HomeMy WebLinkAboutVWC CONV STORE4 A1.3 10-14-2021I
I
IREVISIONS:DRAWING COMPLETION DATE:4820 Buttonwood CrescentARCHITECT AIAGORDON CLARKIndianapolis, Indiana 46228Phone: 317 255-2546317 252-5573Fax: GClark4820@aol.comCONVENIENCE STORE / FOOD MARTVILLAGE OF WEST CLAYCARMEL, INDIANASOUTHWEST CORNER OFHARLESTON STREET AND TOWNE ROADOCTOBER 14, 2021
FOR PERMITTING AND CONSTRUCTIONACOUSTICAL CEILINGS:
1. PROVIDE ALL ACOUSTICAL CEILINGS COMPLETE WITH
SUSPENSION SYSTEM AND RELATED ACCESSORIES AS SHOWN
ON THE DRAWINGS AND SPECIFIED HEREIN.
2. STORE AND HANDLE TO PREVENT SOILING, DAMAGE OR
WETTING.
3. INSTALL ALL ACOUSTIC CEILING AND SUSPENSION SYSTEMS IN
STRICT ACCORDANCE WITH MANUFACTURER’S
RECOMMENDATIONS. FINISHED CEILINGS SHALL BE LEVEL, WITH
ALL JOINTS SNUG AND SQUARE.
4. SUSPENSION SYSTEM INSTALLATION SHALL COMPLY WITH ASTM
C636 REQUIREMENTS AND BE WATER OR LASER LEVEL.
5. CEILING SUSPENSION SYSTEM SHALL BE SUPPORTED DIRECTLY
FROM THE BUILDING STRUCTURE. PROVIDE ADDITIONAL
SUPPORT FRAMING AS REQUIRED. PROVIDE SUPPORT AT ALL
FOUR (4) CORNERS OF FLUORESCENT LIGHT FIXTURES.
6. PROVIDE WALL ANGLE MOLDING AT PERIMETER OF ALL CEILING
TILE INSTALLATIONS. ANCHOR MOLDING TO WALL AT EACH POINT
OF MAIN RUNNER AND CROSS TEE BEARINGS AND ADDITIONALLY
AS REQUIRED TO PREVENT MOLDING FROM SAGGING OR
TWISTING.
7. INSTALL CEILING TO PERMIT BORDER UNITS OF THE GREATEST
POSSIBLE SIZE.
8. COORDINATE WORK WITH ELECTRICAL PLANS AND/OR
ELECTRICAL SUB-CONTRACTOR TO CONFIRM LIGHT FIXTURES
ARE CORRECTLY LOCATED.
9. IF REQUIRED IN THIS PROJECT, COORDINATE WORK WITH
SPRINKLER SYSTEM INSTALLER.
10. REMOVE AND REPLACE UNITS, WHICH ARE DAMAGED OR
IMPROPERLY INSTALLED.
11. CLEAN PAINTED SURFACES DAMAGED BY WORK OF THIS
INSTALLATION.
SCALE: 1/4" = 1'-0"
REFLECTED CEILING PLAN
TYPICAL 24"x24"
DIFFUSER
TYPICAL 24"x24"
LED FIXTURE
24"x 48"
LED PANEL
FIXTURE
LAY-IN ACOUSTIC TILE
CEILING AT 10'-0" AFF
LAY-IN ACOUSTIC TILE
CEILING AT 10'-0" AFF
LAY-IN ACOUSTIC TILE
CEILING AT 10'-0" AFF
LAY-IN ACOUSTIC TILE
CEILING AT 10'-0" AFF
GENERAL NOTES – BULKHEADS
CEILING, SOFFIT AND BULKHEAD FRAMING SYSTEMS SHALL BE
DESIGNED TO CARRY CEILING DEAD LOADS IN ADDITION TO FRAMING
MEMBERS, LIGHT FIXTURES, AIR DIFFUSERS, SPEAKERS, INSULATION,
AND SIGNAGE, ETC.
BLOCKING AND FRAMING SHALL BE 2X4 MINIMUM AND BE 16” O.C.
FRAMING. IT MAY BE 24”” O.C. IF ATTACHED TO PRE-ENGINEERED
WOOD TRUSSES, AND NOTICE OF THE BULKHEAD CONDITION IS A PART
OF THE TRUSS DESIGN AND SPECIFICATIONS.
POSITIVE TENSION-TYPE CONNECTIONS BACK TO STRUCTURE IS
REQUIRED. UNISTRUT TYPE METAL CONNECTIONS OR EQUAL.
DRYWALL SHALL BE 5/8” TYPE X.
STRICTLY FOLLOW RECOMMENDATIONS OF THE USG CORPORATION
AND THE NATIONAL GYPSUM COMPANY’S GOLD BOND BUILDING
PRODUCTS DIVISION.
ALL ACCESSORIES, INCLUDING SIMPSON JOIST HANGERS, CLIPS,
SCREWS, AND NAILS ETC. SHALL BE PER ROUGH FRAMING
SPECIFICATIONS THAT ARE A PART OF THESE CONTRACT DOCUMENTS.
EXECUTION:
ARRANGE FRAMING FOR CEILINGS TO PROVIDE SUPPORT
INDEPENDENT OF WALLS, COLUMNS, PIPES, AND DUCTS AND INSTALL
ALL WORK PLUMB.
NOTIFY ARCHITECT IF ANY QUESTIONS ON STRUCTURAL ATTACHMENT
ARISE.
8'-0" AFF OR
PER COOLER MFGR.
MINIMUM 24" x 30"
ATTIC ACCESS
1
A3.1
1
1
A3.1
1
A3.1
1
1
A3.2
A3.2 A3.3
A3.3
A3.4
1
1
A3.5
1
A3.5
1
1
A3.4
1
A3.4
A3.4
A3.4
2
2
A1.3