HomeMy WebLinkAboutLS100.0 - Life Safety Plan, South CollegeUP UPUP UPCHEM LAB 164 964 SF x STORAGE 163 8'-3"9'-8" x STG 165 8'-3"9'-8" A+P LAB 162 1126 SF NURSINGLAB 146 1107 SF CLASSROOM 167 906 SF x STG 147 13'-1"6'-0" x STG 149 6'-0"13'-1" x EXAM 150 11'-9"9'-5" x EXAM 153 10'-0"7'-10" ASSESSMENT LAB 148 1295 SF x CONF 128 20'-6"12'-6" RADIOLOGY LAB 166 734 SF OPEN OFFICE20 STATIONS 126 ULTRASOUND LAB 159 1051 SF x OFFICE 118 9'-7"13'-10" x OFFICE 117 13'-10"9'-7" x OFFICE 106 10'-0"12'-0" x OFFICE 102 10'-0"12'-0" x OFFICE 105 10'-0"12'-0" x OFFICE 104 10'-0"12'-0" x OFFICE 103 10'-0"12'-0" x OFFICE 115 9'-7"13'-10" x OFFICE 114 9'-7"13'-10" x OFFICE 113 9'-7"13'-10" x OFFICE 112 9'-7"13'-10" x OFFICE 116 9'-7"13'-10" ENTRY 101 x TESTING 109 21'-0"6'-2" COPY 107 CLASSROOM 139 1397 SF CLASSROOM 138 1467 SF STUDY 144 125 SF STAFF BREAK 132 x IT STG 160 11'-7"9'-1" x SERVER 161 11'-7"7'-4" x STORAGE / IT 140 11'-2"12'-7" CLASSROOM 154 678 SF x EXAM 152 10'-0"7'-10" x EXAM 151 11'-9"7'-10" 6x8 6x8 6x8 6x8 x OFFICE 119 9'-7"13'-10" x OFFICE 120 9'-7"13'-10" x OFFICE 121 9'-7"13'-10" x OFFICE 122 12'-2"13'-10" x CONFERENCE 123 17'-0"14'-7" 6x8 6x8 6x8 6x8 6x8 COMPUTER LAB 170 594 SF ENTRY 169 LIBRARY /RESOURCE LAB 168 431 SFREFRIGBYTENANTVEND. x STUDY 155 12'-10"17'-2" STUDENT CENTER 141 1443 SF 6x8 6x8 6x8 6x8 6x8 6x8 6x8 6x8 6x8 x FIRE-RATEDFILES 137 7'-6"12'-1" OFFICE 111 144 SF x OFFICE 110 11'-7"14'-1" x TESTING 108 21'-0"6'-2" x OFFICE 124 13'-0"16'-6" STUDY 145 143 SF (45 OCCUPANTS AT 20 SF/PERSON) STUDY 143 123 SF STUDY 142 148 SF VEND. VEND.VEND. VEND.x OFFICE 130 8'-1"11'-5" SIM LAB 156 349 SF SIM LAB 158 350 SF x CONTROLROOM 157 9'-0"22'-4" x OFFICE 136 9'-0"10'-0" x OFFICE 135 9'-0"10'-0" x OFFICE 134 9'-0"10'-0"6x86x86x8x OFFICE 131 18'-3"14'-8" OPEN OFFICE3 STATIONS 133 ENTRY 127 RR 129 (15 OCCUPANTS AT 50 SF/PERSON) (20 OCCUPANTS AT 50 SF/PERSON) (23 OCCUPANTS AT 50 SF/PERSON) (22 OCCUPANTS AT 50 SF/PERSON) (30 OCCUPANTS AT 20 SF/PERSON) (7 OCCUPANTS AT 50 SF/PERSON) (7 OCCUPANTS AT 50 SF/PERSON) (26 OCCUPANTS AT 50 SF/PERSON) (23 OCCUPANTS AT 50 SF/PERSON) (34 OCCUPANTS AT 20 SF/PERSON) (74 OCCUPANTS AT 20 SF/PERSON) (70 OCCUPANTS AT 20 SF/PERSON) EXIT DISCHARGE 171 ELELHALL 172 EL EL CLOSET 125 ELNELNELN ELNELNELN ELNELNELNELNELN ELNE L NEL EL FEFEFEFE FEFEFEFEFEFEELN ELNELNELNELNELNELN FE ELN REF RI GBYTENANT LIFE SAFETY PLAN L100LIFE SAFETY PLAN DESCRIPTIONDATE ISSUE 05.05.21 REVIEW SET 05.14.21 PERMIT SET 06.08.21 CONSTRUCTION SET REVISIONS DESCRIPTIONMARK DATE DB 06.08.21 AS REV 1 THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. PROJECT NUMBER DRAWN BYPROJ. MGR 450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comSOUTH COLLEGEPENN ON PKWY | 1ST FLOOR301 PENNSYLVANIA PKWY, INDIANAPOLIS, IN 46280AS/EHAS 2020.325 N LIFE SAFETY NOTES GENERAL NOTES 1ST FLOOR AREA NOT IN CONTRACT AREA OF WORK SCOPE OF WORK NURSING INSTRUCTION FOR HIGHER ED (ABOVE 12TH GRADE) + ADMINISTRATIVE OFFICE BUILD OUT OF PREVIOUS OFFICE BUILDOUT TOTAL BUILDING AREA TOTAL PROJECT AREA CHANGE OF OCCUPANCY CLASS? OCCUPANCY CALCULATIONS SPACE TYPE AREA SF PER OCCUPANT OCCUP LOAD NO OCCUPANCY CLASSIFICATION B(USINESS) OFFICE SF CLASSROOM 138 + 139 STUDENT CENTER 141 100 20 15 2,864 1,443 SF SF SPRINKLER SYSTEM (YES/NO) YES - EXISTING TO REMAIN TOTAL AREA OF ACCESSORY USES 1,443 TOTAL AREA ON THE FLOOR SF SF/FLOOR X STORIES SF SF 33,592 SF ACCESSORY AREA EXCEEDS 10% NO FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS (IF REQUIRED) EXISTING TO REMAIN + NEW AS REQUIRED AT EXIT DISCHARGE (SEE PLAN) = TOTAL OCCUPANTS IN PROJECT AREA 484 144 97 CODE SUMMARY PREVIOUS USE OF SPACE B(USINESS) ASHRAE 90.1 SUMMARY EXEMPT (SEE REFLECTED CEILING PLAN) BUILT BEFORE 1978? NO 24,280 28,587 33,592 4 134,368 243 BUILDING CONSTRUCTION TYPE II-B L1. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION DETAILS. L2. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS AS REQUIRED TO MEET ALL LOCAL AND STATE CODES. EXISTING ELECTRICAL PANEL LOCATION EXISTING EXIT EP EX LEGEND FIRE EXTINGUISHER EXIT SIGN FE EMERGENCY LIGHT FE TRAVEL DISTANCE NUMBER OF EXITS REQUIRED: 2 PROVIDED: 4 - LED EDGE LIT NOTES: - CLASSROOMS + LABS WILL BE UTILIZED FOR STUDENTS ABOVE GRADE 12 AND CLASSIFIED AS BUSINESS GROUP (B) PER IBC2012 SECTION 304.1. - CLASSROOMS + LABS UNDER 50 OCCUPANTS ARE CLASSIFIED AS (B) OCCUPANCY PER IBC2012 SECTION 303.1.2 1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. 4. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 5. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. NOT TO SCALE EX EX EX EX EX EP TRAVEL DISTANCE = 130'TRAVEL DISTANCE = 120' TRAVEL DISTANCE = 190' NEW WALLS AT EXIT DISCHARGE TO BE RATED ASSEMBLIES TO MATCH ADJACENT WALLS FIRE RATED ASSEMBLY TO MATCH NEW WALLS AT EXIT DISCHARGE TO BE RATED ASSEMBLIES TO MATCH ADJACENT WALLS ADJACENT WALL CONSTRUCTION 01/11/22