HomeMy WebLinkAboutS100.1 - Structural Floor Plan-North, South CollegeWALL
THICKNESS
PRE-FINISHED ALUMINUM
RECEIVER TRIM - FASTEN AT
WINDOW SILL AND SET IN A
CONTINUOUS BEAD OF
CAULK AT WINDOW MULLION
WHERE NEW WALLS MEET.
TRIM COLOR TO MATCH
BUILDING WINDOW
MULLIONS.
LINE OF EXISTING WINDOW
SILL COVER BELOW
CONTINUOUS BEAD OF
ACOUSTICAL SEALANT
TYPICAL WALL TYPE
METAL STUD
EXISTING WINDOW
MULLION
EQUAL
UP
U
P
UP
NURSING
LAB
146CONF
128
OPEN OFFICE
20 STATIONS
126
OFFICE
118
OFFICE
117
OFFICE
106
OFFICE
102
OFFICE
105
OFFICE
104
OFFICE
103
OFFICE
115
OFFICE
114
OFFICE
113
OFFICE
112
OFFICE
116
ENTRY
101
TESTING
109
COPY
107
CLASSROOM
139
CLASSROOM
138
STUDY
144
STAFF BREAK
132
STORAGE / IT
140
OFFICE
119
OFFICE
120
OFFICE
121
OFFICE
122
CONFERENCE
123
COMPUTER LAB
170
ENTRY
169
LIBRARY /
RESOURCE LAB
168
STUDENT CENTER
141
FIRE-RATED
FILES
137
OFFICE
111 OFFICE
110
TESTING
108
OFFICE
124
STUDY
145
STUDY
143
STUDY
142
OFFICE
130
OFFICE
136
OFFICE
135
OFFICE
134
OFFICE
131
OPEN OFFICE
3 STATIONS
133
ENTRY
127
RR
129
EXIT
DISCHARGE
171
5'-5"3'-5"
4'-81
4"12'-5"10'-51
4 "
10'-4 3
4 "
10'-5
"
10'-5"
10'-
5"5'-11" 6'-7" 5'-6"CLEAR21'-
5
"
10'- 53
4 "
21'-5
"
12'-0"
5'-5"3'-0" 12'-1
3
4"
12'-1
34"9'-014"68°CLEAR4'
-6
"9'-014"5'-5"
9'-5"
9'-5"
9'-5"
8'-13
4 "3'-5"7'-5"
CL
7'-5"6"ALIGN
HALL
172
8'-61
4"
2'-6"
5'-5" 5'-11"5'-6"CLEAR4'-21
2"CLE
A
R
5'-0"
CLE
A
R
CLOSET
125
11'-21
4"±
8'-6"8'-734"11
2
°FEFEFEFE
FEFE10'-5"6'-0"
CLEAR
FE
ARCHITECTURAL
FLOOR PLAN
A111ARCHITECTURAL PLANAREA NOT IN CONTRACT
AREA OF WORK
DESCRIPTIONDATE
ISSUE
05.05.21 REVIEW SET
05.14.21 PERMIT SET
06.08.21 CONSTRUCTION SET
REVISIONS
DESCRIPTIONMARK DATE DB
06.08.21 AS REV 1
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
PROJECT NUMBER
DRAWN BYPROJ. MGR 450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comSOUTH COLLEGEPENN ON PKWY | 1ST FLOOR301 PENNSYLVANIA PKWY, INDIANAPOLIS, IN 46280AS/EHAS
2020.325
N
0 2' 4' 8' 16'
1ST FLOOR - N
WALL
DOOR AND FRAME
(SEE DOOR SCHEDULE)
NEW CONSTRUCTION EXISTING TO REMAIN
WALL
DOOR AND FRAME
WINDOW / SIDELIGHTWINDOW / SIDELIGHT
ARCHITECTURAL LEGEND
PARTIAL HEIGHT WALL
PARTIAL HEIGHT WALL
WALL TO DECK WITH INSULATION
358" METAL STUDS AT 16" O.C.;
ONE LAYER OF 58" TYPE "X" GYPSUM BOARD EACH
SIDE;
EXTEND WALL TO UNDERSIDE OF DECK;
FIBERGLASS SOUND BATT INSULATION INSIDE WALL
AND 2'-0" EACH SIDE OF WALL ABOVE CEILING
W1
W2
WALL WITH INSULATION
358 " METAL STUDS AT 16" O.C.;
ONE LAYER OF 58" TYPE "X" GYPSUM BOARD EACH
SIDE;
EXTEND WALL TO UNDERSIDE OF CEILING;
FIBERGLASS SOUND BATT INSULATION INSIDE WALL
AND 2'-0" EACH SIDE OF WALL ABOVE CEILING
W3
WALL TYPES
W1
NOTE:
ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL.
ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED. PROVIDE MOISTURE
RESISTANT / GREEN BOARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS.
NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT.
REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS.
GENERAL NOTES
TWO-HOUR WALL TO DECK
358" METAL STUDS AT 16" O.C. (UTILIZE HEAVY
GAUGE STUD AS REQUIRED), TWO LAYERS OF 58"
FIRE-SHIELD (OR SIMILAR) GYPSUM BOARD EACH
SIDE; HORIZONTAL AND VERTICAL JOINTS
STAGGERED; EXTEND WALL TO UNDERSIDE OF DECK;
ALL PENETRATIONS TO BE FIRE STOPPED AND SMOKE
DAMPERED AS REQUIRED
NOTE: NOT ALL PLAN NOTES ARE USED ON EACH SHEET.
1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT.
2. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR
WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL
FINISH. REFER TO MANUFACTURER RECOMMENDATIONS.
3. ENSURE ALL EXISTING WALLS MATCH WALL TYPE W1; MODIFY AS
REQUIRED TO MATCH.
ALIGN FINISHED WALL SURFACES. PROVIDE SAME
THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR
WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS.
PROVIDE PLYWOOD PHONE BOARD, 4'x8'x34", PAINTED WITH FIRE
RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY
LOCATION WITH TENANT PRIOR TO INSTALLATION.
NEW FIRE EXTINGUISHER AND SEMI-RECESSED CABINET TO BE
PROVIDED AND INSTALLED BY CONTRACTOR. ALL FIRE
EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10.
REUSE EXISTING FIRE EXTINGUISHERS + CABINETS WHERE POSSIBLE.
PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR
TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT
LOCATION WITH TENANT.
CONFIRM THAT EXISTING WALL MATCHES WALL TYPE "W2". IF NOT,
ALTER EXISTING WALL AS REQUIRED TO MATCH "W2".
PROVIDE (5) 15"D MELAMINE SHELVES ON HEAVY DUTY K/V
BRACKETS AND STANDARDS AS SHOWN; VERIFY LENGTH(S) IN
FIELD.
X-RAY EQUIPMENT LOCATED IN THIS AREA. CONTRACTOR TO
OBTAIN A COPY OF AND ADHERE TO THE PHYSICIST GUIDELINES.
CONTRACTOR TO OBTAIN SITE SPECIFIC DRAWINGS OF X-RAY
EQUIPMENT AND PROVIDE POWER AND EQUIPMENT STRUCTURAL
SUPPORT AND TRENCHING AS REQUIRED (CONSULT STRUCTURAL
ENGINEER AS REQUIRED).
PROVIDE LEAD LINED WALL BOARD (16" LEAD) FROM FLOOR TO
7'-0" AFF.
PROVIDE WATER DRAINS, GASES, AND VENTILATION AT (6) CHEM
LAB WORKSTATIONS AS REQUIRED. CONFIRM EXACT LOCATIONS
AND REQUIREMENTS WITH TENANT'S EQUIPMENT VENDOR. ALL TO
BE RUN FROM OVERHEAD/THROUGH CEILING.
PROVIDE (5) 15"D CHEMSURF PLASTIC LAMINATE (PL8) SHELVES
ON HEAVY DUTY K/V BRACKETS AND STANDARDS AS SHOWN;
VERIFY LENGTH(S) IN FIELD.
CONTRACTOR TO MOUNT AMICO HEADWALL UNIT (PROVIDED BY
TENANT) AT 60" AFF. PROVIDE BLOCKING IN WALL. A
COMPRESSOR WILL BE THE SOURCE FOR SIMULATED OXYGEN, AIR
AND VACUUM.
ENSURE EXISTING PARTITION SKYFOLD WALL IS IN GOOD
WORKING ORDER.
PROVIDE ACOUSTIC RUBBER MEMBRANE BEHIND DRYWALL AT
THIS LOCATION.
ALTER EXISTING WALL TO MATCH WALL TYPE "W3" AS REQUIRED.
PROVIDE 18" DEEP QUARTZ (QZ_) COUNTERTOP AT 42" AFF.
SUPPORT COUNTER AS REQUIRED WITH RAKKS EH-1818-FM
BRACKET ATTACHED TO METAL STUDS WITH WOOD BLOCKING
AND DRYWALL INSTALLED OVER VERTICAL SUPPORT. CASEWORK
CONTRACTOR TO INSTALL BRACKETS AS NEEDED PRIOR TO
INSTALLATION OF DRYWALL. CONFIRM LENGTH(S) AND ANGLES IN
FIELD.
CONTRACTOR TO MOUNT WELCH ALLYN UNIT (PROVIDED BY
TENANT) AND PROVIDE BLOCKING IN WALL AT THIS LOCATION.
CONTRACTOR TO MOUNT MONITOR (PROVIDED BY TENANT).
CONFIRM WALL OR CEILING MOUNT WITH TENANT AND PROVIDE
BLOCKING AS REQUIRED.
WHERE CEILING IS TO BE EXPOSED, CONFIRM DRYWALL EXTENDS
TO DECK AND ADD WHERE REQUIRED.
PROVIDE NEW RECEPTION DESK AT THIS LOCATION WITH $20,000
ALLOWANCE. MATERIALS MAY INCLUDE QUARTZ, WOOD VENEER,
PLASTIC LAMINATE, METAL, ETC. FINAL DESIGN AND DETAILS TBD.
PROVIDE 74"W X 48"H ONE-WAY GLASS WINDOW AT THIS
LOCATION. INTENT IS FOR CONTROL ROOM TO BE CONCEALED
FROM SIM LABS. INSTALL SUCH THAT BOTTOM OF WINDOW FRAME
IS AT 38" AFF; COORDINATE INSTALLATION HEIGHT WITH
CASEWORK BELOW.
ALL WALLS FOR THIS ROOM TO BE WALL TYPE "W3".
PROVIDE LEVEL 5 DRYWALL FINISH FOR DRYERASE
WALLCOVERING AT THIS LOCATION; REFER TO FINISH PLAN.
AT THIS LOCATION, PROVIDE 3'-0"X3'-0" LEAD LINED WINDOW AS
SHOWN AT 40" AFF. PROVIDE 24"D X 72"W PLASTIC LAMINATE (PL_)
COUNTERTOP BELOW WITH CONCEALED SUPPORT BRACKETS.
_______________________________________________________________
PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE
AND VENT PIPING FOR SINKS.
REFER TO LANDLORD FOR SOURCE OF HOT WATER AND
LOCATION ALLOWED IN THIS BUILDING. CONTRACTOR TO INSTALL
AUTOMATIC SHUTOFF VALVES AS REQUIRED.
PROVIDE WATER LINE FOR COFFEE AND REFRIGERATOR. CONFIRM
LOCATION WITH TENANT.
EMERGENCY SHOWER AND EYE WASH STATION AT THIS
LOCATION. CONTRACTOR TO PROVIDE FLOOR DRAIN WITH
WATER BOUNDARY AND ALL REQUIRED PLUMBING; PROVIDE CUT
SHEET FOR APPROVAL.
SINK-MOUNTED 90° "SWING ON" EYE WASH STATION.
CONTRACTOR TO PROVIDE ALL PLUMBING AS REQUIRED;
PROVIDE CUT SHEET FOR APPROVAL.
PROVIDE COLD WATER SUPPLY AND WATER LINES AS REQUIRED
FOR NEW TOILET.
PLAN NOTES
NOT TO SCALE
WALL AT MULLION DETAIL
A111
1
W2
W2
W2
W2
W2
W2
W3
W3
W3
W3
W2
W3 W3
W3
W2
A212
4
A212
2
A212
1
W3
W3
W2
W2
A212
3
W2
W2
A141
3
W2
W2
W2
W2
W2
W2
W2
W2
01/11/22