Loading...
HomeMy WebLinkAboutRCP100.2 - Reflected Ceiling Plan-South, South CollegeUP UP UP EL S N6 S NSNSNS NS N SNSNSNELNELNELNELNS N S N6 ELN ELNSN6SN6ELNS N S N S N SNS N S N SNSNS NS NSN SNS NS NELNL N L NL NL NL ELNSN3S N S NELN REFLECTED CEILING PLAN A122REFLECTED CEILING PLAN DESCRIPTIONDATE ISSUE 05.05.21 REVIEW SET 05.14.21 PERMIT SET 06.08.21 CONSTRUCTION SET REVISIONS DESCRIPTIONMARK DATE DB 06.08.21 AS REV 1 THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. PROJECT NUMBER DRAWN BYPROJ. MGR 450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comSOUTH COLLEGEPENN ON PKWY | 1ST FLOOR301 PENNSYLVANIA PKWY, INDIANAPOLIS, IN 46280AS/EHAS 2020.325 N 0 2' 4' 8' 16' PLAN NOTES CONTRACTOR TO CONSULT WITH LANDLORD TO CONFIRM IF EXISTING COOLING IS PRESENT; PROVIDE NEW AS REQUIRED + COORDINATE WITH TENANTS ON ALL REQUIREMENT. CONTROL LIGHTING IN THIS AREA WITH 3-WAY SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. PROVIDE POWER FOR AUTOMATIC RECESSED PROJECTOR SCREEN (BY TENANT) AT THIS LOCATION. COORDINATE WITH TENANT ON FINAL LOCATION OF SCREEN AND CONTROL SWITCH/PANEL. PROVIDE NEW CEILING GRID AND TILE TO MATCH AND ALIGN WITH EXISTING SUCH THAT NEW AND EXISTING CEILINGS APPEAR CONTINUOUS. AT AREAS OF NEW CEILING THAT ARE NOW CONTINUOUS WITH COMMON AREA, PROVIDE BUILDING STANDARD LIGHTING + DIFFUSERS AND ALL REQUIRED LIFE SAFETY ELEMENTS. ALL NEARBY CAN LIGHTING TO BE CONTROLLED BY THIS SWITCH. INSTALL CEILING PROJECTOR (BY TENANT) AT THIS LOCATION. CONFIRM FINAL LOCATION AND REQUIREMENTS WITH TENANT. CONTROL SOUTH WING SUITE CORRIDOR LIGHTING WITH 6-WAY SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. EXISTING BULKHEAD TO REMAIN AND BE PAINTED BRIGHT CEILING WHITE, FLAT FINISH. IN AREA TO BE EXPOSED TO DECK, REPLACE LOW PRESSURE SUPPLY BRANCH LINE DUCT AND WITH NEW RIGID SPIRAL DUCT AND ROUND SUPPLY DIFFUSERS AS REQUIRED. CLEAN AND PREPARE FOR DRYFALL PAINT (PT4). AS SPECIFIED, PAINT EXISTING EXPOSED CEILING DECK, EXPOSED DUCTWORK, SPRINKLER PIPING, JUNCTION BOXES, CONDUIT, STRUCTURAL BEAMS FIREPROOFING, ETC. IN ACCORDANCE WITH NFPA 13 6.3.8. NOTE: NOT ALL PLAN NOTES ARE USED ON EACH SHEET. LIGHT CIRCUIT LIGHT SWITCH, DIMMER LIGHT SWITCH, 3-WAY LIGHT SWITCH ND N N3 D 3 EXIT LIGHT FIXTURE UPLIGHT GROUP: PILKE P18 PENDANT, COLOR: WHITE STAINED #SF-P1805 RECESSED LIGHT FIXTURE, RELOCATED LIGHT FIXTURE, 2'x2', FLUORESCENT, LED LIGHT FIXTURE, 2'x4', FLUORESCENT, LED RELOCATED DIFFUSER, LAY-IN, 4"x4' RELOCATED DIFFUSER, LAY-IN, 2'x2' CEILING GRID, SUSPENDED, 2'x2' NIGHT LIGHT NEW OR RELOCATED EXISTING TO REMAIN AXIS LIGHTING: STENCIL PENDANT, COLOR: WHITE, LENGTHS VARY, BOTTOM OF FIXTURES MOUNTED AT 11'-6" AFF. COORDINATE EXACT SPECIFICATIONS AND REQUIREMENTS WITH ESL SPECTRUM: JENNIFER HALL 317.750.7221 jhall@esl-spectrum.com LIGHT FIXTURE, PENDANT EXIT LIGHT FIXTURE LIGHT CIRCUIT LIGHT SWITCH, DIMMER LIGHT SWITCH, 3-WAY LIGHT SWITCH CEILING GRID, SUSPENDED, 2'x2' DIFFUSER, LAY-IN, 4"x4' DIFFUSER, LAY-IN, 2'x2' GYPSUM BOARD CEILING LIGHT FIXTURE, 2'x2', FLUORESCENT, LED LIGHT FIXTURE, 2'x4', FLUORESCENT, LED LEGEND RECESSED LIGHT FIXTURE EMERGENCY LIGHT FIXTURE EMERGENCY LIGHT FIXTURE EXHAUST FAN, 2'x2' GYPSUM BOARD CEILING EXPOSED TO DECK 1 1 1ST FLOOR - S AREA NOT IN CONTRACT AREA OF WORK 1. REUSE EXISTING CEILING GRID AND TILE UNLESS OTHERWISE NOTED. EXISTING GRID IS 2x2 AT APPROXIMATELY 9'-11" A.F.F. EXACT CEILING HEIGHTS MAY VARY BETWEEN SUITES - COORDINATE WITH SDI AS REQUIRED. TILES ARE 2x2 ACOUSTICAL LAY IN TILES. REPAIR ANY DAMAGED GRID AND REPLACE ANY DAMAGED TILES WITH NEW TO MATCH EXISTING. 2. IF IN GOOD CONDITION, EXISTING CEILING TILES SALVAGED FROM DECONSTRUCTION CAN BE SUBSTITUTED FOR NEW. PROVIDE LIKE CEILING TILES IN INDIVIDUAL ROOMS WHERE POSSIBLE TO CREATE UNIFORM LOOK. 3. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 4. UNLESS NOTED OTHERWISE, THE LIGHTS SHOWN AS "NEW OR RELOCATED" ARE TO BE RELOCATED FROM A PREVIOUS LOCATION AS SHOWN ON THE DEMOLITION PLAN. THE DESIGN INTENT IS LESS THAN 50% OF THE LIGHTS ARE ACTUALLY BEING REPLACED WITH NEW AND OVERALL WATTAGE IS STAYING THE SAME OR DECREASING. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. 5. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS; PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED. 6. NEW DEVICES AND FACE PLATES TO MATCH EXISTING. WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTI-SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN. 7. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS.  ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. 8. PROVIDE SOUND BOOTS AT ALL PRIVATE OFFICES. GENERAL NOTES 1. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED.  ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. IF IN GOOD CONDITION, EXISTING H.V.A.C. DIFFUSERS SALVAGED FROM DECONSTRUCTION MAY BE SUBSTITUTED FOR NEW. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED;  MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. MECHANICAL NOTES 01/11/22