Loading...
HomeMy WebLinkAboutVWC CONV STORE3 A1.2 10-14-2021I I IREVISIONS:DRAWING COMPLETION DATE:4820 Buttonwood CrescentARCHITECT AIAGORDON CLARKIndianapolis, Indiana 46228Phone: 317 255-2546317 252-5573Fax: GClark4820@aol.comCONVENIENCE STORE / FOOD MARTVILLAGE OF WEST CLAYCARMEL, INDIANASOUTHWEST CORNER OFHARLESTON STREET AND TOWNE ROADOCTOBER 14, 2021 FOR PERMITTING AND CONSTRUCTIONSCALE: 1/4" = 1'-0" FOUNDATION PLAN CONCRETE REQUIREMENTS AND SPECIFICATIONS: IT IS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO FOLLOW ALL APPLICABLE SAFETY CODES AND REGULATIONS DURING ALL PHASES OF CONSTRUCTION. SHOULD ANY OF THE DETAILED INSTRUCTIONS SHOWN ON THE PLANS CONFLICT WITH THESE STRUCTURAL NOTES, THE SPECIFICATIONS, OR WITH EACH OTHER, THE STRICTEST PROVISIONS SHALL GOVERN. GOVERNING CODES: INTERNATIONAL BUILDING CODE, 2008, WITH CURRENT INDIANA AMENDMENTS. FOUNDATIONS: NOTIFY THE ARCHITECT AS SOON AS POSSIBLE OF ANY UNUSUAL SOIL CONDITIONS, SUCH AS UNEXPECTED SPRING OR SEEPAGE WATER, OR SOIL OF QUESTIONABLE BEARING CAPACITY. ALL FOOTINGS SHALL BEAR ON FIRM UNDISTURBED SOIL OR ENGINEERED FILL WITH AN ALLOWABLE BEARING CAPACITY OF 2,000 POUNDS PER SQUARE FOOT. PERIMETER FOOTINGS SHALL BEAR A MINIMUM OF 3'-0" BELOW EXTERIOR GRADE. STEP FOOTINGS AS REQUIRED. WHERE UNDERGROUND UTILITIES ENTER OR EXIT THE BUILDING, STEP TOPS OF ALL FOOTINGS BELOW UTILITY INVERT ELEVATIONS. DESIGN NET SOIL PRESSURES SPREAD FOOTINGS: CONTINUOUS FOOTERS 2,000 PSI 1,500 PSI. BACKFILL AND FILL MATERIALS: PROVIDE SATISFACTORY SOIL MATERIALS FOR BACKFILL AND FILL, FREE OF CLAY, DEBRIS, WASTE, FROZEN MATERIALS, VEGETABLE AND OTHER DELETERIOUS MATTER. REINFORCED CONCRETE: ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH ACI 318-95, "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE". SPECIFICATIONS: IN GENERAL, COMPLY WITH ACI 301-96, "STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE". PLACEMENT AND CURING OF CONCRETE SHALL CONFORM TO ACI 305 "HOT WEATHER CONCRETING" AND ACI 306 "COLD WEATHER CONCRETING". ALL REINFORCING DETAILS SHALL CONFORM TO ACI 315-86, "MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES" UNLESS DETAILED OTHERWISE ON THE STRUCTURAL DRAWINGS. ALL DEFORMED REINFORCING BARS: ASTM A615, GRADE 60 ALL WELDED WIRE FABRIC:ASTM A185, DELIVERED IN FLAT SHEETS REINFORCING SUPPLIER SHALL PROVIDE ALL BAR ACCESSORIES, CHAIRS, AND SUPPORTS NECESSARY TO SECURE STEEL IN ACCORDANCE WITH "ACT CODE OF STANDARD PRACTICE". WHERE ANY STEPS IN FALL FOOTING ELEVATIONS OCCUR, PROVIDE MAXIMUM STEP OF ONE VERTICAL TO TWO HORIZONTAL. CONCRETE COVER: UNLESS OTHERWISE NOTED, DETAIL REINFORCING TO PROVIDE MINIMUM COVER AS FOLLOWS: CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH:3 INCHES CONCRETE EXPOSED TO EARTH OR WEATHER, #5 RE-BARS OR SMALLER: 1/2 INCHES ALL OTHER:2 INCHES 1 CONCRETE CONTRACTOR SHALL VERIFY SOIL BEARING PRIOR TO CONCRETE PLACEMENT. REPORT DEVIATIONS TO GENERAL CONTRACTOR AND ARCHITECT. CONCRETE IN THE FOLLOWING AREAS SHALL CONSIST OF NATURAL SAND FINE AGGREGATE AND NORMAL WEIGHT COARSE AGGREGATES CONFORMING TO ASTM C33, TYPE 1 PORTLAND CEMENT CONFORMING TO ASTM C150, AND SHALL HAVE THE FOLLOWING COMPRESSIVE STRENGTH AT 28 DAYS: FOOTINGS AND PADS: SLABS-ON-GRADE AND PIERS: 3,000 PSI 4,000 PSI RETAINING WALLS, CURBS, SIDEWALKS, AND SLABS EXPOSED TO DE- ICERS. 4,000 PSI (6% + 1% ENTRAINED AIR BY VOLUME) NO PART OF THE STRUCTURE SHALL BE PLACED ON FROZEN OR WET SOIL. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING THE FOUNDATION AND SOIL WITHIN THE BUILDING AREA FROM FREEZING DURING WINTER CONSTRUCTION. FOOTINGS AND PIERS: DOWELS IN FOOTINGS SHALL MATCH VERTICAL PIER REINFORCING. PROVIDE CORNER BARS AT FOOTING CORNERS TO MATCH HORIZONTAL REINFORCING. MINIMUM LENGTHS OF EACH LEG TO BE 45 BAR DIAMETERS. BACKFILL AGAINST BOTH SIDES OF WALLS EQUALLY UNTIL THE LOWER ELEVATION IS ATTAINED. BRACE ALL FOUNDATION WALLS BEFORE BACKFILLING AND COMPACTING. PROVIDE LEAN CONCRETE (CLASS IV) UNDER FOUNDATIONS FOR ACCIDENTAL OVER-EXCAVATION, SOFT SPOTS, AND TRENCHES. BUILT-IN WORK: INSTALL ALL ANCHORS, INSERTS, NOSINGS, REGLETS AND LIKE ITEMS FURNISHED BY OTHER TRADES FOR INSTALLATION IN CONCRETE WORK. ALL BUILT-IN ITEMS SHALL BE IN PROPER LOCATION AND SHALL BE SO MAINTAINED DURING THE PERFORMANCE OF CONCRETE WORK. SLEEVES, CONDUITS, PIPES AND LIKE ITEMS PASSING THROUGH FLOORS, WALLS, OR BEAMS SHALL BE OF SUCH SIZE OR IN SUCH LOCATION AS NOT TO IMPAIR UNDULY THE STRENGTH OF THE CONSTRUCTION. VAPOR BARRIER PLACEMENT: USE A CONCRETE MIXTURE WITH AN ADEQUATE CEMENT FACTOR - MINIMUM OF 5 1/2 BAGS PER CUBIC YARD. USE A SMALL AMOUNT OF AIR-ENTRAINMENT IN THE MIXTURE TO REDUCE BLEEDING - ABOUT 3% TO 5% AIR. EXTERIOR CONCRETE SHALL HAVE 5 1/2% AIR. PLACE CONCRETE AT LOWEST PRACTICAL SLUMP. A WATER-REDUCING ADMIXTURE MAY BE USED TO LOWER THE MIX WATER CONTENT, IF USED STRICTLY ACCORDING TO WRITTEN MANUFACTURER'S INSTRUCTIONS. PERIMETER INSULATION: A TOTAL OF FOUR FEET WIDTH OF PERIMETER INSULATION SHALL BE PUT IN PLACE. THIS CAN BE A COMBINATION OF HORIZONTAL AND VERTICAL RIGID INSULATION, AS SHOWN ON DRAWINGS. 4'-0" x 4'-0" x 1'-0" CONCRETE FOOTER PAD #5 REBARS 12" O.C. EACH WAY 24" x 24" CONCRETE COLUMN PIER 2'-0"8'-8"2'-0"9" 87'-4"50'-8"40'-11"1'-5"9"1'-5"29'-5" 27'-8"1'-5"9"2'-0"8'-8"2'-0"9"1'-5"42'-8"8"1'-0"4"2'-5"2'-11"8"8"4'-0"1'-4"7'-4"4" THICK CONCRETE FLOOR SEE SPECIFICATIONS COOLER FOOTPRINT SEE SPECIAL FLOOR DETAILS SEE SPECIAL FLOOR DETAILS FREEZER FOOTPRINT 1 A3.1 1 1 A3.1 1 A3.1 1 1 A3.2 A3.2 A3.3 A3.3 A3.4 1 1 A3.5 1 A3.5 1 1 A3.4 1 A3.4 A3.4 A3.4 2 2 A1.2