HomeMy WebLinkAboutVOWC ARCHITECTURAL SET COMBINED DRAWINGSI I I A R C H I T E C T : DRAWING COMPLETION DATE: 4820 Buttonwood Crescent ARCHITECT AIAGORDON CLARK Indianapolis, Indiana 46228 Phone: 317 255-2546 317 252-5573Fax: GClark4820@aol.com FOR PERMITTING AND CONSTRUCTION GENERAL REQUIREMENTS AND GUIDELINES FOR THIS PROJECT: THE CONTRACT DOCUMENTS CONSIST OF THE DRAWINGS AND SPECIFICATIONS ON THE DRAWINGS. THE INTENT OF THE CONTRACT DOCUMENTS IS TO INCLUDE ITEMS NECESSARY FOR THE PROPER EXECUTION OF THE WORK. THE CONTROLLING CODE FOR ALL WORK UNDER THESE DRAWINGS SHALL BE THE INTERNATIONAL BUILDING CODE 2014 WITH INDIANA AMENDMENTS, ALL IN THEIR CURRENT ADDITIONS. THE CONTROLLING DOCUMENT FOR ALL WORK UNDER THESE DRAWINGS SHALL BE THE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION, AIA (AMERICAN INSTITUTE OF ARCHITECTS) DOCUMENT A201, CURRENT EDITION. AGREEMENT BY ANY PARTY TO WORK UNDER THIS CONTROLLING DOCUMENT SHALL COMMENCE WITH THE START OF ANY WORK DESCRIBED WITHIN THESE DOCUMENTS. THE ARCHITECT SHALL FILE FOR STATE PLAN REVIEW AND PROVIDE A RELEASE FOR USE IN OBTAINING LOCAL PERMITS. THE GENERAL CONTRACTOR SHALL FILE DRAWINGS OR OTHER MATERIALS FOR PERMIT APPLICATION AT THE LOCAL LEVEL AND SECURE ALL NECESSARY BUILDING PERMITS. SUB- CONTRACTORS TO THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING THEIR OWN LOCAL PERMITS. PRIOR TO COMMENCING ACTIVITIES, EACH CONTRACTOR AND MATERIAL SUPPLIER SHALL CAREFULLY STUDY AND COMPARE THE CONTRACT DOCUMENTS AND BECOME FULLY AWARE OF THE REQUIREMENTS. EACH CONTRACTOR AND MATERIAL SUPPLIER SHALL TAKE FIELD MEASUREMENTS AND VERIFY FIELD CONDITIONS AND SHALL CAREFULLY COMPARE SUCH MEASUREMENTS AND CONDITIONS WITH THE CONTRACT DOCUMENTS. IN THE EVENT OF INCONSISTENCIES WITHIN OR BETWEEN THE CONTRACT DOCUMENTS, EACH CONTRACTOR OR MATERIAL SUPPLIER SHALL PROVIDE THE BETTER QUALITY OR GREATER QUANTITY OF THE WORK, AND SHALL COMPLY WITH THE STRICTER REQUIREMENT. INCONSISTENCIES DISCOVERED SHALL BE IMMEDIATELY REPORTED TO THE ARCHITECT IN WRITING. NO PLEAS OF IGNORANCE RESULTING FROM FAILURE TO EXAMINE THE REQUIREMENTS OF THE CONTRACT DOCUMENTS OR THE CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED WILL BE ACCEPTED AS AN EXCUSE FOR FAILURE OR OMISSION ON THE PART OF EACH CONTRACTOR AND MATERIAL SUPPLIER TO FULFILL IN EVERY RESPECT ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS. VERIFY THAT SURFACES TO RECEIVE MATERIALS ARE IN A CONDITION TO ACCOMMODATE INSTALLATION. IMMEDIATELY REPORT TO THE ARCHITECT ANY ARCHITECT / ENGINEER NOTIFICATION: IF THE GENERAL CONTRACTOR DISCOVERS CONDITIONS THAT ARE NOT SUBSTANTIALLY LIKE THE ARCHITECT’S DRAWINGS, THE ARCHITECT OR ENGINEER SHALL BE IMMEDIATELY NOTIFIED. THIS NOTIFICATION RELATES TO ALL PARTS OF THIS PROJECT, INCLUDING BUT NOT LIMITED TO DISCOVERED SOIL CONDITIONS, INAPPROPRIATE OR NON- SPECIFIED PRODUCTS DELIVERED AND/OR INSTALLED ON SITE, OR ANY QUESTION REGARDING POSSIBLE VIOLATION OF CODES OR ORDINANCE STANDARDS. PROCEEDING WITH THE WORK SHALL CONSTITUTE ACCEPTANCE BY THE GENERAL CONTRACTOR OF THE EXISTING CONDITIONS, AND THAT THE PROJECT CAN BE BUILT STRUCTURALLY SOUND AND MEETING LOCAL CODES. Indiana Adopted Codes for Building Construction In effect December 1, 2014 2014 Indiana Building Code Adoption by Reference: 2012 International Building Code First Printing plus Indiana Amendments, effective December 1st 2014. 2009 Indiana Electrical Code Adoption by Reference: 2008 National Electric Code First Printing plus Indiana Amendments, effective August 26, 2009. 2014 Indiana Fuel Gas Code Adoption by Reference: 2012 International Fuel Code First Printing plus Indiana Amendments, effective December 1st 2014. 2014 Indiana Mechanical Code Adoption by Reference: 2012 International Mechanical Code First Printing plus Indiana Amendments, effective December 1st 2014. 2012 Indiana Plumbing Code Adoption by Reference: 2006 International Plumbing Code Second Printing plus the Indiana Amendments, effective December 24, 2012. 2005 Indiana Residential Code Adoption by Reference: 2003 International Residential Code Fifth Printing plus Indiana Amendments, effective September 11, 2005. 2014 Indiana Fire Code Adoption by Reference: 2012 International Fire Code First Printing plus Indiana Amendments, effective December 1st 2014. 2010 Indiana Energy Conservation Code Adoption by Reference: 2007 Edition ASHRAE 90.1 plus Indiana Amendments, effective May 6, 2010. A Complete list of all codes and other rules adopted by the Fire Prevention & Building Safety Commission of the State of Indiana along with PDF versions of the Indiana Amendments can be found at: http://www.in.gov/dhs/2490.htm DISCREPANCIES OR ERRORS WHICH WOULD RESULT IN POOR APPLICATION OR CAUSE LATENT DEFECTS IN WORKMANSHIP. IF A CONTRACTOR OR SUB- CONTRACTOR PROCEEDS WITH INSTALLATION OF MATERIALS OVER ANOTHER CONTRACTOR'S WORK, IT SHALL BE ASSUMED THAT THE CONTRACTOR OR SUB- CONTRACTOR ACCEPTS THE WORK TO RECEIVE HIS MATERIAL. ALL LABOR, CONSTRUCTION MATERIALS, PROVIDED AND INSTALLED TO COMPLETE THE WORK OF THESE CONTRACT DOCUMENTS SHALL BE EXECUTED IN COMPLETE COMPLIANCE WITH ALL LOCAL, STATE AND FEDERAL CODES, PRACTICES OR ORDINANCES AND WITHIN THE CONSTRAINTS OF THE HIGHEST ACCEPTABLE CONSTRUCTION PRACTICES. UPON COMPLETION OF THE PROJECT, OBTAIN ALL FINAL INSPECTIONS AS REQUIRED BY THE LOCAL JURISDICTIONS AND FURNISH OWNER WITH EVIDENCE OF ALL SUCH INSPECTIONS AND CERTIFICATES OF OCCUPANCY, IF ISSUED BY THE JURISDICTION. THE GENERAL CONTRACTOR SHALL PROVIDE REASONABLE SUPERVISION AND COORDINATION OF ALL SUB-CONTRACTORS WORK INCLUDING WORK PERFORMED BY OTHERS SUCH AS SUPPLIERS OF OWNER-SUPPLIED ITEMS. UPON COMPLETION OF PROJECT, PROVIDE OWNER WITH ALL INSTRUCTION MANUALS, WARRANTIES OR OTHER DOCUMENTS REQUIRED FOR THE PROPER OPERATION OR MAINTENANCE OF ANY PART OF THE CONTRACTOR'S WORK. THE GENERAL CONTRACTOR SHALL PROVIDE ALL NECESSARY PROTECTION AND SECURITY MEANS FOR HIS WORK UNTIL TURNED OVER TO THE OWNER. IF THE PROJECT AREA IS TO BE USED BY EMPLOYEES OR THE PUBLIC DURING CONSTRUCTION, FULLY PROTECT THE CONSTRUCTION SITE, CONSTRUCT BARRIERS AND FENCING, AND PROVIDE APPROPRIATE SIGNAGE TO PROTECT THESE PERSONS. THE GENERAL CONTRACTOR SHALL PROVIDE AND MAINTAIN MINIMUM GENERAL LIABILITY INSURANCE. THE FRANCHISEE, FRANCHISER, AND THE ARCHITECTS SHALL BE HELD HARMLESS AGAINST ALL GENERAL LIABILITY CLAIMS THAT MAY RESULT AS A PART OF THIS PROJECT. SOILS: OTHERS HAVE CHOSEN TO NOT TEST SOILS FOR THIS PROJECT, NOR MAKE SOIL DATA AVAILABLE TO THE ARCHITECT. THE ARCHITECT SHALL BE HELD HARMLESS FOR ANY COMMON SOIL FAILURES SUCH AS FAILURE OF COMPACTION; DENSITY FAILURE; GENERAL SOIL SHEAR OR SHRINKAGE; SETTLEMENT FAILURE; SLOPE FAILURE; FLOW SLIDE FAILURE; MOVEMENTS CAUSED BY EXPANISIVE OR HIGHLY PLASTIC SOILS; OR ANY OTHER COMMONY ANALYIZED SOIL FAILURES. CONVENIENCE STORE / FOOD MART VILLAGE OF WEST CLAY CARMEL, INDIANA SOUTHWEST CORNER OF HARLESTON STREET AND TOWNE ROAD OCTOBER 14, 2021 INDEX OF DRAWINGS OF THIS SET: ARCHITECTURAL, STRUCTURAL, PLUMBING, MECHANICAL, ELECTRICAL DRAWINGS: COVER SHEET GENERAL PROJECT GUIDELINES; INDIANA BUILDING CODES A1.1 FLOOR PLAN A1.2 FOUNDATION PLAN; CONCRETE SPECIFICATIONS A1.3 REFLECTED CEILING PLAN; ACOUSTIC CEILING SPECIFICATIONS; BULKHEAD GUIDELINES A1.4 ROOF FRAMING PLAN; JOIST BRACING CUT SHEET A1.5 ROOF PLAN; ROOF MEMBRANE SPECS.; SCUPPER CUT SHEETS LS1.1 LIFE SAFETY PLAN; BUILDING CODE SUMMARY A2.1 BUILDING ELEVATIONS A2.2 BUILDING ELEVATIONS A3.1 TRANSVERSE SECTION THRU TYPICAL MASONRY WALLS A3.2 TRANSVERSE SECTION THRU SOUTH DOORS A3.3 TRANSVERSE SECTION THRU NORTH DOORS AND SOUTH STOREFRONT A3.4 STOREFRONT WINDOW DETAIL; STOREFRONT SPECIFICATIONS; NORTH WALL DETAIL SECTION A3.5 COOLER SECTION AND WEST WALL DETAIL SECTION; COOLER SPECIFICATIONS A4.1 STEEL DETAILS; STEEL OPEN-WEB JOIST SPECIFICATIONS; GENERAL STEEL REQUIREMENTS A4.2 RESTROOM DETAIL PLAN AND OTHER INTERIOR ELEVATIONS A4.3 SPECIFICATIONS; ELECTRICAL GROUNDING SPECIFICATIONS; GROUNDING SCHEMATIC A4.4 ROOF EQUIPMENT SCREENING SPECIFICATIONS; SCREENING CUT SHEETS A4.5 ADA DETAILS A5.1 DUMPSTER AND SOUTH MASONRY WALL ELEVATIONS AND DETAILS A6.1 FUEL CANOPY PLANS AND STRUCTURAL DETAILS; FUEL CANOPY CONCRETE SPECIFICATIONS; PRE-ENGINEERED FUEL CANOPY SPECIFICATIONS A6.2 FUEL CANOPY ELEVATIONS; REFLECTED CEILING / LIGHTING PLAN; LIGHT CUT SHEETS A7.1 BUILDING SIGNAGE; GROUND SIGN; CANOPY SIGNAGE P1.1 SANITARY SEWER PLAN; PLUMBING SPECIFICATIONS P1.2 PLUMBING ISOMETRIC; DOMESTIC WATER DISTRIBUTION SPECIFICATIONS M1.1 MECHANICAL PLAN; MECHANICAL SPECIFICATIONS; MECHANICAL EQUIPMENT SCHEDULE E1.1 ELECTRICAL POWER PLAN; ELECTRICAL SPECIFICATIONS; RISER DIAGRAM E1.2 ELECTRICAL LIGHTING PLAN; EXTERIOR SCONCE LIGHT CUT SHEET CIVIL ENGINEERING DRAWING: C101 SITE DEVELOPMENT PLAN LANDSCAPE DRAWINGS: L1.0 SITE LANDSCAPE PLAN L2.0 LANDSCAPE NOTES AND DETAILS I I IREVISIONS:DRAWING COMPLETION DATE:4820 Buttonwood CrescentARCHITECT AIAGORDON CLARKIndianapolis, Indiana 46228Phone: 317 255-2546317 252-5573Fax: GClark4820@aol.comCONVENIENCE STORE / FOOD MARTVILLAGE OF WEST CLAYCARMEL, INDIANASOUTHWEST CORNER OFHARLESTON STREET AND TOWNE ROADOCTOBER 14, 2021 FOR PERMITTING AND CONSTRUCTION30'-8"14'-4"42'-3" 87'-3" 29'-0"14'-4"44'-0" 11'-4"16'-4"1'-4"50'-8"SCALE: 1/4" = 1'-0" FLOOR PLAN PRE-FABRICATED BEVERAGE COOLER 40'-8 1/8"7'-6"8'-5"SODA DISPENSER HAND SINK 8'-0" 2" GAP 15'-8 5/8"1'-0"58'-0"3'-0" FURRED, INSULATED WALLS FURRED WALL MEN'S RR WOMEN'S RR SEE DETAILS, SHEET A1.2 CMU INFILL WALLS ANODIZED STOREFTONT ANODIZED STOREFTONT 22'-2"8'-0"8'-0"4'-1"4'-1"8'-0"8'-0"10'-7" TYPICAL FURRED WALL 3 5/8" STEEL STUDS 24" O.C. 4" FIBERGLASS INSULATION .006 VISQUEEN 5/8" DRYWALL FREEZER BY OTHERS BY OTHERS 2" GAP 6"x6"x3/8" TUBE STEEL TYPICAL ALL COLUMNS 6"x6"x3/8" TUBE STEEL TYPICAL ALL COLUMNS 3 FALSE WINDOWS 3 FALSE WINDOWS TYPICAL FURRED WALL 3 5/8" STEEL STUDS 24" O.C. 4" FIBERGLASS INSULATION .006 VISQUEEN 5/8" DRYWALL 37'-4 3/4"2'-6"4 3/4"7'-8"4'-7 1/2"28'-3"5'-9 1/2"19'-4 3/8"19'-7 3/4"4 3/4"4'-0"4 3/4"12'-11 1/2"2'-6"4 3/4"R-19 R-19 5'-0 1/4"1'-4"21'-4 5/8"1'-10 5/8"87'-4" A1.1 1 A3.1 1 1 A3.1 1 A3.1 1 1 A3.2 A3.2 A3.3 A3.3 A3.4 1 1 A3.5 1 A3.5 1 1 A3.4 1 A3.4 A3.4 A3.4 2 2 I I IREVISIONS:DRAWING COMPLETION DATE:4820 Buttonwood CrescentARCHITECT AIAGORDON CLARKIndianapolis, Indiana 46228Phone: 317 255-2546317 252-5573Fax: GClark4820@aol.comCONVENIENCE STORE / FOOD MARTVILLAGE OF WEST CLAYCARMEL, INDIANASOUTHWEST CORNER OFHARLESTON STREET AND TOWNE ROADOCTOBER 14, 2021 FOR PERMITTING AND CONSTRUCTIONSCALE: 1/4" = 1'-0" FOUNDATION PLAN CONCRETE REQUIREMENTS AND SPECIFICATIONS: IT IS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO FOLLOW ALL APPLICABLE SAFETY CODES AND REGULATIONS DURING ALL PHASES OF CONSTRUCTION. SHOULD ANY OF THE DETAILED INSTRUCTIONS SHOWN ON THE PLANS CONFLICT WITH THESE STRUCTURAL NOTES, THE SPECIFICATIONS, OR WITH EACH OTHER, THE STRICTEST PROVISIONS SHALL GOVERN. GOVERNING CODES: INTERNATIONAL BUILDING CODE, 2008, WITH CURRENT INDIANA AMENDMENTS. FOUNDATIONS: NOTIFY THE ARCHITECT AS SOON AS POSSIBLE OF ANY UNUSUAL SOIL CONDITIONS, SUCH AS UNEXPECTED SPRING OR SEEPAGE WATER, OR SOIL OF QUESTIONABLE BEARING CAPACITY. ALL FOOTINGS SHALL BEAR ON FIRM UNDISTURBED SOIL OR ENGINEERED FILL WITH AN ALLOWABLE BEARING CAPACITY OF 2,000 POUNDS PER SQUARE FOOT. PERIMETER FOOTINGS SHALL BEAR A MINIMUM OF 3'-0" BELOW EXTERIOR GRADE. STEP FOOTINGS AS REQUIRED. WHERE UNDERGROUND UTILITIES ENTER OR EXIT THE BUILDING, STEP TOPS OF ALL FOOTINGS BELOW UTILITY INVERT ELEVATIONS. DESIGN NET SOIL PRESSURES SPREAD FOOTINGS: CONTINUOUS FOOTERS 2,000 PSI 1,500 PSI. BACKFILL AND FILL MATERIALS: PROVIDE SATISFACTORY SOIL MATERIALS FOR BACKFILL AND FILL, FREE OF CLAY, DEBRIS, WASTE, FROZEN MATERIALS, VEGETABLE AND OTHER DELETERIOUS MATTER. REINFORCED CONCRETE: ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH ACI 318-95, "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE". SPECIFICATIONS: IN GENERAL, COMPLY WITH ACI 301-96, "STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE". PLACEMENT AND CURING OF CONCRETE SHALL CONFORM TO ACI 305 "HOT WEATHER CONCRETING" AND ACI 306 "COLD WEATHER CONCRETING". ALL REINFORCING DETAILS SHALL CONFORM TO ACI 315-86, "MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES" UNLESS DETAILED OTHERWISE ON THE STRUCTURAL DRAWINGS. ALL DEFORMED REINFORCING BARS: ASTM A615, GRADE 60 ALL WELDED WIRE FABRIC:ASTM A185, DELIVERED IN FLAT SHEETS REINFORCING SUPPLIER SHALL PROVIDE ALL BAR ACCESSORIES, CHAIRS, AND SUPPORTS NECESSARY TO SECURE STEEL IN ACCORDANCE WITH "ACT CODE OF STANDARD PRACTICE". WHERE ANY STEPS IN FALL FOOTING ELEVATIONS OCCUR, PROVIDE MAXIMUM STEP OF ONE VERTICAL TO TWO HORIZONTAL. CONCRETE COVER: UNLESS OTHERWISE NOTED, DETAIL REINFORCING TO PROVIDE MINIMUM COVER AS FOLLOWS: CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH:3 INCHES CONCRETE EXPOSED TO EARTH OR WEATHER, #5 RE-BARS OR SMALLER: 1/2 INCHES ALL OTHER:2 INCHES 1 CONCRETE CONTRACTOR SHALL VERIFY SOIL BEARING PRIOR TO CONCRETE PLACEMENT. REPORT DEVIATIONS TO GENERAL CONTRACTOR AND ARCHITECT. CONCRETE IN THE FOLLOWING AREAS SHALL CONSIST OF NATURAL SAND FINE AGGREGATE AND NORMAL WEIGHT COARSE AGGREGATES CONFORMING TO ASTM C33, TYPE 1 PORTLAND CEMENT CONFORMING TO ASTM C150, AND SHALL HAVE THE FOLLOWING COMPRESSIVE STRENGTH AT 28 DAYS: FOOTINGS AND PADS: SLABS-ON-GRADE AND PIERS: 3,000 PSI 4,000 PSI RETAINING WALLS, CURBS, SIDEWALKS, AND SLABS EXPOSED TO DE- ICERS. 4,000 PSI (6% + 1% ENTRAINED AIR BY VOLUME) NO PART OF THE STRUCTURE SHALL BE PLACED ON FROZEN OR WET SOIL. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING THE FOUNDATION AND SOIL WITHIN THE BUILDING AREA FROM FREEZING DURING WINTER CONSTRUCTION. FOOTINGS AND PIERS: DOWELS IN FOOTINGS SHALL MATCH VERTICAL PIER REINFORCING. PROVIDE CORNER BARS AT FOOTING CORNERS TO MATCH HORIZONTAL REINFORCING. MINIMUM LENGTHS OF EACH LEG TO BE 45 BAR DIAMETERS. BACKFILL AGAINST BOTH SIDES OF WALLS EQUALLY UNTIL THE LOWER ELEVATION IS ATTAINED. BRACE ALL FOUNDATION WALLS BEFORE BACKFILLING AND COMPACTING. PROVIDE LEAN CONCRETE (CLASS IV) UNDER FOUNDATIONS FOR ACCIDENTAL OVER-EXCAVATION, SOFT SPOTS, AND TRENCHES. BUILT-IN WORK: INSTALL ALL ANCHORS, INSERTS, NOSINGS, REGLETS AND LIKE ITEMS FURNISHED BY OTHER TRADES FOR INSTALLATION IN CONCRETE WORK. ALL BUILT-IN ITEMS SHALL BE IN PROPER LOCATION AND SHALL BE SO MAINTAINED DURING THE PERFORMANCE OF CONCRETE WORK. SLEEVES, CONDUITS, PIPES AND LIKE ITEMS PASSING THROUGH FLOORS, WALLS, OR BEAMS SHALL BE OF SUCH SIZE OR IN SUCH LOCATION AS NOT TO IMPAIR UNDULY THE STRENGTH OF THE CONSTRUCTION. VAPOR BARRIER PLACEMENT: USE A CONCRETE MIXTURE WITH AN ADEQUATE CEMENT FACTOR - MINIMUM OF 5 1/2 BAGS PER CUBIC YARD. USE A SMALL AMOUNT OF AIR-ENTRAINMENT IN THE MIXTURE TO REDUCE BLEEDING - ABOUT 3% TO 5% AIR. EXTERIOR CONCRETE SHALL HAVE 5 1/2% AIR. PLACE CONCRETE AT LOWEST PRACTICAL SLUMP. A WATER-REDUCING ADMIXTURE MAY BE USED TO LOWER THE MIX WATER CONTENT, IF USED STRICTLY ACCORDING TO WRITTEN MANUFACTURER'S INSTRUCTIONS. PERIMETER INSULATION: A TOTAL OF FOUR FEET WIDTH OF PERIMETER INSULATION SHALL BE PUT IN PLACE. THIS CAN BE A COMBINATION OF HORIZONTAL AND VERTICAL RIGID INSULATION, AS SHOWN ON DRAWINGS. 4'-0" x 4'-0" x 1'-0" CONCRETE FOOTER PAD #5 REBARS 12" O.C. EACH WAY 24" x 24" CONCRETE COLUMN PIER 2'-0"8'-8"2'-0"9" 87'-4"50'-8"40'-11"1'-5"9"1'-5"29'-5" 27'-8"1'-5"9"2'-0"8'-8"2'-0"9"1'-5"42'-8"8"1'-0"4"2'-5"2'-11"8"8"4'-0"1'-4"7'-4"4" THICK CONCRETE FLOOR SEE SPECIFICATIONS COOLER FOOTPRINT SEE SPECIAL FLOOR DETAILS SEE SPECIAL FLOOR DETAILS FREEZER FOOTPRINT 1 A3.1 1 1 A3.1 1 A3.1 1 1 A3.2 A3.2 A3.3 A3.3 A3.4 1 1 A3.5 1 A3.5 1 1 A3.4 1 A3.4 A3.4 A3.4 2 2 A1.2 I I IREVISIONS:DRAWING COMPLETION DATE:4820 Buttonwood CrescentARCHITECT AIAGORDON CLARKIndianapolis, Indiana 46228Phone: 317 255-2546317 252-5573Fax: GClark4820@aol.comCONVENIENCE STORE / FOOD MARTVILLAGE OF WEST CLAYCARMEL, INDIANASOUTHWEST CORNER OFHARLESTON STREET AND TOWNE ROADOCTOBER 14, 2021 FOR PERMITTING AND CONSTRUCTIONACOUSTICAL CEILINGS: 1. PROVIDE ALL ACOUSTICAL CEILINGS COMPLETE WITH SUSPENSION SYSTEM AND RELATED ACCESSORIES AS SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. 2. STORE AND HANDLE TO PREVENT SOILING, DAMAGE OR WETTING. 3. INSTALL ALL ACOUSTIC CEILING AND SUSPENSION SYSTEMS IN STRICT ACCORDANCE WITH MANUFACTURER’S RECOMMENDATIONS. FINISHED CEILINGS SHALL BE LEVEL, WITH ALL JOINTS SNUG AND SQUARE. 4. SUSPENSION SYSTEM INSTALLATION SHALL COMPLY WITH ASTM C636 REQUIREMENTS AND BE WATER OR LASER LEVEL. 5. CEILING SUSPENSION SYSTEM SHALL BE SUPPORTED DIRECTLY FROM THE BUILDING STRUCTURE. PROVIDE ADDITIONAL SUPPORT FRAMING AS REQUIRED. PROVIDE SUPPORT AT ALL FOUR (4) CORNERS OF FLUORESCENT LIGHT FIXTURES. 6. PROVIDE WALL ANGLE MOLDING AT PERIMETER OF ALL CEILING TILE INSTALLATIONS. ANCHOR MOLDING TO WALL AT EACH POINT OF MAIN RUNNER AND CROSS TEE BEARINGS AND ADDITIONALLY AS REQUIRED TO PREVENT MOLDING FROM SAGGING OR TWISTING. 7. INSTALL CEILING TO PERMIT BORDER UNITS OF THE GREATEST POSSIBLE SIZE. 8. COORDINATE WORK WITH ELECTRICAL PLANS AND/OR ELECTRICAL SUB-CONTRACTOR TO CONFIRM LIGHT FIXTURES ARE CORRECTLY LOCATED. 9. IF REQUIRED IN THIS PROJECT, COORDINATE WORK WITH SPRINKLER SYSTEM INSTALLER. 10. REMOVE AND REPLACE UNITS, WHICH ARE DAMAGED OR IMPROPERLY INSTALLED. 11. CLEAN PAINTED SURFACES DAMAGED BY WORK OF THIS INSTALLATION. SCALE: 1/4" = 1'-0" REFLECTED CEILING PLAN TYPICAL 24"x24" DIFFUSER TYPICAL 24"x24" LED FIXTURE 24"x 48" LED PANEL FIXTURE LAY-IN ACOUSTIC TILE CEILING AT 10'-0" AFF LAY-IN ACOUSTIC TILE CEILING AT 10'-0" AFF LAY-IN ACOUSTIC TILE CEILING AT 10'-0" AFF LAY-IN ACOUSTIC TILE CEILING AT 10'-0" AFF GENERAL NOTES – BULKHEADS CEILING, SOFFIT AND BULKHEAD FRAMING SYSTEMS SHALL BE DESIGNED TO CARRY CEILING DEAD LOADS IN ADDITION TO FRAMING MEMBERS, LIGHT FIXTURES, AIR DIFFUSERS, SPEAKERS, INSULATION, AND SIGNAGE, ETC. BLOCKING AND FRAMING SHALL BE 2X4 MINIMUM AND BE 16” O.C. FRAMING. IT MAY BE 24”” O.C. IF ATTACHED TO PRE-ENGINEERED WOOD TRUSSES, AND NOTICE OF THE BULKHEAD CONDITION IS A PART OF THE TRUSS DESIGN AND SPECIFICATIONS. POSITIVE TENSION-TYPE CONNECTIONS BACK TO STRUCTURE IS REQUIRED. UNISTRUT TYPE METAL CONNECTIONS OR EQUAL. DRYWALL SHALL BE 5/8” TYPE X. STRICTLY FOLLOW RECOMMENDATIONS OF THE USG CORPORATION AND THE NATIONAL GYPSUM COMPANY’S GOLD BOND BUILDING PRODUCTS DIVISION. ALL ACCESSORIES, INCLUDING SIMPSON JOIST HANGERS, CLIPS, SCREWS, AND NAILS ETC. SHALL BE PER ROUGH FRAMING SPECIFICATIONS THAT ARE A PART OF THESE CONTRACT DOCUMENTS. EXECUTION: ARRANGE FRAMING FOR CEILINGS TO PROVIDE SUPPORT INDEPENDENT OF WALLS, COLUMNS, PIPES, AND DUCTS AND INSTALL ALL WORK PLUMB. NOTIFY ARCHITECT IF ANY QUESTIONS ON STRUCTURAL ATTACHMENT ARISE. 8'-0" AFF OR PER COOLER MFGR. MINIMUM 24" x 30" ATTIC ACCESS 1 A3.1 1 1 A3.1 1 A3.1 1 1 A3.2 A3.2 A3.3 A3.3 A3.4 1 1 A3.5 1 A3.5 1 1 A3.4 1 A3.4 A3.4 A3.4 2 2 A1.3 I I IREVISIONS:DRAWING COMPLETION DATE:4820 Buttonwood CrescentARCHITECT AIAGORDON CLARKIndianapolis, Indiana 46228Phone: 317 255-2546317 252-5573Fax: GClark4820@aol.comCONVENIENCE STORE / FOOD MARTVILLAGE OF WEST CLAYCARMEL, INDIANASOUTHWEST CORNER OFHARLESTON STREET AND TOWNE ROADOCTOBER 14, 2021 FOR PERMITTING AND CONSTRUCTIONSCALE: 1/4" = 1'-0" ROOF FRAMING PLAN CANTILEVER JOIST ENDS HERE MECHANICAL WALK-DECK ALLOW FOR THREE HVAC UNITS OF 500# EACH BRACING AS REQUIRED G.C AND STEEL SUPPLIER SHALL VERIFY ACTUAL EQUIPMENT 30 K 90 / 50 24" O.C.W18 x 46 W18 x 46 W18 x 46 30 K 90 / 50 24" O.C.W18 x 46 W18 x 46 W18 x 46 MINIMUM BRIDGING: 1 1/2" x 7/64" OR R = .35 MAX. SPACING 9'-8" O.C. MINIMUM BRIDGING: 1 1/2" x 7/64" OR R = .35 MAX. SPACING 9'-8" O.C. BRIDGING DETAILS NOTE: FINAL DESIGN SHALL BE THE RESPONSIBILITY OF THE STEEL JOIST SUPPLIER. CONSULT ARCHITECT FOR REQUIRED INFORMATION, IF NEEDED. A1.4 1 A3.1 1 1 A3.1 1 A3.1 1 1 A3.2 A3.2 A3.3 A3.3 A3.4 1 1 A3.5 1 A3.5 1 1 A3.4 1 A3.4 A3.4 A3.4 2 2 I I IREVISIONS:DRAWING COMPLETION DATE:4820 Buttonwood CrescentARCHITECT AIAGORDON CLARKIndianapolis, Indiana 46228Phone: 317 255-2546317 252-5573Fax: GClark4820@aol.comCONVENIENCE STORE / FOOD MARTVILLAGE OF WEST CLAYCARMEL, INDIANASOUTHWEST CORNER OFHARLESTON STREET AND TOWNE ROADOCTOBER 14, 2021 FOR PERMITTING AND CONSTRUCTIONSCALE: 1/4" = 1'-0" ROOF PLAN FIRESTONE TPO MECHANICALLY ADHERED ROOFING OR EQUAL ALUMINUM WALKABLE EQUIPMENT DECK SLOPE MIN. 1 : 12SLOPE MIN. 1 : 12ROOF EQUIPMENT SCREENING SEE DETAILS ROOF EQUIPMENT SCREENING SEE DETAILS GATE BY ROOF SCREENING MANUFACTURER GATE BY ROOF SCREENING MANUFACTURER 5'-0" WIDE 5'-0" WIDE TPO ROOFING GENERAL NOTES: MISCELLANEOUS: Any additional work such as changes to specified materials, applications or processes, or other architectural features requiring decisions and not certified by Gordon Clark must be promptly proposed by letter or email (gclark4820@aol.com). ROOFING MATERIAL: Proposed manufacturer: Firestone UltraPly TPO Membrane, mechanically attached to steel deck. ROOF SCUPPERS: Strictly follow drawings and recommendations by Firestone TPO thru-wall Platinum TPO Coated Metal Scuppers. REQUIREMENTS: Provide a minimum 1: 12 roof slope. Steel deck shall be a minimum 22 ga. Thickness. Fastener Type: Firestone Heavy Duty Plus Insulation Adhesive: Spray R insulation adhesive. Verify if steel deck must be cleaned to meet Firestone requirements. Adhesive Attachment: Full Application I.S.O. Spray S Insulation Adhesive. Membrane Requirement: UltraPly Platinum TPO. Thickness 0.080”. Seaming Requirement: Contractor’s option as long as it meets Firestone standards. Membrane Attachment: Maximum 12 ft. row spacing, fasteners spaced maximum 6 o.c. Edge Metal System: Firestone Coping System or as recommended otherwise by Firestone. EDGE OF ROOFING: CANT STRIP AS APPROVED BY FIRESTONE TPOEDGE OF ROOFING: CANT STRIP AS APPROVED BY FIRESTONE TPOEDGE OF ROOFING: CANT STRIP AS APPROVED BY FIRESTONE TPOEDGE OF ROOFING: CANT STRIP AS APPROVED BY FIRESTONE TPO 1 A3.1 1 A3.1 1 A3.2 A3.3 1 A3.5 1 A3.5 1 1 A3.4 1 A3.4 A3.4 A3.4 2 2 1 1 A3.1 1 A3.2 A3.3 A3.4 1 A1.5 I I IREVISIONS:DRAWING COMPLETION DATE:4820 Buttonwood CrescentARCHITECT AIAGORDON CLARKIndianapolis, Indiana 46228Phone: 317 255-2546317 252-5573Fax: GClark4820@aol.comCONVENIENCE STORE / FOOD MARTVILLAGE OF WEST CLAYCARMEL, INDIANASOUTHWEST CORNER OFHARLESTON STREET AND TOWNE ROADOCTOBER 14, 2021 FOR PERMITTING AND CONSTRUCTIONCODE SUMMARY: CONVENIENCE STORE, VILLAGE OF WEST CLAY, INDIANA BUILDING TYPE: BUILDING: TYPE II-B UNSPRINKLED BUILDING OCCUPANCY: M MERCANTILE, UNSPRINKLED SQUARE FOOTAGE ALLOWED: PER TABLE 503: TYPE II-B MERCANTILE = 12,500 SF, 2 STORIES ACTUAL SQUARE FOOTAGE: BUILDING FOOTPRINT: 4,525 SF, 1 STORY OCCUPANCY LOAD: PER TABLE 1004.1.2: OCCUPANCY BASED ON CONDITIONED SPACE. THIS OCCUPANCY ELIMINATES THE COOLERS FROM REQUIRED BUILDING OCCUPANCY. CONDITIONED SPACE = 3,345 30 SF GROSS PER PERSON = 112 PEOPLE BUILDING EGRESS, CHAPTER 10: MINIMUM EGRESS REQUIRED: PER SECTION 1015 M OCCUPANCY – 112 PEOPLE REQUIRES TWO ADA EXITS. TWO PROVIDED. SEE PLANS. EXIT DISCHARGE, CHAPTER 10: ALL EXITS LEAD TO AN ADA STOOP AND ARE PROVIDED WITH LIGHTED EXIT SIGNAGE. TRAVEL DISTANCE IS WELL UNDER 200 FEET. EXIT SIGNAGE: EXIT SIGNS SHALL MEET OR EXCEED SECTION 1011. FIRE EXTINGUISHERS: FIRE EXTINGUISHER SHALL BE INSTALLED AS SHOWN IN THE PLANS, PER TABLE 906.3 OF THE INTERNATIONAL FIRE CODE, AND PER NFPA 10. 1 CLASS ABC EXTINGUISHER AND 1 K TYPE REQUIRED.56'-2 1/2"47' -5 7 /8 "50'-3 7/8"14'-0 1/2"LIFE SAFETY PLAN SCALE: 1/4" = 1'-0" LS1.1 K TYPE FIRE EXTINGUISHER 35'- 7" 7'-2 1/8"19'-1 7/8"10'-8 5/8" 25' - 3 1 / 4 "28'-5 5/8" ABC TYPE EXT. I I IREVISIONS:DRAWING COMPLETION DATE:4820 Buttonwood CrescentARCHITECT AIAGORDON CLARKIndianapolis, Indiana 46228Phone: 317 255-2546317 252-5573Fax: GClark4820@aol.comCONVENIENCE STORE / FOOD MARTVILLAGE OF WEST CLAYCARMEL, INDIANASOUTHWEST CORNER OFHARLESTON STREET AND TOWNE ROADOCTOBER 14, 2021 FOR PERMITTING AND CONSTRUCTIONWEST ELEVATION SOUTH ELEVATION SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" FACE BRICK METAL COPING EXTERIOR 12" x 12' TILE TOWER COLOR: BLUE AS SELECTED BY ARCHITECT EXTERIOR TILE LEDGE COLOR: BLUE AS SELECTED BY ARCHITECT EXTERIOR TILE WATERTABLE COLOR: BLUE AS SELECTED BY ARCHITECT METAL COPING TILE MEDALIAN AS SELECTED BY ARCHITECT ROOFTOP EQUIPMENT SCREENING SEE DETAILS EFIS EXTERIOR LIGHT FIXTURES MODERN FORMS "SKYSCRAPER" EXTERIOR LIGHT FIXTURES MODERN FORMS "SKYSCRAPER" SECURITY ACCESS LADDER NO ELEMENT IS TOWARD THE GROUND WITHOUT BEING UNLOCKED EXTERIOR TILE LEDGE COLOR: BLUE AS SELECTED BY ARCHITECT EXTERIOR TILE WATERTABLE COLOR: BLUE AS SELECTED BY ARCHITECT TILE MEDALIAN AS SELECTED BY ARCHITECT FACE BRICK SOLDIER COURSE A2.1 I I IREVISIONS:DRAWING COMPLETION DATE:4820 Buttonwood CrescentARCHITECT AIAGORDON CLARKIndianapolis, Indiana 46228Phone: 317 255-2546317 252-5573Fax: GClark4820@aol.comCONVENIENCE STORE / FOOD MARTVILLAGE OF WEST CLAYCARMEL, INDIANASOUTHWEST CORNER OFHARLESTON STREET AND TOWNE ROADOCTOBER 14, 2021 FOR PERMITTING AND CONSTRUCTIONSCALE: 1/4" = 1'-0" EAST ELEVATION NORTH ELEVATION SCALE: 1/4" = 1'-0" FACE BRICK METAL COPING EXTERIOR 12" x 12' TILE TOWER COLOR: BLUE AS SELECTED BY ARCHITECT EXTERIOR TILE LEDGE COLOR: BLUE AS SELECTED BY ARCHITECT EXTERIOR TILE WATERTABLE COLOR: BLUE AS SELECTED BY ARCHITECT METAL COPING SECURITY TYPE ACCESS LADDER THIS SECTION FOLDS UP A2.2 SCALE: 1/2" = 1'-0" 1 I I IREVISIONS:DRAWING COMPLETION DATE:4820 Buttonwood CrescentARCHITECT AIAGORDON CLARKIndianapolis, Indiana 46228Phone: 317 255-2546317 252-5573Fax: GClark4820@aol.comCONVENIENCE STORE / FOOD MARTVILLAGE OF WEST CLAYCARMEL, INDIANASOUTHWEST CORNER OFHARLESTON STREET AND TOWNE ROADOCTOBER 14, 2021 FOR PERMITTING AND CONSTRUCTIONW18 x 46 W18 x 46 OPEN WEB STEEL JOISTS 30 K 90 / 50 24" O.C. 4" RIGID INSULATION CORRIGATED STEEL ROOF DECK WMP-10 R-40 VINYL LINED INSULATION 12" SOLID CMU'S 2'-4"1'-0"2'-8"MINUMUM TOTAL OF 4'-0" RIGID INSULATION 2" THICK TYPICAL ALL EXTERIOR FOUNDATIONS RIGID INSULATION "HOG-BACK" AT EACH SCUPPER TOP OF MASONRY 16'-0" AFF 17'-10"TOP OF HIGH SCREEN WALL TOP OF LOW SCREEN WALL1'-8"1'-10"19'-8" AFF 17'-10" AFF 19'-8"EXTERIOR TILE LEDGE COLOR: BLUE AS SELECTED BY ARCHITECT EXTERIOR TILE WATERTABLE COLOR: BLUE AS SELECTED BY ARCHITECT STANDARD FACE BRICK STANDARD FACE BRICK STANDARD FACE BRICK STD. 8" CMU'S SOLDIER COURSE TILE DIAMOND PANEL STEEL STUD FURRING TYPICAL FURRING 3 5/8" STEEL STUDS 24" O.C .006 VISQUEEN 5/8" DRYWALL 2'-4"1'-0"2'-8"W18 x 46 TOP OF MASONRY 16'-0" AFF TPO ROOFING. SEE SPECS AND CUT SHEET TRANSVERSE SECTION SHOWING TYPICAL WALLS A3.1 A3.1 4" THICK CONCRETE SLAB. SEE SPECS. MIN. 4" COMPACTED FILL I I IREVISIONS:DRAWING COMPLETION DATE:4820 Buttonwood CrescentARCHITECT AIAGORDON CLARKIndianapolis, Indiana 46228Phone: 317 255-2546317 252-5573Fax: GClark4820@aol.comCONVENIENCE STORE / FOOD MARTVILLAGE OF WEST CLAYCARMEL, INDIANASOUTHWEST CORNER OFHARLESTON STREET AND TOWNE ROADOCTOBER 14, 2021 FOR PERMITTING AND CONSTRUCTIONSCALE: 1/2" = 1'-0" 1 TRANSVERSE SECTION THRU SOUTH ENTRY DOORS OPEN WEB STEEL JOISTS 30 K 90 / 50 24" O.C. 4" RIGID INSULATION CORRIGATED STEEL ROOF DECK WMP-10 R-40 VINYL LINED INSULATION RIGID INSULATION "HOG-BACK" AT EACH SCUPPER 2' x 2' LAY-IN ACOUSTIC CEILING AT 10'-0" AFF BEVERAGE COOLER DOORS SEE SPECIFICATIONS RESTROOM DOOR CLOSER PRIVACY SET SIGNAGE ADA SIGNAGE RESTROOM DOOR CLOSER PRIVACY SET SIGNAGE ADA SIGNAGE MINUMUM TOTAL OF 4'-0" RIGID INSULATION 2" THICK 4" THICK CONCRETE SLAB. SEE SPECS. MIN. 4" COMPACTED FILL 2'-0"1'-0"2'-8"3 COURSES OF 12" SOLID CMU'S 4" SIDEWALK SEE CIVIL DRAWINGS SLOPE SLIGHTLY AWAY FROM BUILDING TYPICAL ALL EXTERIOR FOUNDATIONS STOREFRONT ENTRANCE SYSTEM TOP OF MASONRY 16'-0" AFF 17'-10"TOP OF HIGH SCREEN WALL TOP OF LOW SCREEN WALL1'-8"1'-10"19'-8" AFF 17'-10" AFF 19'-8"EXTERIOR TILE LEDGE COLOR: BLUE AS SELECTED BY ARCHITECT EXTERIOR TILE WATERTABLE COLOR: BLUE AS SELECTED BY ARCHITECT STANDARD FACE BRICK STANDARD FACE BRICK STANDARD FACE BRICK STD. 8" CMU'S SOLDIER COURSE TILE DIAMOND PANEL STEEL STUD FURRING TYPICAL FURRING 3 5/8" STEEL STUDS 24" O.C .006 VISQUEEN 5/8" DRYWALL 2'-4"1'-0"2'-8"W18 x 46 W18 x 46 EXTEND JOISTS INTO ENTRANCE PITCH POCKET OR OTHER APPROVED CONNECTION EXTEND INSULATION 6" STEEL STUDS 16" O.C. R-19 FIBERGLASS INSULATION EFIS FINISH SURFACE GALVANIZED 6" 20 GA. STEEL STUD FRAMING 1 :12 SLOPE METAL COPING ROOF EQUIPMENT SCREENING SEE DETAILS TOP OF EFIS 25'-8" AFF TPO ROOFING. SEE SPECS AND CUT SHEET A3.2 A3.2 I I IREVISIONS:DRAWING COMPLETION DATE:4820 Buttonwood CrescentARCHITECT AIAGORDON CLARKIndianapolis, Indiana 46228Phone: 317 255-2546317 252-5573Fax: GClark4820@aol.comCONVENIENCE STORE / FOOD MARTVILLAGE OF WEST CLAYCARMEL, INDIANASOUTHWEST CORNER OFHARLESTON STREET AND TOWNE ROADOCTOBER 14, 2021 FOR PERMITTING AND CONSTRUCTIONSCALE: 1/2" = 1'-0" 1 TRANSVERSE SECTION THRU NORTH ENTRY DOOR OPEN WEB STEEL JOISTS 30 K 90 / 50 24" O.C. 4" RIGID INSULATION CORRIGATED STEEL ROOF DECK WMP-10 R-40 VINYL LINED INSULATION RIGID INSULATION "HOG-BACK" AT EACH SCUPPER 2' x 2' LAY-IN ACOUSTIC CEILING AT 10'-0" AFF TOP OF MASONRY 16'-0" AFF 17'-10"TOP OF HIGH SCREEN WALL TOP OF LOW SCREEN WALL1'-8"1'-10"19'-8" AFF 17'-10" AFF 19'-8"BEVERAGE COOLER DOORS SEE SPECIFICATIONS MINUMUM TOTAL OF 4'-0" RIGID INSULATION 2" THICK 4" THICK CONCRETE SLAB. SEE SPECS. MIN. 4" COMPACTED FILL 1'-0"2'-8"3 COURSES OF 4" SIDEWALK SEE CIVIL DRAWINGS SLOPE SLIGHTLY AWAY FROM BUILDING TYPICAL ALL EXTERIOR FOUNDATIONS TWO #5 REBARS CONTINUOUS TYPICAL 1'-0"2'-8"SOLDIER COURSE 8" CMU'S AT ENTRANCE AREAS 3 COURSES OF 12" SOLID CMU'S TWO #5 REBARS CONTINUOUS TYPICAL 2'-4" BULKHEAD ATTACHED WITH UNISTRUT TO JOISTS SECURITY GLASS BY OTHERS IF OWNERS DECIDE TO INSTALL IT 8'-0" AFF FOOD AND BEVERAGE COUNTERS CASEWORK BY OTHERS LAY-IN CEILING STOREFRONT SYSTEM SEE SPECIFICATIONS TOS ROOFING. SEE SPECS AND CUT SHEET 12 1 STD. BRICK LEDGE W/ REQUIRED FLASHING ADA PULL-OUT A3.3 A3.3 I I IREVISIONS:DRAWING COMPLETION DATE:4820 Buttonwood CrescentARCHITECT AIAGORDON CLARKIndianapolis, Indiana 46228Phone: 317 255-2546317 252-5573Fax: GClark4820@aol.comCONVENIENCE STORE / FOOD MARTVILLAGE OF WEST CLAYCARMEL, INDIANASOUTHWEST CORNER OFHARLESTON STREET AND TOWNE ROADOCTOBER 14, 2021 FOR PERMITTING AND CONSTRUCTIONEPDM ROOFING. SEE SPECIFICATIONS 4" RIGID INSULATION CORRIGATED STEEL ROOF DECK OPEN WEB STEEL JOISTS 30 K 90 / 50 24" O.C. WMP-10 R-30 VINYL LINED INSULATION ROOF EQUIPMENT SCREENING SEE SPECS. AND OTHER DRAWINGS LAY-IN CEILING AT 10'-0" AFF BOND BEAM WITH TWO CONTINUOUS #5 REBARS R-19 FIBERGLASS INSULATION 3 5/8" STEEL STUDS SPECIFICATIONS AND REQUIREMENTS FOR STOREFRONT AND ENTRANCE SYSTEMS: This section includes windows and entrance systems. Basis of Design and Standards: Aluminum Framing Systems: Kawneer TRIFAB VG (VERSA GLAZE) 451, (2” sight line) Aluminum Entrance Doors: Kawneer 190 Narrow Stile with Finger Guards Note: Interior and one exterior door are part of this work. Frame Depth:4 ½” Glass and Glazing: Outside glazing: 1” insulated low E glazing (1/4” outside, ½” spacer, ¼” inside glass.) Interior glazing: ¼” tempered clear plate Glaze to front. Glazing materials shall be compatible with aluminum and shall be as recommended by manufacturer. Glazing methods o Exterior: Elastomeric gasket and in accordance with manufacturer’s standards. o Interior: Snap-in type 0.062 aluminum glazing beads and a compression wedge of dense elastomer. Operable windows: o Provide and install two (2) operable windows for ventilation compatible with the storefront system. Provide shop drawings or cut sheets for architect and/or owner review. Stick fabrication, manufacturer’s standard parts and entrance systems. Include SSG/Weather seal option Include end-dams with sill flashing. Use concealed flashing, minimum 26 gage dead-soft stainless steel, or .026” minimum extruded aluminum of alloy and type compatible with adjacent materials. Perimeter anchors: Aluminum. All storefront metal to be clear anodized finish. Exterior framing to be set in head receptor, bottom sill starter, set in caulk bed. All framing to include perimeter caulking on interior and exterior sides. Include all required sealants, with products selected for their intended use and adjacent materials. Use tempered glass where required by state and local codes and ordinances. G.C. to provide solid wood blocking at heads/jambs for frame anchoring. Head lintel to be self supportive, non-load-bearing, by G.C. Field Measurements: G.C. shall advise storefront sub-contractor when field measurements may be made in a timely fashion. Verify by field measurements prior to fabrication. Keep a record of field measurements. Storage: Store products in manufacturer’s packaging unopened until ready for installation. Store protected from soaking water, corrosion, and other damaging causes. Entrance Systems: Rails affixed to stiles utilizing threaded through-bolt with concealed fasteners. Water-rated bumper threshold, ADA compliant. Hardware: 4” butt hinges, 1 or 2 pair determined by specified height. 3 point locking mechanism on active leaf, 2 point on inactive leaf. Keyed cylinder with thumb-turn on interior of active leaf. ADA compliant panic strike with tubular push/pull. Glazing: Wet seal exterior with structural silicone per manufacturer’s written instructions. Weather Stripping: Manufacturer’s specified weather stripping installed strictly in accordance with manufacturer’s written instructions. Installation: Installation shall be complete as intended for building use. Protect work from damage during entire course of construction. Install all storefront and entrance units plumb, level, and true to line without warp or rack of frames or sash with manufacturer’s prescribed tolerances. Weathertight Construction: Install sill members and other members in a bed of sealant or with joint filler or gaskets, to provide weathertight construction. Coordinate installation with wall flashings and other components of construction. Provide support and anchor in place. Provide all required accessories for a complete installation. Adjust swing doors for operation in accordance with manufacturer’s written instructions. Clean in accordance with manufacturer’s written instructions. Remove temporary coverings and protection of adjacent work areas. Repair or replace damaged installed products. Warranties: Frames Warranty: Two (2) years from Date of Substantial Completion. Submit manufacturer’s standard written warranty for Owner’s acceptance. Insulating Glass: Warranted to be free from defects (excluding breakage) for a period of five (5) years. Submit standard written warranty for Owner’s acceptance. EXTERIOR TILE WATERTABLE COLOR: BLUE AS SELECTED BY ARCHITECT STANDARD FACE BRICK ALUM. ANODIZED STOREFRONT 2'-6"7'-3"EXTERIOR TILE LEDGE COLOR: BLUE AS SELECTED BY ARCHITECT SOLDIER COURSE STD. 8" CMU'S STANDARD FACE BRICK BOND BEAM #5 REBAR CONTINUOUS TOP OF MASONRY 16'-0" AFF 4" CONCRETE FLOOR SLAB MINUMUM TOTAL OF 4'-0" RIGID INSULATION 2" THICK TYPICAL ALL EXTERIOR FOUNDATIONS 2'-4"1'-0"2'-8"TWO CONTINUOUS #5 REBARS 12" SOLID CMU'S TYPICAL AT BRICK CONDITIONS SOLID 8" CMU 14'-8" TOM CONTINUOUS FLASHING PER MASONRY STANDARDS EXTERIOR TILE LEDGE COLOR: BLUE AS SELECTED BY ARCHITECT STANDARD FACE BRICK STANDARD FACE BRICK STD. 8" CMU'S SOLDIER COURSE TILE DIAMOND PANEL STEEL STUD FURRING HORIZONTAL REINF. EACH THIRD CMU COURSE EXTERIOR TILE LEDGE COLOR: BLUE AS SELECTED BY ARCHITECT EXTERIOR TILE WATERTABLE COLOR: BLUE AS SELECTEDBY ARCHITECT STANDARD FACE BRICK OPEN WEB STEEL JOISTS 30 K 90 / 50 24" O.C. TOP OF MASONRY 16'-0" AFF 14'-8" TOM 2'-6" AFF TOM 7'-3" AFF TOM 10'-0 1/2" TOM HOG-BACK OR CRICKET SLOPED TO SCUPPER. SEE ROOF PLAN. HORIZONTAL REINFORCING EVERY 2'-0" VERTICALLY STANDARD MASONRY BRICK-LEDGE FLASHING MINUMUM TOTAL OF 4'-0" RIGID INSULATION 2" THICK TYPICAL ALL EXTERIOR FOUNDATIONS TWO CONTINUOUS #5 REBARS 12" SOLID CMU'S TYPICAL AT BRICK CONDITIONS SOLID 8" CMU SCALE: 1" = 1'-0" 1 SECTION THRU SOUTH STOREFRONT WINDOWS SCALE: 1" = 1'-0" SECTION THRU TYP. NORTH WALL 1'-3" 1'-3" MAIN BEAM CL MAIN BEAM CL A3.4A3.4A3.4 2 I I IREVISIONS:DRAWING COMPLETION DATE:4820 Buttonwood CrescentARCHITECT AIAGORDON CLARKIndianapolis, Indiana 46228Phone: 317 255-2546317 252-5573Fax: GClark4820@aol.comCONVENIENCE STORE / FOOD MARTVILLAGE OF WEST CLAYCARMEL, INDIANASOUTHWEST CORNER OFHARLESTON STREET AND TOWNE ROADOCTOBER 14, 2021 FOR PERMITTING AND CONSTRUCTIONNOTE: THIS COOLER SYSTEM SHALL BE A PRE-ENGINEERED UNIT FULLY OPERATIONAL. IT SHALL BE INSTALLED STRICTLY ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS. INSTALLATION SHALL PREFERABLY BE BY THE MANUFACTURER'S SERVICE REPRESENTATIVES. THIS SHALL MEET ALL STATE AND LOCAL BUILING CODES. CONSULT ARCHITECT WITH ANY QUESTIONS OR UNUSUAL CONDITIONS ENCOUNTERED. THE BASIS OF DESIGN IS "U.S. COOLER COMPANY" 2"x6" REDWOOD (THERMAL-BREAK; AROUND PERIMETER AND DIVIDING WALLS) VINYL SCREEDING OR 2"x2" ALUM. ANGLE 6 MIL. VAPOR BARRIER TAPE ALL JOINTS COOLER WALL PANEL 4" CONCRETE SLAB 4" COMPACTED FILL 4" INSULATION OR COOLER FLOOR PROVIDED BY COOLER MFGR. TYPICAL EXTERIOR WALL SEE OTHER DETAILS SCALE: 1" = 1'-0" 1 SECTION THRU COOLER OPEN-WEB STEEL JOISTS 24" O.C. SEE OTHER DETAILS AND SPECIFICATIONS UNISTRUT HANGERS FOR ALL BULKHEADS 3 5/8" STEEL STUDS 24" O.C. 5/8" DRYWALL SURFACE SUSPENDED ACOUSTIC CEILING AT 10'-0" AFF 3 5/8" STEEL STUDS 24" O.C. 5/8" DRYWALL SURFACE TYPICAL BULKHEAD WALK-IN COOLER SPECIFICATIONS: Refrigeration A) Walk-in Refrigerator and Freezer Construction 1) General: Each panel shall consist of inner and outer metal skins, a 4” insulation core, and be equipped with cam-action locking devices. The locking devices shall be operable from inside the walk-in. Construction shall be as approved by the NSF International and shall bear the NSF® Seal of Approval. All panels shall be connected to one another by placing the tongue of the insulation core of one panel into the groove of the core insulation of the adjacent panel. The resultant tongue and groove joint shall be sealed at both sides by double barreled NSF® approved gaskets. In order to avoid future swelling and mold formation, no wood shall be permitted in the manufacture of the tongue and groove panel profile. (a) Wall Panels: Panel insulation shall be 4” thick, high quality, extruded polystyrene or foamed-in-place polyurethane, modular panels joined by not less than three (3) cam-lock devices; gasket to seal between panels; R-28 or greater for refrigerators and R-32 or greater for freezers. (b) Ceiling: Panel insulation shall be 4” thick, high quality, extruded polystyrene or foamed-in-place polyurethane, modular panels joined by not less than three (3) cam-lock devices; gasket to seal between panels; R-28 or greater for refrigerators and R-32 or greater for freezers. (a) Sloped Roof Package: When specified. For use on walk-ins installed outdoors. May be required at certain snow loads. In order to form a sloped roof profile, suitable quantities of sloped foam shall be provided. The foam shall be cut in a manner that upon installation, a ¼”:1’ slope is obtained. The membrane roof shall be increased in size appropriately, in order to provide the additional material required to properly cover the resultant profile. (b) Roof panels shall be rated to withstand up to 90 mph winds. (c) Finishes: (i) Exterior Finishes: (a) 26 gauge tan stucco embossed galvanized steel (ii) Interior Finishes (a) Wall Panels: i. 26 gauge stucco embossed galvalume (b) Ceiling Panels: i. 26 gauge stucco embossed galvalume (c) Floors: i. 22 gauge smooth stainless steel (d) Panel Dimensions: As required for layout. 2) Doors: R-25 or greater for refrigerators; R-32 or greater for freezers. Door shall be flush mounted, positioned and hinged; provided with suitable sweep and magnetic gaskets, door closer, one pre-wired vapor proof light fixture, light switch with pilot light, dial thermometer, manual internal lock override, chrome plated cam lift hinges, chrome plated door latches with strike. (i) Outdoor Units: Doors on outdoor walk-ins shall have weather protected light switch and door drip cap. (ii) Freezer Doors: Freezer doors shall be identical to cooler doors, but with the addition of UL approved heater wire on all four sides. Freezer doors shall include a heated pressure relief port in the adjacent panel. (b) Thermometer: See item specification for thermometers required for this project: Thermometer installed flush-mount on hinge side of door panel. (c) Digital Thermometer (optional): 3” round digital thermometer with probe, installed flush-mount on hinge side of door panel. (d) Digital Thermometer with Alarm (optional): Specifications available. 3) Pressure Relief Port: Provide heated relief port in freezers. 4) Lights: Per owner’s requirements. (a) Fluorescent: 4’ vapor proof; optional per customer specification. (b) Incandescent: Single bulb, vapor proof; installed on door panel. (c) LED: Single bulb or 4’ vapor proof; optional per customer specification. 5) Installation: Dealer to install walk-in units. (a) Drawings and Instructions: Manufacturer shall supply a set of installation instructions and lay-out drawing. All panels shall have panel identification corresponding with the lay-out drawing to facilitate rapid and accurate field erection. B) Refrigeration System: Complete operating system consisting of a condensing unit and a evaporator coil. 1) Condensing Unit: General: Condenser fan motors of under 1 h.p. must use electronically commutated (EC) motors or permanent split capacitator-type (PSP) motors; splash lubrication system using Mobil EAL Arctic 22 polyester synthetic refrigeration oil; oil sight glass; removable oil drain plug; label indicating oil used; (a) high/low pressure control; suction line filter; suction and discharge service valves and copper/brass vibration isolators; receiver with fusible plug or relief valve; liquid line shut-off valve; sight glass; molecular sieve filter dryer; main power supply fused disconnect switch (b) Outdoor: Weather proof housing; crank case heater and low ambient temperature controls required to insure proper and efficient operation; fan cycling controls where ambient temperatures do not fall below -15°; head master valve and oversized, heated, insulated receiver and lines where ambient temperatures fall below -15°F. 2) Evaporator Coil: Forced convection style; match to condensing unit and suspend with air discharged parallel to the ceiling; lifetime sealed motors with inherent motor protection; evaporator fan motors of under 1 hp and less than 460 volts must use electronically commutated (EC) motors; enclose coil section and fans within aluminum housing (a) Refrigerator: Air defrost (b) Freezer and Low Temperature Refrigerator: Electric heater and controls for positive automatic defrost (c) Installation: Hang using plastic or nylon fasteners; spread coil weight evenly over ceiling panels; support long span ceiling panels as required. STEEL FINAL DESIGN SHALL BE ON A DESIGN/BUILD BASIS 4"x4"x3/8" ANGLE FOR SHEAR TRANSFER AND STEEL DECK SUPPORT ANGLE SHALL FOLLOW ROOF SLOPEBOND BEAM HEIGHT VARIES WITH ROOF SLOPE HORIZONTAL REINFORCING EVERY 2'-0" O.C. 2" AIR SPACE 4" CONCRETE FLOOR SLAB SEE SPECS. AND OTHER DETAILS TOP OF MASONRY 16'-0" AFF TOP OF INTERMEDIATE BOND BEAM 10'-0" AFFTO DO A3.5 A3.5 THIS IS TYPICAL ON ENTIRE PERIMETER OF BUILDING MASONRY I I IREVISIONS:DRAWING COMPLETION DATE:4820 Buttonwood CrescentARCHITECT AIAGORDON CLARKIndianapolis, Indiana 46228Phone: 317 255-2546317 252-5573Fax: GClark4820@aol.comCONVENIENCE STORE / FOOD MARTVILLAGE OF WEST CLAYCARMEL, INDIANASOUTHWEST CORNER OFHARLESTON STREET AND TOWNE ROADOCTOBER 14, 2021 FOR PERMITTING AND CONSTRUCTIONSTEEL JOISTS AND GIRDERS PART 1 - GENERAL 1.1 SUMMARY A. THIS SECTION INCLUDES THE FOLLOWING: 1. OPEN-WEB, K-SERIES STEEL JOISTS. 2. JOIST GIRDERS. 1.2 SUBMITTALS A. SHOP DRAWINGS: PROVIDE SHOP DRAWINGS OF ADEQUATE DETAIL FOR ARCHITECT TO REVIEW PROPOSED INSTALLATION. 1.3 QUALITY ASSURANCE A. MANUFACTURER QUALIFICATIONS: A FIRM EXPERIENCED IN MANUFACTURING JOISTS SIMILAR TO THOSE INDICATED FOR THIS PROJECT AND WITH A RECORD OF SUCCESSFUL IN-SERVICE PERFORMANCE. 1. MANUFACTURER MUST BE CERTIFIED BY SJI TO MANUFACTURE JOISTS COMPLYING WITH SJI STANDARD SPECIFICATIONS AND LOAD TABLES. B. WELDING (IF USED): QUALIFY PROCEDURES AND PERSONNEL ACCORDING TO AWS D1.1, "STRUCTURAL WELDING CODE--STEEL," AND AWS D1.3, "STRUCTURAL WELDING CODE--SHEET STEEL." 1.4 DELIVERY, STORAGE, AND HANDLING A. DELIVER, STORE, AND HANDLE JOISTS AS RECOMMENDED IN SJI'S "SPECIFICATIONS." PART 2 - PRODUCTS 2.1 MATERIALS A. STEEL: COMPLY WITH SJI'S "SPECIFICATIONS" FOR CHORD AND WEB MEMBERS. 2.2 PRIMERS A. PRIMER: SSPC-PAINT 15, TYPE I, RED OXIDE; FS TT-P-636, RED OXIDE; OR MANUFACTURER'S STANDARD SHOP PRIMER COMPLYING WITH PERFORMANCE REQUIREMENTS OF EITHER OF THESE RED-OXIDE PRIMERS. 2.3 STEEL JOISTS A. MANUFACTURE STEEL JOISTS ACCORDING TO SJI'S "SPECIFICATIONS," WITH STEEL-ANGLE TOP- AND BOTTOM-CHORD MEMBERS, AND AS FOLLOWS: 1. MANUFACTURE K-SERIES STEEL JOISTS ACCORDING TO "STANDARD SPECIFICATIONS FOR OPEN WEB STEEL JOISTS, K- SERIES," WITH STEEL-ANGLE TOP- AND BOTTOM-CHORD MEMBERS, UNDERSLUNG ENDS, AND PARALLEL TOP CHORD. B. COMPLY WITH AWS REQUIREMENTS AND PROCEDURES FOR SHOP WELDING, APPEARANCE, QUALITY OF WELDS, AND METHODS USED IN CORRECTING WELDING WORK. 2.4 JOIST GIRDERS A. MANUFACTURE JOIST GIRDERS ACCORDING TO "STANDARD SPECIFICATIONS FOR JOIST GIRDERS," IN SJI'S "SPECIFICATIONS," WITH STEEL-ANGLE TOP- AND BOTTOM-CHORD MEMBERS; WITH END AND TOP-CHORD ARRANGEMENTS INDICATED. B. COMPLY WITH AWS REQUIREMENTS AND PROCEDURES FOR SHOP WELDING, APPEARANCE, QUALITY OF WELDS, AND METHODS USED IN CORRECTING WELDING WORK. 2.5 JOIST ACCESSORIES A. BRIDGING: PROVIDE BRIDGING ANCHORS AND NUMBER OF ROWS OF HORIZONTAL OR DIAGONAL BRIDGING OF MATERIAL, SIZE, AND TYPE REQUIRED BY SJI'S "SPECIFICATIONS" FOR TYPE OF JOIST, CHORD SIZE, SPACING, AND SPAN. B. BRIDGING: SCHEMATICALLY INDICATED. DETAIL AND FABRICATE ACCORDING TO SJI'S "SPECIFICATIONS." C. SUPPLY MISCELLANEOUS ACCESSORIES, INCLUDING SPLICE PLATES AND BOLTS REQUIRED BY JOIST MANUFACTURER TO COMPLETE JOIST INSTALLATION. PART 3 - EXECUTION 3.1 INSTALLATION A. DO NOT INSTALL JOISTS UNTIL SUPPORTING CONSTRUCTION IS IN PLACE AND SECURED. B. INSTALL JOISTS AND ACCESSORIES PLUMB, SQUARE, AND TRUE TO LINE; SECURELY FASTEN TO SUPPORTING CONSTRUCTION ACCORDING TO SJI'S "SPECIFICATIONS," JOIST MANUFACTURER'S WRITTEN RECOMMENDATIONS, AND REQUIREMENTS IN THIS SECTION. C. BOLT JOISTS TO SUPPORTING STEEL FRAMEWORK USING CARBON- STEEL BOLTS, UNLESS OTHERWISE INDICATED. END OF SECTION 05210 COLUMN PER PLAN 3/4"x10"x10" @ TS 6x6 BASE PLATE 1 1/2"1 1/2" PLANELEVATION 1 1/2"1 1/2"BOLTS (A36) (4) - 3/4"Ø ANCHOR 2" NON-SHRINKGROUT6" PROJ.COLUMN BASE TYPICAL TUBE SCALE: 1/4" = 1'-0" #5 REBARS 12" O.C.2'-8"1'-0""L" #5'S IN EACH CORNER OF PIER 4" CONCRETE SLAB SEE SPECS. AND DETAILS 6"x6"x3/8" TUBE STEEL COLUMNS (TYPICAL ALL) SCALE: 1/4" = 1'-0" TYPICAL COLUMN FOOTER 4'-0" #5 REBARS 12" O.C. TYPICAL ALL "L" #5'S IN EACH CORNER OF PIER 24" SQUARE PIER 4'-0"4'-0"STEEL FRAMING GENERAL NOTES: MISCELLANEOUS: Any additional work such as canopies, overhangs, sunshades or other architectural features requiring structural decisions and not certified by Gordon Clark must be indicated on shop drawings certified by a professional engineer licensed to practice in the state of Indiana. STRUCTURAL STEEL: Structural steel detailing, fabrication and erection shall conform to the AISC “Specification for the Design, Fabrication, and Erection of Structural Steel for Buildings” latest edition with amendments, and the current AISC “Code of Standard Practice for Steel Buildings”. Structural steel tubes and pipe shapes shall conform to ASTM A500 Grade 46. Structural steel rolled shapes, except plates and angles, shall conform to ASTM A500 Grade 45. Anchor bolts shall conform to ASTM F1554 Grade 36, unless otherwise noted. Erector shall maintain adequate temporary bracing in each direction until diaphragm and lateral brace construction is completed. Unless otherwise noted, bolted connections for structural steel members shall be made with ¾” diameter high strength steel bolts conforming to ASTM A325. Except as noted, bolted connections shall be tightened to the snug tight condition. Bolted connections where used in brace elements shall be tightened using the turn-of-nut condition. Connections shall conform to the “Specification for Structural Joints using ASTM A325 or A490 Bolts”, approved by the Research Council on Structural Connections of the Engineering Foundation. Welding procedures shall conform to the latest edition of the American Welding Society’s “Structural Welding Code for Steel ANSI / AWS D1.1”, Reinforcing Steel ANSI / AWS D1.4, and Steet Steel ANSI / AWS D1.3”. Splicing of structural steel members where not detailed on the Contract Documents is prohibited without the prior approval of the architect as to location, type of splice and connection to be made. Surfaces within 2 inches of any field weld shall be free of materials that would prevent proper welding or produce toxic fumes while welding is being done. Beams shall be cambered upward unless indicated otherwise. Structural steel shall be shop-painted with a rust inhibiting primer. Steel that shall be exposed to the weather shall receive one additional finish coat. Field measure steel prior to fabrication as often as possible. Shop drawings shall be reviewed by the Architect for design concepts expressed in the Contract Documents only. The Contractor shall be responsible for all dimensions, accuracy, and fit of work. DESIGN DATA: The building structural has been designed in accordance with the 2012 Indiana Building Code. Roof Loads: Dead Load: 13 psf Live Load: 20 psf Ground Snow Load (Pg): 20 psf - Flat Roof Snow Load: (Pf): 20 psf - Snow Exposure factor (Ce): 1.0 - Snow Load Importance Factor: (ls): 1.0 - Thermal Factor (Ct): 1.0 Wind Design Data: Basic Wind Speed (3 second gust): 115 mph ULT; 90 mph Nominal Risk Category: II Wind Exposure Category: C Internal Pressure Coefficient: +/- .18 Base Wind Pressure: 18.8 psf Seismic Design Data: Risk Category: II Seismic Site Class: D 0.2 sec. Mapped MCE Ground Motion (Ss): 0.148 1.0 sec. Mapped MCE Ground Motion (S1): 0.082 0.2 sec. 5% Damped Spectral Response Acceleration (Sds): 0.157 1.0 sec. 5% Damped Spectral Response Acceleration (Sd1): 0.131 Seismic Design Category: B Basic structural and seismic resisting system: Ordinary System Not Specifically Detailed for Seismic Resistance. Analysis Procedure: Equivalent lateral force procedure Response Modification Coefficient ®: 3 Seismic response Coefficient (Cs): .052 Slab Capacity: Post Load = 16K (Min. Base = 4” x 3”) Uniform Loading = 1.0 K/sf Back-to-Back Post Load = 12K (Min. Base = 4”x3”) A4.1 I I IREVISIONS:DRAWING COMPLETION DATE:4820 Buttonwood CrescentARCHITECT AIAGORDON CLARKIndianapolis, Indiana 46228Phone: 317 255-2546317 252-5573Fax: GClark4820@aol.comCONVENIENCE STORE / FOOD MARTVILLAGE OF WEST CLAYCARMEL, INDIANASOUTHWEST CORNER OFHARLESTON STREET AND TOWNE ROADOCTOBER 14, 2021 FOR PERMITTING AND CONSTRUCTIONADA TRANSACTION PULL OUT DRAWER WITH MIN. 30" WIDE x 24" DEEP FOOTPRINT DRAWER POS BY OTHERS POS BY OTHERS SECURITY GLASS INSTALLATION BY OTHERS NOT PART OF WORK OF THIS SET OF DOCUMENTS SCALE: 1/2" = 1'-0" ELEVATION OF CASHIER AREA OWNER'S OPTION. VERIFY. 3 COMPARTMENT SINK FRP OR OTHER NON-ABSORBENT SURFACE HAND SINK / 3 COMPARTMENT SINK / AND MOP SINK ELEVATION SCALE: 1/2" = 1'-0" MOP SINK WATER HEATER ABOVE HAND SINK ADA URINAL ADA WC ADA SINK 60" x 60" CLEAR SPACE 30" x 48" CLEAR SPACE 48" x 30" CLEAR SPACE ADA WC ADA SINK 48" x 30" CLEAR SPACE 60" x 60" CLEAR SPACE SCALE: 1/2" = 1'-0" ADA URINAL ADA WC RESTROOM INTERIOR ELEVATIONS SCALE: 1/2" = 1'-0" RESTROOM DETAIL FLOOR PLAN 7'-6"4 3/4"6'-3"4 3/4" COOLER WALLS SEE SPECIFICATIONS 7'-10"3/0 x 7/0 HM FRAME FLUSH WOOD DOOR ACCESSIBILITY REQUIREMENTS: MIRRORS: MIRRORS SHALL BE FLAT AGAINST THE WALL, WITH THE BOTTOM OF THE MIRROR SURFACE NO MORE THAN 40 INCHES ABOVE FINISH FLOOR. THE TOP EDGE OF THE MIRROR SURFACE SHALL BE A MINIMUM OF 74 INCHES ABOVE FINISH FLOOR. LAVATORIES AND SINKS: WATER SUPPLY AND DRAINPIPES UNDER LAVATORIES AND SINKS SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES AND SINKS. ACCESSIBLE TOILET WATER CLOSETS: CENTERLINE OF WATER CLOSET SHALL BE 16” MINIMUM TO 18” MAXIMUM FROM THE SIDEWALL OR PARTITION. CONTRACTOR SHALL CONFIRM IN THE FIELD THAT THE CLEARANCES IN A WATER CLOSET STALL SHALL BE 60 INCHES MINIMUM MEASURED PERPENDICULAR FROM THE SIDEWALL AND REAR WALL. NO OTHER FIXTURES OR OBSTRUCTIONS SHALL BE LOCATED WITHIN THE REQUIRED WATER CLOSET CLEARANCE. NOTIFY ARCHITECT IMMEDIATELY IF AN OBSTRUCTION CONFLICTS WITH THE ABOVE REQUIREMENTS. HEIGHT: THE HEIGHT OF ACCESSIBLE WATER CLOSETS SHALL BE 17 INCHES MINIMUM TO 19 INCHES MAXIMUM MEASURED TO THE TOP OF THE TOILET SEAT. SEATS SHALL NOT BE SPRUNG TO RETURN TO A LIFTED POSITION. FLUSH CONTROLS SHALL BE LOCATED ON THE TRANSFER SIDE OF THE WATER CLOSET. ACCESSIBLE URINALS: URINALS SHALL BE WALL-HUNG TYPE WITH THE RIM 17 INCHES MAXIMUM ABOVE FINISH FLOOR. URINALS SHALL PROVIDE A MINIMUM DEPTH OF 13 1/3 INCHES MEASURED FROM THE OUTER FACE OF THE URINAL RIM TO THE BACK OF THE FIXTURE. CONFIRM THAT THERE IS CLEAR FLOOR SPACE OF 48 INCHES PERPENDICULAR FROM REAR WALL OF URINAL, AND 30 INCHES CENTERED ON ACCESSIBLE URINAL. IF A CONFLICT IS PRESENT, NOTIFY ARCHITECT. GRAB BARS: GRAB BARS SHALL BE INSTALLED STRICTLY ACCORDING TO ARCHITECT’S DRAWING SHOWING ACCESSIBILITY DIMENSIONS OR THE LATEST ADA REQUIREMENTS, WHICHEVER IS STRICTER. WHERE WALL SPACE PERMITS, A 36 LONG GRAB BAR SHALL BE INSTALLED ON THE REAR WALL OF THE WATER CLOSET AREA, WITH THE ADDITIONAL LENGTH ON THE TRANSFER SIDE OF THE WATER CLOSET. GENERAL TOILET ROOM ELEMENTS: IF SOAP AND TOWEL DISPENSERS ARE PROVIDED, THEY MUST BE LOCATED WITHIN THE REACH RANGES IN ADA STANDARDS.TYPICALACCESSIBLE TOILET1'-5"2'-0"3'-0"39" - 41"ACCESSIBLE TOILETTYPICAL1'-6"1'-5"2'-0"3'-0"39" - 41"1'-6"TYPICALSTANDARD TOILET1'-3"2'-0"TYPICALSTANDARD TOILET2'-0"TYPICALACCESSIBLE URINAL1'-6"TYPICALSTANDARD URINAL2'-0"TYPICALACCESSIBLE LAVATORY2'-10" MAX.3'-4" MAX TO BOTTOM OF MIRRORTYPICALSTANDARD LAVATORY2'-10"3'-4" MAX TO BOTTOM OF MIRROR6'-0" MIN. TO TOP OF MIRROR4'-0"FIRE EXTINGUISHERWITH CABINET4'-0"FIRE EXTINGUISHER2'-9"WATER COOLERACCESSIBLE3'-0"WATER COOLER5'-6"COAT HOOKS3'-6"PUSH PLATESHEIGHTCOUNTER3'-0"PAPER TOWEL DISPENSER1'-0"6'-8"80" AFF TO CENTERLINEHORN AND/OR STROBE4'-0"WALL SWITCHESINSTALL ALL REQUIRED BLOCKING IN WALL FOR GRAB BARS, MIRRORS, AND ACCESSORIES 9 FT 8 FT 7 FT 6 FT 5 FT 4 FT 3 FT 2 FT 1 FT FLOOR LINE 5'-0" REQUIRED CLEAR SPACE WITH NO ENCROACHMENT 1'-6" 5'-0" REQUIRED CLEAR SPACE WITH NO ENCROACHMENT 1'-6"1'-3" MIN. 1'-3" MIN. 1'-3" MIN. 30" x 48" CLEAR FLOOR SPACE IN FRONT OF LAV 39" - 41" 4'-6" 1'-0"3'-6" 8" 6"3'-0"BOTTOM OF MIRROR TO DO A4.2 A4.2 A4.2 A4.2A4.2 1 2 3 4 ADA WC 60" MIN24"MIN30" MIM36" MIN48" MAXFOR ACCESSIBLE USE3'-0"48"18" MIN11"56" MIN WALL HUNG59" MIN FLOOR MOUNT3'-2"PUSH PLATES,HANDLES& PUSH BARS48"VIEWERS/SIGNAGE4'-0"17'-19"DEAD BOLTS5'-0"19" MIN3'-4" MAX3'-3 1/2" MAX2'-7"2'-3"9"33"-36"39"-41"33"-36"1 1/2"CLR17" MIN19" MIN3'-2 5/8"60" MIN4'-0" MAXMAXIMUM SIDE REACH1'-5"42" MIN*54" MIN4'-0"42" MIN**AT TOP OF CABINET1/4"3'-6"48" MIN48" MIN *48" MAX9" MIN.60" MIN27" MIN.34" MAX.29" MIN.40" MAX.TO BOTTOM OF5'60" MIN48" MINREFLECTING SURFACE60" MINX > 842" MIN5'-0"48"48" MIN2'-6"X > 84'-0"60" MIN48" MIN2'-4"2'-6"4'-0"15" MIN60" MIN7'-0"4'-0" MAXMAXIMUM SIDE REACH1/4" MAX.5'-0"3'-8" AT ADA STALL9"48" MAX4'-6" MIN. 4'-0" 10" 39"-41" 1'-0"3'-6" MIN. CL 6" 1'-0" MIN. 3'-0" MIRROR 2'-6"MAX. 17"-19" 7" 4'-0"4'-0" WC 1'-6" WC URINAL FEC FE 8"MIN. KNEE CLEARANCE 6"MAX 17" MIN.TOE CLEARANCE A. FORWARD REACH TO WALL MOUNTED OBJECTS CL 1'-6"1'-6"9" ACCESSIBLE SIGNAGE FOR RESTROOMS OR TACTILE EXIT SIGN AT EXIT LOCATIONS 8" MAX L CL MIRROR CL B.O. FRAME CL CL CL A. FORWARD REACH TO WALL MOUNTED OBJECTS 4'-0" BABY CHANGING TABLE Fixture and Accessory Mounting Heights NTS (A-G) MANEUVERING CLEARANCE AT MANUAL SWINGING DOORS 48" MIN 16"-18"16"-18" (A) FRONT APPROACH PULL SIDE 18" MIN (B) FRONT APPROACH PUSH SIDE 12" MIN* * IF BOTH CLOSER AND LATCH AR PROVIDED (C) HINGE APPROACH PULL SIDE (1-2) MANEUVERING CLEARANCE AT DOORWAYS WITHOUT DOORS (1) FRONT APPROACH (2) SIDE APPROACH COMPRESSED CARPET 1/4" MAX. BELOW THRESHOLD 36" MIN 1/2" MAX. PILE HEIGHT TRANSITION BETWEEN FLOOR FINISHES 60" MIN CLEAR FLOOR SPACE 60" MIN. CLEAR FLOOR SPACE 60" MIN 12" 42" MIN 60" MIN 17" MIN. CLEAR FLOOR SPACES (X-Z) TWO DOORS IN A SERIES (G) LATCH APPROACH PUSH SIDE 19" MAX. NOTE: 12" MIN 36" MIN 12" MIN PROVIDE PRIVACY DOOR LOCK WHEN IT IS A PRIVATE TOILET OR FOR UNISEX USE. 24" MIN *48" MIN IF CLOSER IS PROVIDED (X) 60" MIN (Y) DOOR WIDTH 48" MIN DOOR WIDTH (Z) 48" MIN DOOR WIDTH NOTES: 1. 1/2" MAXIMUM TOTAL HEIGHT WITH 1/4" MAXIMUM VERTICAL CHANGE AT EDGE. 2. 1:2 SLOPED BEVEL REQUIRED IF LEVEL CHANGE IS OVER 1/4" VERTICAL LEVEL CHANGE. 3. 1/4" MAXIMUM VERTICAL LEVEL CHANGE. LEVEL CHANGES MIN* 22" MIN (D) HINGE APPROACH PULL SIDE (E) HINGE APPROACH PUSH SIDE * IF BOTH CLOSER AND LATCH ARE PROVIDED ** 48" MIN IF BOTH CLOSER AND LATCH PROVIDED (F) LATCH APPROACH PULL SIDE (a) PULL SIDE * 54" MIN IF CLOSER IS PROVIDED 24" MIN 18" MIN (b) PUSH SIDE (c) PUSH SIDE, DOOR PROVIDED WITH BOTH CLOSER AND LATCH 1/2" 12" MIN THRESHOLD 1/4" MAX. MAX. THRESHOLD FIN. FLOOR LEVEL Clear Floor Space NTS Maneuvering Clearances at Doors NTS Threshold Details NTS 36"36" DETAIL 1/4"3/4" TYPICAL DETECTABLE WARNING TILES @ CURB RAMPS - SEE TYPICAL ACCESSIBILITY NOTES SHEET FOR MORE INFO. GROOVED WARNING BORDER DEPRESS CURB 1", AS REQ. 36" LINE OF CURB AS OCCURS LINE OF FRONT OF REQ'D PARKING SPACE. 1:10 MAX. SLOPE (TYPICAL) CURB RAMP DETAILS Exterior Ramp Details NTS LINE OF OBSTRUCTION OR EDGE OF WALK AREA AS OCCURS, TYP. 36" 60" 1:12 SLOPE MAX. TYP. 4. EXPOSED HOT WATER PIPE AND DRAIN PIPE ON LAVATORY SHALL BE INSULATED OR OTHERWISE SURFACES UNDER THE LAVATORY. 5. FAUCETS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST . LEVER-OPERATED, PUSH TYPE AND ELECTRONICALLY CONTROLLED ARE ACCEPTABLE. SELF CLOSING VALVES SHALL REMAIN OPEN 10 SEC. MIN. 6. G.C. IS TO PROVIDE WOOD BLOCKING IN WALL AT MOUNTING POINTS OF ACCESSORIES TYPICAL. 7. ACCESSIBLE RESTROOM SIGNAGE AND SIGNS ON DOORS PROVIDED BY GC. General Notes NTS 1. ALL SIGNAGE AND PICTOGRAMS SHALL COMPLY WITH CHAPTER 7 OF ANSI A117.1-2009. 2. ALL DOORS SHALL COMPLY WITH SECTION 404 OF ANSI A117.1-2009. 3. FLUSH CONTROL SHALL BE MOUNTED NO HIGHER THEN 44" A.F.F. AND SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. I I IREVISIONS:DRAWING COMPLETION DATE:4820 Buttonwood CrescentARCHITECT AIAGORDON CLARKIndianapolis, Indiana 46228Phone: 317 255-2546317 252-5573Fax: GClark4820@aol.comCONVENIENCE STORE / FOOD MARTVILLAGE OF WEST CLAYCARMEL, INDIANASOUTHWEST CORNER OFHARLESTON STREET AND TOWNE ROADOCTOBER 14, 2021 FOR PERMITTING AND CONSTRUCTIONA4.3 I I IREVISIONS:DRAWING COMPLETION DATE:4820 Buttonwood CrescentARCHITECT AIAGORDON CLARKIndianapolis, Indiana 46228Phone: 317 255-2546317 252-5573Fax: GClark4820@aol.comCONVENIENCE STORE / FOOD MARTVILLAGE OF WEST CLAYCARMEL, INDIANASOUTHWEST CORNER OFHARLESTON STREET AND TOWNE ROADOCTOBER 14, 2021 FOR PERMITTING AND CONSTRUCTIONA. Deliver materials to the project site clearly marked for proper identification. B. Receive, handle and store materials in conformance with the manufacturers printed instructions. 1. 2. as beams or trusses. Position bundles of tubing parallel to the slope of the roof and block prior to opening to prevent the tubing from rolling down the roof slope when unbundled. PART 2 - PRODUCTS 2.1 PERFORMANCE REQUIREMENTS A. Design Loads: Comply with Building Code for site location and building height. 1. 2. Design to resist ASCE 7 - Minimum Design Loads for Buildings and Other Structures, using the latest published ASCE version. Design all materials, assembly and attachments to resist snow, wind, suction and uplift loading at any point without damage or permanent set. B. Structural Design: Prepare structural design calculations for screen framing and attachment to structure including reactions at base supports for verification of roof structure by Architect. C. All welds to be performed by an AWS certified welder. Valid certification to be provided. 2.2 MANUFACTURERS A. Proposed Manufacturer: RoofScreen Mfg., which is located at: 347 Coral St.; Santa Cruz, CA 95060; Toll Free Tel: 866-766- 3727; Tel: 831-421-9230; Fax: 866-253-0738; Email: request info (info@roofscreen.com); Web: www.roofscreen.com. 2.3 FABRICATION A. Fit and shop assemble items in largest practical sections, for delivery to site. B. Fabricate items with joints tightly fitted and secured. C. Supply components required for anchorage of fabrications. Fabricate anchors and related components of same material and finish as fabrication, except where specifically noted otherwise. D. Fabricate system components so that portions of screen can be dismantled for repairs to equipment being screened and for future roof replacement. E. Trim and Closures: Fabricated from 24 gauge metal and finished with the manufacturer’s standard coating system. PART 3 - EXECUTION 3.1 EXAMINATION A. If preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding. B. Do not begin installation until conditions have been properly prepared. 3.2 INSTALLATION A. B. Install in accordance with manufacturer's instructions. Install components plumb and level, accurately fitted, free from distortion or defects. C. Anchor fabrications to structure as indicated. D. Separate dissimilar metals and use gasketed fasteners, isolation shim, or isolation tape to eliminate possibility of corrosive or electrolytic action between metals. E. Exercise care when installing components so as not to damage finish surfaces. Touch up as required to repair damaged finishes. F.Install flashing boots at base supports as required to provide a watertight connection. Install as recommended by the roof membrane manufacturer. G. Remove all protective masking from material immediately after installation. 3.3 CLEANING AND PROTECTION A. Replace metal wall panels and framing members that have been damaged or have deteriorated beyond successful repair by finish touchup or similar minor repair procedures. A. Stand-alone roof equipment screens and supporting steel framework. Screens shall be designed to attach to the roof structure and not the equipment being screened. B. Roof screen accessories. 1.2 RELATED SECTIONS A. Roof Top HVAC Equipment. 1.3 COORDINATION A. Coordinate Work with other operations and installation of roofing materials to avoid damage to installed insulation and membrane materials. 1.4 ACTION SUBMITTALS A. Product Data: Manufacturer's data sheets on each product to be used, including: 1. 2. 3. Preparation instructions and recommendations. Storage and handling requirements and recommendations. Installation methods. B. Shop Drawings: Layout and erection drawings showing typical cross sections and dimensioned locations of all frames and base supports. Include erection drawings, elevations, and details where applicable. Indicate welded connections using standard AWS A2.4 welding symbols. Indicate net weld lengths. 1.5 INFORMATIONAL SUBMITTALS A. Design Calculations: 3 copies of structural design calculations for structural components and components resisting wind loads with seal and signature of professional engineer licensed in the State of Indiana B. Manufacturer's Certificates: Certify products meet or exceed specified requirements. C. Warranties: 3 signed copies. 1.6 DELIVERY, STORAGE, AND HANDLING ROOF SCREENS: A4.4 ELECTRICAL SYSTEM GROUNDING REQUIREMENTS: STRICTLY FOLLOW NEC 250.50 AND 250.52. INSTALL GROUNDING ELECTRODE ACCORDING TO THE FOLLOWING LIST: WATER PIPE IF 10 FEET OR MORE OF METAL WATER PIPE IS IN CONTACT WITH THE EARTH. METAL FRAME OF THE BUILDING OR STRUCTURE WHERE ANY OF THE FOLLOWING FOUR METHODS ARE USED TO MAKE AN EARTH CONNECTION: 1. CONCRETE-ENCASED ELECTRODE IN AT LEAST 2 INCHES OF CONCRETE LOCATED WITHIN OR NEAR THE BOTTOM OF A CONCRETE FOUNDATION OR FOOTING THAT IS IN INDIRECT CONTACT WITH THE EARTH. 2. GOUND RING ENCIRCLING THE BUILDING OR STRUCTURE IN DIRECT CONTACT WITH THE EARTH. 3. ROD OR PIPE ELECTRODE NOT LESS THAN 8 FEET IN LENGTH. 4. OTHER LOCAL UNDERGROUND SYSTEMS SUCH AS PIPING, UNDERGROUND TANKS AND UNDERGROUND WELL CASING. COMMUNICATIONS EQUIPMENT: COMMUNICATIONS EQUIPMENT SHALL BE GROUNDED TO BUILDING GROUNDING ELECTRODE SIMILAR TO OTHER ELECTRICAL EQUIPMENT. FOLLOW NEC 800.100 (B). ALL GROUNDING ELECTRODES THAT ARE PRESENT AT THIS BUILDING STRUCTURE SHALL BE BONDED TOGETHER TO FORM THE GROUNDING ELECTRODE SYSTEMS. BOND ALL GROUNDING ELECTRODES THAT ARE PRESENT AT THIS BUILDING STRUCTURE TOGETHER TO FORM THE GROUNDING ELECTRODE SYSTEM. GROUNDING ELECTRODES THAT MAY BE PRESENT AT THIS BUILDING INCLUDE GROUNDING ELECTRODE RODS, CONCRETE ENCASED ELECTRODES SUCH AS BUILDING FOUNDATION REBAR, UNDERGROUND METAL WATER PIPES, AND METAL FRAME OF THE BUILDING INCLUDING STRUCTURAL STEEL COLUMNS. SEE GROUNDING DETAIL THAT IS A PART OF DRAWINGS OF THIS SET. NOT PERMITTED: METAL UNDERGROUND GAS PIPING. ALUMINUM ELECTRODES MASONRY SPECIFICATION AND REQUIREMENTS: UNIT MASONRY SPECIFICATIONS AND REQUIREMENTS: SECTION 04810 - UNIT MASONRY ASSEMBLIES o THIS SECTION INCLUDES UNIT MASONRY ASSEMBLIES CONSISTING OF THE FOLLOWING: CONCRETE MASONRY UNITS. MORTAR AND GROUT. REINFORCING STEEL. MASONRY JOINT REINFORCEMENT. TIES AND ANCHORS. EMBEDDED FLASHING. MISCELLANEOUS MASONRY ACCESSORIES. QUALITY ASSURANCE: o COMPLY WITH “SPECIFICATIONS FOR MASONRY CONSTRUCTION” ACI 530.1/ASCE 6.88, MOST CURRENT EDITION. CONCRETE MASONRY UNITS (CMU’S) FOR ALL FINISHING SHALL CONFORM TO ASTM C90. DELIVERY, STORAGE, AND HANDLING o STORE MASONRY UNITS AND RELATED PRODUCTS ON ELEVATED PLATFORMS IN A DRY LOCATION. IF UNITS ARE NOT STORED IN AN ENCLOSED LOCATION, COVER TOPS AND SIDES OF STACKS WITH WATERPROOF SHEETING, SECURELY TIED. IF UNITS BECOME WET, DO NOT INSTALL UNTIL THEY ARE DRY. PROJECT CONDITIONS o PROTECTION OF MASONRY: DURING CONSTRUCTION, COVER TOPS OF WALLS, PROJECTIONS, AND SILLS WITH WATERPROOF SHEETING AT END OF EACH DAY'S WORK. COVER PARTIALLY COMPLETED MASONRY WHEN CONSTRUCTION IS NOT IN PROGRESS. o STAIN PREVENTION: PREVENT GROUT, MORTAR, AND SOIL FROM STAINING THE FACE OF MASONRY TO BE LEFT EXPOSED OR PAINTED. IMMEDIATELY REMOVE GROUT, MORTAR, AND SOIL THAT COME IN CONTACT WITH SUCH MASONRY. o COLD-WEATHER REQUIREMENTS: DO NOT USE FROZEN MATERIALS OR MATERIALS MIXED OR COATED WITH ICE OR FROST. DO NOT BUILD ON FROZEN SUBSTRATES. REMOVE AND REPLACE UNIT MASONRY DAMAGED BY FROST OR BY FREEZING CONDITIONS. COMPLY WITH COLD-WEATHER CONSTRUCTION REQUIREMENTS CONTAINED IN SECTION 2104.3 OF THE UNIFORM BUILDING CODE. o HOT-WEATHER REQUIREMENTS: PROTECT UNIT MASONRY WORK WHEN TEMPERATURE AND HUMIDITY CONDITIONS PRODUCE EXCESSIVE EVAPORATION OF WATER FROM MORTAR AND GROUT. PROVIDE ARTIFICIAL SHADE AND WIND BREAKS AND USE COOLED MATERIALS AS REQUIRED. PRODUCTS CONCRETE MASONRY UNITS o GENERAL: PROVIDE SHAPES INDICATED AND AS FOLLOWS: PROVIDE SPECIAL SHAPES FOR LINTELS, CORNERS, JAMBS, SASH, CONTROL JOINTS, HEADERS, BONDING, AND OTHER SPECIAL CONDITIONS. PROVIDE CORNER UNITS FOR OUTSIDE CORNERS, UNLESS OTHERWISE INDICATED. o CONCRETE MASONRY UNITS: UBC STANDARD 21-4 AND AS FOLLOWS: EXPOSED FACES: MANUFACTURER'S STANDARD COLOR SMOOTH FACE UNITS NOT CHIPPED OR DAMAGED. REINFORCING STEEL o UNCOATED STEEL REINFORCING BARS: ASTM A 615/A 615M; ASTM A 616/A 616M, INCLUDING SUPPLEMENT 1; OR ASTM A 617/A 617M, GRADE 60. MASONRY JOINT REINFORCEMENT o GENERAL: UBC STANDARD 21-10 AND AS FOLLOWS: PROVIDE IN LENGTHS OF NOT LESS THAN 10 FEET, WITH PREFABRICATED CORNER AND TEE UNITS WHERE INDICATED. TIES AND ANCHORS, GENERAL o GENERAL: FOLLOW BEST MASONRY PRACTICES. CONSULT WITH ARCHITECT IF NEEDED. EMBEDDED FLASHING MATERIALS METAL FLASHING: FOLLOW BEST MASONRY PRACTICES FOR BOTH EXPOSED AND CONCEALED FLASHING. SUBPARAGRAPH BELOW IS AN EXAMPLE ONLY; REVISE IF OTHER LAMINATED PRODUCTS ARE REQUIRED. EXAMINATION o BEFORE INSTALLATION, EXAMINE ROUGH-IN AND BUILT-IN CONSTRUCTION TO VERIFY ACTUAL LOCATIONS OF PIPING CONNECTIONS. INSTALLATION, GENERAL DRAW BLOCKS FROM MORE THAN ONE PALLET AT A TIME DURING CONSTRUCTION. ALL EXTERIOR MORTAR SHALL INCLUDE W.R. GRACE DRY-BLOCK WATER-REPELLANT ADDITIVE ADDED TO EACH BATCH IN THE APPROPRIATE DOSAGE RATES FOR MORTAR BEING USED. USE ADDITIVE STRICTLY IN CONFORMANCE WITH MANUFACTURER’S WRITTEN INSTRUCTIONS. LAY UNITS USING BEST MASONRY PRACTICES. LAY ALL BLOCK LEVEL. PLUMB, AND TRUE. USE ONLY QUALITY UNITS, WITH NO DAMAGE. UNITS SHALL HAVE UNIFORM, 3/8” JOINTS BOTH HORIZONTALLY AND VERTICALLY ON THE FINISHED SIDE OF THE WALL. TOOL JOINTS NEATLY AFTER THEY ARE FINGER-HARD TO MAK THEM STRAIGHT AND UNIFORM. SIZE AND PLACE CUT PIECES APPROXIMATELY TO MAINTAIN CONSISTENCY AND BOND. COMPLETE MASONRY CONSTRUCTION USING PROCEDURES AND WORKMANSHIP CONSISTENT WITH THE BEST MASONRY PRACTICES. CONSTRUCTION TOLERANCES o COMPLY WITH TOLERANCES IN ACI 530.1/ASCE 6/TMS 602 CONTROL AND EXPANSION JOINTS o GENERAL: INSTALL CONTROL AND EXPANSION JOINTS IN UNIT MASONRY WHERE INDICATED.OR WHERE REQUIRED BY BEST MASONRY STANDARDS. BUILD-IN RELATED ITEMS AS MASONRY PROGRESSES. DO NOT FORM A CONTINUOUS SPAN THROUGH MOVEMENT JOINTS UNLESS PROVISIONS ARE MADE TO PREVENT IN-PLANE RESTRAINT OF WALL OR PARTITION MOVEMENT. REPAIRING, POINTING, AND CLEANING o NO CHIPPED, BROKEN, OR DEFORMED CONCRETE BLOCK SHALL BE ACCEPTED IN EXPOSED BLOCK AREAS. CONTRACTOR SHALL REPLACE BLOCK, WHICH DOES NOT MEET THESE SPECIFICATIONS, AT CONTRACTOR’S o COMPLETED WALLS WITH A DETERGENT MASONRY CLEANER STRICTLY FOLLOWING MANUFACTURER’S WRITTEN INSTRUCTIONS, INCLUDING THOROUGH RINSING. DO NOT USE ACIDS OR ABRASIVES ON FINISHED SURFACES. FOR STUBBORN MASONRY STAINS OR SMEARS, A 3:1 SOLUTION OF SURE KLEAN BURNISHED CUSTOM MASONRY CLEANER BY PROSOCO MAY BE USED AS LONG AS WALLS RE THOROUGHLY WETTED BEFORE APPLYING THE CLEANING SOLUTION AND THROUGHLY RINSED WITH CLEAN WATER IMMEDIATELY AFTER WASHING. FAILURE TO FOLLOW MANUFACTURER’S INSTRUCTIONS CAN RESULT IN PERMANENT DAMAGE TO THE FINISHED FACES AND CAN RESULT IN CONTRACTOR-REPLACEMENT. DO NOT POWER WASH. O PROTECTION DURING CONSTRUCTION: COVER WALLS EACH DAY AFTER INSTALLATION TO KEEP OPEN WALLS PROTECTED AND DRY. AFTER UNITS ARE INSTALLED THEY SHOULD BE PROTECTED FROM DAMAGE BY OTHER TRADES PREFORMING OPERATIONS THAT CAN STAIN OR OTHERWISE DAMAGE THE FINISHED SURFACES. EXAMINATION o BEFORE INSTALLATION, EXAMINE ROUGH-IN AND BUILT-IN CONSTRUCTION TO VERIFY ACTUAL LOCATIONS OF PIPING CONNECTIONS. INSTALLATION, GENERAL DRAW BLOCKS FROM MORE THAN ONE PALLET AT A TIME DURING CONSTRUCTION. ALL EXTERIOR MORTAR SHALL INCLUDE W.R. GRACE DRY-BLOCK WATER-REPELLANT ADDITIVE ADDED TO EACH BATCH IN THE APPROPRIATE DOSAGE RATES FOR MORTAR BEING USED. USE ADDITIVE STRICTLY IN CONFORMANCE WITH MANUFACTURER’S WRITTEN INSTRUCTIONS. LAY UNITS USING BEST MASONRY PRACTICES. LAY ALL BLOCK LEVEL. PLUMB, AND TRUE. USE ONLY QUALITY UNITS, WITH NO DAMAGE. UNITS SHALL HAVE UNIFORM, 3/8” JOINTS BOTH HORIZONTALLY AND VERTICALLY ON THE FINISHED SIDE OF THE WALL. TOOL JOINTS NEATLY AFTER THEY ARE FINGER-HARD TO MAK THEM STRAIGHT AND UNIFORM. SIZE AND PLACE CUT PIECES APPROXIMATELY TO MAINTAIN CONSISTENCY AND BOND. COMPLETE MASONRY CONSTRUCTION USING PROCEDURES AND WORKMANSHIP CONSISTENT WITH THE BEST MASONRY PRACTICES. CONSTRUCTION TOLERANCES o COMPLY WITH TOLERANCES IN ACI 530.1/ASCE 6/TMS 602 CONTROL AND EXPANSION JOINTS o GENERAL: INSTALL CONTROL AND EXPANSION JOINTS IN UNIT MASONRY WHERE INDICATED.OR WHERE REQUIRED BY BEST MASONRY STANDARDS. BUILD-IN RELATED ITEMS AS MASONRY PROGRESSES. DO NOT FORM A CONTINUOUS SPAN THROUGH MOVEMENT JOINTS UNLESS PROVISIONS ARE MADE TO PREVENT IN-PLANE RESTRAINT OF WALL OR PARTITION MOVEMENT. REPAIRING, POINTING, AND CLEANING o NO CHIPPED, BROKEN, OR DEFORMED CONCRETE BLOCK SHALL BE ACCEPTED IN EXPOSED BLOCK AREAS. CONTRACTOR SHALL REPLACE BLOCK, WHICH DOES NOT MEET THESE SPECIFICATIONS, AT CONTRACTOR’S o COMPLETED WALLS WITH A DETERGENT MASONRY CLEANER STRICTLY FOLLOWING MANUFACTURER’S WRITTEN INSTRUCTIONS, INCLUDING THOROUGH RINSING. DO NOT USE ACIDS OR ABRASIVES ON FINISHED SURFACES. FOR STUBBORN MASONRY STAINS OR SMEARS, A 3:1 SOLUTION OF SURE KLEAN BURNISHED CUSTOM MASONRY CLEANER BY PROSOCO MAY BE USED AS LONG AS WALLS RE THOROUGHLY WETTED BEFORE APPLYING THE CLEANING SOLUTION AND THROUGHLY RINSED WITH CLEAN WATER IMMEDIATELY AFTER WASHING. FAILURE TO FOLLOW MANUFACTURER’S INSTRUCTIONS CAN RESULT IN PERMANENT DAMAGE TO THE FINISHED FACES AND CAN RESULT IN CONTRACTOR-REPLACEMENT. DO NOT POWER WASH. O PROTECTION DURING CONSTRUCTION: COVER WALLS EACH DAY AFTER INSTALLATION TO KEEP OPEN WALLS PROTECTED AND DRY. AFTER UNITS ARE INSTALLED THEY SHOULD BE PROTECTED FROM DAMAGE BY OTHER TRADES PREFORMING OPERATIONS THAT CAN STAIN OR OTHERWISE DAMAGE THE FINISHED SURFACES. I I IREVISIONS:DRAWING COMPLETION DATE:4820 Buttonwood CrescentARCHITECT AIAGORDON CLARKIndianapolis, Indiana 46228Phone: 317 255-2546317 252-5573Fax: GClark4820@aol.comCONVENIENCE STORE / FOOD MARTVILLAGE OF WEST CLAYCARMEL, INDIANASOUTHWEST CORNER OFHARLESTON STREET AND TOWNE ROADOCTOBER 14, 2021 FOR PERMITTING AND CONSTRUCTIONMAIN SERVICE GROUNDING MAIN BONDING JUMPER #2/0 BARE COPPER CONDUCION PER NEC 250.28 CADWELD 4 BARE COPPER GROUNDING ELECTRODE CONDUCTOR (NEC 250.66) MINIMUM OF 20'-0" OF 1/2" REGAR NEC 250.52(A)(3) IN BUILDING WALL FOOTING. BONDING JUMPER TO ENCLOSURE. SIZE PER NEC 250.102(C) COMMUNICATIONS EQUIPMENT BONDED TO ELECTRICAL SYSTEM ELECTRODE PER 800.100 (B). 3/4" DIAMETER x 10 FEET LONG COPPERCLAD GROUND RODS, MINIMUM 20 FEET APART. NEW 250.52 GROUNDING BUS ONE #6 TO PHONE BOARD PER NEC 800.40(D) BUILDING STRUCTURAL STEEL, NEC 250.52(A)(2) CADWELD VALVE, METER, OR UNION COLD WATER SERVICE ENTRANCE (PROVIDE SIMILAR CONNECTION TO FIRE PROTECTION WATER SERVICE ENTRANCE) NEC 250.53(D) SUPPLY SIDE PIPE CLAMP (TYPICAL) JUMPER GROUNDING NOTES: ALL GROUNDING SHALL BE INSTALLED IN ACCORDANCE WITH ARTICLE 250.50 OF THE NATIONAL ELECTRIC CODE. ALL GROUNDING CABLES SHALL BE 4AWG COPPER OR LARGER UNLESS NOTED OTHERWISE. COMMUNICATIONS GROUNDING SHALL BE IN ACCORDANCE WITH ARTICLE 800.100 (B)CADWELDA4.5 CONCRETE REQUIREMENTS AND SPECIFICATIONS: IT IS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO FOLLOW ALL APPLICABLE SAFETY CODES AND REGULATIONS DURING ALL PHASES OF CONSTRUCTION. SHOULD ANY OF THE DETAILED INSTRUCTIONS SHOWN ON THE PLANS CONFLICT WITH THESE STRUCTURAL NOTES, THE SPECIFICATIONS, OR WITH EACH OTHER, THE STRICTEST PROVISIONS SHALL GOVERN. GOVERNING CODES: INTERNATIONAL BUILDING CODE, 2008, WITH CURRENT INDIANA AMENDMENTS. FOUNDATIONS: NOTIFY THE ARCHITECT AS SOON AS POSSIBLE OF ANY UNUSUAL SOIL CONDITIONS, SUCH AS UNEXPECTED SPRING OR SEEPAGE WATER, OR SOIL OF QUESTIONABLE BEARING CAPACITY. ALL FOOTINGS SHALL BEAR ON FIRM UNDISTURBED SOIL OR ENGINEERED FILL WITH AN ALLOWABLE BEARING CAPACITY OF 2,000 POUNDS PER SQUARE FOOT. PERIMETER FOOTINGS SHALL BEAR A MINIMUM OF 3'-0" BELOW EXTERIOR GRADE. STEP FOOTINGS AS REQUIRED. WHERE UNDERGROUND UTILITIES ENTER OR EXIT THE BUILDING, STEP TOPS OF ALL FOOTINGS BELOW UTILITY INVERT ELEVATIONS. DESIGN NET SOIL PRESSURES SPREAD FOOTINGS: CONTINUOUS FOOTERS 2,000 PSI 1,500 PSI. BACKFILL AND FILL MATERIALS: PROVIDE SATISFACTORY SOIL MATERIALS FOR BACKFILL AND FILL, FREE OF CLAY, DEBRIS, WASTE, FROZEN MATERIALS, VEGETABLE AND OTHER DELETERIOUS MATTER. REINFORCED CONCRETE: ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH ACI 318-95, "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE". SPECIFICATIONS: IN GENERAL, COMPLY WITH ACI 301-96, "STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE". PLACEMENT AND CURING OF CONCRETE SHALL CONFORM TO ACI 305 "HOT WEATHER CONCRETING" AND ACI 306 "COLD WEATHER CONCRETING". ALL REINFORCING DETAILS SHALL CONFORM TO ACI 315-86, "MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES" UNLESS DETAILED OTHERWISE ON THE STRUCTURAL DRAWINGS. ALL DEFORMED REINFORCING BARS: ASTM A615, GRADE 60 ALL WELDED WIRE FABRIC:ASTM A185, DELIVERED IN FLAT SHEETS REINFORCING SUPPLIER SHALL PROVIDE ALL BAR ACCESSORIES, CHAIRS, AND SUPPORTS NECESSARY TO SECURE STEEL IN ACCORDANCE WITH "ACT CODE OF STANDARD PRACTICE". WHERE ANY STEPS IN FALL FOOTING ELEVATIONS OCCUR, PROVIDE MAXIMUM STEP OF ONE VERTICAL TO TWO HORIZONTAL. CONCRETE COVER: UNLESS OTHERWISE NOTED, DETAIL REINFORCING TO PROVIDE MINIMUM COVER AS FOLLOWS: CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH:3 INCHES CONCRETE EXPOSED TO EARTH OR WEATHER, #5 RE-BARS OR SMALLER: 1/2 INCHES ALL OTHER:2 INCHES 1 CONCRETE CONTRACTOR SHALL VERIFY SOIL BEARING PRIOR TO CONCRETE PLACEMENT. REPORT DEVIATIONS TO GENERAL CONTRACTOR AND ARCHITECT. CONCRETE IN THE FOLLOWING AREAS SHALL CONSIST OF NATURAL SAND FINE AGGREGATE AND NORMAL WEIGHT COARSE AGGREGATES CONFORMING TO ASTM C33, TYPE 1 PORTLAND CEMENT CONFORMING TO ASTM C150, AND SHALL HAVE THE FOLLOWING COMPRESSIVE STRENGTH AT 28 DAYS: FOOTINGS AND PADS: SLABS-ON-GRADE AND PIERS: 3,000 PSI 4,000 PSI RETAINING WALLS, CURBS, SIDEWALKS, AND SLABS EXPOSED TO DE- ICERS. 4,000 PSI (6% + 1% ENTRAINED AIR BY VOLUME) NO PART OF THE STRUCTURE SHALL BE PLACED ON FROZEN OR WET SOIL. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING THE FOUNDATION AND SOIL WITHIN THE BUILDING AREA FROM FREEZING DURING WINTER CONSTRUCTION. FOOTINGS AND PIERS: DOWELS IN FOOTINGS SHALL MATCH VERTICAL PIER REINFORCING. PROVIDE CORNER BARS AT FOOTING CORNERS TO MATCH HORIZONTAL REINFORCING. MINIMUM LENGTHS OF EACH LEG TO BE 45 BAR DIAMETERS. BACKFILL AGAINST BOTH SIDES OF WALLS EQUALLY UNTIL THE LOWER ELEVATION IS ATTAINED. BRACE ALL FOUNDATION WALLS BEFORE BACKFILLING AND COMPACTING. PROVIDE LEAN CONCRETE (CLASS IV) UNDER FOUNDATIONS FOR ACCIDENTAL OVER-EXCAVATION, SOFT SPOTS, AND TRENCHES. BUILT-IN WORK: INSTALL ALL ANCHORS, INSERTS, NOSINGS, REGLETS AND LIKE ITEMS FURNISHED BY OTHER TRADES FOR INSTALLATION IN CONCRETE WORK. ALL BUILT-IN ITEMS SHALL BE IN PROPER LOCATION AND SHALL BE SO MAINTAINED DURING THE PERFORMANCE OF CONCRETE WORK. SLEEVES, CONDUITS, PIPES AND LIKE ITEMS PASSING THROUGH FLOORS, WALLS, OR BEAMS SHALL BE OF SUCH SIZE OR IN SUCH LOCATION AS NOT TO IMPAIR UNDULY THE STRENGTH OF THE CONSTRUCTION. VAPOR BARRIER PLACEMENT: USE A CONCRETE MIXTURE WITH AN ADEQUATE CEMENT FACTOR - MINIMUM OF 5 1/2 BAGS PER CUBIC YARD. USE A SMALL AMOUNT OF AIR-ENTRAINMENT IN THE MIXTURE TO REDUCE BLEEDING - ABOUT 3% TO 5% AIR. EXTERIOR CONCRETE SHALL HAVE 5 1/2% AIR. PLACE CONCRETE AT LOWEST PRACTICAL SLUMP. A WATER-REDUCING ADMIXTURE MAY BE USED TO LOWER THE MIX WATER CONTENT, IF USED STRICTLY ACCORDING TO WRITTEN MANUFACTURER'S INSTRUCTIONS. PERIMETER INSULATION: A TOTAL OF FOUR FEET WIDTH OF PERIMETER INSULATION SHALL BE PUT IN PLACE. THIS CAN BE A COMBINATION OF HORIZONTAL AND VERTICAL RIGID INSULATION, AS SHOWN ON DRAWINGS. PRE-ENGINEERED METAL CANOPY PART 1 - GENERAL THIS SPECIFICATION INCLUDES Freestanding, pre-engineered metal canopy including concrete foundation, steel framing, metal roof, roof drains and leaders, fascia components, and metal ceiling and accessories. REFERENCES American Institute of Steel Construction, Inc. (AISC): AISC 360 - Specification for Structural Steel Buildings (copyrighted by AISC, ANSI approved American Welding Society (AWS): AWS D1.1 - Structural Welding Code - Steel (copyrighted by AWS, ANSI approved). ASTM International (ASTM): 1.1 ASTM A 36/A 36M - Standard Specification for Structural Steel. National Association of Architectural Metal Manufacturers (NAAMM): NAAMM MFM - Metal Finishes Manual. National Fire Protection Association (NFPA): NFPA 70 - National Electrical Code (copyrighted by NFPA, ANSI approved) - hereinafter referred to as NEC. PERFORMANCE REQUIREMENTS Structural Performance: Provide pre-engineered canopies capable of withstanding the effects of gravity loads and the following loads and stresses within limits and under conditions indicated for the specific location where Canopy will be installed: 1.2 Uniform pressure as indicated on drawings - minimum design wind load per ASCE 7, CH. 6. Thermal Movements: Provide pre-engineered canopies that allow for thermal movements resulting from the following maximum change (range) in ambient and surface temperatures by preventing buckling, opening of joints, overstressing of components, failure of joint sealants, failure of connections, and other detrimental effects. Base engineering calculation on surface temperatures of materials due to both solar heat gain and nighttime-sky heat loss. 1.3 Temperature Change (Range): 120 degrees F (67 degrees C), ambient; 180 degrees F (100 degrees C), material surfaces. QUALITY ASSURANCE Welding: Qualify procedures and personnel according to the following: 1.4 Welding shall be in accordance with AWS D1.1 (with E70XX electrodes). 1.5 Steel shop connections shall be welded and field connections shall be bolted (unless otherwise noted on the Drawings). Shop welds may be changed to field welds with the approval of the project engineer. 1.6 Slag shall be cleaned from welds and inspected. Steel shall be painted with red oxide rust-inhibitive primer. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NEC, Article 100, by a testing agency acceptable to authorities having jurisdiction, and marked for intended use. Source Limitations: Obtain pre-engineered metal canopy through one source from a single manufacturer who shall manufacture and install the canopy. DELIVERY, STORAGE, AND HANDLING Store products in manufacturer's unopened packaging until ready for installation. Protect components and accessories from corrosion, deformation, damage, and deterioration when stored at job site. Keep materials free from dirt and foreign matter. PROJECT CONDITIONS Field Measurements: The Contractor shall verify location and elevation of footings relative to finished grade, columns, and other construction contiguous with pre-engineered metal canopies by field measurements before fabrication and indicate measurements on shop drawings. 1.7 Established Dimensions: The Contractor shall, where field measurements cannot be made without delaying the work, establish dimensions and proceed with fabricating metal canopies without field measurements. Contractor is responsible to coordinate footer locations and elevations with any interferences with or attachments to abutting structures. PART 2 -- MATERIALS Structural Steel: 1.8 Material and work shall conform to the latest AISC 360. 1.9 Structural steel shall be painted with a rust inhibitive (red oxide) primer (std). 1.10 Structural steel shall be hot-dip-galvanized. Sheet Metal: 1.11 Decking: 3 inch (76 mm) by 16 inch (406 mm) by 20 gage smooth EIGHT A325 3/4" BOLTS FOUR GUSSETS 4" x 3" x 3/8" FOUR GUSSETS 4" x 3" x 3/8" 3/8" WEB STIFFENERS 3" x 6" x 1/4" TS PURLINS. FIVE REQUIRED. COLUMNS: W10x22 A36 STEEL FOUR REQUIRED TOP PLATE DETAIL SCALE: 1" = 1'-0" REFLECTED PLAN 2 3"x6"x1/4" TS PURLINS SCALE: 1/8" = 1'-0" CANOPY LONGITUDINAL SECTION SEE TOP PLATE DETAIL THIS SHEET 2 COLUMNS W10x22 A36 STEEL EIGHT REQUIRED 3/8" WEB STIFFENERS 20 GAUGE SMOOTH WHITE DECK PANS CURB AT PUMPS SEE OTHER DRAWINGS 16" x 16" x 3/4" STEEL BASE PLATE 1/2" x 20' ANCHOR BOLTS FOUR REQUIRED AT EACH COLUMN 3000 PSI CONCRETE #6 REBARS 12" O.C. EACH WAY TOP OF FOOTER 24" BELOW GRADE.4'-0"16'-0"3'-0"2'-0"FOOTER SHALL BE MINIMUM 6'-0" NORTH-SOUTH AND 4'-0" EAST WEST SEE DRAINAGE PLAN GUTTER SYSTEM TYPICAL OF 14 3"x6"x1/4" TS PURLINS TYPICAL OF 14 COLUMNS: W10x22 A36 STEEL BREAK-METAL WRAP AROUND COLUMNS EIGHT COLUMNS REQUIRED W10 x 12 SUPPORT BEAMS W10 x 12 SUPPORT BEAMS W10 x 12 SUPPORT BEAMS CANOPY STRUCTURAL PLAN SCALE: 1/8" = 1'-0" 3"x6"x1/4" TS PURLINS STEEL DECK TOTAL 14 I I IREVISIONS:DRAWING COMPLETION DATE:4820 Buttonwood CrescentARCHITECT AIAGORDON CLARKIndianapolis, Indiana 46228Phone: 317 255-2546317 252-5573Fax: GClark4820@aol.comCONVENIENCE STORE / FOOD MARTVILLAGE OF WEST CLAYCARMEL, INDIANASOUTHWEST CORNER OFHARLESTON STREET AND TOWNE ROADOCTOBER 14, 2021 FOR PERMITTING AND CONSTRUCTIONA6.1 3"x6"x1/4" TS PURLINS TOTAL 14 PREFORMED GUTTER SYSTEM FRONT OF CANOPY FACIA STEEL DECK W10 x 12 SUPPORT BEAMS 20 GAUGE SMOOTH WHITE DECK PANS SCALE: 1" = 1'-0" EDGE OF CANOPY DETAIL1 A6.1 A6.1 A6.1A6.1 1 CANOPY DRAINAGE PLAN NORTH SCALE: 1/8" = 1'-0"SLOPE4" PVC DOWN INTERNAL GUTTER SYSTEM SLOPESLOPESLOPESLOPESLOPESLOPESLOPESLOPESLOPECOLUMNS SEE STRUCTURAL PLAN HIGH POINT IN GUTTERGUTTER BY FACIA SUPPLIER HIGH POINT IN GUTTER HIGH POINT IN GUTTER HIGH POINT IN GUTTER LIGHT FIXTURE CAN-304-PS-RD 304 SERIES CANOPY LUMINAIRE - PETROLEUM SYMETRIC RECESSED MOUNT FOR DOUBLE SKIN CANOPIES SEE CUT SHEETS ON THIS DRAWING. CONTROLS: ALL CANOPY LIGHTING SHALL BE CONTROLLED BY PHOTOCELL(S). PROVIDE STANDARD 110V SWITCH AT CASHIER AREA TO PROVIDE ON-OFF CAPABILITY FOR CANOPY LIGHTS. CLEARLY LABEL SWITCH. TYPICAL LIGHT FIXTURES AS DESCRIBED ON THIS SHEET SCALE: 1/8" = 1'-0" CANOPY REFLECTED CEILING PLAN SCALE: 1/8" = 1'-0" CANOPY SOUTH AND NORTH ELEVATION SCALE: 1/8" = 1'-0" CANOPY EAST AND WEST ELEVATION19'-6"16'-6"3'-0"6"16'-0"BOLLARDS (TYP.)3'-0"6"15'-616'-0"TOTAL 27 FIXTURES 104'-0"26'-0"A6.2 PIPE GUARD DETAIL 3'-2"3'-6"3'-0"3'-5"4" DIA. STEEL PIPE GUARD FILL WITH CONCRETE PAINT TRAFFIC YELLOW FINISHED GRADE CONCRETE PAVEMENT 15" DIA. CONCRETE FOOTING (TYP.) NOT TO SCALE REVISIONS:DRAWING COMPLETION DATE:4820 Buttonwood CrescentARCHITECT AIAGORDON CLARKIndianapolis, Indiana 46228Phone: 317 255-2546317 252-5573Fax: GClark4820@aol.comCONVENIENCE STORE / FOOD MARTVILLAGE OF WEST CLAYCARMEL, INDIANASOUTHWEST CORNER OFHARLESTON STREET AND TOWNE ROADOCTOBER 14, 2021 FOR PERMITTING AND CONSTRUCTION I I IREVISIONS:DRAWING COMPLETION DATE:4820 Buttonwood CrescentARCHITECT AIAGORDON CLARKIndianapolis, Indiana 46228Phone: 317 255-2546317 252-5573Fax: GClark4820@aol.comCONVENIENCE STORE / FOOD MARTVILLAGE OF WEST CLAYCARMEL, INDIANASOUTHWEST CORNER OFHARLESTON STREET AND TOWNE ROADOCTOBER 14, 2021 FOR PERMITTING AND CONSTRUCTION6" TO PUBLIC SEWER BACKFLOW PREVENTER BUILDING CLEAN OUT HAND SINK HAND SINK 4" 2" ADA WC ADA WC ADA LAV ADA LAV ADA UR C.O. 2" 2" 2" 2" FD FD 4" 4" 2" ENDURA XL100 M RATED GREASE INTERCEPTOR BELOW SLAB 3" 3" FD 2" 2" 3" 3 COMPARTMENT COMMERCIAL SS SINK MOP SINK ELECTRIC WATER HEATER ABOVE ON STEEL RACK 3" 3" SCALE: 1/4" = 1'-0" SANITARY SEWER PLAN FLOOR SINK FOR BEVERAGE DISPENSER. VERIFY LOCATION WITH OWNER PRIOR TO INSTALLATION. FLOOR SINK FOR ICE MACHINE. VERIFY LOCATION WITH OWNER PRIOR TO INSTALLATION. 2"2" 2" 4"4" 4" 4" 4" CONDENSATE FOR FREEZER COMPRESSOR PLUMBING – GENERAL NOTES AND SPECIFICATIONS: PLUMBING CONTRACTOR SHALL CONFIRM SIZES OR ESTABLISH SIZES OF WASTE, VENT AND SUPPLY AS REQUIRED TO MAKE A COMPLETE AND WORKING SYSTEM. THE SCOPE OF THE PLUMBING WORK INCLUDES FURNISHING, INSTALLING TESTING AND WARRANTY OF ALL PLUMBING WORK SHOWN ON THE PLUMBING DRAWINGS. THE PLUMBING CONTRACTOR ACKNOWLEDGES THAT HE IS AWARE THAT PLUMBING DRAWINGS ARE SCHEMATIC IN NATURE AND DO NOT SHOW ALL EQUIPMENT OR FITTINGS REQUIRED. LOCATIONS ARE DIAGRAMMATIC. PLUMBING CONTRACTOR SHALL ADJUST LOCATION OF PIPING AS REQUIRED. CONFIRM DETAILED LOCATIONS WITH OWNER IF CRITICAL. THIS PROJECT SHALL BE COMPLETE, OPERATIONAL AND MEET CURRENT STATE AND LOCAL CODES AND ORDINANCES IN EVERY WAY. THE CURRENT CODE IS THE 2012 INDIANA PLUMBING CODE (2006 INTERNATIONAL PLUMBING CODE WITH 2012 INDIANA AMENDMENTS) COORDINATE WORK WITH OTHER TRADES AND CONFIRM THAT CLEARANCES AND FITTING REQUIREMENTS ARE KEPT. MATERIALS AND WORKMANSHIP: ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND FIRST QUALITY. PROVIDE ALL NECESSARY CLIPS, HANGERS, FASTENERS, AND OTHER DEVICES REQUIRED FOR A COMPLETE JOB. ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED AND SUPPORTED IN A FIRST-CLASS AND WORKMANLIKE MANNER BY MECHANICS SKILLED IN THEIR PARTICULAR TRADES. A LICENSED PLUMBING CONTRACTOR SHALL PERFORM WORK. SANITARY SEWER SYSTEMS: PROVIDE CLEANOUTS WHERE REQUIRED, WHETHER SHOWN ON DRAWINGS OR NOT. PIPE IN GRADE BELOW FLOOR SLABS SHALL BE RIGID PVC SCHEDULE 40, TYPE 1, GRADE 1, COMPLYING WITH ASTM D2665 AND D-1784. PRESSURE TEST AND REPLACE DEFECTIVE MATERIALS AND CONNECTIONS. WASTE AND VENTS: SOIL, WASTE AND VENT LINES SHALL BE PVC SCHEDULE 40 ASTM D1785 WITH ASTM D2665 DWV SOCKET FITTINGS; OR, SERVICE WEIGHT CAST IRON, OR AS REQUIRED BY LOCAL CODES. SLOPE WASTE PIPING UNIFORMLY 1/8" PER FOOT MINIMUM. SLOPE VENT PIPING TO PREVENT CONDENSATION FROM SYSTEM. TEST SOIL, WASTE, AND VENT PIPING SHALL BE TESTED TO A MINIMUM 10 FEET OF HEAD MAINTAINED FOR A MINIMUM 15 MINUTES. REPLACE DEFECTIVE PIPE AND JOINTS AT NO ADDITIONAL COST TO OWNER. FLOOR DRAINS SHALL BE EQUAL TO SMITH 2010-A. FLOOR CLEANOUTS SHALL BE EQUAL TO SMITH 4021 OR 4021Y. WALL CLEANOUTS SHALL BE EQUAL TO SMITH 4710. PROVIDE AND INSTALL ALL REQUIRED OR SHOWN BACK-FLOW PREVENTERS. DOMESTIC WATER SYSTEM: WATER SUPPLY LINES SHALL BE OF TYPE "L" OR "K" COPPER AS REQUIRED BY LOCAL PLUMBING CODES. ALL WATER SUPPLY LINES SHALL BE RUN UNDER FLOOR SLAB AND UP PLUMBING WALLS. SIZE WATER SUPPLY AS REQUIRED FOR BUILDING USAGE. BACKFLOW PREVENTERS SHALL BE INSTALLED IF REQUIRED BY STATE AND LOCAL ORDINANCES. INSTALL WARM WATER LINES ON WARM SIDE OF CEILING INSULATION. BACKFLOW PREVENTERS SHALL BE INSTALLED IF REQUIRED BY STATE AND LOCAL ORDINANCES. INSTALL WARM WATER LINES ON WARM SIDE OF CEILING INSULATION. PRESSURE TEST TO 50 PSIG ABOVE OPERATING PRESSURE (125 PSIG MIN.) AND MAINTAIN PRESSURE FOR 15 MINUTES MINIMUM WITH NO PRESSURE LOSS. REPLACE DEFECTIVE MATERIALS AND CONNECTIONS. CLEAN, FLUSH AND DISINFECT ALL WATER PIPING IN ACCORDANCE WITH AWWA C601. INSTALL PID RATED SHOCK ABSORBERS IN COLD WATER LINES WHERE REQUIRED. ALL WATER SUPPLY (BOTH HOT AND COLD) LINES ABOVE FLOOR SLAB SHALL BE INSULATED WITH 3/4" ARMA FLEX TYPE INSULATION. INSTALL DIELECTRIC UNIONS WHERE DISSIMILAR METALS ARE CONNECTED. PLUMBING FIXTURES: FIXTURES SHALL BE COMPLETE WHEN FULLY INSTALLED, INCLUDING TRIM, VALVES, SUPPLIES AND ESCUTCHEONS. TRIM SHALL BE BRASS CHROME PLATED; FIXTURES SHALL BE WHITE, UNLESS OTHERWISE NOTED. SEAL CRACKS AROUND EACH FIXTURE AT WALL AND FLOOR WITH PERMANENTLY PLIABLE WHITE SILICONE SEALANT. STRICTLY FOLLOW ACCESSIBILITY STANDARDS NOTED BELOW. DOMESTIC WATER HEATING: PROVIDE GAS FIRED STORAGE WATER HEATER COMPLETE WITH POWER BURNER OR ELECTRIC WATER HEATER TO SIZE REQUIRED. TANK SHALL BE CONSTRUCTED IN ACCORDANCE WITH ASME CODE, STAMPED AND TESTED. TANK SHALL BE INSULATED. THE COMPLETE WATER HEATER SHALL BE LISTED BY UL, WITH LABEL ATTACHED. VENTING FOR GAS WATER HEATERS: UL APPROVED TYPE B DOUBLE-WALL GAS VENT PIPING. VENT EXTENDED 3 FEET ABOVE THE ROOF, MINIMUM TWO FEET HIGHER THAN ANY PORTION OF BUILDING WITHIN 10 FEET. ACCESSIBILITY STANDARDS: STRICTLY COMPLY WITH THE REQUIREMENTS OF UNIFORM FEDERAL ACCESSIBILITY STANDARDS (UFAS), THE ADA, AND IBC, INDIANA CODE CHAPTER 11. PROVIDE RAISED SEAT FOR THE ACCESSIBLE WATER CLOSETS, PROVIDE FLUSH ON ACCESS SIDE OF WC'S, TRAP TIGHT TO THE WALL UNDER LAVATORIES, INSULATE ALL WASTE AND WATER PIPING BELOW LAVATORIES, AS WELL AS ALL OTHER ADA REQUIREMENTS. THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY IF REQUIRED DIMENSIONS, CLEARANCES, OR STRUCTURAL CONDITIONS EXIST THAT COULD PREVENT THE ABOVE ACCESSIBILITY REQUIREMENTS FROM BEING STRICTLY FOLLOWED. TESTING: ALL PIPES SHALL BE PRESSURE TESTED PER STANDARD PRACTICE. REPLACE ALL DEFECTIVE LINES AND CONNECTIONS AT NO ADDITIONAL COST TO OWNER. MANUALS: TWO COPIES OF OPERATION AND MAINTENANCE MANUALS FOR MATERIALS INSTALLED PER WORK OF THIS SECTION SHALL BE DELIVERED TO OWNER PRIOR TO ACCEPTANCE OF THESE SPACES FOR OCCUPANCY. BACKFLOW PREVENTION DEVICES FOR BEVERAGE STATIONS: THE CONTRACT DOCUMENTS CONSIST OF THE DRAWINGS AND SPECIFICATIONS ON THE DRAWINGS. THE INTENT OF THE CONTRACT DOCUMENTS IS TO INCLUDE ITEMS NECESSARY FOR THE PROPER EXECUTION OF THE WORK. NEW CONSTRUCTION SHALL CONFORM TO ALL APPLICABLE CITY, STATE AND LOCAL BUILDING CODES AND NFPA CODES FOR THIS CLASS OF WORK. REQUIREMENTS: ALL WORK RELATED TO THE BEVERAGE DISPENSERS AND BEVERAGE AREAS SHALL BE PROTECTED BY THE PROVISIONS OF THE INDIANA PLUMBING CODE 2012 EDITION SECTIONS 608.16.1 AND 608.16.10. CONNECTIONS TO POTABLE WATER SYSTEM: SPECIFICALLY BEVERAGE DISPENSERS SHALL BE PROTECTED AGAINST BACKFLOW BY A BACKFLOW PREVENTER CONFORMING TO ASSE 1022. THE PORTION OF THE BACKFLOW PREVENTER DEVICE DOWNSTREAM FROM THE SECOND CHECK VALVE AND THE PIPING DOWNSTREAM THEREFROM SHALL NOT BE AFFECTED BY CARBON DIOXIDE GAS. COFFEE MACHINES AND NONCARBONATED BEVERAGE DISPENSERS: THE WATER SUPPLY CONNECTION TO COFFEE MACHINES AND NONCARBONATED BEVERAGE DISPENSERS SHALL BE PROTECTED AGAINST BACKFLOW BY A BACKFLOW PREVENTER CONFORMING TO ASSE 1022. INSTALLATION: BACKFLOW PREVENTERS SHALL BE INSTALLED STRICTLY ACCORDING TO MANUFACTURER’S WRITTEN INSTRUCTIONS AND ACCORDING TO THE CODES REFERENCED ABOVE. CONDENSATE LINE CONDENSATE LINE P1.1 DOMESTIC WATER DISTRIBUTION GENERAL REQUIREMENTS: PIPING SHALL BE SIZED TO PROVIDE A VELOCITY NOT EXCEEDING SIX FEET PER SECOND (FPS) FOR COLD AND HOT WATER SYSTEMS. PIPES: UNDERGROUND: ‘K” COPPER: BRAISED JOINTS; SLEEVES THRU CONCRETE. INSULATED IN GRAVEL BACKFILL. ABOVE SLAB: ‘L’ COPPER TUBING; CPVC PIPING, SCHEDULE 40 WITH SOLVENT WELDED JOINTS; PEX TUBING WITH BRASS FITTINGS. VENTING AND DRAINAGE: SCHEDULE 40 PVC WITH SOLVENT WELDED JOINTS. INSULATION: INTERIOR COLD WATER PIPING SHALL BE INSULATED TO PREVENT CONDENSATION. INTERIOR HOT WATER PIPING SHALL BE INSULATED AS REQUIRED BY CODE AND PER LATEST ASHRE STANDARD A90.1, TABLE 7.2.3. WALL HYDRANTS: PROVIDE FREEZE-PROOF WALL HYDRANTS ON EXTERIOR WALLS A MAXIMUM OF 150 FEET APART. LOCATE APPROXIMATELY 18” ABOVE FINISH GRADE. COORDINATE LOCATIONS WITH THE BUILDING OWNER AND THE PROJECT ARCHITECT. VALVES: PROVIDE ACCESSIBLE CHECK VALVES IN THE INDIVIDUAL COLD AND HOT WATER FIXTURE SUPPLY LINES SERVING MIXING VALVE TYPE FAUCETS OR ASSEMBILES HAVING HOSE CONNECTION OUTLETS THAT ARE NOT EQUIPPED WITH INTEGRAL CHECK STOPS. PROVIDE LINE SHUT-OFF VALVES AT LOCATIONS REQUIRED FOR PROPER OPERATION, SERVICING AND TROUBLESHOOTING OF THE DOMESTIC WATER DISTRIBUTION SYSTEM AND CONNECTED COMPONENTS. LOCATIONS SHALL INCLUDE BUT NOT BE LIMITED TO THE FOLLOWING: AT EACH FIXTURE AND PIECE OF EQUIPMENT; AT EACH BRANCH TAKE-OFF FROM MAINS; AT THE BASE OF EACH RISER; AT EACH BATTERY OF FIXTURES; WHERE RECOMMENDED BY EQUIPMENT MANUFACTURERS AND AT STRATEGIC LOCATIONS TO ALLOW FOR SECTIONAL ISOLATION WHILE LIMITING DISRUPTION OF SERVICES. ALL VALVES SHALL BE ACCESSIBLE FOR OPERATION AND SERVICING. TRAP PRIMING DEVICES THAT RELY UPON LINE PRESSURE DIFFERENTIAL FOR ACTIVATION ARE NOT ALLOWED. DOMESTIC HOT WATER SYSTEMS WATER HEATERS INSTALLED AND UTILIZED FOR FOOD WERVICE AREAS SHALL COMPLY WITH NATIONAL SANITATION FOUNDATION (NSF) STANDARD NUMBER 5. HOT WATER SERVING COMMERCIAL DISHWASHERS AND POT SINKS SHALL BE 140 DEGREES F. ALL OTHER HOT WATER SHALL BE 110 DEGREES MAXIMUM AT OUTLETS. CONTAMINATION PROTECTION: INSTALLATION OF DOMESTIC WATER SYSTEMS SHALL AVOID ALL CROSS CONNECTIONS AND ELIMINATE THE POSSIBILITY OF WATER CONTAMINATION. ON EACH WATER SUPPLY SERVING A FIXTURE WHERE A DISCHARGE LINE PROVIDES AN OPPORTUNITY WHERE CROSS CONTAMINATION COULD OCCUR, PROVIDE A VACUUM BREAKER OR BACKFLOW PREVENTER. I I IREVISIONS:DRAWING COMPLETION DATE:4820 Buttonwood CrescentARCHITECT AIAGORDON CLARKIndianapolis, Indiana 46228Phone: 317 255-2546317 252-5573Fax: GClark4820@aol.comCONVENIENCE STORE / FOOD MARTVILLAGE OF WEST CLAYCARMEL, INDIANASOUTHWEST CORNER OFHARLESTON STREET AND TOWNE ROADOCTOBER 14, 2021 FOR PERMITTING AND CONSTRUCTIONNOT TO SCALE PLUMBING ISOMETRIC EXPAND TO 3" THRU ROOF 2" TO ROOF 1 1/2" VENT EXPAND TO 3" THRU ROOF 2" TO ROOF 2" TO ROOF GREASE INTERCEPTOR: INSTALL GREASE INTERCEPTOR STRICTLY ACCORDING TO REQUIREMENTS OF THE PLUMBING AND DRAINAGE INSTITUTE (PDI) STANDARD PDI-G101. INSTALL GREASE INTERCEPTOR STRICTLY ACCORDING TO REQUIREMENTS OF THE CITY OF CARMEL, INDIANA. CAPACITY:PER CITY REGULATIONS AT A MINIMUM, THE FOLLOWING FIXTURES MUST BE CONNECTED THROUGH THIS GREASE INTERCEPTOR (“FOG” TYPE USES – FATS, OILS, GREASE): POT SINKS PRE-RINSE SINKS SOUP KETTLES SINKS INTO WHICK KETTLES ARE DRAINED AUTOMATIC HOOD WASHING UNITS BASIN SINKS MOP SINK THREE COMPARTMENT COMMERCIAL SINKS FIXTURES THAT SHOULD NOT BE CONNECTED TO THE GREASE INTERCEPTOR UNLESS REQUIRED BY LOCAL AUTHORITIES. TOILET ROOM FIXTURES HAND SINKS FLOOR DRAINS THE DRAWINGS ARE SCHEMATIC AND DO NOT SHOW ALL REQUIRED PARTS AND FITTINGS. IF INTERCEPTOR WILL BE UNDER AN AUTOMOBILE DRIVEWAY. IT SHALL BE THE SOLE RESPONSIBILITY OF THE INSTALLER TO PROVIDE REQUIRED INTERCEPTOR STRUCTURAL THICKNESS AND PAVING/CONCRETE COVER. NOTIFY ARCHITECT IMMEDIATELY IF CONDITIONS ARE NOT AS EXPECTED. STRICTLY FOLLOW WRITTEN INSTALLATION INSTRUCTIONS AND CITY INSTRUCTIONS. CO N D E N S AT E LI N E CONDENSATE LINEXL 100 GREASE INTERCEPTOR BELOW SLAB MOP SINK SS 3 COMP. SINK HAND SINK HAND SINK FLOOR SINK FLOOR SINK BLDG CLEANOUT BACKFLOW PREVENTER FD FD ADA WC ADA WC ADA LAV ADA LAV ADA UR P1.2 I I IREVISIONS:DRAWING COMPLETION DATE:4820 Buttonwood CrescentARCHITECT AIAGORDON CLARKIndianapolis, Indiana 46228Phone: 317 255-2546317 252-5573Fax: GClark4820@aol.comCONVENIENCE STORE / FOOD MARTVILLAGE OF WEST CLAYCARMEL, INDIANASOUTHWEST CORNER OFHARLESTON STREET AND TOWNE ROADOCTOBER 14, 2021 FOR PERMITTING AND CONSTRUCTION300 CFM 300 CFM 300 CFM 300 CFM 200 CFM 225 CFM 225 CFM 225 CFM 225 CFM 225 CFM 225 CFM 225 CFM 225 CFM 200 CFM 250 CFM 250 CFM 200 CFM 200 CFM 200 CFM 200 CFM 250 CFM 125 CFM 125 CFM 75 CFM EXHAUST 75 CFM EXHAUST EXHAUST TO DAYLIGHT INSTALL RAIN AND INSECT SCREEN 6" FLEX 6" FLEX DAMPER ALL BRANCHES 10" FLEX 10" FLEX 10" FLEX 10" FLEX 8" FLEX 8" FLEX 8" FLEX 8" FLEX DAMPER ALL BRANCHES DAMPER ALL BRANCHES 8" FLEX 8" FLEX 8" FLEX 8" FLEX DAMPER ALL BRANCHES 10" ROUND 10" ROUND 8" FLEX 8" FLEX DAMPERS 25" x 8" 8" FLEX 8" FLEX 32" x 8" GRILLES WITH DAMPERS COOLER PACKAGE BY MFGR. CONDENSER LINE TO DRAIN 200 CFM MECHANICAL SCHEDULE SCALE: 1/4" = 1'-0" MECHANICAL PLAN ROOFTOP COOLING-HEATING UNITS THE ROOFTOP UNITS SHALL BE FACTORY PACKAGED WITH CIRCULATING FAN, GAS-FIRED HEATING SECTION AND AIR-COOLED REFRIGERATION SECTION. UNIT SHALL BE ROOF CURB MOUNTED. UNIT SHALL BE RATED IN ACCORDANCE WITH ARI STANDARDS 270 AND 360 AND TESTED AND CERTIFIED BY UL OR ETL TO CONFORM TO APPLICABLE ANSI STANDARDS. A WALL MOUNTED SPACE THERMOSTAT SHALL BE FURNISHED WITH THE UNIT. THE REFRIGERATION SYSTEM AND FURNACE HEAT EXCHANGERS SHALL CARRY A FIVE-YEAR WARRANTY. PROVIDE CONDENSATE DRAINAGE PIPING FROM THE DRAIN PAN WITH A 4” DEEP TRAP AND CLEANOUT. THE ELECTRICAL CONTRACTOR WILL PROVIDE POWER WIRING THRU A FUSED DISCONNECT SWITCH ON ONE SET OF POWER TERMINALS IN EACH UNIT. ALL OTHER POWER AND CONTROL WIRING REQUIRED FOR THE COMPLETION OF THE SYSTEM SHALL BE FURNISHED AND INSTALLED BY THE HVAC CONTRACTOR. ALL WIRING BY ANY CONTRACTOR SHALL MEET OR EXCEED ALL STATE AND LOCAL CODES AND ORDINANCES. INSTALL A LOCAL DISCONNECT WITHIN THE LINE OF SIGHT OF TO ALL PERMANENTLY CONNECTED ROOFTOP EQUIPMENT. THIS CAN ALSO INCLUDE CONDENSERS FOR COOLER UNITS AND HOOD INTAKE AND EXHAUST FANS. PROVIDE A RECEPTACLE WITHIN 25 FEET OF THE ROOFTOP UNITS. IT SHALL BE GFIC PROTECTED. THE GFIC TESTING THE TRIPPING RESET SHOULB BE READILY ACCESSIBLE FOR SERVICING OF ROOFTOP EQUIPMENT. PROVIDE “WHILE-IN-USE” WEATHERPROOF COVERS FOR RECEPTACLES INSTALLED IN A WET LOCATION SO THAT THE RECEPTACLE REMAINS WATERTIGHT WHILE A CORD IS PLUGGED IN. MECHANICAL SPECIFICATIONS AND GENERAL REQUIREMENTS: THE CONTRACT DOCUMENTS CONSIST OF THE DRAWINGS AND SPECIFICATIONS ON THE DRAWINGS. THE INTENT OF THE CONTRACT DOCUMENTS IS TO INCLUDE ITEMS NECESSARY FOR THE PROPER EXECUTION OF THE WORK. NEW CONSTRUCTION SHALL CONFORM TO ALL APPLICABLE CITY, STATE AND LOCAL BUILDING CODES AND NFPA CODES FOR THIS CLASS OF WORK. MECHANICAL CONTRACTOR IS RESPONSIBLE FOR ALL APPLICABLE PERMITS, INSPECTIONS AND LICENSES NECESSARY TO COMPLETE THIS INSTALLATION AND THE SATISFACTORY OPERATION OF THE SYSTEM. MECHANICAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND DIMENSIONS AT THE JOBSITE. IF DISCREPANCIES ARE FOUND THE GENERAL CONTRACTOR SHALL BE NOTIFIED BEFORE PROCEEDING WITH ANY WORK OR ORDERING ANY EQUIPMENT OR MATERIAL IN THE AFFECTED AREA. FIT AND QUANTITY OF THE MECHANICAL SYSTEMS TO BE INSTALLED, WITH THE VARIOUS NECESSARY PARTS AND MATERIALS TO MAKE A COMPLETE AND FINISHED JOB, SHALL BE VERIFIED AND COORDINATED PRIOR TO START OF CONSTRUCTION AND ARE THE EXCLUSIVE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR. THE MECHANICAL CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER TRADES AND VERIFY ALL POWER AND DRAINS ARE PROVIDED AND IN THE PROPER LOCATION. ALL EQUIPMENT AND MATERIALS SHALL BE INSTALLED PER THE MANUFACTURER'S SUGGESTED INSTALLATION REQUIREMENTS IN A NEAT AND WORKMANLIKE MANNER. MECHANICAL DRAWINGS ARE DIAGRAMMATIC AND MUST BE FIELD VERIFIED FOR EXACT ROUTING AND ADDITIONAL EQUIPMENT OR DEVICES NECESSARY FOR COMPLETE JOB. MECHANICAL CONTRACTOR SHALL PROVIDE ALL CONTACTORS, RELAYS AND THERMOSTATS. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL SWITCHES AND DISCONNECTS. THE MECHANICAL CONTRACTOR SHALL COMPLETE TEMPERATURE CONTROL WIRING. PROVIDE ALL NECESSARY HANGERS, FASTENERS, CLIPS AND OTHER DEVICES REQUIRED FOR A COMPLETE JOB. SUPPORT: SUSPENDED TYPE UNIT HEATERS SHALL BE SUPPORTED BY ELEMENTS THAT ARE DESIGNED AND CONSTRUCTED TO ACCOMMODATE THE WEIGHT AND DYNAMIC LOADS. HANGERS AND BRACKETS SHALL BE OF NONCOMBUSTIBLE MATERIAL. USE UNISTRUT-TYPE SUPPORT MATERIALS RATED FOR WEIGHT OF THE UNITS. CONNECT TO STRUCTURAL ELEMENTS. NO CONNECTIONS TO ROOFING MATERIALS SHALL BE ALLOWED. GAS PIPING SPECIFICATIONS: BLACK STEEL: 2" OR SMALLER-SCHEDULE 40, GRADE "B" ASTM A120 SCREWED 150 PSI BLACK MALLEABLE IRON FITTINGS. VALVES: PLUG TYPE GAS SUPPORTS SHALL BE MINIMUM OF 10'-0" O.C. ALL HVAC UNITS SHALL BE INSTALLED COMPLETE WITH ECONOMIZERS, LOW AMBIENT KITS, AND REQUIRED CURBS, ETC. MANUFACTURER'S MINIMUM CLEARANCE RECOMMENDATIONS SHALL BE MAINTAINED ON ALL EQUIPMENT AND DUCTWORK. ALL EXHAUST DUCTWORK SHALL BE METAL ROUND DUCTWORK. NO FLEXIBLE ROUND DUCTWORK SHALL BE USED. ALL MAIN DUCTS SHALL BE GALVANIZED STEEL WRAPPED WITH FOIL-BACK INSULATION OR DUCT BOARD. INSTALL PER SMACNA STANDARDS. TURNING VANES SHALL BE INSTALLED AT ELBOWS LARGER THAN 12" X 12". ALL METAL DUCTWORK SHALL BE FABRICATED FROM GALVANIZED SHEET STEEL OF GAUGES, REINFORCEMENT COMPLYING WITH SMACNA "HVAC DUCTWORK CONSTRUCTION STANDARDS." THE ARCHITECT SHALL HAVE ACCESS TO THE CONSTRUCTION SITE AND HAVE THE RIGHT TO REJECT ANY WORK (AFTER CONSULTATION WITH THE GENERAL CONTRACTOR) THAT DOES NOT CONFORM TO THE DRAWINGS, SPECIFICATIONS, CODES OR WORK THAT HAS NOT BEEN EXECUTED IN A WORKMANLIKE MANNER. CONTRACTOR SHALL BE RESPONSIBLE FOR NOTICE TO THE INSPECTING AUTHORITIES, ARCHITECT, OR GENERAL CONTRACTOR, SO THAT WORK CAN BE INSPECTED OR APPROVED BEFORE COVERING. THIS PROCEDURE SHALL OCCUR WITHOUT AFFECTING CONSTRUCTION PROGRESS AND COMPLETION. THE INTENTION OF THESE DOCUMENTS IS TO PROVIDE THE OWNER WITH A BUILDING COMPLETE IN ITS ENTIRETY AT THE TIME OF OCCUPANCY. IT IS THE SUB-CONTRACTOR'S RESPONSIBILITY TO CONTRACT THE GENERAL CONTRACTOR DURING THE BIDDING/PRICING PHASE OF ANY DETAILS MISSING, VAGUE, ORE INCOMPLETE SO THAT AN APPROPRIATE ADDENDUM OR CLARIFICATION CAN BE ISSUED. THE SELECTED CONTRACTOR SHALL PROVIDE ALL MATERIALS, LABOR, TOOLS, EQUIPMENT, AND SERVICES NECESSARY FOR A COMPLETE, FUNCTIONAL, AND OPERATIONAL FACILITY. TWO COPIES OF OPERATION AND MAINTENANCE MANUALS FOR MATERIALS INSTALLED PER WORK OF THIS SECTION SHALL BE DELIVERED TO OWNER PRIOR TO ACCEPTANCE OF THESE SPACES FOR OCCUPANCY. RTU #1 RTU #2 4 TON 6 TON BEVERAGE COOLER COOLING BY MANUFACTURER PROVIDE CONDENSATE LINE TO APPROPRIATE DRAIN LOCATION FREEZER. COOLED BY MANUFACTURER M1.1 I I IREVISIONS:DRAWING COMPLETION DATE:4820 Buttonwood CrescentARCHITECT AIAGORDON CLARKIndianapolis, Indiana 46228Phone: 317 255-2546317 252-5573Fax: GClark4820@aol.comCONVENIENCE STORE / FOOD MARTVILLAGE OF WEST CLAYCARMEL, INDIANASOUTHWEST CORNER OFHARLESTON STREET AND TOWNE ROADOCTOBER 14, 2021 FOR PERMITTING AND CONSTRUCTIONSSS SSSSSS333 3S3E1.1 A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A B B B C C C C C C C D D D D A A A A D D EEEEE E E E E FREEZER BY OTHERSCOOLER BY OTHERS SCALE: 1/4" = 1'-0" ELECTRICAL LIGHTING PLAN SYMBOLS 24" x 24" LAY-IN LED PANEL 24" x 48" LAY-IN LED PANEL A B C LINEAR 96" SUSPENDED LED FIXTURE D E LED CAN LIGHT AT BEVERAGE AND FOOD COUNTERS COOLER AND FREEZER LIGHTS PROVIDED AND INSTALLED BY COOLER MFGR. MINIMUM 24" x 30" ATTIC ACCESS F F F F F SURFACE MOUNTED ART DECO FIXTURE MODERN FORMS SKYSCRAPER SEE CUT SHEET AT LEFT SCALE: 1/4" = 1'-0" I I IREVISIONS:DRAWING COMPLETION DATE:4820 Buttonwood CrescentARCHITECT AIAGORDON CLARKIndianapolis, Indiana 46228Phone: 317 255-2546317 252-5573Fax: GClark4820@aol.comCONVENIENCE STORE / FOOD MARTVILLAGE OF WEST CLAYCARMEL, INDIANASOUTHWEST CORNER OFHARLESTON STREET AND TOWNE ROADOCTOBER 14, 2021 FOR PERMITTING AND CONSTRUCTION220V GFI GFI GFI GFI HIGH FOR SIGN AND/OR SHOW WINDOWS POS POS DED DED DED GFI GFI GFI GFI DRAWING NOTES: 1. 2. 3. 4. 5. MINIMUM WIRE SIZE TO BE #12 AWG COPPER INSTALLATION TO MEET ALL STATE AND LOCAL CODES. ALL WIREING TO BE INSTALLED IN METAL RACEWAYS OR MC CABLE WHERE PERMITTED BY CODE. MAXIMUM LOAD OF 1,600 WATTS FOR 20 AMP BRANCH CIRCUITS. FINAL LOCATIONS OF ALL DEVICES AND EQUIPMENT CONNECTIONS TO BE VERIFIED BY THE OWNER. ELECTRICAL RISER DIAGRAM 2-1 2" PVC CONDUIT WITH (4) 4 0 AL AND (1) #2 GROUND WIRE NOT TO SCALE SUPPLY FAN: USE CIRCUIT 20 115 V 1/2 HP 4.80 AMPS EXHAUST FAN: USE CIRCUIT 22 115 V 3/4 HP 13.80 AMPS CONDENSER USE CIRCUIT 24 20 AMP 2 POLE EVAPORATOR USE CIRCUIT 26 15 AMP 2 POLE FOR HOOD SYSTEM (FUTURE) GROUND ROD TO #6 THHN #4 THHN TO THE BUILDING STEEL DISCONNECT 200 AMP 3 PHASE 42 SPACE PANEL GROUND ROD TO #6 THHN #4 THHN TO THE BUILDING STEEL DISCONNECT 200 AMP 3 PHASE 42 SPACE PANEL METER BASE AS REQUIRED #4 THHN TO THE BUILDING STEEL SUB-PANEL GROUND ROD TO #6 THHN FOR FUEL SYSTEMS100 AMP SINGLE PHASE USE DUAL RATED THHN WIRE 4 WIRE PER CABLE FOR COOLERS AND FREEZER DISCONNECT 20A/2P CIRCUIT FOR CONDENSER IN COOLER AND FREEZER 15A/2P CIRCUIT FOR LIGHTS 200 AMP 200 AMP 100 AMP 400 AMP CT CABINET TWO 200 AMP DISCONNECTS METER BASE FEED FROM PUBLIC SERVICE LOCATE PER LOCAL UTILITY REQUIREMENTS UNDERGROUND SERVICE DRIVEWAY RATED SODA ON ONE CIRCUIT 2 RECEPT. GFI GFI GFI GFI GFI GFI GFI GFIGFI 15A/2P CIRCUIT FOR EVAPORATOR ENTIRE BEVERAGE AREA 11 RECEPTACLES ON 8 CIRCUITS COUNTS SODA INDICATED ALL GFI PROTECTED FOOD SERVICE AREA 5 RECEPTICLES ON 2 CIRCUITS GFI GFI GFI GFI GFI GFI ELECTRICAL POWER PLAN POS FREEZER SIMILAR TO COOLER REQUIREMENTS 110V DUPLEX RECEPTICAL GFI 110 V RECEPTICAL GF PROTECTED DED 110 V RECEPTICAL, DEDICATED 220 B RECEPTICAL220V PHONE / DATA OUTLET SYMBOLS ELECTRICAL SPECIFICATIONS AND GENERAL REQUIREMENTS: THE CONTRACT DOCUMENTS CONSIST OF THE DRAWINGS AND SPECIFICATIONS ON THE DRAWINGS. THE INTENT OF THE CONTRACT DOCUMENTS IS TO INCLUDE ITEMS NECESSARY FOR THE PROPER EXECUTION OF THE WORK. BUILDING CODES: NEW CONSTRUCTION SHALL CONFORM TO ALL APPLICABLE CITY, STATE AND LOCAL BUILDING CODES FOR THIS CLASS OF WORK. ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND DIMENSIONS AT THE JOBSITE. IF DISCREPANCIES ARE FOUND THE GENERAL CONTRACTOR SHALL BE NOTIFIES BEFORE PROCEEDING WITH ANY WORK OR ORDERING ANY EQUIPMENT OR MATERIAL IN THE AFFECTED AREA. FIT AND QUANTITY OF THE WIRING, ELECTRICAL EQUIPMENT, THE VARIOUS NECESSARY PARTS AND MATERIALS TO MAKE A COMPLETE AND FINISHED JOB SHALL BE VERIFIED AND COORDINATED PRIOR TO START OF CONSTRUCTION AND ARE THE EXCLUSIVE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. LOCAL UTILITY COORDINATION: ELECTRICAL CONTRACTOR SHALL COORDINATE TRANSFORMERS AND SERVICE REQUIREMENTS WITH THE LOCAL UTILITY COMPANY. THE E.C. SHALL CONSULT WITH THE LOCAL UTILITY TO ESTABLISH REQUIRED kACI RATINGS. ALL FIXTURES, EQUIPMENT AND MATERIALS SHALL BE INSTALLED PER THE MANUFACTURER'S SUGGESTED INSTALLATION REQUIREMENTS IN A NEAT AND WORKMANLIKE MANNER. UL LABELING: ALL ELECTRICAL EQUIPMENT SHALL HAVE "UL" LABELS. WIRING DEVICES SHALL BE SPECIFICATION GRADE. PROVIDE ALL DISCONNECTS REQUIRED PER NATIONAL AND LOCAL ELECTRICAL CODES RATED TO UTILITY SUPPLIED kAIC LIMITS, OR, IF NOT SUPPLIED, TO NEC MINIMUMS. ALL EXPOSED WIRE AND WIRING BELOW CONCRETE SLABS SHALL BE IN CONDUIT. WIRE: ALL WIRE SHALL BE COPPER, MINIMUM SIZE #12 AWG. ALL CONDUCTORS SHALL HAVE TYPE "THHN" INSULATION. CONDUCTORS #10 AND SMALLER MAY BE SOLID. GROUNDING CABLES SHALL BE NO SMALLER THAN 4 COPPER. BREAKER PANELS: FURNISH AND INSTALL A BREAKER PANEL AS MANUFACTURED BY SQUARE D OR ITE. INSTALL PANEL SO TOP BREAKER IS NO HIGHER THAN 6'-0". FURNISH AND INSTALL TYPEWRITTEN DIRECTORY. IDENTIFY AND LABEL ALL ELECTRICAL SERVICE EQUIPMENT. GROUNDING: GROUNDING SHALL BE DONE STRICTLY ACCORDING TO SECTION 250.52 OF THE NATIONAL ELECTRIC CODE USING ACCEPTABLE ELECTRODES AND CONNECTIONS. SWITCHES: ALL SWITCHES SHALL BE RATED 20 AMP, 125 VOLT AND SHALL BE MOUNTED 4'-6" AFF, UNLESS NOTED OTHERWISE. RECEPTICALS: ALL RECEPTACLES TO BE 15 AMP, 125 VOLT, GROUNDING TYPE AND SHALL BE MOUNTED 18" AFF, UNLESS NOTED OTHERWISE. PROVIDE TEMPORARY POWER REQUIRED BY THE GENERAL CONTRACTOR AND OTHER TRADES. COORDINATE POWER REQUIREMENTS WITH GC PRIOR TO INSTALLATION. LIGHTING FIXTURES: LIGHTING FIXTURES TO BE FURNISHED AND INSTALLED COMPLETE WITH LAMPS AS DETAILED ON THE PLANS OR AS INTENDED. SEE REFLECTED CEILING PLAN AND/OR LIGHTING PLAN FOR THE EXACT LOCATION OF THE CEILING GRID, LIGHT FIXTURES, OR THE GENERAL INTENT OF THE DRAWINGS. SEE THE ELECTRICAL DRAWING(S) FOR THE FIXTURE SCHEDULE, NOTES AND OTHER SPECIFICATION REQUIREMENTS. CONTRACTOR SHALL BE RESPONSIBLE FOR NOTICE TO THE INSPECTING AUTHORITIES, ARCHITECT, OR GENERAL CONTRACTOR, SO THAT WORK CAN BE INSPECTED OR APPROVED BEFORE COVERING. THIS PROCEDURE SHALL OCCUR WITHOUT AFFECTING CONSTRUCTION PROGRESS AND COMPLETION. THE INTENTION OF THESE DOCUMENTS IS TO PROVIDE THE OWNER WITH A BUILDING COMPLETE IN ITS ENTIRETY AT THE TIME OF OCCUPANCY. IT IS THE SUB-CONTRACTOR'S RESPONSIBILITY TO CONTACT THE GENERAL CONTRACTOR DURING THE BIDDING/PRICING PHASE OF ANY DETAILS MISSING, VAGUE, OR INCOMPLETE SO THAT AN APPROPRIATE ADDENDUM OR CLARIFICATION CAN BE ISSUED. THE SELECTED CONTRACTOR SHALL PROVIDE ALL MATERIALS, LABOR, TOOLS, EQUIPMENT, AND SERVICES NECESSARY FOR A COMPLETE, FUNCTIONAL, AND OPERATIONAL FACILITY. E1.2