HomeMy WebLinkAboutRCP100.2 - Reflected Ceiling Plan-South, South CollegeUP UP
UP
EL
S N6
S NSNSNS NS N
SNSNSNELNELNELNELNS N S N6
ELN
ELNSN6SN6ELNS N
S N
S N SNS N S N SNSNS NS NSN
SNS NS NELNL
N L
NL
NL
NL
ELNSN3S N S NELN
REFLECTED
CEILING PLAN
A122REFLECTED CEILING PLAN
DESCRIPTIONDATE
ISSUE
05.05.21 REVIEW SET
05.14.21 PERMIT SET
06.08.21 CONSTRUCTION SET
REVISIONS
DESCRIPTIONMARK DATE DB
06.08.21 AS REV 1
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
PROJECT NUMBER
DRAWN BYPROJ. MGR 450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comSOUTH COLLEGEPENN ON PKWY | 1ST FLOOR301 PENNSYLVANIA PKWY, INDIANAPOLIS, IN 46280AS/EHAS
2020.325
N
0 2' 4' 8' 16'
PLAN NOTES
CONTRACTOR TO CONSULT WITH LANDLORD TO CONFIRM IF
EXISTING COOLING IS PRESENT; PROVIDE NEW AS REQUIRED +
COORDINATE WITH TENANTS ON ALL REQUIREMENT.
CONTROL LIGHTING IN THIS AREA WITH 3-WAY SWITCH AT THIS
LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED.
PROVIDE POWER FOR AUTOMATIC RECESSED PROJECTOR SCREEN
(BY TENANT) AT THIS LOCATION. COORDINATE WITH TENANT ON
FINAL LOCATION OF SCREEN AND CONTROL SWITCH/PANEL.
PROVIDE NEW CEILING GRID AND TILE TO MATCH AND ALIGN
WITH EXISTING SUCH THAT NEW AND EXISTING CEILINGS APPEAR
CONTINUOUS. AT AREAS OF NEW CEILING THAT ARE NOW
CONTINUOUS WITH COMMON AREA, PROVIDE BUILDING
STANDARD LIGHTING + DIFFUSERS AND ALL REQUIRED LIFE SAFETY
ELEMENTS.
ALL NEARBY CAN LIGHTING TO BE CONTROLLED BY THIS SWITCH.
INSTALL CEILING PROJECTOR (BY TENANT) AT THIS LOCATION.
CONFIRM FINAL LOCATION AND REQUIREMENTS WITH TENANT.
CONTROL SOUTH WING SUITE CORRIDOR LIGHTING WITH 6-WAY
SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS
REQUIRED.
EXISTING BULKHEAD TO REMAIN AND BE PAINTED BRIGHT CEILING
WHITE, FLAT FINISH.
IN AREA TO BE EXPOSED TO DECK, REPLACE LOW PRESSURE
SUPPLY BRANCH LINE DUCT AND WITH NEW RIGID SPIRAL DUCT
AND ROUND SUPPLY DIFFUSERS AS REQUIRED. CLEAN AND
PREPARE FOR DRYFALL PAINT (PT4). AS SPECIFIED, PAINT EXISTING
EXPOSED CEILING DECK, EXPOSED DUCTWORK, SPRINKLER PIPING,
JUNCTION BOXES, CONDUIT, STRUCTURAL BEAMS FIREPROOFING,
ETC. IN ACCORDANCE WITH NFPA 13 6.3.8.
NOTE: NOT ALL PLAN NOTES ARE USED ON EACH SHEET.
LIGHT CIRCUIT
LIGHT SWITCH, DIMMER
LIGHT SWITCH, 3-WAY
LIGHT SWITCH
ND
N
N3
D
3
EXIT LIGHT FIXTURE
UPLIGHT GROUP: PILKE
P18 PENDANT, COLOR:
WHITE STAINED #SF-P1805
RECESSED LIGHT
FIXTURE, RELOCATED
LIGHT FIXTURE, 2'x2',
FLUORESCENT, LED
LIGHT FIXTURE, 2'x4',
FLUORESCENT, LED
RELOCATED DIFFUSER,
LAY-IN, 4"x4'
RELOCATED DIFFUSER,
LAY-IN, 2'x2'
CEILING GRID,
SUSPENDED, 2'x2'
NIGHT LIGHT
NEW OR RELOCATED EXISTING TO REMAIN
AXIS LIGHTING: STENCIL
PENDANT, COLOR: WHITE,
LENGTHS VARY, BOTTOM
OF FIXTURES MOUNTED AT
11'-6" AFF. COORDINATE
EXACT SPECIFICATIONS
AND REQUIREMENTS WITH
ESL SPECTRUM: JENNIFER
HALL 317.750.7221
jhall@esl-spectrum.com
LIGHT FIXTURE,
PENDANT
EXIT LIGHT FIXTURE
LIGHT CIRCUIT
LIGHT SWITCH, DIMMER
LIGHT SWITCH, 3-WAY
LIGHT SWITCH
CEILING GRID,
SUSPENDED, 2'x2'
DIFFUSER,
LAY-IN, 4"x4'
DIFFUSER,
LAY-IN, 2'x2'
GYPSUM BOARD CEILING
LIGHT FIXTURE, 2'x2',
FLUORESCENT, LED
LIGHT FIXTURE, 2'x4',
FLUORESCENT, LED
LEGEND
RECESSED LIGHT
FIXTURE
EMERGENCY LIGHT FIXTURE EMERGENCY LIGHT FIXTURE
EXHAUST FAN, 2'x2'
GYPSUM
BOARD
CEILING
EXPOSED TO DECK
1
1
1ST FLOOR - S
AREA NOT IN CONTRACT
AREA OF WORK
1. REUSE EXISTING CEILING GRID AND TILE UNLESS OTHERWISE NOTED.
EXISTING GRID IS 2x2 AT APPROXIMATELY 9'-11" A.F.F. EXACT CEILING
HEIGHTS MAY VARY BETWEEN SUITES - COORDINATE WITH SDI AS
REQUIRED. TILES ARE 2x2 ACOUSTICAL LAY IN TILES. REPAIR ANY
DAMAGED GRID AND REPLACE ANY DAMAGED TILES WITH NEW TO
MATCH EXISTING.
2. IF IN GOOD CONDITION, EXISTING CEILING TILES SALVAGED FROM
DECONSTRUCTION CAN BE SUBSTITUTED FOR NEW. PROVIDE LIKE
CEILING TILES IN INDIVIDUAL ROOMS WHERE POSSIBLE TO CREATE
UNIFORM LOOK.
3. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON
PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN
SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI
OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT
IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.
4. UNLESS NOTED OTHERWISE, THE LIGHTS SHOWN AS "NEW OR
RELOCATED" ARE TO BE RELOCATED FROM A PREVIOUS LOCATION
AS SHOWN ON THE DEMOLITION PLAN. THE DESIGN INTENT IS LESS
THAN 50% OF THE LIGHTS ARE ACTUALLY BEING REPLACED WITH NEW
AND OVERALL WATTAGE IS STAYING THE SAME OR DECREASING.
LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS.
ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT
INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1,
CONTRACTOR MUST NOTIFY SDI.
5. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS; PROVIDE COMBO
UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A
ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE
LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF
INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED
OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED.
6. NEW DEVICES AND FACE PLATES TO MATCH EXISTING. WHERE
POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE
MULTI-SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON
PLAN.
7. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO
ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND
LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING
ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS
TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED
SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH
ALL APPLICABLE CODES.
8. PROVIDE SOUND BOOTS AT ALL PRIVATE OFFICES.
GENERAL NOTES
1. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL
APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL
MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND
FLEX DUCT PER NEW WALL LAYOUT. IF IN GOOD CONDITION, EXISTING
H.V.A.C. DIFFUSERS SALVAGED FROM DECONSTRUCTION MAY BE
SUBSTITUTED FOR NEW. NO NEW HARD DUCTWORK OR EQUIPMENT IS
BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY
APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT
ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE
INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES.
MECHANICAL NOTES
01/11/22