Loading...
HomeMy WebLinkAboutM004.0Truss Connector Total List Manuf Product Qty MiTek JUS24 12 NA N/A 2 MiTek THD26-2 1 USP RT7A* 100 M01M01M04M06(4) M02 (2) M02(4) M03 (6) M05 (8) M07 (5) JUS24C03C01B02 B01 (2) JUS24 B04(7) JUS24A08A07A05A04A02A02A01B06 V04 V03 V02V01THD26-2 (2) C02(17) B03(2) A06 (4) A03(7) B0552-00-083-03-0855-04-001-04-0011-07-0024-07-0017-10-0055-04-008-09-08 8-10-08 5-04-00 12-10-00 35-10-00 13-07-08 22-02-08 35-10-00 11-07-08 2-00-001-04-0036-02-0014-06-08IMPORTANT THISDRAWINGISFORFIELD PLACEMENT OF INDIVIDUAL COMPONENTSONLY, AND DOESNOT CONSTITUTE AN ENGINEERED DOCUMENT. NOTE PROPER BEARINGANDBEARINGDESIGN INCLUDING ANCHORAGE, ISTHERESPONSIBILITY OF THE BUILDING DESIGNER, ARCHITECT AND /OR BUILDINGENGINEER. REFER TO INDIVIDUAL TRUSSDESIGNSFOR REACTIONS, MINIMUM REQUIRED BEARINGSIZE, UPLIFT, AND ADDITIONAL LOADS. 84COMPONENTSDOESNOT ASSUME RESPONSIBILITYIN THESE AREASOF CONCERN. BRACING ERECTION, TEMPORARY, AND PERMANENT BRACINGISTHE RESPONSIBILITY OFTHE CONTRACTOR AND / OR BUILDING DESIGNER. REFER TOINDIVIDUAL TRUSSDESIGNSFOR ADDITIONAL BRACINGREQUIREMENTS. REFERTO BCSI-B1 SUMMARY SHEET. THE STRUCTURAL BUILDINGCOMPONENTS ASSOCIATION COMMENTARY, AND RECOMMENDATIONSFOR HANDLING, INSTALLING&BRACINGMETALPLATECONNECTED WOOD TRUSSES. www.sbcindustry.com INSTALLATION DO NOT CUT, DRILL, OR ALTER TRUSSES. ANYQUESTIONS CALL 84COMPONENTS. PROPER INSTALLATION, AND HANDLINGOF COMPONENTSISTHE RESPONSIBILITY OF THE ERECTINGCONTRACTOR. 84COMPONENTSMUST BE NOTIFIED OF ANYPROBLEMS, AND AFFORDED THE OPPORTUNITY TO REVIEW, AND MAKE NECESSARY CORRECTIONS, OR NO BACK CHARGESWILL BE ACCEPTED ORAPPROVED. WARNING WARNINGS, AND INSTRUCTIONSFORERECTION OF COMPONENTSARE INCLUDED IN THE DELIVERY PACKAGE. KEEP THISINFORMATION ON THE JOB SITE. THESE DOCUMENTSWILLALSO BENEEDEDFORJOB SITE INSPECTION. MISUSE AND IMPROPER INSTALLATION OF COMPONENTSMAYRESULT IN FAILURE, BODILY INJURY, LOSS OFPROPERTY, AND / ORLIFE. RoofArea: Overhang Length: Eave Length: HipLength: ValleyLength: Ridge Length: SHEETNUMBER: R1.1 RoofTruss Placement Plan SCALE: NTS Job#: 2102383-2102383A PO#: Date: 12/7/2021 Drawn By: MM Designed By: MM Checked By: ROOF LOADS: TCLL: 20.0 lb/ft² TCDL: 10.0 lb/ft² BCLL: 0.0 lb/ft² BCDL:10.0 lb/ft² Building Code: IRC 2012 Wind Speed: 115 mph On-Center Spacing:24"U.N.O. 2107.75 SF 197.42 LF 130.3 LF 0 LF 44.03 LF 92.1 LF ROOF DATA THIS LAYOUTIS INTENDED FOR THE PURPOSE OF TRUSS LOCATION AND PLACEMENTONLY. REFER TO THE BUILDINGPLANS FOR ACTUAL BUILDING CONSTRUCTION.TG138Brown6939 Pickett PlaceCarmel, Indiana 46033ROOF TRUSS PLACEMENTPLAN2102383-2102383A1850 N Graham RoadFranklin, Indiana 46131Office:(317) 346-4274Fax: (317) 346-0916 01/12/22