P403 WATER ENLARGED VIEWS
Level 02 12' - 0" SECOND FLOOR EL: 12'-0" 3/4"ø CW 3/4"ø HW 3/4"ø HWR 1"ø G 1"ø G 1"ø G 1 1/4"ø G1"ø G 1"ø G4"ø4"ø 3"ø3"ø3/4"ø HW 3/4"ø CW 3/4"ø HWR WATER SUBMETER ET-1 1 1/4"ø CW GAS VALVE RELIEF VALVE RELIEF VALVE 1"ø GGWH-1 WATER SUBMETER WATER IN GAS IN 3/4"ø CW1 1/4"ø CW3/4"ø HW 3/4"ø HW R 3/4"ø 1"ø G1"ø G 1 1/4"ø G1"ø G3"ø 3"ø 3"ø 4"ø4"ø3"ø1"ø HW3/4"ø HW 3/4"ø HW R 3/4"ø HWR1"ø GGWH-1 ET-1 Level 01 0'- 0" FIRST FLOOR EL: 0' -0" 2"ø CW Water Meter Spacer 2" Gate Valve 2" Gate Valve BFP-1 2"ø CW 2"ø CW 2"ø SANRELIEF DRAIN2"ø CWDOMESTIC WATERSERVICE INTO BUILDINGLevel 01 0'- 0" FIRST FLOOR EL: 0' -0" BP-1 2" Ball Valve 2" Ball Valve 2" Ball Valve WATER SOFTENER BYPASS Hose Bib Shut Off 3/4" Ball Valve Boiler Drain for System Drain Down Building Shut Off2"ø3/4"ø 3/4"ø RI G EEIS PE60860351 No.REENIGNELANOISSEFORPDOUGLAS.RMOO RET R NNDIA A STATE OF DEMOORE ENGINEERING SERVICES, INC. 6340 LaPas Trail Indianapolis, IN 46268 Phone (317) 291-1052 FAX (317) 298-2729 ARCHITECTCLIENT PROJECT DRAWING TITLE SHEET PROJECT INFO REVISIONS20022 # DESCRIPTION DATEMAGNOLIACONDOMINIUMS126TH & RANGELINERD CARMEL, IN100% Contract Set GC/CM SEAL 1/15/2021Revision 1 2 10/07/2020 P403 WATER ENLARGED VIEWS1 1/2" = 1'-0"2 Typical Water Heater Room 1 Typical Water Heater Room 1 1/2" = 1'-0"3 Meter and Backflow 1 1/2" = 1'-0"4 Pump and Softener Bypass 1 2 Powered by TCPDF (www.tcpdf.org) 10/25/21