMBING PENETRATION
1 1/2" = 1'-0"
SCALE:
03 AT DEMISING FLOOR ASSEMBLY
PLUMBING PENETRATION
1 1/2" = 1'-0"
SCALE:
09 AND EXTERIOR WALL
INTERSECTION UNIT DEMISING WALL
1 1/2" = 1'-0"
SCALE:
10 ATTACHMENT TO CEILING AND FLOOR
DEMISING WALL
1 1/2" = 1'-0"
SCALE:
04 FLOOR TO WALL CONNECTION
TYPICAL VINYL PLANK
3" = 1'-0"
BATHTUB / SHOWER SURROUND
SCALE:
02 SECTION DETAIL
KITCHEN ISLAND
1 1/2" = 1'-0"
SCHEDULED UNIT
KITCHEN COUNTERTOP
PAINT GRADE
WOOD TRIM
SCHEDULED UNIT
BASE BOARD
UNIT CASEWORK PER
UNIT INTERIOR ELEVATIONS
AND UNIT ENLARGED
FLOOR PLANS
SCALE:
05 DETAIL
FIRE EXTINGUISHER
1 1/2" = 1'-0"
WG1b
12"ARCHITECTCLIENT PROJECT DRAWING TITLE SEAL SHEET PROJECT INFO REVISIONS20022
NOVEMBER 11, 2020
# DESCRIPTION DATEMAGNOLIACONDOMINIUMSCARMEL, IN100% CONTRACT SET GC/CM
58" GYPSUM GREEN BOARD TO STOP
AT TOP OF TUB OR SHOWER PAN. USE
12" CEMENT BACKERBOARD IN LIEU OF
GYPSUM GREEN BOARD AT TILED
SHOWERS.
1 100% CONTRACT SET 11-11-2020
SCALE:
06 PENETRATION DETAIL
TYPICAL SEALANT @
1 1/2" = 1'-0"
SCALE:
11 BOX SEALING DETAIL
LIGHT FIXTURE ELECTRICAL
1 1/2" = 1'-0"
SCALE:
12 PENETRATION (TUB)
BATHROOM DRAIN
1 1/2" = 1'-0"
SCALE:
13 PENETRATION SEALING DETAIL
HVAC RATED
1 1/2" = 1'-0"
SCALE:
14 PENETRATION SEALING DETAIL
HVAC RATED
1 1/2" = 1'-0"
WG5a
WG5a
2
2
2
2 WG5aWG5a 2
2
REVISION 01 01-15-2021
10/25/21