Loading...
HomeMy WebLinkAboutJoist LayoutIndianapolis Design Center352 South County Road 300 EDanville, IN  46122317-745-9984These placement plans have been prepared with the specifications of TrussJoist products based on project information provided. This service is solely intended for product application assurance; and, is not intended to circumvent the needfor a design professional as determined by the building codes. The designer of record and/or builder/framer is responsible to assure these drawings are compatible with the overall project. These documents are not intended to replace the building plan (which should be used to determine bearing placement).Please insure measurements of the foundation match those provided at the timeof design.  Builder is responsible to place load bearing members in load path.Architectural Drawings Prepared By:Structural Drawings Prepared By:84 Lumber FranklinKevin BeherPyatt BuildersTG64ARev.ByDateDrawn By:DWChecked By:Date:12/16/2021Georgetown 2102384 Sheet 1 of 1 Second Floor System Not to Scale Confirm this layout with the builder and designer of record.  Make sure all discrepencies are corrected before ordering floor system. All Dimensions are Approximate and Must Be Field Verified. Framing Connector Summary PlotID Qty Manuf Product Design Method Face Nails Top Nails Member Nails Skew Slope Backer Blks Filler Web Stiff H202 6 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 -2- Strong-Grip --2 No No H203 6 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 -2- Strong-Grip --No No No H204 6 Simpson IUS2.37/11.88 Designed 10- 10dx1.5 -2- 10dx1.5 --No No Yes H205 4 Simpson IUS2.37/11.88 Designed 10- 10dx1.5 -2- Strong-Grip --No No No Products PlotID Length Product Plies Net Qty FJ201 12' 0" 11 7/8" TJI 110 joist 1 1 FJ202 6' 0" 11 7/8" TJI 110 joist 1 3 FJ203 4' 0" 11 7/8" TJI 110 joist 1 3 FJ204 2' 0" 11 7/8" TJI 110 joist 1 2 FJ205 30' 0" 11 7/8" TJI 360 joist 1 6 FJ206 20' 0" 11 7/8" TJI 360 joist 1 3 FJ207 18' 0" 11 7/8" TJI 360 joist 1 4 BM201 16' 0" 1 3/4" x 11 7/8" 2.0E Microllam LVL 4 4 BM202 10' 0" 1 3/4" x 9 1/2" 2.0E Microllam LVL 2 2 BM203 6' 0" 1 3/4" x 9 1/2" 2.0E Microllam LVL 2 2 BM204 22' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2 BM206 20' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2 BM205 20' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 1 BM207 14' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2 Ca201 16' 0" 1 1/8" x 11 7/8" TJ Rim Board 1 6  LEVEL NOTES  Current Date: 12/16/2021  File Name: tg64a_2102384.jvl  Level Name: Second Floor System  Building Code - Design Methodology: IBC 2012  Members with Design Overridden:  TJ-Pro Rating (Weighted Average): 37     Minimum Level TJ - Pro Rating & Joist: TJ-Pro rating = 35, joist = FJ206(i2251)     Maximum Level TJ - Pro Rating & Joist: TJ-Pro rating = 53, joist = FJ201(i2254)  FLOOR  Floor Container: FC1  Use/Occupancy: ResidentialLivingAreas  Floor Area Loading is: 40.0 lb/ft² Live Load & 10.0 lb/ft² Dead Load  Maximum Allowed Deflection: L/480 Live Load & L/240 Total Load  TJ-Pro Rating Information:      Weighted Average: 37      Directly Applied Ceiling: Varies      Decking Attachment: Glue and Nail      Decking Material: 23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF      Perpendicular Partition: No      Strapping at max 8' o.c.: None      Blocking at max 8' o.c.: No      Poured Flooring: No 11 7/8" TJI Joists 24" O.C. SpacingA3 A3 A3 H2 H2H2 H2 H2 H2 BM204 BM207BM206 BM205 BM203BM201BM202FJ203 FJ202 FJ207 FJ207 FJ207 FJ205 FJ205 FJ205 FJ205 FJ205 FJ205 FJ206 FJ206 FJ206 FJ201 Ca201 Ca201 Ca201 Ca201Ca201Ca201 Ca201 FJ203FJ203VO1 VO2 FJ207 FJ204FJ204H202H202Ca201 Ca201H203H203H203H2031' 0" 2' 0" 1' 0" 3' 7 1/8"2' 9 5/8" Ca201 H205 H204 H205 H204 H202 H205 H204 H204 H205 H204 H2043' 10 3/8"12' 0" 5' 1 3/4"1' 11 1/8"5' 0 7/8"2' 4 3/8"1' 3 1/8"1' 4"FJ202 FJ202 Ca201H202H203 H203 H202H202