Loading...
HomeMy WebLinkAboutVWC CONV STORE26 E1.2 10-14-2021SCALE: 1/4" = 1'-0" I I IREVISIONS:DRAWING COMPLETION DATE:4820 Buttonwood CrescentARCHITECT AIAGORDON CLARKIndianapolis, Indiana 46228Phone: 317 255-2546317 252-5573Fax: GClark4820@aol.comCONVENIENCE STORE / FOOD MARTVILLAGE OF WEST CLAYCARMEL, INDIANASOUTHWEST CORNER OFHARLESTON STREET AND TOWNE ROADOCTOBER 14, 2021 FOR PERMITTING AND CONSTRUCTION220V GFI GFI GFI GFI HIGH FOR SIGN AND/OR SHOW WINDOWS POS POS DED DED DED GFI GFI GFI GFI DRAWING NOTES: 1. 2. 3. 4. 5. MINIMUM WIRE SIZE TO BE #12 AWG COPPER INSTALLATION TO MEET ALL STATE AND LOCAL CODES. ALL WIREING TO BE INSTALLED IN METAL RACEWAYS OR MC CABLE WHERE PERMITTED BY CODE. MAXIMUM LOAD OF 1,600 WATTS FOR 20 AMP BRANCH CIRCUITS. FINAL LOCATIONS OF ALL DEVICES AND EQUIPMENT CONNECTIONS TO BE VERIFIED BY THE OWNER. ELECTRICAL RISER DIAGRAM 2-1 2" PVC CONDUIT WITH (4) 4 0 AL AND (1) #2 GROUND WIRE NOT TO SCALE SUPPLY FAN: USE CIRCUIT 20 115 V 1/2 HP 4.80 AMPS EXHAUST FAN: USE CIRCUIT 22 115 V 3/4 HP 13.80 AMPS CONDENSER USE CIRCUIT 24 20 AMP 2 POLE EVAPORATOR USE CIRCUIT 26 15 AMP 2 POLE FOR HOOD SYSTEM (FUTURE) GROUND ROD TO #6 THHN #4 THHN TO THE BUILDING STEEL DISCONNECT 200 AMP 3 PHASE 42 SPACE PANEL GROUND ROD TO #6 THHN #4 THHN TO THE BUILDING STEEL DISCONNECT 200 AMP 3 PHASE 42 SPACE PANEL METER BASE AS REQUIRED #4 THHN TO THE BUILDING STEEL SUB-PANEL GROUND ROD TO #6 THHN FOR FUEL SYSTEMS100 AMP SINGLE PHASE USE DUAL RATED THHN WIRE 4 WIRE PER CABLE FOR COOLERS AND FREEZER DISCONNECT 20A/2P CIRCUIT FOR CONDENSER IN COOLER AND FREEZER 15A/2P CIRCUIT FOR LIGHTS 200 AMP 200 AMP 100 AMP 400 AMP CT CABINET TWO 200 AMP DISCONNECTS METER BASE FEED FROM PUBLIC SERVICE LOCATE PER LOCAL UTILITY REQUIREMENTS UNDERGROUND SERVICE DRIVEWAY RATED SODA ON ONE CIRCUIT 2 RECEPT. GFI GFI GFI GFI GFI GFI GFI GFIGFI 15A/2P CIRCUIT FOR EVAPORATOR ENTIRE BEVERAGE AREA 11 RECEPTACLES ON 8 CIRCUITS COUNTS SODA INDICATED ALL GFI PROTECTED FOOD SERVICE AREA 5 RECEPTICLES ON 2 CIRCUITS GFI GFI GFI GFI GFI GFI ELECTRICAL POWER PLAN POS FREEZER SIMILAR TO COOLER REQUIREMENTS 110V DUPLEX RECEPTICAL GFI 110 V RECEPTICAL GF PROTECTED DED 110 V RECEPTICAL, DEDICATED 220 B RECEPTICAL220V PHONE / DATA OUTLET SYMBOLS ELECTRICAL SPECIFICATIONS AND GENERAL REQUIREMENTS: THE CONTRACT DOCUMENTS CONSIST OF THE DRAWINGS AND SPECIFICATIONS ON THE DRAWINGS. THE INTENT OF THE CONTRACT DOCUMENTS IS TO INCLUDE ITEMS NECESSARY FOR THE PROPER EXECUTION OF THE WORK. BUILDING CODES: NEW CONSTRUCTION SHALL CONFORM TO ALL APPLICABLE CITY, STATE AND LOCAL BUILDING CODES FOR THIS CLASS OF WORK. ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND DIMENSIONS AT THE JOBSITE. IF DISCREPANCIES ARE FOUND THE GENERAL CONTRACTOR SHALL BE NOTIFIES BEFORE PROCEEDING WITH ANY WORK OR ORDERING ANY EQUIPMENT OR MATERIAL IN THE AFFECTED AREA. FIT AND QUANTITY OF THE WIRING, ELECTRICAL EQUIPMENT, THE VARIOUS NECESSARY PARTS AND MATERIALS TO MAKE A COMPLETE AND FINISHED JOB SHALL BE VERIFIED AND COORDINATED PRIOR TO START OF CONSTRUCTION AND ARE THE EXCLUSIVE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. LOCAL UTILITY COORDINATION: ELECTRICAL CONTRACTOR SHALL COORDINATE TRANSFORMERS AND SERVICE REQUIREMENTS WITH THE LOCAL UTILITY COMPANY. THE E.C. SHALL CONSULT WITH THE LOCAL UTILITY TO ESTABLISH REQUIRED kACI RATINGS. ALL FIXTURES, EQUIPMENT AND MATERIALS SHALL BE INSTALLED PER THE MANUFACTURER'S SUGGESTED INSTALLATION REQUIREMENTS IN A NEAT AND WORKMANLIKE MANNER. UL LABELING: ALL ELECTRICAL EQUIPMENT SHALL HAVE "UL" LABELS. WIRING DEVICES SHALL BE SPECIFICATION GRADE. PROVIDE ALL DISCONNECTS REQUIRED PER NATIONAL AND LOCAL ELECTRICAL CODES RATED TO UTILITY SUPPLIED kAIC LIMITS, OR, IF NOT SUPPLIED, TO NEC MINIMUMS. ALL EXPOSED WIRE AND WIRING BELOW CONCRETE SLABS SHALL BE IN CONDUIT. WIRE: ALL WIRE SHALL BE COPPER, MINIMUM SIZE #12 AWG. ALL CONDUCTORS SHALL HAVE TYPE "THHN" INSULATION. CONDUCTORS #10 AND SMALLER MAY BE SOLID. GROUNDING CABLES SHALL BE NO SMALLER THAN 4 COPPER. BREAKER PANELS: FURNISH AND INSTALL A BREAKER PANEL AS MANUFACTURED BY SQUARE D OR ITE. INSTALL PANEL SO TOP BREAKER IS NO HIGHER THAN 6'-0". FURNISH AND INSTALL TYPEWRITTEN DIRECTORY. IDENTIFY AND LABEL ALL ELECTRICAL SERVICE EQUIPMENT. GROUNDING: GROUNDING SHALL BE DONE STRICTLY ACCORDING TO SECTION 250.52 OF THE NATIONAL ELECTRIC CODE USING ACCEPTABLE ELECTRODES AND CONNECTIONS. SWITCHES: ALL SWITCHES SHALL BE RATED 20 AMP, 125 VOLT AND SHALL BE MOUNTED 4'-6" AFF, UNLESS NOTED OTHERWISE. RECEPTICALS: ALL RECEPTACLES TO BE 15 AMP, 125 VOLT, GROUNDING TYPE AND SHALL BE MOUNTED 18" AFF, UNLESS NOTED OTHERWISE. PROVIDE TEMPORARY POWER REQUIRED BY THE GENERAL CONTRACTOR AND OTHER TRADES. COORDINATE POWER REQUIREMENTS WITH GC PRIOR TO INSTALLATION. LIGHTING FIXTURES: LIGHTING FIXTURES TO BE FURNISHED AND INSTALLED COMPLETE WITH LAMPS AS DETAILED ON THE PLANS OR AS INTENDED. SEE REFLECTED CEILING PLAN AND/OR LIGHTING PLAN FOR THE EXACT LOCATION OF THE CEILING GRID, LIGHT FIXTURES, OR THE GENERAL INTENT OF THE DRAWINGS. SEE THE ELECTRICAL DRAWING(S) FOR THE FIXTURE SCHEDULE, NOTES AND OTHER SPECIFICATION REQUIREMENTS. CONTRACTOR SHALL BE RESPONSIBLE FOR NOTICE TO THE INSPECTING AUTHORITIES, ARCHITECT, OR GENERAL CONTRACTOR, SO THAT WORK CAN BE INSPECTED OR APPROVED BEFORE COVERING. THIS PROCEDURE SHALL OCCUR WITHOUT AFFECTING CONSTRUCTION PROGRESS AND COMPLETION. THE INTENTION OF THESE DOCUMENTS IS TO PROVIDE THE OWNER WITH A BUILDING COMPLETE IN ITS ENTIRETY AT THE TIME OF OCCUPANCY. IT IS THE SUB-CONTRACTOR'S RESPONSIBILITY TO CONTACT THE GENERAL CONTRACTOR DURING THE BIDDING/PRICING PHASE OF ANY DETAILS MISSING, VAGUE, OR INCOMPLETE SO THAT AN APPROPRIATE ADDENDUM OR CLARIFICATION CAN BE ISSUED. THE SELECTED CONTRACTOR SHALL PROVIDE ALL MATERIALS, LABOR, TOOLS, EQUIPMENT, AND SERVICES NECESSARY FOR A COMPLETE, FUNCTIONAL, AND OPERATIONAL FACILITY. E1.2