HomeMy WebLinkAboutVWC CONV STORE15 A4.1 10-14-2021I
I
IREVISIONS:DRAWING COMPLETION DATE:4820 Buttonwood CrescentARCHITECT AIAGORDON CLARKIndianapolis, Indiana 46228Phone: 317 255-2546317 252-5573Fax: GClark4820@aol.comCONVENIENCE STORE / FOOD MARTVILLAGE OF WEST CLAYCARMEL, INDIANASOUTHWEST CORNER OFHARLESTON STREET AND TOWNE ROADOCTOBER 14, 2021
FOR PERMITTING AND CONSTRUCTIONSTEEL JOISTS AND GIRDERS
PART 1 - GENERAL
1.1 SUMMARY
A. THIS SECTION INCLUDES THE FOLLOWING:
1. OPEN-WEB, K-SERIES STEEL JOISTS.
2. JOIST GIRDERS.
1.2 SUBMITTALS
A. SHOP DRAWINGS: PROVIDE SHOP DRAWINGS OF ADEQUATE DETAIL
FOR ARCHITECT TO REVIEW PROPOSED INSTALLATION.
1.3 QUALITY ASSURANCE
A. MANUFACTURER QUALIFICATIONS: A FIRM EXPERIENCED IN
MANUFACTURING JOISTS SIMILAR TO THOSE INDICATED FOR THIS
PROJECT AND WITH A RECORD OF SUCCESSFUL IN-SERVICE
PERFORMANCE.
1. MANUFACTURER MUST BE CERTIFIED BY SJI TO MANUFACTURE
JOISTS COMPLYING WITH SJI STANDARD SPECIFICATIONS AND
LOAD TABLES.
B. WELDING (IF USED): QUALIFY PROCEDURES AND PERSONNEL
ACCORDING TO AWS D1.1, "STRUCTURAL WELDING CODE--STEEL," AND
AWS D1.3, "STRUCTURAL WELDING CODE--SHEET STEEL."
1.4 DELIVERY, STORAGE, AND HANDLING
A. DELIVER, STORE, AND HANDLE JOISTS AS RECOMMENDED IN SJI'S
"SPECIFICATIONS."
PART 2 - PRODUCTS
2.1 MATERIALS
A. STEEL: COMPLY WITH SJI'S "SPECIFICATIONS" FOR CHORD AND WEB
MEMBERS.
2.2 PRIMERS
A. PRIMER: SSPC-PAINT 15, TYPE I, RED OXIDE; FS TT-P-636, RED OXIDE;
OR MANUFACTURER'S STANDARD SHOP PRIMER COMPLYING WITH
PERFORMANCE REQUIREMENTS OF EITHER OF THESE RED-OXIDE
PRIMERS.
2.3 STEEL JOISTS
A. MANUFACTURE STEEL JOISTS ACCORDING TO SJI'S "SPECIFICATIONS,"
WITH STEEL-ANGLE TOP- AND BOTTOM-CHORD MEMBERS, AND AS
FOLLOWS:
1. MANUFACTURE K-SERIES STEEL JOISTS ACCORDING TO
"STANDARD SPECIFICATIONS FOR OPEN WEB STEEL JOISTS, K-
SERIES," WITH STEEL-ANGLE TOP- AND BOTTOM-CHORD
MEMBERS, UNDERSLUNG ENDS, AND PARALLEL TOP CHORD.
B. COMPLY WITH AWS REQUIREMENTS AND PROCEDURES FOR SHOP
WELDING, APPEARANCE, QUALITY OF WELDS, AND METHODS USED IN
CORRECTING WELDING WORK.
2.4 JOIST GIRDERS
A. MANUFACTURE JOIST GIRDERS ACCORDING TO "STANDARD
SPECIFICATIONS FOR JOIST GIRDERS," IN SJI'S "SPECIFICATIONS,"
WITH STEEL-ANGLE TOP- AND BOTTOM-CHORD MEMBERS; WITH END
AND TOP-CHORD ARRANGEMENTS INDICATED.
B. COMPLY WITH AWS REQUIREMENTS AND PROCEDURES FOR SHOP
WELDING, APPEARANCE, QUALITY OF WELDS, AND METHODS USED IN
CORRECTING WELDING WORK.
2.5 JOIST ACCESSORIES
A. BRIDGING: PROVIDE BRIDGING ANCHORS AND NUMBER OF ROWS OF
HORIZONTAL OR DIAGONAL BRIDGING OF MATERIAL, SIZE, AND TYPE
REQUIRED BY SJI'S "SPECIFICATIONS" FOR TYPE OF JOIST, CHORD
SIZE, SPACING, AND SPAN.
B. BRIDGING: SCHEMATICALLY INDICATED. DETAIL AND FABRICATE
ACCORDING TO SJI'S "SPECIFICATIONS."
C. SUPPLY MISCELLANEOUS ACCESSORIES, INCLUDING SPLICE PLATES
AND BOLTS REQUIRED BY JOIST MANUFACTURER TO COMPLETE JOIST
INSTALLATION.
PART 3 - EXECUTION
3.1 INSTALLATION
A. DO NOT INSTALL JOISTS UNTIL SUPPORTING CONSTRUCTION IS IN
PLACE AND SECURED.
B. INSTALL JOISTS AND ACCESSORIES PLUMB, SQUARE, AND TRUE TO
LINE; SECURELY FASTEN TO SUPPORTING CONSTRUCTION
ACCORDING TO SJI'S "SPECIFICATIONS," JOIST MANUFACTURER'S
WRITTEN RECOMMENDATIONS, AND REQUIREMENTS IN THIS SECTION.
C. BOLT JOISTS TO SUPPORTING STEEL FRAMEWORK USING CARBON-
STEEL BOLTS, UNLESS OTHERWISE INDICATED.
END OF SECTION 05210
COLUMN PER PLAN
3/4"x10"x10" @ TS 6x6
BASE PLATE
1 1/2"1 1/2"
PLANELEVATION
1 1/2"1 1/2"BOLTS (A36)
(4) - 3/4"Ø ANCHOR
2" NON-SHRINKGROUT6" PROJ.COLUMN BASE
TYPICAL TUBE
SCALE: 1/4" = 1'-0"
#5 REBARS 12" O.C.2'-8"1'-0""L" #5'S IN EACH CORNER
OF PIER
4" CONCRETE SLAB
SEE SPECS. AND DETAILS
6"x6"x3/8" TUBE STEEL COLUMNS
(TYPICAL ALL)
SCALE: 1/4" = 1'-0"
TYPICAL COLUMN FOOTER
4'-0"
#5 REBARS 12" O.C.
TYPICAL ALL
"L" #5'S IN EACH CORNER
OF PIER
24" SQUARE PIER
4'-0"4'-0"STEEL FRAMING GENERAL NOTES:
MISCELLANEOUS:
Any additional work such as canopies, overhangs, sunshades or other
architectural features requiring structural decisions and not certified by Gordon
Clark must be indicated on shop drawings certified by a professional engineer
licensed to practice in the state of Indiana.
STRUCTURAL STEEL:
Structural steel detailing, fabrication and erection shall conform to the AISC
“Specification for the Design, Fabrication, and Erection of Structural Steel for
Buildings” latest edition with amendments, and the current AISC “Code of
Standard Practice for Steel Buildings”.
Structural steel tubes and pipe shapes shall conform to ASTM A500 Grade 46.
Structural steel rolled shapes, except plates and angles, shall conform to
ASTM A500 Grade 45.
Anchor bolts shall conform to ASTM F1554 Grade 36, unless otherwise noted.
Erector shall maintain adequate temporary bracing in each direction until
diaphragm and lateral brace construction is completed.
Unless otherwise noted, bolted connections for structural steel members shall
be made with ¾” diameter high strength steel bolts conforming to ASTM A325.
Except as noted, bolted connections shall be tightened to the snug tight
condition. Bolted connections where used in brace elements shall be tightened
using the turn-of-nut condition. Connections shall conform to the “Specification
for Structural Joints using ASTM A325 or A490 Bolts”, approved by the
Research Council on Structural Connections of the Engineering Foundation.
Welding procedures shall conform to the latest edition of the American Welding
Society’s “Structural Welding Code for Steel ANSI / AWS D1.1”, Reinforcing
Steel ANSI / AWS D1.4, and Steet Steel ANSI / AWS D1.3”.
Splicing of structural steel members where not detailed on the Contract
Documents is prohibited without the prior approval of the architect as to
location, type of splice and connection to be made.
Surfaces within 2 inches of any field weld shall be free of materials that would
prevent proper welding or produce toxic fumes while welding is being done.
Beams shall be cambered upward unless indicated otherwise.
Structural steel shall be shop-painted with a rust inhibiting primer. Steel that
shall be exposed to the weather shall receive one additional finish coat.
Field measure steel prior to fabrication as often as possible.
Shop drawings shall be reviewed by the Architect for design concepts
expressed in the Contract Documents only. The Contractor shall be
responsible for all dimensions, accuracy, and fit of work.
DESIGN DATA:
The building structural has been designed in accordance with the 2012 Indiana
Building Code.
Roof Loads:
Dead Load: 13 psf
Live Load: 20 psf
Ground Snow Load (Pg): 20 psf
- Flat Roof Snow Load: (Pf): 20 psf
- Snow Exposure factor (Ce): 1.0
- Snow Load Importance Factor: (ls): 1.0
- Thermal Factor (Ct): 1.0
Wind Design Data:
Basic Wind Speed (3 second gust): 115 mph ULT; 90 mph Nominal
Risk Category: II
Wind Exposure Category: C
Internal Pressure Coefficient: +/- .18
Base Wind Pressure: 18.8 psf
Seismic Design Data:
Risk Category: II
Seismic Site Class: D
0.2 sec. Mapped MCE Ground Motion (Ss): 0.148
1.0 sec. Mapped MCE Ground Motion (S1): 0.082
0.2 sec. 5% Damped Spectral Response Acceleration (Sds): 0.157
1.0 sec. 5% Damped Spectral Response Acceleration (Sd1): 0.131
Seismic Design Category: B
Basic structural and seismic resisting system: Ordinary System Not
Specifically Detailed for Seismic Resistance.
Analysis Procedure: Equivalent lateral force procedure
Response Modification Coefficient ®: 3
Seismic response Coefficient (Cs): .052
Slab Capacity:
Post Load = 16K (Min. Base = 4” x 3”)
Uniform Loading = 1.0 K/sf
Back-to-Back Post Load = 12K (Min. Base = 4”x3”)
A4.1