Loading...
HomeMy WebLinkAboutCHS Natatorium Plans 11 x 17_All Variances_Carmel BZA_220014.00PROPOSED NATATORIUMBUILDING ADDITIONF.F.E.= 831.98 F.F.E.= 831.98 F.F.E.= 831.98 F.F.E.= 834.65 SMOKEY ROW ROAD / E 136TH STREET E MAIN STREET PARKING LOT ADDITION (NOT IN SCOPE OF THIS PROJECT) PERFORMING ARTS BUILDING ADDITION (UNDER CONSTRUCTION. NOT IN SCOPE OF THIS PROJECT) 3 10 12 6 PAVING AT MURRAY FIELD (NOT IN SCOPE OF THIS PROJECT) 12 5 5 15 3 NATATORIUM BUILDING ADDITION 15 12 14 13 10 10 9 8 7 6 5 4 32 1 11 22 10 26 8 200 6000 200 400 1. SEE DRAWING GD0.1 FOR GENERAL NOTES AND ADDITIONAL LEGEND. 2. BOUNDARY AND TOPOGRAPHIC SURVEY INFORMATION SHOWN WERE PROVIDED BY CIVIL ENVIRONMENTAL CONSULTANTS, INC. 3. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE PROJECT AREA INCLUDING UNDERGROUND UTILITY CONDITIONS, LOCATION AND DEPTH PRIOR TO ANY OTHER SITE CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER. GENERAL NOTES KEYNOTES PROPOSED BICYCLE RACKS MOUNTED TO EXISTING SIDEWALKS PROPOSED BICYCLE RACKS MOUNTED TO NEW SIDEWALKS 1 1 THE NUMBERS SHOWN IN THE SYMBOLS BELOW INDICATE THE QUANTITY OF BICYCLE RACKS PROPOSED IN A PARTICULAR AREA. 1 THE NUMBERS SHOWN IN THE SYMBOL BELOW INDICATE DESIGNATED PARKING LOT IDENTIFICATION. PARKING LOT IDENTIFICATION NUMBER BICYCLE RACK LOCATION SUMMARY TABLE LOCATION BICYCLE RACKS MAIN BUILDING 94 FOOTBALL STADIUM 28 12 3 137 TENNIS COURTS MURRAY STADIUM TOTAL BICYCLE RACKS 274TOTAL BICYCLE PARKING SPACES THE ABOVE BICYCLE RACKS ACCOMMODATE 5,480 STUDENTS BICYCLE SPACES REQUIRED = 1 PER 20 STUDENTS BUILDING AREA SUMMARY YEAR (2002 THROUGH 2021) PROJECT EXIST. AREA SF.NEW AREA SF.TOTAL AREA SF.% ADDED REMARKS 2002 FRESHMAN CENTER 2004 LOCKER ROOM 2012 PHYSICAL EDUCATION 2019 POOL ENTRANCE #21 2021 DOCK STORAGE 2021 PERFORMING ARTS 776,647 950,591 953,243 980,852 981,547 982,955 173,944 2,652 27,609 695 1,408 25,464 950,591 953,243 980,852 981,547 982,955 1,008,419 22.40 0.28 2.90 0.07 0.14 2.59 BZA APPROVAL WITH VARIANCES NO CLASSROOM IN ADDITION NO CLASSROOM IN ADDITION NO CLASSROOM IN ADDITION NO CLASSROOM IN ADDITION NO CLASSROOM IN ADDITION 2007 TENNIS BUILDING 1,700 SEPARATE BUILDING AT STADIUM SITE 2011 SECURE ENTRANCE 0 NO NEW CONSTRUCTION 2023 NATATORIUM 1,008,419 93,229 1,101,648 9.25 NO CLASSROOM IN ADDITION OVERALL PARKING SUMMARY LOT NO.LOT NAME STANDARD SPACE OLD SENIOR LOT 651 EXIST. PROPOSED 65 ADA SPACE 0 EXIST. 0 POLICE SPACE 0 EXIST. 0 BUS SPACE 0 EXIST. 0 TOTAL SPACES 65 EXIST. PROPOSED 65 2 3 4 5 6 7 8 9 10 12 13 14 15 DOOR 7 19 19 4 4 0 0 0 0 23 23 FRONT LOT 109 103 3 7 3 3 0 0 115 113 AUDITORIUM LOT 52 0 4 0 0 0 0 0 56 0 WEST LOT 69 69 0 0 0 0 0 0 69 69 FRESHMAN CENTER LOT 142 142 6 6 1 1 0 0 149 149 FIELDHOUSE LOT 29 29 FITNESS CENTER LOT 20 2 22 POOL LOT 110 0 8 0 1 0 0 0 119 TRAIL LOT 152 221 0 7 0104 152 229 SUBTOTAL 766 686 27 26 550 4 799 697 FOOTBALL HOME LOT 948 948 11 11 0 0 0 0 959 959 FOOTBALL SOUTH LOT 143 143 0 0 0 0 21 = 42 21 = 42 185 185 FOOTBALL VISITOR LOT 516 516 9 9 0 0 0 0 525 525 FOOTBALL NORTH LOT 79 79 0 0 0 0 0 0 79 79 29 0 0 0 0 0 0 29 0000000 0 PROPOSED PROPOSED PROPOSED 2,4452,547TOTAL CITY OF CARMEL REQUIRED PARKING SPACES (235 CLASSROOMS x 10) + (583 EMPLOYEES) = 2,933 (UPON COMPLETION OF THE NATATORIUM PROJECT) SUBTOTAL 1,686 1,686 20 20 0 0 1,748 1,74821 = 42 21 = 42 AVAILABLE PARKING SPACES UNTIL JUNE 2022 (LOTS 8 & 9) = 2,644 PERMIT PARKING SPACES = 1334 (STUDENTS) + 583 (EMPLOYEES) = 1,917 NOTES: 1. THE CARMEL HIGH SCHOOL PARKING POLICY IS BASED ON PERMIT ISSUED PARKING. THERE ARE 1,917 PERMITS ISSUED. 2. ENROLLMENT IS EXPECTED TO DROP BY 75 STUDENTS IN 2022 AND REMAIN LEVEL THROUGH 2029. 3. BUS PARKING AT THE FOOTBALL STADIUM IS CURRENTLY 21 SPACES. THESE SPACES CAN ALSO BE USED FOR STUDENT PARKING AT TWO (2) STANDARD VEHICLE SPACES FOR EACH BUS SPACE. THE 21 BUS PARKING SPACES ALLOWS FOR 42 STUDENT PARKING SPACES. 4. THE NATATORIUM PROJECT IS SCHEDULED FOR CONSTRUCTION IN JUNE OF 2022. LOTS 8 & 9 WITH 141 SPACES WILL BE AVAILABLE UNTIL THEN. 11 MURRAY FIELD LOT 0 18 0 2 0 0 0 0 0 20 AVAILABLE PARKING SPACES AFTER JUNE 2022 = 2,351 AVAILABLE PARKING SPACES AFTER DECEMBER 2023 = 2,445 PROJECT PARKING SUMMARY LOT NO. (NATATORIUM BUILDING ADDITION) LOT NAME STANDARD SPACE POOL LOT 1109 EXIST. PROPOSED 0 ADA SPACE 8 EXIST. 0 POLICE SPACE 1 EXIST. 0 BUS SPACE 0 EXIST. 0 TOTAL SPACES 119 EXIST. 0 TRAIL LOT 15210 221 0 7 0 1 0 4 152 229 MURRAY FIELD LOT 011 18 0 2 0 0 0 0 0 20 PROJECT TOTAL 282 239 10 9 1 1 0 4 293 249 NET LOSS = 44 SPACES PROPOSED PROPOSED PROPOSED PROPOSED FITNESS CENTER LOT 208 02 00 00 0220 TBM#4 = 810.78 LOT 52 LOT 53 LOT 54 LOT 55 LOT 56 LOT 57 LOT 58 LOT 59 LOT 60 LOT 61 PROPOSED NATATORIUM BUILDING ADDITION F.F.E.= 831.98 F.F.E.= 831.98 F.F.E.= 831.98 F.F.E.= 834.65 20 - PROPOSED PARKING SPACES 74 - PROPOSED PARKING SPACES 103.0' 53. 9 ' 25. 0 ' BU I L D I N G SE T B A C K 30. 0 ' LA N D S C A P E BU F F E R 30.0' LANDSC A P E BUFFER 25.0' BUILDING SETBACK 40 12004080 INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES SHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAY ALL CONSTRUCTION. THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES, SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUND CAUTION !! Know what's R Call 811 or 1-800-382-5544 Before You Begin Any Digging Project. Call 48 hours or 2 working days before you dig. It's Fast, It's Easy and It's the Law in the state of Indiana! 1. SEE DRAWING GD0.1 FOR GENERAL NOTES AND ADDITIONAL LEGEND. 2. TOPOGRAPHIC CONDITIONS AND EXISTING UTILITIES SHOWN WERE PROVIDED BY THE SURVEYOR. THE ENGINEER MAKES NO GUARANTEES THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. 3. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE PROJECT AREA INCLUDING UNDERGROUND UTILITY CONDITIONS, LOCATION AND DEPTH PRIOR TO ANY OTHER SITE CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER. 4. NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. 5. UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE DEVELOPERS RESPONSIBILITY TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED TO WITHIN ONE FOOT OF PROPOSED RIGHT-OF-WAY LINE. 6. DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL RESTORED/REPAIRED TO THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. 7. REFER TO SITE DETAILS ON SHEETS G4.1 AND G4.2 GENERAL NOTES PROPOSED SITE LEGEND EXISTING BUILDING BUILDING ADDITION CONCRETE PAVEMENT / WALK ASPHALT PAVEMENT LANDSCAPE OR LAWN / TURF AREA (SEE LANDSCAPE PLAN FOR INFORMATION) TBM#4 = 810.78 PROPOSED NATATORIUM BUILDING ADDITION F.F.E.= 831.98 F.F.E.= 831.98 R25.0'25.0'8 . 0 '8.0'20. 0 ' TY P . R3 0 . 0 '23.0'EXISTING23.9' EXISTIN G 2 0 . 0 'R3 0 . 0 ' 1 4 . 0 '12.0'25.0'12.0'8.0'8.0'8.2'R30.0 ' R30.0' 15 2 1 9 2 16 2 5 7 5 2 2 18 18 18 3 3 3 4 4 4 5 5 5 5 66 6 6 7 6 6 8 8 8 11 11 10 11 10 11 11 25 13 13 7 17 4 18 11 10 4 2 2 3 20 520 11 10 9 1 11 11 11 20.0' 8 . 0 ' 4 4 6 20.0'6 5.0' 24 12 66 8.0' 21 TYP. 21 TYP. 21 TYP. 21 TYP. 21 TYP. 21 TYP.20.0'12.5'18 18 10 SPA. @ 9 ' - 0 " = 9 0 . 0 ' 5' 5' 5' 8.0'8.0' 8.0'8.0' 8.0' 8.0' 8.0' 8.0' 15 SPA. @ 9 ' - 0 " = 1 3 5 . 0 ' 15 SPA. @ 9 ' - 0 " = 1 3 5 . 0 ' 18 SPA. @ 9 ' - 0 " = 1 6 2 . 0 '9 SPA. @ 9'-0" = 81.0'20.0'20.0'25.0'20.0'12.5'20.0' 25.0' 19 19 5 3 1 12 5 5 3 15.0' 15.0' R42.0'R30.0' R30 . 0 'R50.0'11.5' 15.0' 8 25.0' 7.2' 103.0' 25.0' 25.0' 30.0' LANDSCA P E B U F F E R 25.0' BUILDING S E T B A C K 20 6002040 INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES SHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAY ALL CONSTRUCTION. THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES, SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUND CAUTION !! Know what's R Call 811 or 1-800-382-5544 Before You Begin Any Digging Project. Call 48 hours or 2 working days before you dig. It's Fast, It's Easy and It's the Law in the state of Indiana! 1. SEE DRAWING GD0.1 FOR GENERAL NOTES AND ADDITIONAL LEGEND. 2. TOPOGRAPHIC CONDITIONS AND EXISTING UTILITIES SHOWN WERE PROVIDED BY THE SURVEYOR. THE ENGINEER MAKES NO GUARANTEES THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. 3. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE PROJECT AREA INCLUDING UNDERGROUND UTILITY CONDITIONS, LOCATION AND DEPTH PRIOR TO ANY OTHER SITE CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER. 4. NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. 5. UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE DEVELOPERS RESPONSIBILITY TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED TO WITHIN ONE FOOT OF PROPOSED RIGHT-OF-WAY LINE. 6. DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL RESTORED/REPAIRED TO THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. 7. REFER TO SITE DETAILS ON SHEETS G4.1, G4.2 AND G4.3 8. THE CONTRACTOR SHALL REMOVE AN ADDITIONAL 12" OF SOIL BELOW PROPOSED STONE BASE UNDER ALL NEW PAVEMENT. GENERAL NOTES SITE KEYNOTES 6" CONCRETE PAVEMENT, SEE DETAIL ON SHEET G4.1 HEAVY DUTY ASPHALT PAVEMENT, SEE DETAIL ON SHEET G4.1 MEDIUM DUTY ASPHALT PAVEMENT, SEE DETAIL ON SHEET G4.1 MONOLITHIC CURB AND WALK, SEE DETAIL ON SHEET G4.1 CONCRETE SIDEWALK, SEE DETAIL ON SHEET G4.1 6" CONCRETE CURB, SEE DETAIL ON SHEET G4.1 CONCRETE ROLL CURB & GUTTER, SEE DETAIL ON SHEET G4.1 CONCRETE ADA CURB RAMP, SEE DETAILS ON SHEET G4.3 CONCRETE SPEED CONTROL TABLE, SEE DETAIL ON SHEET G4.2 LANDSCAPE AREA, SEE LANDSCAPE PLAN SHEET L1.0 LAWN / TURF AREA, SEE LANDSCAPE PLAN SHEET L1.0 RETAINING WALL AT RAMP/WALK, SEE DETAIL ON SHEET G4.2 CONCRETE STEPS WITH HANDRAILS, SEE DETAIL ON SHEET G4.2 CONCRETE ADA RAMP, SEE DETAILS ON SHEET G4.3 RELOCATED 8' CHAIN LINK FENCE CONCRETE MEDIAN WITH ROLL CURB & GUTTER GUARDRAIL, SEE DETAIL ON SHEET G4.1 ASPHALT RESURFACE AREA RELOCATED IRON VEHICLE GATE AND POSTS STAMPED CONCRETE CONCRETE PARKING BUMPER, SEE DETAIL ON SHEET G4.1 CONCRETE STEPS WITH 2 RISERS, SEE GRADING PLAN FOR ELEVATIONS PLANTER WALL, SEE DETAIL ON SHEET G4.2 RETAINING WALL MODULAR BLOCK RETAINING WALL, SEE DETAIL ON SHEET G4.2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 PROPOSED SITE LEGEND EXISTING BUILDING BUILDING ADDITION CONCRETE PAVEMENT / WALK ASPHALT PAVEMENT LANDSCAPE OR LAWN / TURF AREA LOT 52 LOT 53 LOT 54 LOT 55 LO PROPOSED NATATORIUM BUILDING ADDITION F.F.E.= 831.98 F.F.E.= 831.98 F.F.E.= 834.65 2 5 11 10 4 4 4 2 13 24 14 14 2 2 2 24 22 22 23 23 5R50.0'25.0' BUILDING S E T B A C K 53. 9 ' 25. 0 ' BUI L D I N G S E T B A C K 30. 0 ' LA N D S C A P E B U F F E R 25.0' 5.0' 23. 0 ' EXI S T I N G 5.0' 20 6002040 INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES SHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAY ALL CONSTRUCTION. THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES, SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUND CAUTION !! Know what's R Call 811 or 1-800-382-5544 Before You Begin Any Digging Project. Call 48 hours or 2 working days before you dig. It's Fast, It's Easy and It's the Law in the state of Indiana! 1. SEE DRAWING GD0.1 FOR GENERAL NOTES AND ADDITIONAL LEGEND. 2. TOPOGRAPHIC CONDITIONS AND EXISTING UTILITIES SHOWN WERE PROVIDED BY THE SURVEYOR. THE ENGINEER MAKES NO GUARANTEES THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. 3. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE PROJECT AREA INCLUDING UNDERGROUND UTILITY CONDITIONS, LOCATION AND DEPTH PRIOR TO ANY OTHER SITE CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER. 4. NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. 5. UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE DEVELOPERS RESPONSIBILITY TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED TO WITHIN ONE FOOT OF PROPOSED RIGHT-OF-WAY LINE. 6. DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL RESTORED/REPAIRED TO THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. 7. REFER TO SITE DETAILS ON SHEETS G4.1, G4.2 AND G4.3 8. THE CONTRACTOR SHALL REMOVE AN ADDITIONAL 12" OF SOIL BELOW PROPOSED STONE BASE UNDER ALL NEW PAVEMENT. GENERAL NOTES SITE KEYNOTES 6" CONCRETE PAVEMENT, SEE DETAIL ON SHEET G4.1 HEAVY DUTY ASPHALT PAVEMENT, SEE DETAIL ON SHEET G4.1 MEDIUM DUTY ASPHALT PAVEMENT, SEE DETAIL ON SHEET G4.1 MONOLITHIC CURB AND WALK, SEE DETAIL ON SHEET G4.1 CONCRETE SIDEWALK, SEE DETAIL ON SHEET G4.1 6" CONCRETE CURB, SEE DETAIL ON SHEET G4.1 CONCRETE ROLL CURB & GUTTER, SEE DETAIL ON SHEET G4.1 CONCRETE ADA CURB RAMP, SEE DETAILS ON SHEET G4.3 CONCRETE SPEED CONTROL TABLE, SEE DETAIL ON SHEET G4.2 LANDSCAPE AREA, SEE LANDSCAPE PLAN SHEET L1.0 LAWN / TURF AREA, SEE LANDSCAPE PLAN SHEET L1.0 RETAINING WALL AT RAMP/WALK, SEE DETAIL ON SHEET G4.2 CONCRETE STEPS WITH HANDRAILS, SEE DETAIL ON SHEET G4.2 CONCRETE ADA RAMP, SEE DETAILS ON SHEET G4.3 RELOCATED 8' CHAIN LINK FENCE CONCRETE MEDIAN WITH ROLL CURB & GUTTER GUARDRAIL, SEE DETAIL ON SHEET G4.1 ASPHALT RESURFACE AREA RELOCATED IRON VEHICLE GATE AND POSTS STAMPED CONCRETE CONCRETE PARKING BUMPER, SEE DETAIL ON SHEET G4.1 CONCRETE STEPS WITH 2 RISERS, SEE GRADING PLAN FOR ELEVATIONS PLANTER WALL, SEE DETAIL ON SHEET G4.2 RETAINING WALL MODULAR BLOCK RETAINING WALL, SEE DETAIL ON SHEET G4.2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 PROPOSED SITE LEGEND EXISTING BUILDING BUILDING ADDITION CONCRETE PAVEMENT / WALK ASPHALT PAVEMENT LANDSCAPE OR LAWN / TURF AREA TBM#4 = 810.78 5.0'9 SPA. @ 9 ' - 0 " = 8 1 . 0 ' 9.0'9.0'9.0' EDGE OF EXISTING ASPHALT PAVEMENT EXISTING TRENCH DRAIN 6 TYP. 1 TYP. 1 TYP. 9 SPA. @ 9 ' - 0 " = 8 1 . 0 ' 1 TYP. 1 TYP. 5 3 4 2 9.0' TYP 20.0'VARIES ±40'20.0'4 1.7' 5 6 TYP. 5 9.0' TYP7.5' 18. 0 ' EXI S T I N G DRI V E R25.0'R1 0 . 0 '25.0'7 7 5 5.0'10.0'25.0'±10'R5 . 0 'R35.0' 109 INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES SHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAY ALL CONSTRUCTION. THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES, SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUND CAUTION !! Know what's R Call 811 or 1-800-382-5544 Before You Begin Any Digging Project. Call 48 hours or 2 working days before you dig.It's Fast, It's Easy and It's the Law in the state of Indiana! 1. SEE DRAWING GD0.1 FOR GENERAL NOTES AND ADDITIONAL LEGEND. 2. TOPOGRAPHIC CONDITIONS AND EXISTING UTILITIES SHOWN WERE PROVIDED BY THE SURVEYOR. THE ENGINEER MAKES NO GUARANTEES THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. 3. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE PROJECT AREA INCLUDING UNDERGROUND UTILITY CONDITIONS, LOCATION AND DEPTH PRIOR TO ANY OTHER SITE CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER. 4. NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. 5. UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE DEVELOPERS RESPONSIBILITY TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED TO WITHIN ONE FOOT OF PROPOSED RIGHT-OF-WAY LINE. 6. REFER TO SITE DETAILS ON SHEETS G4.1 AND G4.2. 7. COORDINATE PARKING LOT LAYOUT WITH PROPOSED BLEACHER LAYOUT. GENERAL NOTES SITE KEYNOTES 4" SOLID WHITE PAVEMENT MARKING 4" SOLID BLUE PAVEMENT MARKING 4" SOLID BLUE PAVEMENT MARKING @ 3'-0" O.C. @ 45° ADA PARKING SYMBOL (BLUE) 4" SOLID WHITE PAVEMENT MARKING @ 3'-0" O.C. @ 45° PRECAST PARKING BUMPER, SEE DETAIL ON SHEET G4.1 4' TALL BLACK VINYL CHAIN LINK FENCE NEW BLEACHER (NOT IN CONTRACT) RELOCATED 8' CHAIN LINK FENCE MODULAR BLOCK RETAINING WALL, SEE DETAIL ON SHEET G4.2 1 2 3 4 5 6 7 8 9 10 PROPOSED SITE LEGEND EXISTING BUILDING CONCRETE PAVEMENT / WALK ASPHALT PAVEMENT LANDSCAPE OR LAWN / TURF AREA 20 6002040 PROPOSED NATATORIUM BUILDING ADDITION F.F.E.= 831.98 F.F.E.= 831.98 F.F.E.= 831.98 F.F.E.= 834.65 TBM#4 = 810.78 LOT 52 LOT 53 LOT 54 LOT 55 LOT 56 LOT 57 LOT 58 LOT 59 LOT 60 LOT 61 FH1 FH2 FH4 G FH3 ST-101 ST-401 ST-305 ST-302 ST-102 ST-201 ST-303 ST-301 ST-105 ST-202 ST-402 ST-103 ST-405 ST-404 ST-104 ST-304 ST-406 ST-203 ST-306 ST-501 ST-204 ST-403 ST-502 ST-500 IN ST-500 OUT 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 UNDERGROUND DETENTION BOTTOM OF CHAMBER = 812.00 TOP OF CHAMBER = 819.00 10 YEAR ELEVATION = 815.32 10 YEAR RELEASE RATE = 1.36 CFS 10 YEAR STORAGE VOLUME = 0.084 AC/FT 100 YEAR ELEVATION = 818.22 100 YEAR RELEASE RATE = 1.88 CFS 100 YEAR STORAGE VOLUME = 0.168 AC/FT 2 SAN-1 SAN-2 BENCHMARKS: 40 12004080 INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES SHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAY ALL CONSTRUCTION. THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES, SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUND CAUTION !! Know what's R Call 811 or 1-800-382-5544 Before You Begin Any Digging Project. Call 48 hours or 2 working days before you dig. It's Fast, It's Easy and It's the Law in the state of Indiana! 1. SEE DRAWING GD0.1 FOR GENERAL NOTES AND ADDITIONAL LEGEND. 2. TOPOGRAPHIC CONDITIONS AND EXISTING UTILITIES SHOWN WERE PROVIDED BY THE SURVEYOR. THE ENGINEER MAKES NO GUARANTEES THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. 3. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE PROJECT AREA INCLUDING UNDERGROUND UTILITY CONDITIONS, LOCATION AND DEPTH PRIOR TO ANY OTHER SITE CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER. 4. NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. 5. UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE DEVELOPERS RESPONSIBILITY TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED TO WITHIN ONE FOOT OF PROPOSED RIGHT-OF-WAY LINE. 6. DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL RESTORED/REPAIRED TO THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. 7. REFER TO UTILITY DETAILS ON SHEETS SU2.1, SU2.2 AND SU2.3 8. REFER TO STORM STRUCTURE TABLE ON SHEET SU2.3 GENERAL NOTES GRADING PLAN LEGEND EXISTING SPOT ELEVATION MATCH EXISTING GRADE TOP OF CURB BOTTOM OF CURB EXISTING CONTOUR W/ ELEVATION PROPOSED CONTOUR W/ ELEVATION PROPOSED SPOT ELEVATION PROPOSED CURB ELEVATION PROPOSED SURFACE DRAINAGE FLOW ARROW FLOOD ROUTING PATH MEG TC BC TC BC 750.65 100 YEAR INLET CASTING CAPACITY ELEVATION TABLE STRUCTURE NUMBER 100 YEAR ELEVATION (INLET 50% CLOGGED) 204 R-3010 NEENAH INLET CASTING TYPE 823.19 TOP OF CASTING ELEVATION 823.38 301 302 303 304 305 403 825.08 825.68 828.09 828.25 825.68 825.71 823.67 824.73 831.63 831.84 822.48 823.14 R-3010 R-3010 R-3010 R-3010 R-3472 R-3010 FLOOD ROUTING KEYNOTES 1. FLOOD ROUTING PATH FOR THE IMPROVEMENTS ON THE NORTH SIDE OF THE PROJECT WHEN 100 YEAR FLOOD IS EXCEEDED. PATH TRAVELS IN A NORTHERLY AND NORTHEASTERLY DIRECTION OVER PROPOSED AND EXISTING INLETS THEN CONTINUES IN A NORTHERLY NORTHWESTERLY DIRECTION TO STADIUM DRIVE THEN CONTINUES NORTHERLY TO EXISTING INLETS LOCATED ON THE NORTH SIDE OF THE BRIDGE OVER COOL CREEK. 2. FLOOD ROUTING PATH FOR THE IMPROVEMENTS ON THE EAST SIDE OF THE PROJECT WHEN 100 YEAR FLOOD IS EXCEEDED. PATH TRAVELS FROM THE EAST SIDE DRIVE AND THEN TRAVELS IN A NORTHERLY DIRECTION OVER MULTIPLE EXISTING CURB INLETS LOCATED ON THE EAST SIDE OF THE DRIVE. EVENTUALLY GRADE LEVELS OUT ON THE EAST DRIVE NEAR THE NORTHEAST CORNER OF THE HIGH SCHOOL BUILDING AND IF PONDING DEPTH EXCEEDS SIX INCHES FLOOD ROUTING PATH WILL OVERTOP CURB AND TRAVEL EAST TO A EXISTING SWALE AND THEN TRAVEL NORTH IN THE SWALE TO COOL CREEK. TBM#4 = 810.78 PROPOSED NATATORIUM BUILDING ADDITION F.F.E.= 831.98 F.F.E.= 831.98 FH1 FH2 FH3 TC 824.19 BC 823.69 TC 824.53 BC 824.03 TC 824.86 BC 824.36 TC 825.16 BC 824.66 TC 825.18 BC 824.68 TC 824.92 BC 824.42 TC 824.25 BC 823.75 825.24 823.19 823.54 823.87 824.18 824.21 823.91 823.50 831.84 824.34 824.12 824.00 823.92 823.40 822.69 822.70 822.87 822.99 822.82 MEG 822.42 EXPOSED FOUNDATION WALL ALONG EAST SIDE OF BUILDING 831.82 831.98 828.14 830.16 822.78 821.83 MEG 820.53 MEG 820.60 MEG 827.89 MEG 832 62 EXISTING STEPS AND RAMP TO REMAIN IN PLACE TC 824.01 BC 823.51 TC 831.97 BC 831.47 TC 832.04 BC 831.54 TC 829.89 BC 829.39 MEG 832.30 MEG 832.44 MEG 832.43 832.19 TC 825.83 BC 825.33 TC 824.43 BC 823.93 MEG 822.76 MEG 822.46 MEG 821.26 823.42 823.59 823.43 822.82 822.99 822.83 821.66 822.75 823.25 823.90 824.06 824.06 MEG 829.78 829.61 TC 829.40 BC 828.90 826.00 825.77 824.54 831.86 824.34 826.00 825.00 831 63 832.27 830.57 TC 830.36 BC 829.86 831.24 TC 831.08 BC 830.58 TC 831.07 BC 830.57 TC 828.86 BC 828.36 TC 828.17 BC 827.67 829.12 831.82 831.98 831.82 828.46 828.14 824.06 831.84 826.00 823.64 822.44 823.89 824.08 823.40 823.45 828.09 TC 826.33 BC 825.83 TC 823.61 BC 823.11 825.73 829.72 826.00 823.69 823.45 823.62 825.08 ST-305 RIM. = 831.63' ST-302 RIM. = 828.09' ST-303 RIM. = 825.68' ST-301 RIM. = 825.08' ST-402 RIM. = 824.31' ST-105 RIM. = 824.37' ST-202 RIM. = 824.34' ST-405 RIM. = 823.76' ST-406 RIM. = 823.54' ST-104 RIM. = 823.73' ST-304 RIM. = 823.67' ST-404 RIM. = 823.76' ST-203 RIM. = 823.45' ST-306 RIM. = 823.40' ST-204 ST-501 RIM. = 823.27' ST-403 RIM. = 822.46' ST-502 RIM. = 818.88' ST-500 IN RIM. = 824.56' ST-500 OUT RIM. = 823.51' MEG 832.42 MEG 828.17 MEG 828.54 TC 829.12 BC 828.62 828.44 MEG 828.27 STORMTRAP UNDERGROUND DETENTION SYSTEM 826.00 826.00 BENCHMARKS: 20 6002040 INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES SHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAY ALL CONSTRUCTION. THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES, SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUND CAUTION !! Know what's R Call 811 or 1-800-382-5544 Before You Begin Any Digging Project. Call 48 hours or 2 working days before you dig. It's Fast, It's Easy and It's the Law in the state of Indiana! 1. SEE DRAWING GD0.1 FOR GENERAL NOTES AND ADDITIONAL LEGEND. 2. TOPOGRAPHIC CONDITIONS AND EXISTING UTILITIES SHOWN WERE PROVIDED BY THE SURVEYOR. THE ENGINEER MAKES NO GUARANTEES THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. 3. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE PROJECT AREA INCLUDING UNDERGROUND UTILITY CONDITIONS, LOCATION AND DEPTH PRIOR TO ANY OTHER SITE CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER. 4. NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. 5. UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE DEVELOPERS RESPONSIBILITY TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED TO WITHIN ONE FOOT OF PROPOSED RIGHT-OF-WAY LINE. 6. DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL RESTORED/REPAIRED TO THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. 7. REFER TO UTILITY DETAILS ON SHEETS SU2.1, SU2.2 AND SU2.3 8. REFER TO STORM STRUCTURE TABLE ON SHEET SU2.3 GENERAL NOTES GRADING PLAN LEGEND EXISTING SPOT ELEVATION MATCH EXISTING GRADE TOP OF CURB BOTTOM OF CURB EXISTING CONTOUR W/ ELEVATION PROPOSED CONTOUR W/ ELEVATION PROPOSED SPOT ELEVATION PROPOSED CURB ELEVATION MEG TC BC TC BC 750.65 LOT 52 LOT 53 LOT 54 LOT 55 LO PROPOSED NATATORIUM BUILDING ADDITION F.F.E.= 831.98 F.F.E.= 831.98 F.F.E.= 834.65 FH1 FH4 G 827.94 TC 827.81 BC 827.31 831.98 831.98 828.55 TC 829.15 BC 828.65 TC 826.75 BC 826.25 TC 825.78 BC 825.28 TC 825.51 BC 825.01 TC 824.73 BC 824.23 TC 824.31 BC 823.81 TC 823.93 BC 823.43 TC 823.57 BC 823.07 TC 823.00 BC 822.50 TC 823.42 BC 822.92 TC 823.73 BC 823.23 TC 824.19 BC 823.69 TC 824.53 BC 824.03 827.07 826.36 831.81 825.84 831.11 830.07 829.02 828.50 827.66 826.84 825.78 824.81 824.54 823.74 823.30 822.92 822.57 822.00 822.42 822.74 823.19 823.54 EXPOSED FOUNDATION WALL ALONG EAST SIDE OF BUILDING 831.86 831.98 833.23 833.29 831.82 830.16 MEG 832.62 EXISTING STEPS AND RAMP TO REMAIN IN PLACE TC 832.04 BC 831.54 MEG 832.30 MEG 832.44 MEG 832.43 832.19 825.00 834.65 834.48 834.63 834.63 834.63 834.52 834.35 833.35 834.35 833.35 833.33 832.00 832.44 832.40 832.44 831.63 831.98 832.62 832.51 834.52 832.18 834.22 832.27 TC 831.07 BC 830.57 828.29 831.81 TC 829.98 BC 829.48 TC 829.46 BC 828.96 829.55 829.24 828.02 828.17 828.10 828.24 TC 828.03 BC 827.53 827.99 828.18 828.81 827.73 828.19 825.76 833.26 828.00 823.81 823.45 832.72 823.45 833.28 834.65 830.74 831.90 830.31 831.86 828.55 831.86 ST-101 RIM. = 833.26' ST-401 RIM. = 832.72' ST-305 RIM. = 831.63' ST-102 RIM. = 828.00' ST-201 RIM. = 825.75' ST-202 RIM. = 824.34' ST-103 RIM. = 823.81' RIM. = 823.73' ST-203 RIM. = 823.45' ST-204 RIM. = 823.19' 833.28 834.22 832.09 831.95 MEG 832.42 826.00 826.00 BENCHMARKS: 20 6002040 INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES SHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAY ALL CONSTRUCTION. THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES, SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUND CAUTION !! Know what's R Call 811 or 1-800-382-5544 Before You Begin Any Digging Project. Call 48 hours or 2 working days before you dig. It's Fast, It's Easy and It's the Law in the state of Indiana! 1. SEE DRAWING GD0.1 FOR GENERAL NOTES AND ADDITIONAL LEGEND. 2. TOPOGRAPHIC CONDITIONS AND EXISTING UTILITIES SHOWN WERE PROVIDED BY THE SURVEYOR. THE ENGINEER MAKES NO GUARANTEES THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. 3. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE PROJECT AREA INCLUDING UNDERGROUND UTILITY CONDITIONS, LOCATION AND DEPTH PRIOR TO ANY OTHER SITE CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER. 4. NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. 5. UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE DEVELOPERS RESPONSIBILITY TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED TO WITHIN ONE FOOT OF PROPOSED RIGHT-OF-WAY LINE. 6. DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL RESTORED/REPAIRED TO THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. 7. REFER TO UTILITY DETAILS ON SHEETS SU2.1, SU2.2 AND SU2.3 8. REFER TO STORM STRUCTURE TABLE ON SHEET SU2.3 GENERAL NOTES GRADING PLAN LEGEND EXISTING SPOT ELEVATION MATCH EXISTING GRADE TOP OF CURB BOTTOM OF CURB EXISTING CONTOUR W/ ELEVATION PROPOSED CONTOUR W/ ELEVATION PROPOSED SPOT ELEVATION PROPOSED CURB ELEVATION MEG TC BC TC BC 750.65 TBM#4 = 810.78 LOT 53 LOT 54 LOT 55 LOT 56 LOT 57 LOT 58 LOT 59 LOT 60 LOT 61 PROPOSED NATATORIUM BUILDING ADDITION F.F.E.= 831.98 F.F.E.= 831.98 F.F.E.= 831.98 F.F.E.= 834.65 FH1 FH2 FH4 G FH3 ST-401 ST-305 ST-101 ST-201 ST-302 ST-102 ST-202 ST-306 ST-203 BMP ST-402 ST-303 ST-301 ST-103 ST-104 ST-304 ST-105 ST-502 ST-204 ST-403 ST-404 ST-501 ST-406 BMP ST-500 IN ST-500 OUT ST-405 STORMTRAP UNDERGROUND DETENTION SYSTEM 40 12004080 INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES SHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAY ALL CONSTRUCTION. THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES, SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUND CAUTION !! Know what's R Call 811 or 1-800-382-5544 Before You Begin Any Digging Project. Call 48 hours or 2 working days before you dig. It's Fast, It's Easy and It's the Law in the state of Indiana! 1. SEE DRAWING GD0.1 FOR GENERAL NOTES AND ADDITIONAL LEGEND. 2. TOPOGRAPHIC CONDITIONS AND EXISTING UTILITIES SHOWN WERE PROVIDED BY THE SURVEYOR. THE ENGINEER MAKES NO GUARANTEES THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. 3. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE PROJECT AREA INCLUDING UNDERGROUND UTILITY CONDITIONS, LOCATION AND DEPTH PRIOR TO ANY OTHER SITE CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER. 4. NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. 5. UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE DEVELOPERS RESPONSIBILITY TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED TO WITHIN ONE FOOT OF PROPOSED RIGHT-OF-WAY LINE. 6. DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL RESTORED/REPAIRED TO THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. 7. REFER TO UTILITY DETAILS ON SHEET SU2.1, SU2.2, SU2.3, SU2.4, SU2.5 AND SU2.6 8. REFER TO STORM STRUCTURE TABLE ON SHEET SU2.3 9. SEE SHEETS SU1.1 AND SU1.2 FOR SANITARY PLAN INFORMATION AND SHEET SU2.2 FOR SANITARY DETAILS GENERAL NOTES UTILITY LEGEND NEW STORM SEWER LINE NEW FIRE PROTECTION LINE NEW SANITARY LATERAL LINE NEW NATURAL GAS LINE EXISTING STORM LINE EXISTING WATER LINE EXISTING SANITARY LINE EXISTING ELECTRICAL LINE NEW UNDERDRAIN OR TBM#4 = 810.78 PROPOSED NATATORIUM BUILDING ADDITION F.F.E.= 831.98 F.F.E.= 831.98 TBM#4 = 810.78 FH1 FH2 FH3 ST-302 RIM. = 828.09' INV. 823.49 (N) ST-202 RIM. = 824.34' INV. 820.34 (S) INV. 818.84 (E) INV. 820.34 (N) ST-203 RIM. = 823.45' INV. 818.74 (W) INV. 818.74 (E) ST-303 RIM. = 825.68' INV. 820.97 (E) INV. 820.57 (NE) INV. 821.97 (S) INV. 822.38 (W)ST-402 RIM. = 824.31' INV. 820.33 (S) INV. 820.23 (E) ST-301 RIM. = 825.08' INV. 821.39 (W) ST-104 RIM. = 823.73' INV. 815.32 (S) INV. 815.22 (N) ST-304 RIM. = 823.67' INV. 819.62 (E) ST-105 RIM. = 824.37' INV. 814.95 (S) INV. 814.85 (W) ST-306 RIM. = 823.40' INV. 814.10 (E) INV. 809.85 (N) INV. 815.35 (SW) INV. 819.55 (W) INV. 809.85 (S) ST-502 RIM. = 818.88' INV. 809.60 (S) INV. 809.50 (N) INV. 812.38 (E) ST-403 RIM. = 822.46' INV. 818.77 (S) 3 3 3 7 7 4 19 19 1 2 19 19 17 17 9 9 2 8 8 8 18 18 18 18 18 18 18 18 18 18 12 ST-404 RIM. = 823.76' INV. 818.64 (N) INV. 818.54 (W) 6" SAN. LATERAL INV.= 825.23 6" SAN. LATERAL INV.= 825.39 1 SAN-2 SAN. MANHOLE RIM. = 827.45' INV. 817.05 (NW) INV. 817.25 (S) INV. 818.95 (SE) SAN-1 SAN. DROP MANHOLE DOGHOUSE CONNECTION RIM. = 827.41' INV. 816.39 (SE) INV. 811.61 (N) INV. 811.61 (S) ST-501 RIM. = 823.27' INV. 812.00 (E) INV. 812.00 (N) ST-500 OUT INV. 812.00 (W) ST-500 IN INV. 816.50 (S) ST-406 RIM. = 823.54' INV. 816.53 (S) INV. 816.53 (N)ST-405 RIM. = 823.76' INV. 819.96 (W) INV. 816.56 (N) INV. 818.36 (E) 7 7 2 23 STORMTRAP UNDERGROUND DETENTION SYSTEM 8 24 24 24 24 24 3 25 17 2 26 21 27 20 6002040 INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES SHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAY ALL CONSTRUCTION. THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES, SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUND CAUTION !! Know what's R Call 811 or 1-800-382-5544 Before You Begin Any Digging Project. Call 48 hours or 2 working days before you dig. It's Fast, It's Easy and It's the Law in the state of Indiana! 1. SEE DRAWING GD0.1 FOR GENERAL NOTES AND ADDITIONAL LEGEND. 2. TOPOGRAPHIC CONDITIONS AND EXISTING UTILITIES SHOWN WERE PROVIDED BY THE SURVEYOR. THE ENGINEER MAKES NO GUARANTEES THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. 3. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE PROJECT AREA INCLUDING UNDERGROUND UTILITY CONDITIONS, LOCATION AND DEPTH PRIOR TO ANY OTHER SITE CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER. 4. NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. 5. UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE DEVELOPERS RESPONSIBILITY TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED TO WITHIN ONE FOOT OF PROPOSED RIGHT-OF-WAY LINE. 6. DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL RESTORED/REPAIRED TO THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. 7. REFER TO UTILITY DETAILS ON SHEETS SU2.1, SU2.2, SU2.3, SU2.4, SU2.5 AND SU2.6 8. REFER TO STORM STRUCTURE TABLE ON SHEET SU2.3 GENERAL NOTES UTILITY KEYNOTES 1. 10" PVC SANITARY LATERAL @ 1.50% MIN. SLOPE 2. PROPOSED CLEANOUT 3. 8" FIRE PROTECTION LINE @ 5' MIN. DEPTH 4. CONNECT 8" FIRE PROTECTION LINE TO EXISTING WATER/FIRE PROTECTION LINE 5. PRE-CAST CONC. VAULT WITH PIV, FDC, DOUBLE CHECK VALVE FOR FIRE PROTECTION AND WATER METER FOR DOMESTIC WATER SERVICE 6. PROPOSED WATER VALVE 7. CONNECT EXIST. STORM SEWER PIPE(S) TO NEW STORM STRUCTURE. 8. DOWNSPOUT BOOT. CONNECT TO STORM SEWER MAINLINE WITH WYE CONNECTION. 9. 6" PVC ROOF DRAIN (COORDINATE LOCATION WITH M.E.P. PLANS) 10. 8" PVC ROOF DRAIN (COORDINATE LOCATION WITH M.E.P. PLANS) 11. EXISTING LIFT STATION 12. DRY SYSTEM FIRE PROTECTION (COORDINATE WITH M.E.P. PLANS) 13. PROPOSED NATURAL GAS LINE 14. NATURAL GAS SERVICE AND METER (COORDINATE WITH M.E.P. PLANS) 15. 4" DOMESTIC WATER SERVICE (COORDINATE WITH M.E.P. PLANS) 16. 6" FIRE PROTECTION SERVICE (COORDINATE WITH M.E.P. PLANS) 17. PROPOSED 6" FIRE HYDRANT AND VALVE ASSEMBLY 18. PROPOSED LIGHT POLE 19. PROPOSED LIGHT BOLLARD 20. 10" DUCTILE IRON PIPE @ 2.0% SLOPE FROM EXISTING LIFT STATION 21. 6" HDPE STORM LINE @ 1.0% MIN. SLOPE 22. 8" HDPE STORM LINE @ 3.0% MIN. SLOPE 23. 10" HDPE STORM LINE @ 1.0% MIN. SLOPE 24. PAVEMENT UNDERDRAIN 25. UNDERGROUND DETENTION SYSTEM, SEE DETAILS ON SHEET SU2.4 26. CONNECT 6" BUILDING UNDERDRAIN TO NEW 6" HDPE @ INVERT 817.98, COORDINATE WITH M.E.P. PLANS. 27. CONNECT (CORE DRILL) 6" HDPE TO NEW MANHOLE STRUCTURE @ INVERT 817.60 UTILITY LEGEND NEW STORM SEWER LINE NEW FIRE PROTECTION LINE NEW SANITARY LATERAL LINE NEW NATURAL GAS LINE EXISTING STORM LINE EXISTING WATER LINE EXISTING SANITARY LINE EXISTING ELECTRICAL LINE NEW UNDERDRAIN OR LOT 52 LOT 53 LOT 54 LOT 55 LO PROPOSED NATATORIUM BUILDING ADDITION F.F.E.= 831.98 F.F.E.= 831.98 F.F.E.= 834.65 LOT 52 LOT 53 LOT 54 LOT 55 LO FH1 FH4 G PROPOSED NATURAL GAS SERVICE LINE IS FROM EXISTING GAS MAIN LOCATED WITHIN MAIN STREET RIGHT-OF-WAY (SEE SHEET SU1.3 FOR MORE INFORMATION). COORDINATE WITH CENTERPOINT ENERGY. ST-401 RIM. = 832.72' INV. 826.02 (N) INV. 828.48 (E) INV. 827.65 (SW) ST-305 RIM. = 831.63' INV. 819.99 (S) INV. 819.53 (N) INV. 827.88 (W) INV. 820.88 (SW) ST-101 RIM. = 833.26' INV. 824.68 (E) ST-201 RIM. = 825.75' INV. 821.08 (N) INV. 821.58 (W) INV. 821.58 (SW) ST-102 RIM. = 828.00' INV. 823.58 (W) INV. 823.48 (NE) ST-202 RIM. = 824.34' INV. 820.34 (S) INV. 818.84 (E) INV. 820.34 (N) ST-203 RIM. = 823.45' INV. 818.74 (W) INV. 818.74 (E) ST-103 RIM. = 823.81' INV. 819.54 (SW) INV. 819.44 (N) RIM. = 823.73' INV. 815.32 (S) INV. 815.22 (N) ST-204 RIM. = 823.19' INV. 818.68 (W) INV. 816.98 (E) 4 5 1 3 3 4 13 13 15 16 6 19 2 EXISTING POOL UNDERDRAIN 11 14 19 17 8 10 9 20 2 INV.= 819.90 2 10 9 8 8 8 8 12 10" SAN. LATERAL INV.= 825.31 6" SAN. LATERAL INV.= 819.98 7 7 7 2 22 21 8 8 8 24 INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES SHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAY ALL CONSTRUCTION. THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES, SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUND CAUTION !! Know what's R Call 811 or 1-800-382-5544 Before You Begin Any Digging Project. Call 48 hours or 2 working days before you dig. It's Fast, It's Easy and It's the Law in the state of Indiana! 20 6002040 1. SEE DRAWING GD0.1 FOR GENERAL NOTES AND ADDITIONAL LEGEND. 2. TOPOGRAPHIC CONDITIONS AND EXISTING UTILITIES SHOWN WERE PROVIDED BY THE SURVEYOR. THE ENGINEER MAKES NO GUARANTEES THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. 3. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE PROJECT AREA INCLUDING UNDERGROUND UTILITY CONDITIONS, LOCATION AND DEPTH PRIOR TO ANY OTHER SITE CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER. 4. NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. 5. UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE DEVELOPERS RESPONSIBILITY TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED TO WITHIN ONE FOOT OF PROPOSED RIGHT-OF-WAY LINE. 6. DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL RESTORED/REPAIRED TO THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. 7. REFER TO UTILITY DETAILS ON SHEETS SU2.1, SU2.2, SU2.3, SU2.4, SU2.5 AND SU2.6 8. REFER TO STORM STRUCTURE TABLE ON SHEET SU2.3 GENERAL NOTES UTILITY LEGEND NEW STORM SEWER LINE NEW FIRE PROTECTION LINE NEW SANITARY LATERAL LINE NEW NATURAL GAS LINE EXISTING STORM LINE EXISTING WATER LINE EXISTING SANITARY LINE EXISTING ELECTRICAL LINE NEW UNDERDRAIN OR UTILITY KEYNOTES 1. 10" PVC SANITARY LATERAL @ 1.50% MIN. SLOPE 2. PROPOSED CLEANOUT 3. 8" FIRE PROTECTION LINE @ 5' MIN. DEPTH 4. CONNECT 8" FIRE PROTECTION LINE TO EXISTING WATER/FIRE PROTECTION LINE 5. PRE-CAST CONC. VAULT WITH PIV, FDC, DOUBLE CHECK VALVE FOR FIRE PROTECTION AND WATER METER FOR DOMESTIC WATER SERVICE 6. PROPOSED WATER VALVE 7. CONNECT EXIST. STORM SEWER PIPE(S) TO NEW STORM STRUCTURE. 8. DOWNSPOUT BOOT. CONNECT TO STORM SEWER MAINLINE WITH WYE CONNECTION. 9. 6" PVC ROOF DRAIN (COORDINATE LOCATION WITH M.E.P. PLANS) 10. 8" PVC ROOF DRAIN (COORDINATE LOCATION WITH M.E.P. PLANS) 11. EXISTING LIFT STATION 12. DRY SYSTEM FIRE PROTECTION (COORDINATE WITH M.E.P. PLANS) 13. PROPOSED NATURAL GAS LINE 14. NATURAL GAS SERVICE AND METER (COORDINATE WITH M.E.P. PLANS) 15. 4" DOMESTIC WATER SERVICE (COORDINATE WITH M.E.P. PLANS) 16. 6" FIRE PROTECTION SERVICE (COORDINATE WITH M.E.P. PLANS) 17. PROPOSED 6" FIRE HYDRANT AND VALVE ASSEMBLY 18. PROPOSED LIGHT POLE 19. PROPOSED LIGHT BOLLARD 20. 10" DUCTILE IRON PIPE @ 2.0% SLOPE FROM EXISTING LIFT STATION 21. 6" HDPE STORM LINE @ 1.0% MIN. SLOPE 22. 8" HDPE STORM LINE @ 3.0% MIN. SLOPE 23. 10" HDPE STORM LINE @ 1.0% MIN. SLOPE 24. PAVEMENT UNDERDRAIN 25. UNDERGROUND DETENTION SYSTEM, SEE DETAILS ON SHEET SU2.4 26. CONNECT 6" BUILDING UNDERDRAIN TO NEW 6" HDPE @ INVERT 817.98, COORDINATE WITH M.E.P. PLANS. 27. CONNECT (CORE DRILL) 6" HDPE TO NEW MANHOLE STRUCTURE @ INVERT 817.60 LOT 1 LOT 48 LOT 49 LOT 50 LOT 51 LOT 52 LOT 53 LOT 54 LOT 55 LOT 56 LOT 57 LOT 58 LOT 5 PROPOSED NATATORIUM BUILDING ADDITION F.F.E.= 831.98 F.F.E.= 831.98 F.F.E.= 831.98 F.F.E.= 834.65 FH1 FH4 G FH3 NATURAL GAS SERVICE. COORDINATE WITH M.E.P. PLANS FOR LOCATION. PROPOSED NATURAL GAS LINE. COORDINATE LOCATION AND INSTALLATION WITH CENTERPOINT ENERGY. PROPOSED NATURAL GAS LINE. COORDINATE LOCATION AND INSTALLATION WITH CENTERPOINT ENERGY. CONNECT PROPOSED NATURAL GAS LINE TO EXISTING GAS MAIN LOCATED WITH MAIN STREET RIGHT-OF-WAY. COORDINATE WITH CENTERPOINT ENERGY. EXISTING GAS MAIN 60 1800 60 120 INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES SHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAY ALL CONSTRUCTION. THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES, SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUND CAUTION !! Know what's R Call 811 or 1-800-382-5544 Before You Begin Any Digging Project. Call 48 hours or 2 working days before you dig. It's Fast, It's Easy and It's the Law in the state of Indiana! 1. SEE DRAWING GD0.1 FOR GENERAL NOTES AND ADDITIONAL LEGEND. 2. TOPOGRAPHIC CONDITIONS AND EXISTING UTILITIES SHOWN WERE PROVIDED BY THE SURVEYOR. THE ENGINEER MAKES NO GUARANTEES THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. 3. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE PROJECT AREA INCLUDING UNDERGROUND UTILITY CONDITIONS, LOCATION AND DEPTH PRIOR TO ANY OTHER SITE CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER. 4. NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. 5. UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE DEVELOPERS RESPONSIBILITY TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED TO WITHIN ONE FOOT OF PROPOSED RIGHT-OF-WAY LINE. 6. DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL RESTORED/REPAIRED TO THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. GENERAL NOTES UTILITY LEGEND NEW STORM SEWER LINE NEW FIRE PROTECTION LINE NEW SANITARY LATERAL LINE NEW NATURAL GAS LINE EXISTING STORM LINE EXISTING WATER LINE EXISTING SANITARY LINE EXISTING ELECTRICAL LINE EXISTING MASONRY WALL CONSTRUCTION TO REMAIN METAL COMPOSITE MATERIAL (MCM) WALL PANELS GLAZED ALUMINUM CURTAIN WALL ALUMINUM STOREFRONT FRAMING METAL COMPOSITE MATERIAL (MCM) WALL PANELS NORMAN BRICK -TYPE 1 COLOR A -1/3 RUNNING BOND GLAZED ALUMINUM CURTAIN WALL NORMAN BRICK -TYPE 1 COLOR A -1/3 RUNNING BOND CAST IN PLACE CONCRETE WITH FORMLINER FINISH65'-6"RELOCATE EXISTING BUILDING SIGNAGE TO NEW LOCATION RELOCATE EXISTING BUILDING SIGNAGE TO NEW LOCATION AHU SCREEN PANEL 8'-6"18'-8" 2'-6"12'-6" EXISTING SIGNAGE RELOCATED INSULATED TRANSLUCENT WALL PANEL SYSTEM EXISTING MASONRY WALL CONSTRUCTION TO REMAIN NORMAN BRICK -TYPE 1 COLOR A -1/3 RUNNING BOND UTILITY BRICK -TYPE 3 COLOR B -1/3 RUNNING BOND CAST IN PLACE CONCRETE WITH FORMLINER FINISH METAL COMPOSITE MATERIAL (MCM) WALL PANELS ADHERED THERMOPLASTIC MEMBRANE ROOFING SYSTEM METAL COPING TRANSLUCENT WALL PANEL SYSTEM HOLLOW GLASS BLOCK -COLOR B HOLLOW GLASS BLOCK -COLOR A 8"X8" BRICK -TYPE 4 COLOR A -STACK BOND BRICK UTILITY WATERTABLE COURSE -TYPE 5 COLOR B UTILITY BRICK -TYPE 3 COLOR B -1/3 RUNNING BOND METAL COPING NORMAN BRICK -TYPE 1 COLOR A -1/3 RUNNING BOND METAL COMPOSITE MATERIAL (MCM) WALL PANELS EXISTING CONSTRUCTION ADHERED THERMOPLASTIC MEMBRANE ROOFING SYSTEM METAL COPING METAL COMPOSITE MATERIAL (MCM) WALL PANELS NORMAN BRICK -TYPE 1 COLOR A -1/3 RUNNING BOND BRICK SOLDIER COURSE -TYPE 2 COLOR A BRICK (CUT) ROWLOCK COURSE -COLOR A (BUILDING INTERIOR) METAL COPING ADHERED THERMOPLASTIC MEMBRANE ROOFING SYSTEM NORMAN BRICK -TYPE 1 COLOR A -1/3 RUNNING BOND BRICK SOLDIER COURSE -TYPE 2 COLOR A BRICK (CUT) ROWLOCK COURSE -COLOR A CAST IN PLACE CONCRETE WITH FORMLINER FINISH TRANSLUCENT WALL PANEL SYSTEM GLAZED ALUMINUM CURTAIN WALL 17'-0"28'-4"12'-0"12'-0" CHANGEABLE SPORTS GRAPHIC PANELS 28'-4"17'-0" 12'-0"12'-0"NEW CONSTRUCTION RENOVATION COPYRIGHT 2021 BY FANNING/HOWEY ASSOCIATES, INC. WWW.FHAI.COM ARCHITECT PROJECT MANAGER: CS KEY PLAN 12/10/20218:11:35AMC:\Users\tvaughn\Documents\2019_ARCH_220014.00_tvaughn@fhai.com.rvtPROJECT NUMBER: 220014.00 CARMEL HIGH SCHOOL NATATORIUM ADDITION AND RENOVATIONS CARMEL CLAY SCHOOLS 520 E MAIN STREET CARMEL, IN 46032 BUILDING ELEVATIONS .A3.01 PROJECT ISSUE DATE: 12.10.2021 BZA SUBMITTAL DRAWN BY: TV 317.848.0966 350 E NEW YORK ST #300, INDIANAPOLIS, IN 46204 NORTHSCALE: 1/16" = 1'-0" NORTH ELEVATION SCALE: 3/64" = 1'-0" EAST ELEVATION SCALE: 1/16" = 1'-0" SOUTH ELEVATION - UNIT N2 SCALE: 1/16" = 1'-0" WEST ELEVATION REV. NO.DESCRIPTION DATE PROPOSED NATATORIUM BUILDING ADDITION F.F.E.= 831.98 F.F.E.= 831.98 F.F.E.= 831.98 F.F.E.= 834.65 Statistics Description Symbol Avg Max Min Max/Min Avg/Min EAST DRIVE/ NEW NORTH PARKING LOT 1.0 13.2 0.0 fc N/A N/A Schedule Symbol Label Quantity Manufacturer Catalog Number Description Lamp Number Lamps Lumens Per Lamp Wattage LS1/ 17 COOPER LIGHTING SOLUTIONS - INVUE (FORMERLY EATON) MSA-F06- LED-E1-T4 MESA DECORATIVE LED LUMINAIRE (6) LIGHTBARS WITH AccuLED OPTICS - TYPE 4 LED 42 285 156.5 LBP1 16 COOPER LIGHTING SOLUTIONS - INVUE (FORMERLY EATON) ABB-B2-LED- D1-S-8030 ARBOR OUTDOOR ARCHITECTURAL BOLLARD 80 CRI, 3000K LEDS AND SYMMETRIC OPTIC, GRAPHITE METALLIC PAINTED FINISH 1 1022 32LED LS2 F.F.E.= 834.65 Statistics Description Symbol Avg Max Min Max/Min Avg/Min WEST DRIVE 1.0 fc 15.6 fc 0.0 fc N/A N/A Schedule Symbol Label QTY Catalog Number Description Lamp Number Lamps Lumens per Lamp LLF Wattage LS1/ 19 MSA-F06-LED-E1-T4 MESA DECORATIVE LED LUMINAIRE (6) LIGHTBARS WITH AccuLED OPTICS - TYPE 4 LED 42 285 1 156.5 5 MSA-F06-LED-E1-T2 MESA DECORATIVE LED LUMINAIRE (6) LIGHTBARS WITH AccuLED OPTICS - TYPE 2 LED 42 290 1 156.5 LS2 LS1/ LS2 Statistics Description Symbol Avg Max Min Max/Min Avg/Min EXISTING SOUTH PARKING LOT 1.0 fc 7.1 fc 0.0 fc N/A N/A Schedule Symbol Label QTY Catalog Number Description Lamp Number Lamps Lumens per Lamp LLF Wattage MESA INVUE T4 22 MSA-F06-LED-E1-T4 MESA DECORATIVE LED LUMINAIRE (6) LIGHTBARS WITH AccuLED OPTICS - TYPE 4 LED 42 285 1 156.5 MESA INVUE T2 2 MSA-F06-LED-E1-T2 MESA DECORATIVE LED LUMINAIRE (6) LIGHTBARS WITH AccuLED OPTICS - TYPE 2 LED 42 290 1 156.5