HomeMy WebLinkAboutM002.0Indianapolis Design Center352 South County Road 300 EDanville, IN 46122317-745-9984These placement plans have been prepared with the specifications of TrussJoist products based on project information provided. This service is solely intendedfor product application assurance; and, is not intended to circumvent the needfor a design professional as determined by the building codes. The designerof record and/or builder/framer is responsible to assure these drawings arecompatible with the overall project. These documents are not intended to replacethe building plan (which should be used to determine bearing placement).Please insure measurements of the foundation match those provided at the timeof design. Builder is responsible to place load bearing members in load path.Architectural Drawings Prepared By: Structural Drawings Prepared By: 84 Lumber FranklinKevin BeherPyatt BuildersLost 182ARev. By Date CommentsDrawn By:JRChecked By: Date:DW 11/12/2021Stockbridge
2102182
Sheet
1 of 1
Main Floor System
Confirm this layout with the builder and designer of record. Make
sure all discrepencies are corrected before ordering floor system.
All Dimensions are Approximate and Must Be Field Verified. BBO1BBO2
Framing Connector Summary
PlotID Qty Manuf Product Design Method Face Nails Top Nails Member Nails Skew Slope Backer Blks Filler Web Stiff
H1 1 Simpson HGUS5.50/10 Designed 46- 10d - 16- 10d - - No No No
H2 9 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 - 2- 10dx1.5 - - No No Yes
H3 1 Simpson MIU2.37/11 Designed 20- 10dx1.5 - 2- 10dx1.5 - - No No No
H5 5 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 - 2- Strong-Grip - - No No No
Products
PlotID Length Product Plies Net Qty
FJ101 18' 0" 11 7/8" TJI 110 joist 1 7
FJ102 16' 0" 11 7/8" TJI 110 joist 1 3
FJ103 14' 0" 11 7/8" TJI 110 joist 1 7
FJ104 18' 0" 11 7/8" TJI 360 joist 1 1
BM101 20' 0" 1 3/4" x 14" 2.0E Microllam LVL 3 3
BM102 10' 0" 1 3/4" x 9 1/2" 2.0E Microllam LVL 2 2
BM103 22' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2
BM104 18' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 3 3
BM105 12' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 1
Ca101 16' 0" 1 1/8" x 11 7/8" TJ Rim Board 1 4
LEVEL NOTES
Current Date: 11/17/2021
File Name: tg182a.jvl
Level Name: Second Floor System
Building Code - Design Methodology: IBC 2006
Members with Design Overridden:
TJ-Pro Rating (Weighted Average): Unable to Calculate
Minimum Level TJ - Pro Rating & Joist: Unable to Calculate
Maximum Level TJ - Pro Rating & Joist: Unable to Calculate
FLOOR
Floor Container: FC1
Use/Occupancy: ResidentialLivingAreas
Floor Area Loading is: 30.0 lb/ft² Live Load & 10.0 lb/ft² Dead Load
Floor Maximum Allowed Deflection L/480 Live Load & L/240 Total Load
TJ-Pro Rating Information:
Weighted Average: Unable to Calculate
Directly Applied Ceiling: Gypsum 1/2"
Decking Attachment: Glue and Nail
Decking Material: 23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF
Perpendicular Partition: No
Strapping at max 8' o.c.: None
Blocking at max 8' o.c.: No
Poured Flooring: No
A3
A3
A3
A3
A3 BM105BM104
FJ103
FJ103
FJ103
FJ103
FJ103
FJ103
FJ103
FJ102
FJ102
FJ104
FJ101
FJ101
FJ101
FJ101
FJ101
FJ101
FJ102
Ca101
Ca101Ca101Ca101Ca101 Ca101Ca101 VO3
VO4
FJ101 Ca102 Ca102Ca102Ca102 Ca102 Ca102 Ca102 Ca102Ca102 1' 0"2' 0" 1' 0" 7 1/16"10 9/16"BM103
BM102Ca101 BM101Ca102 H1H2
H2
H2
H2
H2
H2
H2
H2
H5
H5 H2
H5
H5
H5
H3
01/12/22