Loading...
HomeMy WebLinkAboutVWC CONV STORE24 M1.1 10-14-2021I I IREVISIONS:DRAWING COMPLETION DATE:4820 Buttonwood CrescentARCHITECT AIAGORDON CLARKIndianapolis, Indiana 46228Phone: 317 255-2546317 252-5573Fax: GClark4820@aol.comCONVENIENCE STORE / FOOD MARTVILLAGE OF WEST CLAYCARMEL, INDIANASOUTHWEST CORNER OFHARLESTON STREET AND TOWNE ROADOCTOBER 14, 2021 FOR PERMITTING AND CONSTRUCTION300 CFM 300 CFM 300 CFM 300 CFM 200 CFM 225 CFM 225 CFM 225 CFM 225 CFM 225 CFM 225 CFM 225 CFM 225 CFM 200 CFM 250 CFM 250 CFM 200 CFM 200 CFM 200 CFM 200 CFM 250 CFM 125 CFM 125 CFM 75 CFM EXHAUST 75 CFM EXHAUST EXHAUST TO DAYLIGHT INSTALL RAIN AND INSECT SCREEN 6" FLEX 6" FLEX DAMPER ALL BRANCHES 10" FLEX 10" FLEX 10" FLEX 10" FLEX 8" FLEX 8" FLEX 8" FLEX 8" FLEX DAMPER ALL BRANCHES DAMPER ALL BRANCHES 8" FLEX 8" FLEX 8" FLEX 8" FLEX DAMPER ALL BRANCHES 10" ROUND 10" ROUND 8" FLEX 8" FLEX DAMPERS 25" x 8" 8" FLEX 8" FLEX 32" x 8" GRILLES WITH DAMPERS COOLER PACKAGE BY MFGR. CONDENSER LINE TO DRAIN 200 CFM MECHANICAL SCHEDULE SCALE: 1/4" = 1'-0" MECHANICAL PLAN ROOFTOP COOLING-HEATING UNITS THE ROOFTOP UNITS SHALL BE FACTORY PACKAGED WITH CIRCULATING FAN, GAS-FIRED HEATING SECTION AND AIR-COOLED REFRIGERATION SECTION. UNIT SHALL BE ROOF CURB MOUNTED. UNIT SHALL BE RATED IN ACCORDANCE WITH ARI STANDARDS 270 AND 360 AND TESTED AND CERTIFIED BY UL OR ETL TO CONFORM TO APPLICABLE ANSI STANDARDS. A WALL MOUNTED SPACE THERMOSTAT SHALL BE FURNISHED WITH THE UNIT. THE REFRIGERATION SYSTEM AND FURNACE HEAT EXCHANGERS SHALL CARRY A FIVE-YEAR WARRANTY. PROVIDE CONDENSATE DRAINAGE PIPING FROM THE DRAIN PAN WITH A 4” DEEP TRAP AND CLEANOUT. THE ELECTRICAL CONTRACTOR WILL PROVIDE POWER WIRING THRU A FUSED DISCONNECT SWITCH ON ONE SET OF POWER TERMINALS IN EACH UNIT. ALL OTHER POWER AND CONTROL WIRING REQUIRED FOR THE COMPLETION OF THE SYSTEM SHALL BE FURNISHED AND INSTALLED BY THE HVAC CONTRACTOR. ALL WIRING BY ANY CONTRACTOR SHALL MEET OR EXCEED ALL STATE AND LOCAL CODES AND ORDINANCES. INSTALL A LOCAL DISCONNECT WITHIN THE LINE OF SIGHT OF TO ALL PERMANENTLY CONNECTED ROOFTOP EQUIPMENT. THIS CAN ALSO INCLUDE CONDENSERS FOR COOLER UNITS AND HOOD INTAKE AND EXHAUST FANS. PROVIDE A RECEPTACLE WITHIN 25 FEET OF THE ROOFTOP UNITS. IT SHALL BE GFIC PROTECTED. THE GFIC TESTING THE TRIPPING RESET SHOULB BE READILY ACCESSIBLE FOR SERVICING OF ROOFTOP EQUIPMENT. PROVIDE “WHILE-IN-USE” WEATHERPROOF COVERS FOR RECEPTACLES INSTALLED IN A WET LOCATION SO THAT THE RECEPTACLE REMAINS WATERTIGHT WHILE A CORD IS PLUGGED IN. MECHANICAL SPECIFICATIONS AND GENERAL REQUIREMENTS: THE CONTRACT DOCUMENTS CONSIST OF THE DRAWINGS AND SPECIFICATIONS ON THE DRAWINGS. THE INTENT OF THE CONTRACT DOCUMENTS IS TO INCLUDE ITEMS NECESSARY FOR THE PROPER EXECUTION OF THE WORK. NEW CONSTRUCTION SHALL CONFORM TO ALL APPLICABLE CITY, STATE AND LOCAL BUILDING CODES AND NFPA CODES FOR THIS CLASS OF WORK. MECHANICAL CONTRACTOR IS RESPONSIBLE FOR ALL APPLICABLE PERMITS, INSPECTIONS AND LICENSES NECESSARY TO COMPLETE THIS INSTALLATION AND THE SATISFACTORY OPERATION OF THE SYSTEM. MECHANICAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND DIMENSIONS AT THE JOBSITE. IF DISCREPANCIES ARE FOUND THE GENERAL CONTRACTOR SHALL BE NOTIFIED BEFORE PROCEEDING WITH ANY WORK OR ORDERING ANY EQUIPMENT OR MATERIAL IN THE AFFECTED AREA. FIT AND QUANTITY OF THE MECHANICAL SYSTEMS TO BE INSTALLED, WITH THE VARIOUS NECESSARY PARTS AND MATERIALS TO MAKE A COMPLETE AND FINISHED JOB, SHALL BE VERIFIED AND COORDINATED PRIOR TO START OF CONSTRUCTION AND ARE THE EXCLUSIVE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR. THE MECHANICAL CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER TRADES AND VERIFY ALL POWER AND DRAINS ARE PROVIDED AND IN THE PROPER LOCATION. ALL EQUIPMENT AND MATERIALS SHALL BE INSTALLED PER THE MANUFACTURER'S SUGGESTED INSTALLATION REQUIREMENTS IN A NEAT AND WORKMANLIKE MANNER. MECHANICAL DRAWINGS ARE DIAGRAMMATIC AND MUST BE FIELD VERIFIED FOR EXACT ROUTING AND ADDITIONAL EQUIPMENT OR DEVICES NECESSARY FOR COMPLETE JOB. MECHANICAL CONTRACTOR SHALL PROVIDE ALL CONTACTORS, RELAYS AND THERMOSTATS. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL SWITCHES AND DISCONNECTS. THE MECHANICAL CONTRACTOR SHALL COMPLETE TEMPERATURE CONTROL WIRING. PROVIDE ALL NECESSARY HANGERS, FASTENERS, CLIPS AND OTHER DEVICES REQUIRED FOR A COMPLETE JOB. SUPPORT: SUSPENDED TYPE UNIT HEATERS SHALL BE SUPPORTED BY ELEMENTS THAT ARE DESIGNED AND CONSTRUCTED TO ACCOMMODATE THE WEIGHT AND DYNAMIC LOADS. HANGERS AND BRACKETS SHALL BE OF NONCOMBUSTIBLE MATERIAL. USE UNISTRUT-TYPE SUPPORT MATERIALS RATED FOR WEIGHT OF THE UNITS. CONNECT TO STRUCTURAL ELEMENTS. NO CONNECTIONS TO ROOFING MATERIALS SHALL BE ALLOWED. GAS PIPING SPECIFICATIONS: BLACK STEEL: 2" OR SMALLER-SCHEDULE 40, GRADE "B" ASTM A120 SCREWED 150 PSI BLACK MALLEABLE IRON FITTINGS. VALVES: PLUG TYPE GAS SUPPORTS SHALL BE MINIMUM OF 10'-0" O.C. ALL HVAC UNITS SHALL BE INSTALLED COMPLETE WITH ECONOMIZERS, LOW AMBIENT KITS, AND REQUIRED CURBS, ETC. MANUFACTURER'S MINIMUM CLEARANCE RECOMMENDATIONS SHALL BE MAINTAINED ON ALL EQUIPMENT AND DUCTWORK. ALL EXHAUST DUCTWORK SHALL BE METAL ROUND DUCTWORK. NO FLEXIBLE ROUND DUCTWORK SHALL BE USED. ALL MAIN DUCTS SHALL BE GALVANIZED STEEL WRAPPED WITH FOIL-BACK INSULATION OR DUCT BOARD. INSTALL PER SMACNA STANDARDS. TURNING VANES SHALL BE INSTALLED AT ELBOWS LARGER THAN 12" X 12". ALL METAL DUCTWORK SHALL BE FABRICATED FROM GALVANIZED SHEET STEEL OF GAUGES, REINFORCEMENT COMPLYING WITH SMACNA "HVAC DUCTWORK CONSTRUCTION STANDARDS." THE ARCHITECT SHALL HAVE ACCESS TO THE CONSTRUCTION SITE AND HAVE THE RIGHT TO REJECT ANY WORK (AFTER CONSULTATION WITH THE GENERAL CONTRACTOR) THAT DOES NOT CONFORM TO THE DRAWINGS, SPECIFICATIONS, CODES OR WORK THAT HAS NOT BEEN EXECUTED IN A WORKMANLIKE MANNER. CONTRACTOR SHALL BE RESPONSIBLE FOR NOTICE TO THE INSPECTING AUTHORITIES, ARCHITECT, OR GENERAL CONTRACTOR, SO THAT WORK CAN BE INSPECTED OR APPROVED BEFORE COVERING. THIS PROCEDURE SHALL OCCUR WITHOUT AFFECTING CONSTRUCTION PROGRESS AND COMPLETION. THE INTENTION OF THESE DOCUMENTS IS TO PROVIDE THE OWNER WITH A BUILDING COMPLETE IN ITS ENTIRETY AT THE TIME OF OCCUPANCY. IT IS THE SUB-CONTRACTOR'S RESPONSIBILITY TO CONTRACT THE GENERAL CONTRACTOR DURING THE BIDDING/PRICING PHASE OF ANY DETAILS MISSING, VAGUE, ORE INCOMPLETE SO THAT AN APPROPRIATE ADDENDUM OR CLARIFICATION CAN BE ISSUED. THE SELECTED CONTRACTOR SHALL PROVIDE ALL MATERIALS, LABOR, TOOLS, EQUIPMENT, AND SERVICES NECESSARY FOR A COMPLETE, FUNCTIONAL, AND OPERATIONAL FACILITY. TWO COPIES OF OPERATION AND MAINTENANCE MANUALS FOR MATERIALS INSTALLED PER WORK OF THIS SECTION SHALL BE DELIVERED TO OWNER PRIOR TO ACCEPTANCE OF THESE SPACES FOR OCCUPANCY. RTU #1 RTU #2 4 TON 6 TON BEVERAGE COOLER COOLING BY MANUFACTURER PROVIDE CONDENSATE LINE TO APPROPRIATE DRAIN LOCATION FREEZER. COOLED BY MANUFACTURER M1.1