Loading...
HomeMy WebLinkAboutVWC CONV STORE22 P1.1 10-14-2021I I IREVISIONS:DRAWING COMPLETION DATE:4820 Buttonwood CrescentARCHITECT AIAGORDON CLARKIndianapolis, Indiana 46228Phone: 317 255-2546317 252-5573Fax: GClark4820@aol.comCONVENIENCE STORE / FOOD MARTVILLAGE OF WEST CLAYCARMEL, INDIANASOUTHWEST CORNER OFHARLESTON STREET AND TOWNE ROADOCTOBER 14, 2021 FOR PERMITTING AND CONSTRUCTION6" TO PUBLIC SEWER BACKFLOW PREVENTER BUILDING CLEAN OUT HAND SINK HAND SINK 4" 2" ADA WC ADA WC ADA LAV ADA LAV ADA UR C.O. 2" 2" 2" 2" FD FD 4" 4" 2" ENDURA XL100 M RATED GREASE INTERCEPTOR BELOW SLAB 3" 3" FD 2" 2" 3" 3 COMPARTMENT COMMERCIAL SS SINK MOP SINK ELECTRIC WATER HEATER ABOVE ON STEEL RACK 3" 3" SCALE: 1/4" = 1'-0" SANITARY SEWER PLAN FLOOR SINK FOR BEVERAGE DISPENSER. VERIFY LOCATION WITH OWNER PRIOR TO INSTALLATION. FLOOR SINK FOR ICE MACHINE. VERIFY LOCATION WITH OWNER PRIOR TO INSTALLATION. 2"2" 2" 4"4" 4" 4" 4" CONDENSATE FOR FREEZER COMPRESSOR PLUMBING – GENERAL NOTES AND SPECIFICATIONS: PLUMBING CONTRACTOR SHALL CONFIRM SIZES OR ESTABLISH SIZES OF WASTE, VENT AND SUPPLY AS REQUIRED TO MAKE A COMPLETE AND WORKING SYSTEM. THE SCOPE OF THE PLUMBING WORK INCLUDES FURNISHING, INSTALLING TESTING AND WARRANTY OF ALL PLUMBING WORK SHOWN ON THE PLUMBING DRAWINGS. THE PLUMBING CONTRACTOR ACKNOWLEDGES THAT HE IS AWARE THAT PLUMBING DRAWINGS ARE SCHEMATIC IN NATURE AND DO NOT SHOW ALL EQUIPMENT OR FITTINGS REQUIRED. LOCATIONS ARE DIAGRAMMATIC. PLUMBING CONTRACTOR SHALL ADJUST LOCATION OF PIPING AS REQUIRED. CONFIRM DETAILED LOCATIONS WITH OWNER IF CRITICAL. THIS PROJECT SHALL BE COMPLETE, OPERATIONAL AND MEET CURRENT STATE AND LOCAL CODES AND ORDINANCES IN EVERY WAY. THE CURRENT CODE IS THE 2012 INDIANA PLUMBING CODE (2006 INTERNATIONAL PLUMBING CODE WITH 2012 INDIANA AMENDMENTS) COORDINATE WORK WITH OTHER TRADES AND CONFIRM THAT CLEARANCES AND FITTING REQUIREMENTS ARE KEPT. MATERIALS AND WORKMANSHIP: ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND FIRST QUALITY. PROVIDE ALL NECESSARY CLIPS, HANGERS, FASTENERS, AND OTHER DEVICES REQUIRED FOR A COMPLETE JOB. ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED AND SUPPORTED IN A FIRST-CLASS AND WORKMANLIKE MANNER BY MECHANICS SKILLED IN THEIR PARTICULAR TRADES. A LICENSED PLUMBING CONTRACTOR SHALL PERFORM WORK. SANITARY SEWER SYSTEMS: PROVIDE CLEANOUTS WHERE REQUIRED, WHETHER SHOWN ON DRAWINGS OR NOT. PIPE IN GRADE BELOW FLOOR SLABS SHALL BE RIGID PVC SCHEDULE 40, TYPE 1, GRADE 1, COMPLYING WITH ASTM D2665 AND D-1784. PRESSURE TEST AND REPLACE DEFECTIVE MATERIALS AND CONNECTIONS. WASTE AND VENTS: SOIL, WASTE AND VENT LINES SHALL BE PVC SCHEDULE 40 ASTM D1785 WITH ASTM D2665 DWV SOCKET FITTINGS; OR, SERVICE WEIGHT CAST IRON, OR AS REQUIRED BY LOCAL CODES. SLOPE WASTE PIPING UNIFORMLY 1/8" PER FOOT MINIMUM. SLOPE VENT PIPING TO PREVENT CONDENSATION FROM SYSTEM. TEST SOIL, WASTE, AND VENT PIPING SHALL BE TESTED TO A MINIMUM 10 FEET OF HEAD MAINTAINED FOR A MINIMUM 15 MINUTES. REPLACE DEFECTIVE PIPE AND JOINTS AT NO ADDITIONAL COST TO OWNER. FLOOR DRAINS SHALL BE EQUAL TO SMITH 2010-A. FLOOR CLEANOUTS SHALL BE EQUAL TO SMITH 4021 OR 4021Y. WALL CLEANOUTS SHALL BE EQUAL TO SMITH 4710. PROVIDE AND INSTALL ALL REQUIRED OR SHOWN BACK-FLOW PREVENTERS. DOMESTIC WATER SYSTEM: WATER SUPPLY LINES SHALL BE OF TYPE "L" OR "K" COPPER AS REQUIRED BY LOCAL PLUMBING CODES. ALL WATER SUPPLY LINES SHALL BE RUN UNDER FLOOR SLAB AND UP PLUMBING WALLS. SIZE WATER SUPPLY AS REQUIRED FOR BUILDING USAGE. BACKFLOW PREVENTERS SHALL BE INSTALLED IF REQUIRED BY STATE AND LOCAL ORDINANCES. INSTALL WARM WATER LINES ON WARM SIDE OF CEILING INSULATION. BACKFLOW PREVENTERS SHALL BE INSTALLED IF REQUIRED BY STATE AND LOCAL ORDINANCES. INSTALL WARM WATER LINES ON WARM SIDE OF CEILING INSULATION. PRESSURE TEST TO 50 PSIG ABOVE OPERATING PRESSURE (125 PSIG MIN.) AND MAINTAIN PRESSURE FOR 15 MINUTES MINIMUM WITH NO PRESSURE LOSS. REPLACE DEFECTIVE MATERIALS AND CONNECTIONS. CLEAN, FLUSH AND DISINFECT ALL WATER PIPING IN ACCORDANCE WITH AWWA C601. INSTALL PID RATED SHOCK ABSORBERS IN COLD WATER LINES WHERE REQUIRED. ALL WATER SUPPLY (BOTH HOT AND COLD) LINES ABOVE FLOOR SLAB SHALL BE INSULATED WITH 3/4" ARMA FLEX TYPE INSULATION. INSTALL DIELECTRIC UNIONS WHERE DISSIMILAR METALS ARE CONNECTED. PLUMBING FIXTURES: FIXTURES SHALL BE COMPLETE WHEN FULLY INSTALLED, INCLUDING TRIM, VALVES, SUPPLIES AND ESCUTCHEONS. TRIM SHALL BE BRASS CHROME PLATED; FIXTURES SHALL BE WHITE, UNLESS OTHERWISE NOTED. SEAL CRACKS AROUND EACH FIXTURE AT WALL AND FLOOR WITH PERMANENTLY PLIABLE WHITE SILICONE SEALANT. STRICTLY FOLLOW ACCESSIBILITY STANDARDS NOTED BELOW. DOMESTIC WATER HEATING: PROVIDE GAS FIRED STORAGE WATER HEATER COMPLETE WITH POWER BURNER OR ELECTRIC WATER HEATER TO SIZE REQUIRED. TANK SHALL BE CONSTRUCTED IN ACCORDANCE WITH ASME CODE, STAMPED AND TESTED. TANK SHALL BE INSULATED. THE COMPLETE WATER HEATER SHALL BE LISTED BY UL, WITH LABEL ATTACHED. VENTING FOR GAS WATER HEATERS: UL APPROVED TYPE B DOUBLE-WALL GAS VENT PIPING. VENT EXTENDED 3 FEET ABOVE THE ROOF, MINIMUM TWO FEET HIGHER THAN ANY PORTION OF BUILDING WITHIN 10 FEET. ACCESSIBILITY STANDARDS: STRICTLY COMPLY WITH THE REQUIREMENTS OF UNIFORM FEDERAL ACCESSIBILITY STANDARDS (UFAS), THE ADA, AND IBC, INDIANA CODE CHAPTER 11. PROVIDE RAISED SEAT FOR THE ACCESSIBLE WATER CLOSETS, PROVIDE FLUSH ON ACCESS SIDE OF WC'S, TRAP TIGHT TO THE WALL UNDER LAVATORIES, INSULATE ALL WASTE AND WATER PIPING BELOW LAVATORIES, AS WELL AS ALL OTHER ADA REQUIREMENTS. THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY IF REQUIRED DIMENSIONS, CLEARANCES, OR STRUCTURAL CONDITIONS EXIST THAT COULD PREVENT THE ABOVE ACCESSIBILITY REQUIREMENTS FROM BEING STRICTLY FOLLOWED. TESTING: ALL PIPES SHALL BE PRESSURE TESTED PER STANDARD PRACTICE. REPLACE ALL DEFECTIVE LINES AND CONNECTIONS AT NO ADDITIONAL COST TO OWNER. MANUALS: TWO COPIES OF OPERATION AND MAINTENANCE MANUALS FOR MATERIALS INSTALLED PER WORK OF THIS SECTION SHALL BE DELIVERED TO OWNER PRIOR TO ACCEPTANCE OF THESE SPACES FOR OCCUPANCY. BACKFLOW PREVENTION DEVICES FOR BEVERAGE STATIONS: THE CONTRACT DOCUMENTS CONSIST OF THE DRAWINGS AND SPECIFICATIONS ON THE DRAWINGS. THE INTENT OF THE CONTRACT DOCUMENTS IS TO INCLUDE ITEMS NECESSARY FOR THE PROPER EXECUTION OF THE WORK. NEW CONSTRUCTION SHALL CONFORM TO ALL APPLICABLE CITY, STATE AND LOCAL BUILDING CODES AND NFPA CODES FOR THIS CLASS OF WORK. REQUIREMENTS: ALL WORK RELATED TO THE BEVERAGE DISPENSERS AND BEVERAGE AREAS SHALL BE PROTECTED BY THE PROVISIONS OF THE INDIANA PLUMBING CODE 2012 EDITION SECTIONS 608.16.1 AND 608.16.10. CONNECTIONS TO POTABLE WATER SYSTEM: SPECIFICALLY BEVERAGE DISPENSERS SHALL BE PROTECTED AGAINST BACKFLOW BY A BACKFLOW PREVENTER CONFORMING TO ASSE 1022. THE PORTION OF THE BACKFLOW PREVENTER DEVICE DOWNSTREAM FROM THE SECOND CHECK VALVE AND THE PIPING DOWNSTREAM THEREFROM SHALL NOT BE AFFECTED BY CARBON DIOXIDE GAS. COFFEE MACHINES AND NONCARBONATED BEVERAGE DISPENSERS: THE WATER SUPPLY CONNECTION TO COFFEE MACHINES AND NONCARBONATED BEVERAGE DISPENSERS SHALL BE PROTECTED AGAINST BACKFLOW BY A BACKFLOW PREVENTER CONFORMING TO ASSE 1022. INSTALLATION: BACKFLOW PREVENTERS SHALL BE INSTALLED STRICTLY ACCORDING TO MANUFACTURER’S WRITTEN INSTRUCTIONS AND ACCORDING TO THE CODES REFERENCED ABOVE. CONDENSATE LINE CONDENSATE LINE P1.1