Loading...
HomeMy WebLinkAboutM002.0Indianapolis Design Center352 South County Road 300 EDanville, IN  46122317-745-9984These placement plans have been prepared with the specifications of TrussJoist products based on project information provided. This service is solely intendedfor product application assurance; and, is not intended to circumvent the needfor a design professional as determined by the building codes. The designerof record and/or builder/framer is responsible to assure these drawings arecompatible with the overall project. These documents are not intended to replacethe building plan (which should be used to determine bearing placement).Please insure measurements of the foundation match those provided at the timeof design.  Builder is responsible to place load bearing members in load path.Architectural Drawings Prepared By: Structural Drawings Prepared By: 84 Lumber FranklinKevin BeherPyatt BuildersLost 182ARev. By Date CommentsDrawn By:JRChecked By: Date:DW 11/12/2021Stockbridge 2102182 Sheet 1 of 1 Main Floor System Confirm this layout with the builder and designer of record.  Make sure all discrepencies are corrected before ordering floor system. All Dimensions are Approximate and Must Be Field Verified. BBO1BBO2 Framing Connector Summary PlotID Qty Manuf Product Design Method Face Nails Top Nails Member Nails Skew Slope Backer Blks Filler Web Stiff H1 1 Simpson HGUS5.50/10 Designed 46- 10d - 16- 10d - - No No No H2 9 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 - 2- 10dx1.5 - - No No Yes H3 1 Simpson MIU2.37/11 Designed 20- 10dx1.5 - 2- 10dx1.5 - - No No No H5 5 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 - 2- Strong-Grip - - No No No Products PlotID Length Product Plies Net Qty FJ101 18' 0" 11 7/8" TJI 110 joist 1 7 FJ102 16' 0" 11 7/8" TJI 110 joist 1 3 FJ103 14' 0" 11 7/8" TJI 110 joist 1 7 FJ104 18' 0" 11 7/8" TJI 360 joist 1 1 BM101 20' 0" 1 3/4" x 14" 2.0E Microllam LVL 3 3 BM102 10' 0" 1 3/4" x 9 1/2" 2.0E Microllam LVL 2 2 BM103 22' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2 BM104 18' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 3 3 BM105 12' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 1 Ca101 16' 0" 1 1/8" x 11 7/8" TJ Rim Board 1 4   LEVEL NOTES   Current Date:   11/17/2021   File Name:   tg182a.jvl   Level Name:   Second Floor System   Building Code - Design Methodology:   IBC 2006   Members with Design Overridden:   TJ-Pro Rating (Weighted Average):   Unable to Calculate         Minimum Level TJ - Pro Rating & Joist:   Unable to Calculate         Maximum Level TJ - Pro Rating & Joist:   Unable to Calculate   FLOOR   Floor Container:   FC1   Use/Occupancy:   ResidentialLivingAreas   Floor Area Loading is:   30.0 lb/ft² Live Load & 10.0 lb/ft² Dead Load Floor Maximum Allowed Deflection   L/480 Live Load & L/240 Total Load   TJ-Pro Rating Information:           Weighted Average:   Unable to Calculate           Directly Applied Ceiling:   Gypsum 1/2"           Decking Attachment:   Glue and Nail           Decking Material:   23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF           Perpendicular Partition:   No           Strapping at max 8' o.c.:   None           Blocking at max 8' o.c.:   No           Poured Flooring:   No A3 A3 A3 A3 A3 BM105BM104 FJ103 FJ103 FJ103 FJ103 FJ103 FJ103 FJ103 FJ102 FJ102 FJ104 FJ101 FJ101 FJ101 FJ101 FJ101 FJ101 FJ102 Ca101 Ca101Ca101Ca101Ca101 Ca101Ca101 VO3 VO4 FJ101 Ca102 Ca102Ca102Ca102 Ca102 Ca102 Ca102 Ca102Ca102 1' 0"2' 0" 1' 0" 7 1/16"10 9/16"BM103 BM102Ca101 BM101Ca102 H1H2 H2 H2 H2 H2 H2 H2 H2 H5 H5 H2 H5 H5 H5 H3 01/12/22