IREVISIONS:DRAWING COMPLETION DATE:4820 Buttonwood CrescentARCHITECT AIAGORDON CLARKIndianapolis, Indiana 46228Phone: 317 255-2546317 252-5573Fax: GClark4820@aol.comCONVENIENCE STORE / FOOD MARTVILLAGE OF WEST CLAYCARMEL, INDIANASOUTHWEST CORNER OFHARLESTON STREET AND TOWNE ROADOCTOBER 14, 2021
FOR PERMITTING AND CONSTRUCTIONEPDM ROOFING. SEE SPECIFICATIONS
4" RIGID INSULATION
CORRIGATED STEEL ROOF DECK
OPEN WEB STEEL JOISTS
30 K 90 / 50
24" O.C.
WMP-10 R-30 VINYL LINED INSULATION
ROOF EQUIPMENT SCREENING
SEE SPECS. AND OTHER DRAWINGS
LAY-IN CEILING AT 10'-0" AFF
BOND BEAM WITH TWO
CONTINUOUS #5 REBARS
R-19 FIBERGLASS
INSULATION
3 5/8" STEEL STUDS
SPECIFICATIONS AND REQUIREMENTS FOR
STOREFRONT AND ENTRANCE SYSTEMS:
This section includes windows and entrance systems.
Basis of Design and Standards:
Aluminum Framing Systems: Kawneer TRIFAB VG (VERSA GLAZE) 451,
(2” sight line)
Aluminum Entrance Doors: Kawneer 190 Narrow Stile with Finger Guards
Note: Interior and one exterior door are part of this work.
Frame Depth:4 ½”
Glass and Glazing:
Outside glazing: 1” insulated low E glazing (1/4” outside, ½” spacer, ¼”
inside glass.)
Interior glazing: ¼” tempered clear plate
Glaze to front.
Glazing materials shall be compatible with aluminum and shall be as
recommended by manufacturer.
Glazing methods
o Exterior: Elastomeric gasket and in accordance with
manufacturer’s standards.
o Interior: Snap-in type 0.062 aluminum glazing beads and a
compression wedge of dense elastomer.
Operable windows:
o Provide and install two (2) operable windows for ventilation
compatible with the storefront system. Provide shop drawings or
cut sheets for architect and/or owner review.
Stick fabrication, manufacturer’s standard parts and entrance systems.
Include SSG/Weather seal option
Include end-dams with sill flashing. Use concealed flashing, minimum 26 gage
dead-soft stainless steel, or .026” minimum extruded aluminum of alloy and type
compatible with adjacent materials.
Perimeter anchors: Aluminum.
All storefront metal to be clear anodized finish.
Exterior framing to be set in head receptor, bottom sill starter, set in caulk bed.
All framing to include perimeter caulking on interior and exterior sides.
Include all required sealants, with products selected for their intended use and
adjacent materials.
Use tempered glass where required by state and local codes and ordinances.
G.C. to provide solid wood blocking at heads/jambs for frame anchoring.
Head lintel to be self supportive, non-load-bearing, by G.C.
Field Measurements: G.C. shall advise storefront sub-contractor when field
measurements may be made in a timely fashion. Verify by field measurements
prior to fabrication. Keep a record of field measurements.
Storage:
Store products in manufacturer’s packaging unopened until ready for installation.
Store protected from soaking water, corrosion, and other damaging causes.
Entrance Systems:
Rails affixed to stiles utilizing threaded through-bolt with concealed
fasteners.
Water-rated bumper threshold, ADA compliant.
Hardware:
4” butt hinges, 1 or 2 pair determined by specified height.
3 point locking mechanism on active leaf, 2 point on inactive leaf.
Keyed cylinder with thumb-turn on interior of active leaf.
ADA compliant panic strike with tubular push/pull.
Glazing: Wet seal exterior with structural silicone per manufacturer’s
written instructions.
Weather Stripping: Manufacturer’s specified weather stripping installed
strictly in accordance with manufacturer’s written instructions.
Installation:
Installation shall be complete as intended for building use.
Protect work from damage during entire course of construction.
Install all storefront and entrance units plumb, level, and true to line without warp
or rack of frames or sash with manufacturer’s prescribed tolerances.
Weathertight Construction: Install sill members and other members in a bed of
sealant or with joint filler or gaskets, to provide weathertight construction.
Coordinate installation with wall flashings and other components of construction.
Provide support and anchor in place.
Provide all required accessories for a complete installation.
Adjust swing doors for operation in accordance with manufacturer’s written
instructions.
Clean in accordance with manufacturer’s written instructions. Remove temporary
coverings and protection of adjacent work areas. Repair or replace damaged
installed products.
Warranties:
Frames Warranty: Two (2) years from Date of Substantial Completion.
Submit manufacturer’s standard written warranty for Owner’s acceptance.
Insulating Glass: Warranted to be free from defects (excluding breakage) for a
period of five (5) years.
Submit standard written warranty for Owner’s acceptance.
EXTERIOR TILE WATERTABLE
COLOR: BLUE AS SELECTED
BY ARCHITECT
STANDARD FACE BRICK
ALUM. ANODIZED STOREFRONT
2'-6"7'-3"EXTERIOR TILE LEDGE
COLOR: BLUE AS SELECTED
BY ARCHITECT
SOLDIER COURSE
STD. 8" CMU'S
STANDARD FACE BRICK
BOND BEAM
#5 REBAR CONTINUOUS
TOP OF
MASONRY
16'-0" AFF
4" CONCRETE FLOOR SLAB
MINUMUM TOTAL OF 4'-0"
RIGID INSULATION 2" THICK
TYPICAL ALL EXTERIOR FOUNDATIONS
2'-4"1'-0"2'-8"TWO CONTINUOUS #5 REBARS
12" SOLID CMU'S
TYPICAL AT BRICK CONDITIONS
SOLID 8" CMU
14'-8" TOM
CONTINUOUS FLASHING PER MASONRY
STANDARDS
EXTERIOR TILE LEDGE
COLOR: BLUE AS SELECTED
BY ARCHITECT
STANDARD FACE BRICK
STANDARD FACE BRICK
STD. 8" CMU'S
SOLDIER COURSE
TILE DIAMOND PANEL
STEEL STUD FURRING
HORIZONTAL REINF.
EACH THIRD CMU COURSE
EXTERIOR TILE LEDGE
COLOR: BLUE AS SELECTED
BY ARCHITECT
EXTERIOR TILE WATERTABLE
COLOR: BLUE AS SELECTEDBY ARCHITECT
STANDARD FACE BRICK
OPEN WEB STEEL JOISTS
30 K 90 / 50
24" O.C.
TOP OF
MASONRY
16'-0" AFF
14'-8" TOM
2'-6" AFF TOM
7'-3" AFF TOM
10'-0 1/2" TOM
HOG-BACK OR CRICKET SLOPED
TO SCUPPER. SEE ROOF PLAN.
HORIZONTAL REINFORCING
EVERY 2'-0" VERTICALLY
STANDARD MASONRY BRICK-LEDGE
FLASHING
MINUMUM TOTAL OF 4'-0"
RIGID INSULATION 2" THICK
TYPICAL ALL EXTERIOR FOUNDATIONS
TWO CONTINUOUS #5 REBARS
12" SOLID CMU'S
TYPICAL AT BRICK CONDITIONS
SOLID 8" CMU
SCALE: 1" = 1'-0"
1 SECTION THRU SOUTH STOREFRONT WINDOWS
SCALE: 1" = 1'-0"
SECTION THRU TYP.
NORTH WALL
1'-3"
1'-3"
MAIN BEAM CL
MAIN BEAM CL
A3.4A3.4A3.4
2