HomeMy WebLinkAboutM004.0Truss Connector Total List
Manuf Product Qty
MiTek JUS24 12
NA N/A 2
MiTek THD26-2 1
USP RT7A* 100
M01M01M04M06(4) M02 (2) M02(4) M03
(6) M05
(8) M07
(5) JUS24C03C01B02
B01
(2) JUS24
B04(7) JUS24A08A07A05A04A02A02A01B06
V04
V03
V02V01THD26-2
(2) C02(17) B03(2) A06 (4) A03(7) B0552-00-083-03-0855-04-001-04-0011-07-0024-07-0017-10-0055-04-008-09-08 8-10-08 5-04-00 12-10-00
35-10-00
13-07-08 22-02-08
35-10-00
11-07-08
2-00-001-04-0036-02-0014-06-08IMPORTANT
THISDRAWINGISFORFIELD PLACEMENT OF INDIVIDUAL
COMPONENTSONLY, AND DOESNOT CONSTITUTE AN
ENGINEERED DOCUMENT.
NOTE
PROPER BEARINGANDBEARINGDESIGN INCLUDING
ANCHORAGE, ISTHERESPONSIBILITY OF THE BUILDING
DESIGNER, ARCHITECT AND /OR BUILDINGENGINEER. REFER
TO INDIVIDUAL TRUSSDESIGNSFOR REACTIONS, MINIMUM
REQUIRED BEARINGSIZE, UPLIFT, AND ADDITIONAL LOADS.
84COMPONENTSDOESNOT ASSUME RESPONSIBILITYIN
THESE AREASOF CONCERN.
BRACING
ERECTION, TEMPORARY, AND PERMANENT BRACINGISTHE
RESPONSIBILITY OFTHE CONTRACTOR AND / OR BUILDING
DESIGNER. REFER TOINDIVIDUAL TRUSSDESIGNSFOR
ADDITIONAL BRACINGREQUIREMENTS. REFERTO BCSI-B1
SUMMARY SHEET. THE STRUCTURAL BUILDINGCOMPONENTS
ASSOCIATION COMMENTARY, AND RECOMMENDATIONSFOR
HANDLING, INSTALLING&BRACINGMETALPLATECONNECTED
WOOD TRUSSES. www.sbcindustry.com
INSTALLATION
DO NOT CUT, DRILL, OR ALTER TRUSSES. ANYQUESTIONS
CALL 84COMPONENTS. PROPER INSTALLATION, AND
HANDLINGOF COMPONENTSISTHE RESPONSIBILITY OF THE
ERECTINGCONTRACTOR. 84COMPONENTSMUST BE
NOTIFIED OF ANYPROBLEMS, AND AFFORDED THE
OPPORTUNITY TO REVIEW, AND MAKE NECESSARY
CORRECTIONS, OR NO BACK CHARGESWILL BE ACCEPTED
ORAPPROVED.
WARNING
WARNINGS, AND INSTRUCTIONSFORERECTION
OF COMPONENTSARE INCLUDED IN THE DELIVERY PACKAGE.
KEEP THISINFORMATION ON THE JOB SITE. THESE
DOCUMENTSWILLALSO BENEEDEDFORJOB SITE
INSPECTION. MISUSE AND IMPROPER INSTALLATION OF
COMPONENTSMAYRESULT IN FAILURE, BODILY INJURY, LOSS
OFPROPERTY, AND / ORLIFE.
RoofArea:
Overhang Length:
Eave Length:
HipLength:
ValleyLength:
Ridge Length:
SHEETNUMBER:
R1.1
RoofTruss
Placement Plan
SCALE: NTS
Job#:
2102383-2102383A
PO#:
Date: 12/7/2021
Drawn By: MM
Designed By: MM
Checked By:
ROOF LOADS:
TCLL: 20.0 lb/ft²
TCDL: 10.0 lb/ft²
BCLL: 0.0 lb/ft²
BCDL:10.0 lb/ft²
Building Code: IRC 2012
Wind Speed: 115 mph
On-Center Spacing:24"U.N.O.
2107.75 SF
197.42 LF
130.3 LF
0 LF
44.03 LF
92.1 LF
ROOF DATA
THIS LAYOUTIS INTENDED FOR THE PURPOSE OF TRUSS LOCATION AND PLACEMENTONLY. REFER TO THE BUILDINGPLANS FOR ACTUAL BUILDING CONSTRUCTION.TG138Brown6939 Pickett PlaceCarmel, Indiana 46033ROOF TRUSS PLACEMENTPLAN2102383-2102383A1850 N Graham RoadFranklin, Indiana 46131Office:(317) 346-4274Fax: (317) 346-0916
01/12/22