HomeMy WebLinkAboutE100.2 - Electrical Plan-South, South CollegeUP UP UPCHEM LAB 164 STORAGE 163 STG 165 A+P LAB 162 NURSING LAB 146 CLASSROOM 167 STG 147 STG 149 EXAM 150 EXAM 153 ASSESSMENT LAB 148 RADIOLOGY LAB 166 ULTRASOUND LAB 159 STUDY 144 IT STG 160 SERVER 161 CLASSROOM 154 EXAM 152 EXAM 151 COMPUTER LAB 170 ENTRY 169 LIBRARY / RESOURCE LAB 168 STUDY 155 STUDY 145 SIM LAB 156 SIM LAB 158 CONTROL ROOM 157 +60"+48"+48"+60"+48"+48"+60"+48"+48"+60"+48"+48"+48"+48"+48"+42"GFCI+24" +42" +42" GFCI +42" +42"GFCI +42"GFCI +42"GFCI GFCI +42" GFCI +42"+42" +42" +42" GFCI +4 2" +42 " +42" +42" GFCI GF CI GFCI GFCI GFCI GFCI +42" +42" GFCI +42" +42"GFCI +42"GFCI +42"GFCI +44" +44"DEDGFCI +TBD +TBD GFCI GF CI +42" +42" +42" +42 "+42"+42" +42" +42" +44" +44"REFRIGBYTEN ANTDED ELECTRICAL PLAN E112ELECTRICAL PLAN DESCRIPTIONDATE ISSUE 05.05.21 REVIEW SET 05.14.21 PERMIT SET 06.08.21 CONSTRUCTION SET REVISIONS DESCRIPTIONMARK DATE DB 06.08.21 AS REV 1 THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. PROJECT NUMBER DRAWN BYPROJ. MGR 450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comSOUTH COLLEGEPENN ON PKWY | 1ST FLOOR301 PENNSYLVANIA PKWY, INDIANAPOLIS, IN 46280AS/EHAS 2020.325 N 0 2' 4' 8' 16' LEGEND DED POWER OUTLET, DUPLEX NEW CONSTRUCTION EXISTING TO REMAIN POWER OUTLET, QUADRUPLEX JUNCTION BOX POWER OUTLET, DUPLEX POWER OUTLET, QUADRUPLEX JUNCTION BOX BOX, BLANK COVER PLATE BOX, BLANK COVER PLATE FLOOR BOX WITH POWER AND DATA, FLUSH MOUNTED FLOOR BOX WITH JUNCTION BOX AND DATA, FLUSH MOUNTED FLOOR BOX WITH POWER AND DATA, FLUSH MOUNTED FLOOR BOX WITH JUNCTION BOX AND DATA, FLUSH MOUNTED DEDICATED CIRCUIT DATA/COMMUNICATION OUTLET (PROVIDE BOX AND PULL STRING ONLY) DATA/COMMUNICATION OUTLET GFCI GROUND FAULT CIRCUIT INTERRUPT OUTLET HEIGHT OF ELECTRICAL OR DATA DEVICE CEILING MOUNTED JUNCTION BOX CEILING MOUNTED JUNCTION BOX J B J +42" PROVIDE POWER AS REQUIRED AT DOOR FOR CARD READER (CARD READER BY TENANT). COORDINATE WITH TENANT'S SECURITY CONTRACTOR. SEE DOOR SCHEDULE FOR MORE DETAILS. COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE DEDICATED RECEPTACLE AS REQUIRED. PROVIDE JUNCTION BOX AND DATA FOR TENANT'S FURNITURE SYSTEM. COORDINATE EXACT LOCATION WITH TENANT'S FURNITURE VENDOR. PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET INTO CABINET/ WALL FOR TENANT'S MICROWAVE, CENTERED AT HEIGHT NOTED ON PLANS. PROVIDE JUNCTION BOX ABOVE CEILING FOR TENANT PROVIDED CEILING MOUNTED PROJECTOR. COORDINATE WITH TENANT ON EXACT REQUIREMENTS AND ALL AV CONNECTION POINTS. COORDINATE EXACT LOCATIONS AND REQUIREMENTS FOR ALL POWER/DATA/AV CONNECTIONS WITH TENANT'S EQUIPMENT VENDOR. PROVIDE ABOVE COUNTER POWER AT THESE LOCATIONS; COORDINATE FINAL HEIGHTS WITH COUNTERTOP. NO NEW ELECTRICAL WORK IN THIS AREA. PROVIDE FLUSH MOUNT FLOOR CORE WITH POKE THRU DEVICE FOR ELECTRICAL AND DATA. COORDINATE WITH TENANTS FURNITURE VENDOR ON EXACT LOCATION. PROVIDE POKE THRU DEVICE SUBMITTAL TO TENANT FOR APPROVAL PRIOR TO ORDERING. CONFIRM POWER FOR EXISTING CARD READER SYSTEM IS SUFFICIENT FOR TENANT'S NEW SYSTEM (CARD READY BY TENANT). PROVIDE NEW AS REQUIRED; COORDINATE WITH TENANT' SECURITY CONTRACTOR. PROVIDE POWER AND DATA AT HEIGHT NOTED ON PLAN FOR TENANT'S WALL MOUNTED TELEVISION. COORDINATE EXACT LOCATION WITH TENANT. PLAN NOTES 1. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS. 2. ALL OUTLETS ARE TO INSTALLED 18" MIN. A.F.F. TO THE CENTER OF THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALL NEW DEVICES AND FACE PLATES TO MATCH EXISTING. 3. REFER TO DOOR SCHEDULE AND COORDINATE WITH TENANT/OWNER REGARDING POWER LOCATIONS TO ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI. 4. CONTRACTOR TO PROVIDE GFCI OUTLET FOR WATER HEATER AND AUTOMATIC SHUTOFF VALVES AS REQUIRED. 5. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. 6. ALL WIRING IN PATIENT CARE AREAS (I.E. SELF CARE UNIT AREAS, TREATMENT ROOMS, ETC.) SHALL COMPLY WITH NEC ARTICLE 517-13. ALL RECEPTACLES SHALL BE HOSPITAL GRADE TYPE RECEPTACLES. 7. ALL RECEPTACLES IN TREATMENT/EXAM AREAS SHALL BE GROUNDED PER NFPA 70, (NATIONAL ELECTRIC CODE, 2017) SECTION 517-13. 8. ALL MEDICAL AND X-RAY EQUIPMENT SHALL BE INSTALLED BY SUPPLIER AND CONNECTED BY ELECTRICAL CONTRACTOR. GENERAL CONTRACTOR SHALL COORDINATE INSTALLATION AND EXACT POWER REQUIREMENTS WITH MEDICAL EQUIPMENT MANUFACTURER PRIOR TO INSTALLATION. GENERAL NOTES NOTE: NOT ALL PLAN NOTES ARE USED ON EACH SHEET. J TENANT'S DATA VENDOR TO PROVIDE WIRELESS ACCESS POINT IN CEILING AT THIS LOCATION. COORDINATE ALL FINAL REQUIREMENTS WITH VENDOR AND TENANT. TENANT'S DATA/AV VENDOR TO PROVIDE CAMERA AT THIS LOCATION. COORDINATE ALL FINAL REQUIREMENTS WITH VENDOR AND TENANT. PROVIDE CONDUIT CONNECTION BETWEEN SERVER 161 AND STORAGE/IT 140 FOR IT CABLING. COORDINATE EXACT REQUIREMENTS WITH TENANT. PROVIDE REQUIRED POWER/DATA FOR TENANT'S XRAY EQUIPMENT AT THIS LOCATION. 1ST FLOOR - S AREA NOT IN CONTRACT AREA OF WORK 01/11/22