Loading...
HomeMy WebLinkAboutS100.1 - Structural Floor Plan-North, South CollegeWALL THICKNESS PRE-FINISHED ALUMINUM RECEIVER TRIM - FASTEN AT WINDOW SILL AND SET IN A CONTINUOUS BEAD OF CAULK AT WINDOW MULLION WHERE NEW WALLS MEET. TRIM COLOR TO MATCH BUILDING WINDOW MULLIONS. LINE OF EXISTING WINDOW SILL COVER BELOW CONTINUOUS BEAD OF ACOUSTICAL SEALANT TYPICAL WALL TYPE METAL STUD EXISTING WINDOW MULLION EQUAL UP U P UP NURSING LAB 146CONF 128 OPEN OFFICE 20 STATIONS 126 OFFICE 118 OFFICE 117 OFFICE 106 OFFICE 102 OFFICE 105 OFFICE 104 OFFICE 103 OFFICE 115 OFFICE 114 OFFICE 113 OFFICE 112 OFFICE 116 ENTRY 101 TESTING 109 COPY 107 CLASSROOM 139 CLASSROOM 138 STUDY 144 STAFF BREAK 132 STORAGE / IT 140 OFFICE 119 OFFICE 120 OFFICE 121 OFFICE 122 CONFERENCE 123 COMPUTER LAB 170 ENTRY 169 LIBRARY / RESOURCE LAB 168 STUDENT CENTER 141 FIRE-RATED FILES 137 OFFICE 111 OFFICE 110 TESTING 108 OFFICE 124 STUDY 145 STUDY 143 STUDY 142 OFFICE 130 OFFICE 136 OFFICE 135 OFFICE 134 OFFICE 131 OPEN OFFICE 3 STATIONS 133 ENTRY 127 RR 129 EXIT DISCHARGE 171 5'-5"3'-5" 4'-81 4"12'-5"10'-51 4 " 10'-4 3 4 " 10'-5 " 10'-5" 10'- 5"5'-11" 6'-7" 5'-6"CLEAR21'- 5 " 10'- 53 4 " 21'-5 " 12'-0" 5'-5"3'-0" 12'-1 3 4" 12'-1 34"9'-014"68°CLEAR4' -6 "9'-014"5'-5" 9'-5" 9'-5" 9'-5" 8'-13 4 "3'-5"7'-5" CL 7'-5"6"ALIGN HALL 172 8'-61 4" 2'-6" 5'-5" 5'-11"5'-6"CLEAR4'-21 2"CLE A R 5'-0" CLE A R CLOSET 125 11'-21 4"± 8'-6"8'-734"11 2 °FEFEFEFE FEFE10'-5"6'-0" CLEAR FE ARCHITECTURAL FLOOR PLAN A111ARCHITECTURAL PLANAREA NOT IN CONTRACT AREA OF WORK DESCRIPTIONDATE ISSUE 05.05.21 REVIEW SET 05.14.21 PERMIT SET 06.08.21 CONSTRUCTION SET REVISIONS DESCRIPTIONMARK DATE DB 06.08.21 AS REV 1 THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. PROJECT NUMBER DRAWN BYPROJ. MGR 450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comSOUTH COLLEGEPENN ON PKWY | 1ST FLOOR301 PENNSYLVANIA PKWY, INDIANAPOLIS, IN 46280AS/EHAS 2020.325 N 0 2' 4' 8' 16' 1ST FLOOR - N WALL DOOR AND FRAME (SEE DOOR SCHEDULE) NEW CONSTRUCTION EXISTING TO REMAIN WALL DOOR AND FRAME WINDOW / SIDELIGHTWINDOW / SIDELIGHT ARCHITECTURAL LEGEND PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL WALL TO DECK WITH INSULATION 358" METAL STUDS AT 16" O.C.; ONE LAYER OF 58" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF DECK; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING W1 W2 WALL WITH INSULATION 358 " METAL STUDS AT 16" O.C.; ONE LAYER OF 58" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING W3 WALL TYPES W1 NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. GENERAL NOTES TWO-HOUR WALL TO DECK 358" METAL STUDS AT 16" O.C. (UTILIZE HEAVY GAUGE STUD AS REQUIRED), TWO LAYERS OF 58" FIRE-SHIELD (OR SIMILAR) GYPSUM BOARD EACH SIDE; HORIZONTAL AND VERTICAL JOINTS STAGGERED; EXTEND WALL TO UNDERSIDE OF DECK; ALL PENETRATIONS TO BE FIRE STOPPED AND SMOKE DAMPERED AS REQUIRED NOTE: NOT ALL PLAN NOTES ARE USED ON EACH SHEET. 1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. 2. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. 3. ENSURE ALL EXISTING WALLS MATCH WALL TYPE W1; MODIFY AS REQUIRED TO MATCH. ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. PROVIDE PLYWOOD PHONE BOARD, 4'x8'x34", PAINTED WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY LOCATION WITH TENANT PRIOR TO INSTALLATION. NEW FIRE EXTINGUISHER AND SEMI-RECESSED CABINET TO BE PROVIDED AND INSTALLED BY CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10. REUSE EXISTING FIRE EXTINGUISHERS + CABINETS WHERE POSSIBLE. PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WITH TENANT. CONFIRM THAT EXISTING WALL MATCHES WALL TYPE "W2". IF NOT, ALTER EXISTING WALL AS REQUIRED TO MATCH "W2". PROVIDE (5) 15"D MELAMINE SHELVES ON HEAVY DUTY K/V BRACKETS AND STANDARDS AS SHOWN; VERIFY LENGTH(S) IN FIELD. X-RAY EQUIPMENT LOCATED IN THIS AREA. CONTRACTOR TO OBTAIN A COPY OF AND ADHERE TO THE PHYSICIST GUIDELINES. CONTRACTOR TO OBTAIN SITE SPECIFIC DRAWINGS OF X-RAY EQUIPMENT AND PROVIDE POWER AND EQUIPMENT STRUCTURAL SUPPORT AND TRENCHING AS REQUIRED (CONSULT STRUCTURAL ENGINEER AS REQUIRED). PROVIDE LEAD LINED WALL BOARD (16" LEAD) FROM FLOOR TO 7'-0" AFF. PROVIDE WATER DRAINS, GASES, AND VENTILATION AT (6) CHEM LAB WORKSTATIONS AS REQUIRED. CONFIRM EXACT LOCATIONS AND REQUIREMENTS WITH TENANT'S EQUIPMENT VENDOR. ALL TO BE RUN FROM OVERHEAD/THROUGH CEILING. PROVIDE (5) 15"D CHEMSURF PLASTIC LAMINATE (PL8) SHELVES ON HEAVY DUTY K/V BRACKETS AND STANDARDS AS SHOWN; VERIFY LENGTH(S) IN FIELD. CONTRACTOR TO MOUNT AMICO HEADWALL UNIT (PROVIDED BY TENANT) AT 60" AFF. PROVIDE BLOCKING IN WALL. A COMPRESSOR WILL BE THE SOURCE FOR SIMULATED OXYGEN, AIR AND VACUUM. ENSURE EXISTING PARTITION SKYFOLD WALL IS IN GOOD WORKING ORDER. PROVIDE ACOUSTIC RUBBER MEMBRANE BEHIND DRYWALL AT THIS LOCATION. ALTER EXISTING WALL TO MATCH WALL TYPE "W3" AS REQUIRED. PROVIDE 18" DEEP QUARTZ (QZ_) COUNTERTOP AT 42" AFF. SUPPORT COUNTER AS REQUIRED WITH RAKKS EH-1818-FM BRACKET ATTACHED TO METAL STUDS WITH WOOD BLOCKING AND DRYWALL INSTALLED OVER VERTICAL SUPPORT. CASEWORK CONTRACTOR TO INSTALL BRACKETS AS NEEDED PRIOR TO INSTALLATION OF DRYWALL. CONFIRM LENGTH(S) AND ANGLES IN FIELD. CONTRACTOR TO MOUNT WELCH ALLYN UNIT (PROVIDED BY TENANT) AND PROVIDE BLOCKING IN WALL AT THIS LOCATION. CONTRACTOR TO MOUNT MONITOR (PROVIDED BY TENANT). CONFIRM WALL OR CEILING MOUNT WITH TENANT AND PROVIDE BLOCKING AS REQUIRED. WHERE CEILING IS TO BE EXPOSED, CONFIRM DRYWALL EXTENDS TO DECK AND ADD WHERE REQUIRED. PROVIDE NEW RECEPTION DESK AT THIS LOCATION WITH $20,000 ALLOWANCE. MATERIALS MAY INCLUDE QUARTZ, WOOD VENEER, PLASTIC LAMINATE, METAL, ETC. FINAL DESIGN AND DETAILS TBD. PROVIDE 74"W X 48"H ONE-WAY GLASS WINDOW AT THIS LOCATION. INTENT IS FOR CONTROL ROOM TO BE CONCEALED FROM SIM LABS. INSTALL SUCH THAT BOTTOM OF WINDOW FRAME IS AT 38" AFF; COORDINATE INSTALLATION HEIGHT WITH CASEWORK BELOW. ALL WALLS FOR THIS ROOM TO BE WALL TYPE "W3". PROVIDE LEVEL 5 DRYWALL FINISH FOR DRYERASE WALLCOVERING AT THIS LOCATION; REFER TO FINISH PLAN. AT THIS LOCATION, PROVIDE 3'-0"X3'-0" LEAD LINED WINDOW AS SHOWN AT 40" AFF. PROVIDE 24"D X 72"W PLASTIC LAMINATE (PL_) COUNTERTOP BELOW WITH CONCEALED SUPPORT BRACKETS. _______________________________________________________________ PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE AND VENT PIPING FOR SINKS. REFER TO LANDLORD FOR SOURCE OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING. CONTRACTOR TO INSTALL AUTOMATIC SHUTOFF VALVES AS REQUIRED. PROVIDE WATER LINE FOR COFFEE AND REFRIGERATOR. CONFIRM LOCATION WITH TENANT. EMERGENCY SHOWER AND EYE WASH STATION AT THIS LOCATION. CONTRACTOR TO PROVIDE FLOOR DRAIN WITH WATER BOUNDARY AND ALL REQUIRED PLUMBING; PROVIDE CUT SHEET FOR APPROVAL. SINK-MOUNTED 90° "SWING ON" EYE WASH STATION. CONTRACTOR TO PROVIDE ALL PLUMBING AS REQUIRED; PROVIDE CUT SHEET FOR APPROVAL. PROVIDE COLD WATER SUPPLY AND WATER LINES AS REQUIRED FOR NEW TOILET. PLAN NOTES NOT TO SCALE WALL AT MULLION DETAIL A111 1 W2 W2 W2 W2 W2 W2 W3 W3 W3 W3 W2 W3 W3 W3 W2 A212 4 A212 2 A212 1 W3 W3 W2 W2 A212 3 W2 W2 A141 3 W2 W2 W2 W2 W2 W2 W2 W2 01/11/22