Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20LV - Truss Seal
16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by 84 Components - 0783. December 22,2021 Liu, Xuegang Pages or sheets covered by this seal: I49388941 thru I49389007 My license renewal date for the state of Indiana is July 31, 2022. 2102440 WILSON RESIDENCE - 20LV IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use,the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss A01 Truss Type Piggyback Base Supported Gable Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388941 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:05:37 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-DCfUI79Gd4YylkmKubL_vr3ENT0nprkdUtBvzIy6gqy Scale = 1:74.7 1 23 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 45 46 47 3x6 3x6 3x6 3x4 3x4 3x6 3x6 6x6 40-11-8 40-11-8 20-4-13 20-4-13 26-2-0 5-9-3 40-11-8 14-9-8 0-0-86-10-211-2-04.00 12 9.00 12 Plate Offsets (X,Y)-- [15:0-3-0,0-0-1], [23:Edge,0-1-8], [24:Edge,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.45 0.17 0.15 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.01 (loc) - - 24 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 252 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 15-23. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 23-24, 22-25, 21-26, 20-27, 19-28, 18-29, 17-30, 16-31, 14-33, 13-34 REACTIONS.All bearings 40-11-8. (lb) - Max Horz 1=294(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 24, 25, 26, 27, 30, 31, 33, 34, 35, 36, 37, 39, 40, 41, 42, 43, 44 Max Grav All reactions 250 lb or less at joint(s) 24, 1, 31, 35, 36, 37, 39, 40, 41, 42, 43 except 25=272(LC 36), 26=262(LC 36), 27=261(LC 36), 28=261(LC 36), 29=261(LC 36), 30=266(LC 36), 33=251(LC 37), 34=271(LC 37), 44=344(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-417/282, 2-4=-370/251, 4-5=-352/253, 5-6=-328/242, 6-7=-305/235, 7-8=-281/226, 8-9=-258/219 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=41ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3) 0-9-5 to 4-11-8, Exterior(2) 4-11-8 to 26-2-0, Corner(3) 26-2-0 to 30-3-2, Exterior(2) 30-3-2 to 40-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) Unbalanced snow loads have been considered for this design. 6) Provide adequate drainage to prevent water ponding. 7) All plates are 1.5x4 MT20 unless otherwise indicated. 8) Gable requires continuous bottom chord bearing. 9) Gable studs spaced at 2-0-0 oc. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 24, 25, 26, 27, 30, 31, 33, 34, 35, 36, 37, 39, 40, 41, 42, 43, 44. 13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss A02 Truss Type Piggyback Base Qty 10 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388942 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:05:40 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-dnLdw9C8w?wXcCVvZjvhXUhi9gzz03Z3ArPZacy6gqv Scale = 1:78.3 1 2 3 4 5 6 7 8 9 17 16 15 14 13 12 11 10 18 19 20 21 22 23 24 25 26 27 28 3x6 6x6 6x6 3x4 3x6 3x6 1.5x4 3x4 3x4 4x4 4x4 3x4 3x4 6x8 6x6 3x6 6-5-6 6-5-6 12-1-12 5-8-6 20-3-2 8-1-6 25-8-3 5-5-0 33-3-13 7-7-11 40-11-8 7-7-11 -1-2-8 1-2-8 7-3-1 7-3-1 13-9-2 6-6-1 20-3-2 6-6-1 25-8-3 5-5-0 33-3-13 7-7-11 40-11-8 7-7-11 0-4-37-1-411-2-04.00 12 9.00 12 Plate Offsets (X,Y)-- [7:0-3-0,0-2-2], [10:Edge,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.67 0.46 0.66 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.12 -0.20 0.01 (loc) 10-11 10-11 10 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 221 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E *Except* 7-9: 2x6 SP 2400F 2.0E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 *Except* 9-10: 2x4 SPF 1650F 1.5E BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 7-9. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 9-10, 6-13, 7-11, 8-11 REACTIONS. (size)10=0-3-8, 2=0-10-0, 16=0-3-8 Max Horz 2=296(LC 15) Max Uplift 10=-5(LC 13), 2=-25(LC 16) Max Grav 10=1552(LC 45), 2=374(LC 40), 16=1913(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-5=-216/711, 5-6=-955/88, 6-7=-1095/145, 7-8=-836/147, 8-9=-835/146, 9-10=-1483/125 BOT CHORD 13-14=-162/895, 11-13=-159/867 WEBS 3-17=0/255, 3-16=-722/62, 5-16=-1537/108, 5-14=0/1116, 6-14=-487/80, 7-13=0/396, 7-11=-316/64, 8-11=-1009/146, 9-11=-101/1409 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=41ft; eave=5ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-2-8 to 2-10-10, Interior(1) 2-10-10 to 25-8-3, Exterior(2) 25-8-3 to 29-9-5, Interior(1) 29-9-5 to 40-9-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) Provide adequate drainage to prevent water ponding. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 2. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss B01 Truss Type Piggyback Base Qty 2 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388943 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:05:42 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-Z9SNLrDOSdAFrWfHh8x9cvm2NUh_UvlMe9ugeVy6gqt Scale = 1:110.7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 26 25 24 23 22 21 20 19 18 17 16 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 3x6 8x8 6x8 4x6 6x6 4x6 4x6 4x6 3x4 6x6 6x6 6x6 6x6 4x6 3x4 6x8 3x4 6x8 6x8 6x8 3x4 6x8 4x6 4x6 6-5-6 6-5-6 12-1-12 5-8-6 20-3-2 8-1-6 25-8-3 5-5-0 33-4-5 7-8-2 40-10-11 7-6-6 48-6-13 7-8-2 55-3-3 6-8-5 62-3-0 6-11-13 -1-2-8 1-2-8 7-3-1 7-3-1 13-9-2 6-6-1 20-3-2 6-6-1 25-8-3 5-5-0 33-4-5 7-8-2 40-10-11 7-6-6 48-6-13 7-8-2 55-3-3 6-8-5 62-3-0 6-11-13 63-5-8 1-2-8 0-4-37-1-411-2-00-10-1411-2-04.00 12 9.00 12 Plate Offsets (X,Y)-- [6:0-4-0,0-3-0], [7:0-5-8,0-3-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.69 0.29 0.93 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.14 -0.24 0.07 (loc) 19-20 19-20 14 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 430 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x6 SP 2400F 2.0E *Except* 4-6,1-4: 2x4 SPF 1650F 1.5E BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF No.2 WEDGE Right: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-9-15 oc purlins, except 2-0-0 oc purlins (5-9-2 max.): 7-11. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 5-25, 6-22, 7-22, 8-20, 10-20, 10-17, 13-17 REACTIONS. (size)2=0-10-0, 25=0-3-8, 14=0-3-8 Max Horz 2=202(LC 15) Max Uplift 2=-35(LC 16) Max Grav 2=330(LC 42), 25=2898(LC 24), 14=2238(LC 51) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-98/506, 3-5=-5/1011, 5-6=-2045/123, 6-7=-2596/194, 7-8=-2792/212, 8-10=-2790/212, 10-11=-2265/200, 11-13=-2841/200, 13-14=-3140/124 BOT CHORD 2-26=-514/71, 25-26=-559/47, 22-23=0/2029, 20-22=0/2142, 19-20=0/2872, 17-19=0/2872, 16-17=-0/2356, 14-16=-0/2356 WEBS 3-26=0/254, 3-25=-843/76, 5-25=-2651/121, 5-23=-8/2338, 6-23=-1221/90, 7-22=-16/298, 7-20=-37/1261, 8-20=-806/125, 10-19=0/425, 10-17=-1139/38, 11-17=-7/1224, 13-17=-660/112, 13-16=0/283 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=62ft; eave=7ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-2-8 to 5-0-3, Interior(1) 5-0-3 to 25-8-3, Exterior(2) 25-8-3 to 31-10-14, Interior(1) 31-10-14 to 48-6-13, Exterior(2) 48-6-13 to 54-9-9, Interior(1) 54-9-9 to 63-5-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) WARNING: This long span truss requires extreme care and experience for proper and safe handling and erection. For general handling and erection guidance, see Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses ("BCSI"), jointly produced by SBCA and TPI. The building owner or the owner’s authorized agent shall contract with a qualified registered design professional for the design and inspection of the temporary installation restraint/bracing and the permanent individual truss member restraint/bracing. MiTek assumes no responsibility for truss manufacture, handling, erection, or bracing. 7) Provide adequate drainage to prevent water ponding. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. Continued on page 2 December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss B01 Truss Type Piggyback Base Qty 2 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388943 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:05:43 2021 Page 2 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-1M0mZBE1DwI6TfDTFrSO96JD7t1DDM?VspeDBxy6gqs NOTES- 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss C01 Truss Type Roof Special Qty 4 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388944 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:05:44 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-VYa8mXFf_EQz4pogoZzdhKsPoHNSywkf5SNnjOy6gqr Scale = 1:57.4 1 2 3 4 5 6 7 12 11 10 9 8 13 14 15 16 6x6 3x6 1.5x4 6-5-6 6-5-6 12-1-12 5-8-6 20-3-2 8-1-6 26-3-15 6-0-12 -1-2-8 1-2-8 7-3-1 7-3-1 13-9-2 6-6-1 20-3-2 6-6-1 26-3-15 6-0-12 0-4-37-1-411-7-134.00 12 9.00 12 Plate Offsets (X,Y)-- [7:0-0-12,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.57 0.29 0.46 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.07 -0.13 0.01 (loc) 9-10 9-10 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 117 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 9-10. WEBS 1 Row at midpt 7-8, 6-8 REACTIONS. (size)8=Mechanical, 2=0-10-0, 10=0-3-8 Max Horz 2=310(LC 15) Max Uplift 8=-32(LC 13), 2=-23(LC 16) Max Grav 8=529(LC 21), 2=443(LC 1), 10=1453(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-460/17, 3-5=-218/448, 5-6=-412/82 BOT CHORD 2-12=-185/382, 10-12=-209/338, 8-9=-85/291 WEBS 3-12=0/258, 3-10=-716/61, 5-10=-1058/60, 5-9=0/361, 6-8=-435/83 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=26ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 26-2-3 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are 3x4 MT20 unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 2. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss C02 Truss Type Monopitch Qty 2 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388945 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:05:45 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-_k8WzsFHlYYpizNsMGUsEXOZjhighOHoK67KFqy6gqq Scale = 1:63.0 1 2 3 4 7 6 5 89 10 11 12 13 1.5x4 6x6 3x4 3x6 3x4 3x4 3x6 8-3-2 8-3-2 14-3-15 6-0-12 4-3-5 4-3-5 8-3-2 3-11-13 14-3-15 6-0-12 4-4-37-1-411-7-134.00 12 9.00 12 Plate Offsets (X,Y)-- [4:0-0-12,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.62 0.36 0.44 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.10 -0.20 0.01 (loc) 6-7 6-7 5 l/defl >999 >860 n/a L/d 240 180 n/a PLATES MT20 Weight: 84 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-5, 3-5 REACTIONS. (size)5=Mechanical, 7=Mechanical Max Horz 7=298(LC 15) Max Uplift 5=-64(LC 13) Max Grav 5=638(LC 23), 7=621(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-464/77 BOT CHORD 6-7=-273/446, 5-6=-159/390 WEBS 3-6=-37/257, 3-5=-540/98, 2-7=-549/100 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 14-2-3 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss C03 Truss Type Monopitch Qty 8 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388946 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:05:45 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-_k8WzsFHlYYpizNsMGUsEXOZbhi1hRCoK67KFqy6gqq Scale = 1:63.0 1 2 3 4 5 7 6 8 9 10 11 3x4 3x4 3x6 3x8 MT18HS 4x4 4x4 3x6 1.5x4 7-1-15 7-1-15 14-3-15 7-1-15 7-1-15 7-1-15 14-3-15 7-1-15 0-10-1411-7-139.00 12 Plate Offsets (X,Y)-- [1:0-6-0,0-0-1], [5:0-0-12,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.63 0.34 0.25 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.06 -0.11 0.01 (loc) 6-7 6-7 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 77 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 SLIDER Left 2x6 SP 2400F 2.0E 4-6-7 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-6, 3-6 REACTIONS. (size)6=Mechanical, 1=Mechanical Max Horz 1=306(LC 11) Max Uplift 6=-63(LC 11) Max Grav 6=667(LC 19), 1=628(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-752/70 BOT CHORD 1-7=-190/523, 6-7=-190/523 WEBS 3-7=0/361, 3-6=-644/127 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 14-2-3 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss C04 Truss Type Monopitch Supported Gable Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388947 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:05:46 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-SxiuBCGvWrggK7y2w_?5mlxkt543Qv?yZmsunGy6gqp Scale = 1:62.2 1 2 3 4 5 6 7 8 15 14 13 12 11 10 9 6x6 4x6 4x4 6x6 14-3-15 14-3-15 14-3-15 14-3-15 0-6-811-3-79.00 12 Plate Offsets (X,Y)-- [8:0-4-0,Edge], [9:Edge,0-3-8] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.59 0.22 0.15 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 9 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 87 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 1-15. WEBS 1 Row at midpt 8-9, 7-10 REACTIONS.All bearings 14-3-15. (lb) - Max Horz 1=296(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 9, 1, 10, 11, 12, 13, 14, 15 Max Grav All reactions 250 lb or less at joint(s) 9, 1, 10, 11, 12, 13, 14, 15 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-507/494, 2-3=-412/403, 3-4=-361/364, 4-5=-305/317, 5-6=-249/271 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3) 0-0-0 to 3-0-0, Exterior(2) 3-0-0 to 14-2-3 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) All plates are 1.5x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 1, 10, 11, 12, 13, 14, 15. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss D01 Truss Type GABLE Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388948 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:05:48 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-OJqfcuI91TwOZR6R1P2ZsA0C8unfuq_E04L_s9y6gqn Scale = 1:63.3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 29 28 27 26 25 24 23 22 21 20 19 18 17 16 30 31 3x4 3x4 3x4 3x4 3x4 3x4 3x6 21-11-0 21-11-0 8-1-9 8-1-9 13-9-7 5-7-14 21-11-0 8-1-9 1-0-310-6-01-0-310-6-014.00 12 Plate Offsets (X,Y)-- [6:0-1-5,Edge], [10:0-1-5,Edge] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.09 0.08 0.12 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 16 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 145 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 6-10. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 8-22, 7-23, 5-24, 9-21, 11-20 REACTIONS.All bearings 21-11-0. (lb) - Max Horz 29=-202(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 29, 22, 24, 26, 28, 19, 18 except 16=-157(LC 13), 27=-134(LC 14), 17=-185(LC 14) Max Grav All reactions 250 lb or less at joint(s) 29, 16, 22, 23, 24, 26, 27, 28, 21, 20, 19, 18, 17 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3) 0-1-12 to 2-11-8, Exterior(2) 2-11-8 to 8-1-9, Corner(3) 8-1-9 to 10-11-8, Exterior(2) 10-11-8 to 13-9-7, Corner(3) 13-9-7 to 16-11-8, Exterior(2) 16-11-8 to 21-9-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) Provide adequate drainage to prevent water ponding. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 9) Gable studs spaced at 2-0-0 oc. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 29, 22, 24, 26, 28, 19, 18 except (jt=lb) 16=157, 27=134, 17=185. 13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss D02 Truss Type Piggyback Base Qty 5 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388949 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:05:49 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-sVN1pEJoom2FBahdb6ZoONZJmI4UdHvOFk5YOby6gqm Scale = 1:59.8 1 2 3 4 5 10 9 8 7 6 11 12 13 14 15 16 17 18 19 6x6 6x6 3x4 3x4 4x4 6x8 6x6 3x4 6x6 7-8-15 7-8-15 14-2-1 6-5-2 21-11-0 7-8-15 -1-2-8 1-2-8 7-8-15 7-8-15 14-2-1 6-5-2 21-11-0 7-8-15 1-5-910-6-01-5-910-6-014.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-8], [3:0-2-12,0-1-8], [4:0-3-0,0-1-12], [5:0-3-4,0-2-0], [6:Edge,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.36 0.30 0.08 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.09 -0.18 0.01 (loc) 9-10 9-10 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 149 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x6 SP 2400F 2.0E *Except* 3-4: 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-7 REACTIONS. (size)10=0-3-8, 6=0-3-8 Max Horz 10=220(LC 13) Max Uplift 10=-14(LC 14) Max Grav 10=949(LC 1), 6=864(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-864/106, 3-4=-464/157, 4-5=-859/99, 2-10=-870/126, 5-6=-786/86 BOT CHORD 9-10=-173/366, 7-9=-4/528 WEBS 3-9=0/260, 4-7=0/257, 2-9=-63/372, 5-7=-9/374 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 7-8-15, Exterior(2) 7-8-15 to 11-11-14, Interior(1) 11-11-14 to 14-2-1, Exterior(2) 14-2-1 to 18-4-15, Interior(1) 18-4-15 to 21-9-9 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss D03 Truss Type Piggyback Base Girder Qty 1 Ply 2 WILSON RESIDENCE - 20LV Job Reference (optional) I49388950 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:05:52 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-G439RGLg5hRq22PCGE6V00BteW8QqbgqxiJC?wy6gqj Scale = 1:59.7 1 2 3 4 5 6 7 15 14 13 12 11 10 9 8 16 17 18 19 20 21 22 4x6 6x6 6x6 4x6 3x4 4x6 3x6 4x4 3x4 3x8 MT18HS 1.5x4 3x4 3x6 4x4 3x4 4-0-4 4-0-4 7-8-15 3-8-12 10-11-8 3-2-9 14-2-1 3-2-9 17-10-12 3-8-12 21-11-0 4-0-4 4-0-4 4-0-4 7-8-15 3-8-12 10-11-8 3-2-9 14-2-1 3-2-9 17-10-12 3-8-12 21-11-0 4-0-4 1-5-910-6-01-5-910-6-014.00 12 Plate Offsets (X,Y)-- [3:0-3-0,0-1-8], [5:0-3-0,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.19 0.16 0.27 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.06 0.01 (loc) 9-10 9-10 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 361 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)15=0-3-8, 8=0-3-8 Max Horz 15=-202(LC 8) Max Grav 15=3606(LC 1), 8=3703(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-3465/0, 2-3=-3004/0, 3-4=-2086/0, 4-5=-2086/0, 5-6=-3019/0, 6-7=-3519/0, 1-15=-3301/0, 7-8=-3350/0 BOT CHORD 14-15=-152/298, 12-14=0/2211, 11-12=0/1908, 10-11=0/1919, 9-10=0/2234 WEBS 2-14=0/629, 2-12=-598/0, 3-12=0/1454, 3-11=0/620, 5-11=0/616, 5-10=0/1480, 6-10=-599/0, 6-9=0/637, 1-14=0/2133, 7-9=0/2161 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 6) Provide adequate drainage to prevent water ponding. 7) All plates are MT20 plates unless otherwise indicated. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 558 lb down at 2-0-4, 558 lb down at 4-0-4, 558 lb down at 6-0-4, 558 lb down at 8-0-4, 558 lb down at 10-0-4, 558 lb down at 12-0-4, 558 lb down at 14-0-4, 558 lb down at 16-0-4, and 601 lb down at 18-0-4, and 601 lb down at 20-0-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. Continued on page 2 December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss D03 Truss Type Piggyback Base Girder Qty 1 Ply 2 WILSON RESIDENCE - 20LV Job Reference (optional) I49388950 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:05:52 2021 Page 2 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-G439RGLg5hRq22PCGE6V00BteW8QqbgqxiJC?wy6gqj LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-5=-60, 5-7=-60, 8-15=-20 Concentrated Loads (lb) Vert: 13=-547(F) 14=-547(F) 12=-547(F) 10=-547(F) 9=-601(F) 18=-547(F) 19=-547(F) 20=-547(F) 21=-547(F) 22=-601(F) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss E01 Truss Type GABLE Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388951 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:05:53 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-lHdYfcMIs?ZhgC_OqydkZDj3KvWTZ4RzAM3lXMy6gqi Scale: 3/16"=1' 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 29 28 27 26 25 24 23 22 21 20 19 18 17 16 4x6 4x6 3x4 3x4 3x6 21-3-0 21-3-0 6-5-0 6-5-0 14-10-0 8-5-0 21-3-0 6-5-0 3-0-310-6-03-0-310-6-014.00 12 Plate Offsets (X,Y)-- [5:0-4-8,0-1-12], [11:0-4-8,0-1-12] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.07 0.04 0.17 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 16 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 161 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 5-11. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 8-22, 7-23, 6-24, 9-21, 10-20 REACTIONS.All bearings 21-3-0. (lb) - Max Horz 29=-214(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 16, 22, 23, 24, 26, 21, 20, 19, 18 except 29=-106(LC 12), 27=-200(LC 11), 28=-207(LC 12), 17=-115(LC 14) Max Grav All reactions 250 lb or less at joint(s) 29, 16, 22, 23, 24, 26, 21, 20, 19, 18, 17 except 27=380(LC 12), 28=352(LC 13) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 4-5=-270/310, 11-12=-271/311 WEBS 2-28=-351/288, 2-27=-307/302 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3) 0-1-12 to 3-1-12, Exterior(2) 3-1-12 to 6-5-0, Corner(3) 6-5-0 to 9-5-0, Exterior(2) 9-5-0 to 14-10-0, Corner(3) 14-10-0 to 17-10-0, Exterior(2) 17-10-0 to 21-1-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) Provide adequate drainage to prevent water ponding. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 9) Gable studs spaced at 2-0-0 oc. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 22, 23, 24, 26, 21, 20, 19, 18 except (jt=lb) 29=106, 27=200, 28=207, 17=115. 13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss E02 Truss Type Piggyback Base Qty 2 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388952 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:05:55 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-hflI4HNYOcpPvW8nyNgCeepM4j3P1?nGdgYscFy6gqg Scale = 1:59.4 1 2 3 4 5 6 7 12 11 10 9 8 13 14 15 16 17 18 19 20 4x6 4x6 1.5x4 4x6 3x8 MT18HS 3x4 6x8 1.5x4 6x8 3x8 MT18HS 6-0-6 6-0-6 15-2-10 9-2-4 21-3-0 6-0-6 -1-2-8 1-2-8 6-0-6 6-0-6 10-7-8 4-7-2 15-2-10 4-7-2 21-3-0 6-0-6 22-5-8 1-2-8 3-5-910-6-03-5-910-6-014.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-5], [3:0-3-2,0-2-0], [5:0-3-2,0-2-0], [6:Edge,0-1-5] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.31 0.52 0.11 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.26 -0.37 0.01 (loc) 9-11 9-11 8 l/defl >973 >673 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 130 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-11, 4-9 REACTIONS. (size)12=0-3-8, 8=0-3-8 Max Horz 12=246(LC 13) Max Uplift 12=-15(LC 14), 8=-15(LC 14) Max Grav 12=920(LC 1), 8=920(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-716/129, 3-4=-419/158, 4-5=-419/158, 5-6=-716/129, 2-12=-874/116, 6-8=-874/116 BOT CHORD 9-11=-21/510 WEBS 2-11=0/463, 6-9=0/464 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 6-0-6, Exterior(2) 6-0-6 to 10-3-5, Interior(1) 10-3-5 to 15-2-10, Exterior(2) 15-2-10 to 19-5-9, Interior(1) 19-5-9 to 22-5-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) All plates are MT20 plates unless otherwise indicated. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 8. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss E03 Truss Type Piggyback Base Girder Qty 1 Ply 2 WILSON RESIDENCE - 20LV Job Reference (optional) I49388953 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:05:57 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-d2s2VzPpwE378pIA3oigj3uj2Xq7VqTZ4_1zg7y6gqe Scale: 3/16"=1' 1 2 3 4 5 6 7 15 14 13 12 11 10 9 8 16 17 18 19 20 21 22 23 24 25 26 27 4x6 6x6 6x6 4x6 3x4 4x6 3x6 4x6 6x6 8x8 1.5x4 6x6 3x6 4x6 3x4 3-1-15 3-1-15 6-0-6 2-10-7 10-7-8 4-7-2 15-2-10 4-7-2 18-1-1 2-10-7 21-3-0 3-1-15 3-1-15 3-1-15 6-0-6 2-10-7 10-7-8 4-7-2 15-2-10 4-7-2 18-1-1 2-10-7 21-3-0 3-1-15 3-5-910-6-03-5-910-6-014.00 12 Plate Offsets (X,Y)-- [1:0-2-8,0-1-8], [3:0-3-0,0-1-8], [5:0-3-0,0-1-8], [7:0-2-8,0-1-8], [10:0-3-0,0-4-8], [12:0-3-0,0-4-8] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.21 0.25 0.36 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.04 -0.07 0.01 (loc) 11-12 11-12 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 372 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)15=0-3-8, 8=0-3-8 Max Horz 15=-214(LC 8) Max Grav 15=4857(LC 1), 8=5136(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-3175/0, 2-3=-3504/0, 3-4=-2784/0, 4-5=-2784/0, 5-6=-3498/0, 6-7=-3218/0, 1-15=-4545/0, 7-8=-4603/0 BOT CHORD 12-14=0/2019, 11-12=0/2247, 10-11=0/2243, 9-10=0/2046 WEBS 2-14=-902/0, 2-12=0/562, 3-12=0/1214, 3-11=0/1331, 4-11=-282/114, 5-11=0/1340, 5-10=0/1201, 6-10=0/486, 6-9=-795/0, 1-14=0/2885, 7-9=0/2920 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 6) Provide adequate drainage to prevent water ponding. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 832 lb down at 1-11-4, 832 lb down at 3-11-4, 832 lb down at 5-11-4, 832 lb down at 7-11-4, 832 lb down at 9-11-4, 832 lb down at 11-11-4, 832 lb down at 13-11-4, 832 lb down at 15-11-4, and 832 lb down at 17-11-4, and 832 lb down at 19-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. Continued on page 2 December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss E03 Truss Type Piggyback Base Girder Qty 1 Ply 2 WILSON RESIDENCE - 20LV Job Reference (optional) I49388953 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:05:57 2021 Page 2 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-d2s2VzPpwE378pIA3oigj3uj2Xq7VqTZ4_1zg7y6gqe LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-5=-60, 5-7=-60, 8-15=-20 Concentrated Loads (lb) Vert: 12=-832(F) 9=-832(F) 18=-832(F) 19=-832(F) 20=-832(F) 22=-832(F) 23=-832(F) 25=-832(F) 26=-832(F) 27=-832(F) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss F01 Truss Type GABLE Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388954 8.520 s Oct 22 2021 MiTek Industries, Inc. Wed Dec 22 13:18:19 2021 Page 1 84 Lumber, Franklin, IN ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-8lOm_cMIZk6sdTUZov?2jTKzsvn?mc??R2AhCVy6aVI Scale = 1:63.3 1 2 3 4 5 6 7 8 17 16 15 14 13 12 11 10 9 18 28 29 30 31 32 33 34 35 4x4 6x6 4x4 3x4 3x4 3x4 3x4 3x8 MT18HS 3x4 6x8 3x4 3x6 3x6 6-2-136-2-13 13-2-157-0-1 19-11-86-8-9 20-3-00-3-8 21-9-1 1-6-122-1-10 0-4-10 28-8-86-6-14 6-2-136-2-13 13-2-157-0-1 20-3-07-0-1 21-9-11-6-1 22-1-10 0-4-10 28-8-86-6-14 29-7-00-10-8 3-5-910-8-140-7-82-0-010-8-1414.00 12 Plate Offsets (X,Y)-- [1:0-0-8,0-1-8], [2:0-3-0,0-1-8], [8:0-3-0,0-0-14], [12:0-5-8,0-4-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.43 0.27 0.27 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.09 -0.12 0.01 (loc) 14-15 14-15 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 204 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E *Except* 5-13: 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 WEDGE Right: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 2-6. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. Except: 1 Row at midpt 5-12 WEBS 1 Row at midpt 2-15, 2-14, 3-14, 3-12, 4-18, 6-11 REACTIONS.All bearings 8-9-0 except (jt=length) 17=0-3-8. (lb) - Max Horz 17=-214(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 13, 11 Max Grav All reactions 250 lb or less at joint(s) 10, 9, 8 except 17=774(LC 27), 13=921(LC 27), 13=915(LC 1), 11=303(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-28=-657/54, 28-29=-543/65, 2-29=-543/93, 2-30=-359/120, 30-31=-358/120, 3-31=-357/120, 1-17=-724/52 BOT CHORD 15-35=-2/435, 14-35=-2/435, 12-13=-860/94, 12-18=-394/117, 5-18=-320/87 WEBS 12-14=0/423, 3-12=-524/47, 1-15=0/394 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=29ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 6-2-13, Exterior(2) 6-2-13 to 10-5-12, Interior(1) 10-5-12 to 21-9-1, Exterior(2) 21-9-1 to 25-11-15, Interior(1) 25-11-15 to 28-8-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) Provide adequate drainage to prevent water ponding. 6) All plates are MT20 plates unless otherwise indicated. 7) All plates are 1.5x4 MT20 unless otherwise indicated. 8) Gable studs spaced at 2-0-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 11. 12) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.Continued on page 2 December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss F01 Truss Type GABLE Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388954 8.520 s Oct 22 2021 MiTek Industries, Inc. Wed Dec 22 13:18:20 2021 Page 2 84 Lumber, Franklin, IN ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-dxy8ByMwK2EjEd3lLcWHGgt8cI7EV3F8givFkxy6aVH NOTES- 13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss F02 Truss Type Piggyback Base Qty 3 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388955 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:00 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-1dYB7?RhD9Rh?H1lkwFNLiWAhkqSiC8?nyFdHSy6gqb Scale = 1:62.1 1 2 3 4 5 6 7 15 14 13 12 11 10 9 8 16 17 18 19 20 21 22 23 4x4 6x6 6x6 3x4 3x4 3x4 1.5x4 6x8 3x4 3x4 3x8 MT18HS 3x4 4x4 6x8 6-2-13 6-2-13 13-2-15 7-0-1 20-1-4 6-10-5 20-3-0 0-1-12 22-1-10 1-10-10 28-8-8 6-6-14 6-2-136-2-13 13-2-157-0-1 20-3-07-0-1 22-1-101-10-10 28-8-86-6-14 29-7-00-10-8 3-5-910-8-141-0-142-0-010-8-1414.00 12 Plate Offsets (X,Y)-- [1:0-0-8,0-1-8], [2:0-3-0,0-1-8], [5:0-2-12,0-1-8], [6:Edge,0-1-5], [10:0-2-4,0-3-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.44 0.28 0.30 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.09 -0.12 0.01 (loc) 12-13 12-13 8 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 182 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E *Except* 4-11: 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 2-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 5-9-3 oc bracing: 10-11. 1 Row at midpt 4-10 WEBS 1 Row at midpt 2-13, 3-12, 3-10, 5-10 REACTIONS. (size)15=0-3-8, 11=0-3-8, 8=0-7-8 Max Horz 15=-227(LC 12) Max Uplift 8=-18(LC 14) Max Grav 15=812(LC 1), 11=1088(LC 1), 8=435(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-686/108, 2-3=-410/141, 5-6=-321/69, 1-15=-756/70, 6-8=-373/79 BOT CHORD 12-13=0/462, 10-11=-1027/81, 4-10=-312/79, 8-9=-149/369 WEBS 10-12=0/459, 3-10=-573/45, 5-10=-257/7, 5-9=0/270, 1-13=0/421, 6-9=-324/278 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=29ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 6-2-13, Exterior(2) 6-2-13 to 10-5-12, Interior(1) 10-5-12 to 22-1-10, Exterior(2) 22-1-10 to 26-4-9, Interior(1) 26-4-9 to 29-7-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) All plates are MT20 plates unless otherwise indicated. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss G01 Truss Type GABLE Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388956 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:01 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-Wp6ZKLSJ_SZYdRbxIdnctv3Qh8ELRhN9?c?Apuy6gqa Scale = 1:62.1 1 2 3 4 5 6 7 8 9 10 11 12 13 25 24 23 22 21 20 19 18 17 16 15 14 26 27 3x6 3x4 3x4 3x4 3x4 20-3-0 20-3-0 6-7-7 6-7-7 13-7-9 7-0-2 20-3-0 6-7-7 3-0-310-8-143-0-310-8-1414.00 12 Plate Offsets (X,Y)-- [5:0-1-5,Edge], [9:0-1-5,Edge], [22:0-1-12,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.11 0.04 0.17 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 14 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 149 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 5-9. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-19, 6-20, 4-21, 8-18, 10-17 REACTIONS.All bearings 20-3-0. (lb) - Max Horz 25=-219(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 14, 19, 21, 23, 18, 16, 15 except 25=-362(LC 12), 24=-203(LC 11) Max Grav All reactions 250 lb or less at joint(s) 14, 19, 20, 21, 23, 18, 17, 16, 15 except 25=458(LC 13), 24=396(LC 12) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-25=-438/373, 1-2=-255/220, 3-4=-283/324, 10-11=-282/323 WEBS 1-24=-302/297 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3) 0-1-12 to 3-1-12, Exterior(2) 3-1-12 to 6-7-7, Corner(3) 6-7-7 to 9-7-7, Exterior(2) 9-7-7 to 13-7-9, Corner(3) 13-7-9 to 16-7-9, Exterior(2) 16-7-9 to 20-1-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) Provide adequate drainage to prevent water ponding. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 9) Gable studs spaced at 2-0-0 oc. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 19, 21, 23, 18, 16, 15 except (jt=lb) 25=362, 24=203. 13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss G02 Truss Type Piggyback Base Qty 6 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388957 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:03 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-SCEKl0TaV4pGsklJQ2p4zK8dkxrFvc8STwUHuny6gqY Scale = 1:60.9 1 2 3 4 5 6 11 10 9 8 7 12 13 14 15 16 17 18 6x6 4x6 3x4 3x6 3x4 6x8 3x4 6x8 3x8 MT18HS 6-2-13 6-2-13 14-0-3 7-9-5 20-3-0 6-2-13 -1-2-8 1-2-8 6-2-13 6-2-13 14-0-3 7-9-5 20-3-0 6-2-13 21-5-8 1-2-8 3-5-910-8-143-5-910-8-1414.00 12 Plate Offsets (X,Y)-- [2:Edge,0-1-5], [3:0-2-12,0-1-8], [4:0-2-12,0-1-8], [5:Edge,0-1-5] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.65 0.33 0.09 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.12 -0.17 0.01 (loc) 8-10 8-10 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 118 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-10, 3-8, 4-8 REACTIONS. (size)11=0-3-8, 7=0-3-8 Max Horz 11=251(LC 13) Max Uplift 11=-16(LC 14), 7=-16(LC 14) Max Grav 11=880(LC 1), 7=880(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-678/134, 3-4=-379/163, 4-5=-668/133, 2-11=-826/122, 5-7=-826/122 BOT CHORD 10-11=-234/255, 8-10=-28/462 WEBS 2-10=0/438, 5-8=0/422 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-2-8 to 1-9-8, Interior(1) 1-9-8 to 6-2-13, Exterior(2) 6-2-13 to 10-5-12, Interior(1) 10-5-12 to 14-0-3, Exterior(2) 14-0-3 to 18-3-1, Interior(1) 18-3-1 to 21-5-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) All plates are MT20 plates unless otherwise indicated. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 7. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss H01 Truss Type Piggyback Base Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388958 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:04 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-wOnizMUCGNx7UuKWzmKJVYhqjL9Ge?YbhaDrQDy6gqX Scale = 1:64.9 1 2 3 4 7 6 5 8 9 10 11 12 4x4 4x6 3x4 4x6 3x4 3x8 MT18HS 3x4 7-3-11 7-3-11 15-6-9 8-2-15 7-3-11 7-3-11 11-3-6 3-11-11 15-6-9 4-3-3 5-8-411-2-09.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-8], [2:0-4-0,0-2-0], [4:Edge,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.57 0.48 0.34 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.21 -0.31 0.01 (loc) 5-6 5-6 5 l/defl >872 >598 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 104 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 2-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-5, 2-6, 3-5 REACTIONS. (size)5=Mechanical, 7=0-3-8 Max Horz 7=287(LC 11) Max Uplift 5=-123(LC 11) Max Grav 5=708(LC 19), 7=682(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-457/97, 2-3=-278/126, 1-7=-582/110 BOT CHORD 6-7=-402/423, 5-6=-169/276 WEBS 3-6=-142/347, 3-5=-523/238, 1-6=-37/360 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 7-3-11, Exterior(2) 7-3-11 to 11-3-6, Interior(1) 11-3-6 to 15-4-13 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 5=123. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss H01A Truss Type GABLE Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388959 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:05 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-OaL4AiVq1h3_62viXTrY2lD?TlVVNSolwEzOygy6gqW Scale = 1:64.9 1 2 3 4 7 6 5 27 28 29 30 31 4x4 4x6 3x4 4x6 3x4 3x8 MT18HS 3x4 3x4 3x4 3x4 3x4 3x4 3x4 7-3-11 7-3-11 15-6-9 8-2-15 7-3-11 7-3-11 11-3-6 3-11-11 15-6-9 4-3-3 5-8-411-2-09.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-8], [2:0-4-0,0-2-0], [4:Edge,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.57 0.48 0.34 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.21 -0.31 0.01 (loc) 5-6 5-6 5 l/defl >872 >598 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 174 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 2-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-5, 2-6, 3-5 REACTIONS. (size)5=Mechanical, 7=0-3-8 Max Horz 7=287(LC 11) Max Uplift 5=-123(LC 11) Max Grav 5=708(LC 19), 7=682(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-457/97, 2-3=-278/126, 1-7=-582/110 BOT CHORD 6-7=-402/423, 5-6=-169/276 WEBS 3-6=-142/347, 3-5=-523/238, 1-6=-37/360 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 7-3-11, Exterior(2) 7-3-11 to 11-3-6, Interior(1) 11-3-6 to 15-4-13 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable studs spaced at 2-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 10) Refer to girder(s) for truss to truss connections. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 5=123. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss K01 Truss Type Monopitch Qty 2 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388960 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:06 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-snvSN2WSo?BrjCUu5BMnazm6n9tQ6t4u9uixV6y6gqV Scale = 1:60.5 1 2 4 3 5 3x6 1.5x4 6x6 1.5x4 6-3-1 6-3-1 6-3-1 6-3-1 5-8-410-4-99.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.79 0.30 0.46 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.07 -0.14 -0.00 (loc) 3-4 3-4 3 l/defl >999 >505 n/a L/d 240 180 n/a PLATES MT20 Weight: 42 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-3 REACTIONS. (size)3=Mechanical, 4=0-3-8 Max Horz 4=261(LC 11) Max Uplift 3=-197(LC 11), 4=-52(LC 10) Max Grav 3=336(LC 19), 4=358(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-261/184, 1-4=-363/263 BOT CHORD 3-4=-412/409 WEBS 1-3=-408/428 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 6-1-5 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb) 3=197. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss K02 Truss Type Monopitch Qty 10 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388961 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:06 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-snvSN2WSo?BrjCUu5BMnazm6t9sq6tDu9uixV6y6gqV Scale = 1:60.5 1 2 4 3 5 3x6 1.5x4 6x6 3x4 0-4-0 0-4-0 6-7-1 6-3-1 6-7-1 6-7-1 5-5-410-4-99.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.78 0.34 0.45 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.09 -0.18 -0.00 (loc) 3-4 3-4 3 l/defl >858 >429 n/a L/d 240 180 n/a PLATES MT20 Weight: 43 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-3 REACTIONS. (size)3=Mechanical, 4=0-3-8 Max Horz 4=262(LC 13) Max Uplift 3=-185(LC 11), 4=-40(LC 10) Max Grav 3=341(LC 19), 4=360(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-270/189, 1-4=-336/232 BOT CHORD 3-4=-413/409 WEBS 1-3=-392/412 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 6-5-5 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb) 3=185. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss K03 Truss Type Monopitch Supported Gable Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388962 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:07 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-KzTqbOW4ZIKiLM35fuu07AJJsZHYrLh1OXSV1Yy6gqU Scale = 1:63.1 1 2 3 4 5 9 8 7 6 6x6 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 6x6 1.5x4 3x6 6-7-1 6-7-1 6-7-1 6-7-1 5-0-1410-0-39.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.70 0.06 0.44 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 61 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 *Except* 5-6: 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-6, 4-7 REACTIONS.All bearings 6-7-1. (lb) - Max Horz 9=252(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 6, 7 except 9=-249(LC 12), 8=-356(LC 11) Max Grav All reactions 250 lb or less at joint(s) 6, 7 except 9=459(LC 11), 8=371(LC 12) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-249/276, 3-4=-216/257 BOT CHORD 8-9=-395/430 WEBS 2-9=-813/758, 2-8=-821/844 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3) 0-1-12 to 3-1-12, Exterior(2) 3-1-12 to 6-5-5 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 7 except (jt=lb) 9=249, 8=356. 9) Non Standard bearing condition. Review required. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss L01 Truss Type Piggyback Base Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388963 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:09 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-HMbb04YK5vaQafDTmJwUCbOjMMsQJGFKrrxb5Ry6gqS Scale = 1:65.0 1 2 3 4 5 6 7 13 12 11 10 9 8 14 15 16 17 18 19 20 1.5x4 3x6 8x8 4x4 3x4 6x6 4x4 3x6 3x8 MT18HS 3x4 3x8 MT18HS 4x4 4x6 3-6-5 3-6-5 11-2-4 7-7-15 20-2-1 8-11-13 29-8-0 9-5-15 3-6-5 3-6-5 11-2-4 7-7-15 15-8-3 4-5-15 20-2-1 4-5-15 24-9-5 4-7-3 29-8-0 4-10-11 2-3-910-8-41-1-112-5-28-3-29.00 12 9.00 12 Plate Offsets (X,Y)-- [3:0-6-0,0-2-0], [5:0-2-4,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.45 0.48 0.37 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.22 -0.35 0.01 (loc) 9-11 8-9 8 l/defl >470 >329 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 145 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 12-13. WEBS 1 Row at midpt 4-11, 4-9 REACTIONS.All bearings 29-8-0. (lb) - Max Horz 13=-176(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 12 except 13=-100(LC 12) Max Grav All reactions 250 lb or less at joint(s) 13 except 12=577(LC 19), 11=656(LC 19), 9=784(LC 20), 8=350(LC 1), 8=350(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-12=-417/120, 3-11=-330/76, 5-9=-252/33, 6-9=-256/121 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 11-2-4, Exterior(2) 11-2-4 to 15-8-3, Interior(1) 15-8-3 to 20-2-1, Exterior(2) 20-2-1 to 24-5-0, Interior(1) 24-5-0 to 29-6-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12 except (jt=lb) 13=100. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss L02 Truss Type Piggyback Base Qty 12 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388964 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:10 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-lY9zDQZzsDiGCpogK0RjlpxtTmAD2bjU4Vg9ety6gqR Scale = 1:65.4 1 2 3 4 5 6 7 13 12 11 10 9 8 14 15 16 17 18 19 20 21 22 1.5x4 3x6 4x6 4x4 3x4 6x6 3x6 3x6 3x8 MT18HS 3x4 3x8 MT18HS 4x4 4x6 3-6-5 3-6-5 10-8-7 7-2-1 20-7-15 9-11-8 29-8-0 9-0-1 3-6-5 3-6-5 10-8-7 7-2-1 15-8-3 4-11-12 20-7-15 4-11-12 25-0-3 4-4-5 29-8-0 4-7-13 2-7-1510-8-41-6-12-5-28-3-29.00 12 9.00 12 Plate Offsets (X,Y)-- [3:0-4-0,0-2-0], [5:0-2-4,0-2-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.49 0.63 0.87 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.35 -0.50 0.10 (loc) 9-11 9-11 8 l/defl >999 >704 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 146 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-11-5 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-11, 4-9 REACTIONS. (size)13=0-3-8, 8=0-3-8 Max Horz 13=-179(LC 12) Max Grav 13=1175(LC 1), 8=1175(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-13=-1175/95, 1-2=-1904/173, 2-3=-1421/129, 3-4=-1069/152, 4-5=-949/129, 5-6=-1264/132 BOT CHORD 11-12=-165/1599, 9-11=-12/1120, 8-9=-47/962 WEBS 1-12=-86/1489, 2-11=-529/176, 3-11=0/470, 4-9=-332/66, 5-9=-3/490, 6-8=-1241/71 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 10-8-7, Exterior(2) 10-8-7 to 14-11-5, Interior(1) 14-11-5 to 20-7-15, Exterior(2) 20-7-15 to 25-1-7, Interior(1) 25-1-7 to 29-6-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Bearing at joint(s) 13 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss L03 Truss Type Piggyback Base Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388965 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:11 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-DkiLRlabdXq7qzMsukyyH0TwkAXan7NdI9QiAJy6gqQ Scale = 1:46.3 1 2 3 4 5 6 11 10 9 8 7 12 13 14 15 16 17 4x6 4x4 4x4 3x4 3x4 3x6 6x8 3x4 3x8 MT18HS 4x4 4x6 1-4-15 1-4-15 11-4-7 9-11-8 20-4-8 9-0-1 1-4-15 1-4-15 6-4-11 4-11-12 11-4-7 4-11-12 15-8-11 4-4-5 20-4-8 4-7-13 7-2-78-3-21-6-18-3-29.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.97 0.56 0.52 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.28 -0.41 0.01 (loc) 8-10 8-10 7 l/defl >876 >588 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 119 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 2-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-10 REACTIONS. (size)11=0-3-8, 7=0-3-8 Max Horz 11=-204(LC 12) Max Uplift 11=-38(LC 10) Max Grav 11=827(LC 20), 7=803(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-291/137, 3-4=-551/107, 4-5=-748/105, 1-11=-1004/26 BOT CHORD 8-10=0/500, 7-8=-30/607 WEBS 3-10=-565/122, 1-10=-65/898, 5-7=-751/45 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 5-7-13, Interior(1) 5-7-13 to 11-4-7, Exterior(2) 11-4-7 to 15-9-15, Interior(1) 15-9-15 to 20-2-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss L03A Truss Type GABLE Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388966 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:12 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-hxGje5aDOqy_R7x2RRTBqE05TatpWadmXp9Gimy6gqP Scale = 1:46.3 1 2 3 4 5 6 11 10 9 8 7 29 30 31 32 33 34 4x6 4x4 4x4 3x4 3x4 3x6 6x8 3x4 3x8 MT18HS 4x4 4x6 1-4-15 1-4-15 11-4-7 9-11-8 20-4-8 9-0-1 1-4-15 1-4-15 6-4-11 4-11-12 11-4-7 4-11-12 15-8-11 4-4-5 20-4-8 4-7-13 7-2-78-3-21-6-18-3-29.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.97 0.56 0.52 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.28 -0.41 0.01 (loc) 8-10 8-10 7 l/defl >876 >588 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 172 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 2-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-10 REACTIONS. (size)11=0-3-8, 7=0-3-8 Max Horz 11=-204(LC 12) Max Uplift 11=-38(LC 10) Max Grav 11=827(LC 20), 7=803(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-291/137, 3-4=-551/107, 4-5=-748/105, 1-11=-1004/26 BOT CHORD 8-10=0/500, 7-8=-30/607 WEBS 3-10=-565/122, 1-10=-65/898, 5-7=-751/45 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 5-7-13, Interior(1) 5-7-13 to 11-4-7, Exterior(2) 11-4-7 to 15-9-15, Interior(1) 15-9-15 to 20-2-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) Provide adequate drainage to prevent water ponding. 6) All plates are MT20 plates unless otherwise indicated. 7) All plates are 1.5x4 MT20 unless otherwise indicated. 8) Gable studs spaced at 2-0-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss L04 Truss Type Common Supported Gable Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388967 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:13 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-97q5sRbr984r3HWE?9_RMRYTHzJKF7uwmTvpECy6gqO Scale = 1:60.3 1 2 3 4 5 6 7 8 9 10 11 12 25 24 23 22 21 20 19 18 17 16 15 14 13 4x4 3x4 3x4 3x4 20-4-8 20-4-8 9-6-15 9-6-15 20-4-8 10-9-9 2-5-19-7-41-6-19.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-R 0.13 0.10 0.14 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 13 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 117 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-19 REACTIONS.All bearings 20-4-8. (lb) - Max Horz 25=-171(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 25, 20, 21, 23, 24, 18, 17, 16, 15 except 13=-314(LC 13), 14=-212(LC 12) Max Grav All reactions 250 lb or less at joint(s) 25, 19, 20, 21, 23, 24, 18, 17, 16, 15 except 13=333(LC 12), 14=334(LC 13) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 5-6=-218/252, 6-7=-218/252 WEBS 6-19=-251/155 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3) 0-1-12 to 3-1-12, Exterior(2) 3-1-12 to 9-6-15, Corner(3) 9-6-15 to 12-6-15, Exterior(2) 12-6-15 to 20-2-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 2-0-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 25, 20, 21, 23, 24, 18, 17, 16, 15 except (jt=lb) 13=314, 14=212. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss M01 Truss Type Piggyback Base Supported Gable Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388968 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:15 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-5WysG7d5glKZIagd7a1vSseicnzDj1HDDnOwJ5y6gqM Scale = 1:70.3 1 2 3 4 5 6 7 8 9 10 11 12 25 24 23 22 21 20 19 18 17 16 15 14 13 26 4x4 4x4 4x4 6x6 3x4 3x6 3x6 21-3-8 21-3-8 11-4-11 11-4-11 21-3-8 9-10-13 2-6-811-1-09.00 12 Plate Offsets (X,Y)-- [7:0-4-0,0-2-0], [12:Edge,0-3-8], [13:Edge,0-3-8], [21:0-2-0,0-1-4] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.52 0.20 0.14 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 13 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 164 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 7-12. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 12-13, 11-14, 10-15, 9-16, 8-17, 7-18, 6-19 REACTIONS.All bearings 21-3-8. (lb) - Max Horz 25=291(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 25, 13, 14, 15, 16, 17, 18, 19, 20, 22 except 23=-301(LC 11), 24=-150(LC 12) Max Grav All reactions 250 lb or less at joint(s) 25, 13, 14, 15, 16, 17, 18, 19, 20, 22 except 23=299(LC 19), 24=409(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-342/338, 3-4=-302/306, 4-5=-244/257 BOT CHORD 24-25=-413/418, 23-24=-413/418 WEBS 2-24=-662/578, 2-23=-590/626 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3) 0-1-12 to 3-3-8, Exterior(2) 3-3-8 to 11-4-11, Corner(3) 11-4-11 to 14-4-11, Exterior(2) 14-4-11 to 21-1-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Provide adequate drainage to prevent water ponding. 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 2-0-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 25, 13, 14, 15, 16, 17, 18, 19, 20, 22 except (jt=lb) 23=301, 24=150. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss M02 Truss Type Piggyback Base Qty 10 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388969 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:16 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-ZiWEUTdjR3SQwkFpgHY8_4AqDBJESQtMSR7TrXy6gqL Scale: 3/16"=1' 1 2 3 4 5 11 10 9 8 7 6 12 13 14 15 16 17 18 4x6 3x4 1.5x4 3x4 3x6 3x4 3x4 6x8 1.5x4 6x8 4x6 5-7-3 5-7-3 10-10-13 5-3-11 16-2-15 5-4-1 21-7-0 5-4-1 5-7-3 5-7-3 10-10-13 5-3-11 16-2-15 5-4-1 21-7-0 5-4-1 2-10-1411-1-09.00 12 Plate Offsets (X,Y)-- [3:0-6-0,0-2-0], [6:Edge,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.73 0.21 0.38 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.06 0.01 (loc) 7-8 6-7 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 141 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-6, 2-8, 3-7, 4-7 REACTIONS. (size)6=0-3-8, 11=Mechanical Max Horz 11=290(LC 11) Max Uplift 6=-96(LC 11) Max Grav 6=963(LC 19), 11=858(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-783/66, 2-3=-672/144, 3-4=-389/147, 4-5=-389/148, 5-6=-853/158, 1-11=-811/62 BOT CHORD 10-11=-404/436, 8-10=-283/680, 7-8=-203/519 WEBS 2-8=-281/128, 3-8=-45/360, 3-7=-316/131, 4-7=-372/125, 5-7=-150/833, 1-10=0/618 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 10-10-13, Exterior(2) 10-10-13 to 15-1-12, Interior(1) 15-1-12 to 21-5-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss PB01 Truss Type GABLE Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388970 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:18 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-W5e_v9f_zgi892PCoiac3VGKG_2KwNofwlcawPy6gqJ Scale = 1:47.4 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 1 17 18 19 20 4x4 3x4 14-9-8 14-9-8 10-11-8 10-11-8 14-9-8 3-10-0 -0-0-48-2-68-2-105-3-145-2-80-1-109.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.11 0.04 0.16 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 10 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 75 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 14-9-8. (lb) - Max Horz 1=182(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 1, 10, 2, 12, 13, 14, 15, 16, 11 Max Grav All reactions 250 lb or less at joint(s) 1, 10, 2, 12, 13, 14, 15, 16, 11 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-254/289 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-7 to 3-3-7, Interior(1) 3-3-7 to 10-11-8, Exterior(2) 10-11-8 to 13-11-8, Interior(1) 13-11-8 to 14-7-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 2-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Bearing at joint(s) 1, 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 10, 2, 12, 13, 14, 15, 16, 11. 12) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss PB02 Truss Type GABLE Qty 10 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388971 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:19 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-_HBN6Ugck_q?nC_OMP5rcioUXOMGfpYo8PM7Ssy6gqI Scale = 1:51.8 2 3 4 5 6 10 9 8 7 1 11 12 13 4x4 1.5x4 1.5x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 15-3-5 15-3-5 11-5-5 11-5-5 15-3-5 3-10-0 -0-0-48-6-128-7-05-6-140-1-109.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.14 0.13 0.25 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 61 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 15-3-5. (lb) - Max Horz 1=192(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 7, 2, 9, 10 except 1=-104(LC 20) Max Grav All reactions 250 lb or less at joint(s) 1, 7, 2 except 8=435(LC 20), 9=402(LC 20), 10=283(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-271/307 WEBS 4-9=-266/122 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-7 to 3-5-5, Interior(1) 3-5-5 to 11-5-5, Exterior(2) 11-5-5 to 14-5-5, Interior(1) 14-5-5 to 15-1-9 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 4-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Bearing at joint(s) 1, 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 2, 9, 10 except (jt=lb) 1=104. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss PB03 Truss Type GABLE Qty 2 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388972 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:22 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-OstVkWiU1vCZefiz1YfYELQ?xbOzsBJFqNan3By6gqF Scale = 1:54.3 2 3 4 5 6 7 8 15 14 13 12 11 10 1 16 17 9 4x4 3x4 3x4 3x4 22-10-11 22-10-11 11-5-5 11-5-5 22-10-11 11-5-5 -0-0-48-6-128-7-00-1-20-1-109.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.13 0.13 0.19 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 8 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 81 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 22-10-11. (lb) - Max Horz 1=-134(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 9, 13, 15, 11, 10 except 1=-109(LC 24) Max Grav All reactions 250 lb or less at joint(s) 1, 9, 2, 8 except 12=369(LC 20), 13=403(LC 20), 15=282(LC 1), 11=402(LC 21), 10=282(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 4-13=-266/119, 6-11=-266/119 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-7 to 3-5-5, Interior(1) 3-5-5 to 11-5-5, Exterior(2) 11-5-5 to 14-5-5, Interior(1) 14-5-5 to 22-7-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 4-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 13, 15, 11, 10 except (jt=lb) 1=109. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss PB04 Truss Type GABLE Qty 14 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388973 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:24 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-KE?G9CklZWTHuzsM8yh0JmWJWP3_K7CXIh3u73y6gqD Scale = 1:24.7 2 3 4 6 1 7 8 9 10 5 4x4 3x4 3x4 1.5x4 9-11-8 9-11-8 4-11-12 4-11-12 9-11-8 4-11-12 -0-0-43-8-93-8-130-1-20-1-109.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.26 0.15 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 27 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 9-11-8. (lb) - Max Horz 1=56(LC 13) Max Uplift All uplift 100 lb or less at joint(s) except 1=-317(LC 20), 5=-292(LC 1), 2=-143(LC 14), 4=-143(LC 14) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 2=535(LC 20), 4=533(LC 1), 6=271(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-7 to 3-3-7, Interior(1) 3-3-7 to 4-11-12, Exterior(2) 4-11-12 to 7-11-12, Interior(1) 7-11-12 to 9-8-1 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 4-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 317 lb uplift at joint 1, 292 lb uplift at joint 5, 143 lb uplift at joint 2 and 143 lb uplift at joint 4. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss PB04A Truss Type GABLE Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388974 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:27 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-lpgOoEmdsRrslQbxq5EjxO8u1c6iXUD__fIYkOy6gqA Scale = 1:22.4 2 3 4 5 6 10 9 8 1 11 12 13 14 7 4x4 3x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 8-11-13 8-11-13 4-5-15 4-5-15 8-11-13 4-5-15 -0-0-43-4-33-4-70-1-20-1-109.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.05 0.03 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 27 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 8-11-13. (lb) - Max Horz 1=-50(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 1, 7, 2, 6, 10, 8 Max Grav All reactions 250 lb or less at joint(s) 1, 7, 2, 6, 9, 10, 8 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-7 to 3-3-7, Interior(1) 3-3-7 to 4-5-15, Exterior(2) 4-5-15 to 7-5-15, Interior(1) 7-5-15 to 8-8-7 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7, 2, 6, 10, 8. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss PB06 Truss Type GABLE Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388975 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:29 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-hCo9CvntN35a_kkJxWHB0pDEdQoE?NLHRznfpHy6gq8 Scale = 1:56.7 2 3 4 6 7 8 9 10 5 18 17 16 15 14 13 12 1 19 20 21 11 226x6 3x4 3x4 4x4 15-10-13 15-10-13 7-11-6 7-11-6 15-10-13 7-11-6 -0-0-48-9-118-9-150-1-60-1-1014.00 12 Plate Offsets (X,Y)-- [4:0-0-0,0-3-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.04 0.02 0.11 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 10 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 77 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-15 REACTIONS.All bearings 15-10-13. (lb) - Max Horz 1=165(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 10, 16, 18, 14, 13, 12, 11, 17 except 1=-148(LC 12) Max Grav All reactions 250 lb or less at joint(s) 1, 2, 10, 15, 16, 18, 14, 13, 12, 11, 17 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-2-10 to 3-2-10, Interior(1) 3-2-10 to 7-11-6, Exterior(2) 7-11-6 to 10-11-6, Interior(1) 10-11-6 to 15-3-11 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 2-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Bearing at joint(s) 10, 11 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 16, 18, 14, 13, 12, 11, 17 except (jt=lb) 1=148. 12) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss PB07 Truss Type GABLE Qty 3 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388976 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:31 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-dbwvdbp8vgLID2ui3xJf5EIYoET2TH3ZvGGmt9y6gq6 Scale = 1:58.3 2 3 4 5 6 10 9 8 1 11 12 13 14 7 4x4 3x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 15-10-13 15-10-13 7-11-6 7-11-6 15-10-13 7-11-6 -0-0-49-3-19-3-50-1-20-1-1014.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.13 0.13 0.09 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 63 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-9 REACTIONS.All bearings 15-10-13. (lb) - Max Horz 1=-174(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 2, 6 except 1=-268(LC 12), 7=-161(LC 21), 10=-122(LC 14), 8=-122(LC 14) Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 2=368(LC 20), 6=348(LC 1), 9=336(LC 24), 10=434(LC 20), 8=433(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-203/314 WEBS 3-10=-320/227, 5-8=-320/227 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-2-10 to 3-2-10, Interior(1) 3-2-10 to 7-11-6, Exterior(2) 7-11-6 to 10-11-6, Interior(1) 10-11-6 to 15-8-3 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 4-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Bearing at joint(s) 1, 7, 2, 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6 except (jt=lb) 1=268, 7=161, 10=122, 8=122. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss PB09 Truss Type GABLE Qty 6 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388977 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:32 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-5nUHrxqmg_T9rBTucequeSriedolClGj8w?JPby6gq5 Scale = 1:30.9 2 3 4 6 17 8 9 10 5 4x4 3x4 3x4 1.5x4 7-9-5 7-9-5 3-10-11 3-10-11 7-9-5 3-10-11 -0-0-44-6-34-6-70-1-20-1-1014.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.18 0.10 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 25 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 7-9-5. (lb) - Max Horz 1=-83(LC 12) Max Uplift All uplift 100 lb or less at joint(s) except 1=-352(LC 20), 5=-300(LC 21), 2=-207(LC 14), 4=-207(LC 14) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 6 except 2=530(LC 20), 4=487(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-209/288 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-2-10 to 3-2-10, Interior(1) 3-2-10 to 3-10-11, Exterior(2) 3-10-11 to 6-10-11, Interior(1) 6-10-11 to 7-6-11 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 4-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Bearing at joint(s) 1, 5, 2, 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 352 lb uplift at joint 1, 300 lb uplift at joint 5, 207 lb uplift at joint 2 and 207 lb uplift at joint 4. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss PB09A Truss Type GABLE Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388978 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:34 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-2Ab2Gdr0Cbjt4VdHk3tMjtw4GRVJgen0bEUQUUy6gq3 Scale = 1:28.7 2 3 4 5 6 10 9 8 1 7 4x4 3x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 7-0-2 7-0-2 3-6-1 3-6-1 7-0-2 3-6-1 -0-0-44-0-134-1-10-1-20-1-1014.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.05 0.03 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 25 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 7-0-2. (lb) - Max Horz 1=-74(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 1, 6, 10, 8 Max Grav All reactions 250 lb or less at joint(s) 1, 7, 2, 6, 9, 10, 8 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Bearing at joint(s) 1, 7, 2, 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 6, 10, 8. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss PB11 Truss Type GABLE Qty 3 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388979 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:35 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-WM9QTzsezvrjifCTHmObG4TBdrpmP5h9quE_0wy6gq2 Scale = 1:36.0 2 3 4 6 1 7 8 9 10 5 4x4 3x4 3x4 1.5x4 9-2-4 9-2-4 4-7-2 4-7-2 9-2-4 4-7-2 -0-0-45-4-15-4-50-1-20-1-1014.00 12 Plate Offsets (X,Y)-- [2:0-2-14,Edge], [4:0-2-14,Edge] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.26 0.14 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 30 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 9-2-4. (lb) - Max Horz 1=-98(LC 12) Max Uplift All uplift 100 lb or less at joint(s) except 1=-512(LC 20), 5=-450(LC 21), 2=-301(LC 14), 4=-301(LC 14) Max Grav All reactions 250 lb or less at joint(s) 6 except 1=275(LC 14), 5=275(LC 14), 2=722(LC 20), 4=671(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-288/399, 4-5=-290/356 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-2-10 to 3-2-10, Interior(1) 3-2-10 to 4-7-2, Exterior(2) 4-7-2 to 7-7-2, Interior(1) 7-7-2 to 8-11-10 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 4-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Bearing at joint(s) 1, 5, 2, 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 512 lb uplift at joint 1, 450 lb uplift at joint 5, 301 lb uplift at joint 2 and 301 lb uplift at joint 4. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss PB11A Truss Type GABLE Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388980 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:36 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-_YjogJtGkCzaKpnfrUvqoI?QlFBp8YHJ2YzXZNy6gq1 Scale = 1:33.2 2 3 4 5 6 10 9 8 1 11 12 13 14 7 4x4 3x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 8-5-0 8-5-0 4-2-8 4-2-8 8-5-0 4-2-8 -0-0-44-10-114-10-150-1-20-1-1014.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.05 0.02 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 32 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 8-5-0. (lb) - Max Horz 1=90(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 1, 7, 2, 10, 8 Max Grav All reactions 250 lb or less at joint(s) 1, 7, 2, 6, 9, 10, 8 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-2-10 to 3-2-10, Interior(1) 3-2-10 to 4-2-8, Exterior(2) 4-2-8 to 7-2-8, Interior(1) 7-2-8 to 8-2-6 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Bearing at joint(s) 1, 7, 2, 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7, 2, 10, 8. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss PB12 Truss Type GABLE Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388981 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:38 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-wxrY5_uXGqDIZ6x2zvxItj5jc2r1cRwbWsSedFy6gq? Scale = 1:44.2 2 3 4 5 6 7 12 11 10 9 8 1 13 14 3x4 3x4 3x4 9-10-13 9-10-13-0-0-47-5-27-3-80-1-109.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.22 0.10 0.08 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 8 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 46 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 9-10-13. (lb) - Max Horz 1=191(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 1, 8, 12, 11, 10, 9 Max Grav All reactions 250 lb or less at joint(s) 1, 8, 2, 12, 11, 10, 9 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-381/378, 2-3=-317/303, 3-4=-270/258 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-7 to 3-3-7, Interior(1) 3-3-7 to 9-9-1 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) All plates are 1.5x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Bearing at joint(s) 1, 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 8, 12, 11, 10, 9. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss PB13 Truss Type Piggyback Qty 10 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388982 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:39 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-O7PxJKv917M9BGVEWcSXQwdtdSB0LtHllWCB9iy6gq_ Scale = 1:45.4 1 2 3 4 5 8 7 6 9 10 11 3x4 3x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 10-8-3 10-8-30-4-107-10-80-1-100-1-109.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.26 0.12 0.14 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 0.00 (loc) 1 1 6 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 45 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 9-11-13. (lb) - Max Horz 2=206(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 6, 8, 7 Max Grav All reactions 250 lb or less at joint(s) 6, 2 except 8=404(LC 20), 7=330(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-313/313 WEBS 3-8=-271/139 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-7 to 3-3-7, Interior(1) 3-3-7 to 10-6-7 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) This truss has been designed for greater of min roof live load of 12.0 psf or 1.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 8, 7. 8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss PB15 Truss Type GABLE Qty 6 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388983 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:40 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-sJzJWgwnoRU0oQ4R4Kzmz8A5fsYA4MSuzAxkh8y6gpz Scale = 1:25.9 2 3 4 6 1 5 4x4 3x4 3x4 1.5x4 6-5-2 6-5-2 3-2-9 3-2-9 6-5-2 3-2-9 -0-0-43-8-123-9-00-1-20-1-1014.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.12 0.06 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 21 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 6-5-2. (lb) - Max Horz 1=-67(LC 12) Max Uplift All uplift 100 lb or less at joint(s) except 1=-226(LC 20), 5=-184(LC 21), 2=-134(LC 14), 4=-134(LC 14) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 6 except 2=373(LC 20), 4=339(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 4-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Bearing at joint(s) 1, 5, 2, 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 226 lb uplift at joint 1, 184 lb uplift at joint 5, 134 lb uplift at joint 2 and 134 lb uplift at joint 4. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss PB15A Truss Type GABLE Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388984 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:41 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-LWWhk0xPZlctQafde1V?VLjGvGufppm2CqhIDay6gpy Scale = 1:22.9 2 3 4 6 1 5 4x4 3x4 3x4 1.5x4 5-7-14 5-7-14 2-9-15 2-9-15 5-7-14 2-9-15 -0-0-43-3-63-3-100-1-20-1-1014.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.09 0.05 0.01 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-7-14 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 5-7-14. (lb) - Max Horz 1=-59(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 2, 4 except 1=-167(LC 20), 5=-130(LC 21) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 6 except 2=296(LC 20), 4=266(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Bearing at joint(s) 1, 5, 2, 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4 except (jt=lb) 1=167, 5=130. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss PB16 Truss Type GABLE Qty 2 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388985 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:42 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-pi43xMy1K2kk2kEpCk0E2ZFPVfECYGaBRUQrl0y6gpx Scale = 1:33.2 2 3 4 5 6 10 9 8 7 1 11 12 3x4 8-2-15 8-2-15-0-0-46-2-36-1-156-0-90-1-109.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.22 0.03 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 35 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 8-2-15. (lb) - Max Horz 1=157(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 1, 7, 2, 8, 9, 10 Max Grav All reactions 250 lb or less at joint(s) 1, 7, 2, 8, 9, 10 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-332/326, 2-3=-266/250 NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-7 to 3-3-7, Interior(1) 3-3-7 to 8-1-3 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) All plates are 1.5x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Bearing at joint(s) 1, 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7, 2, 8, 9, 10. 11) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss V01 Truss Type Valley Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388986 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:43 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-HueR8iyf4Msbfup?lSXTamobe3Z6HfAKf8APHTy6gpw Scale = 1:73.5 1 2 3 4 5 6 7 13 12 11 10 9 8 14 15 16 17 18 193x4 4x4 3x4 3x4 0-0-3 0-0-3 20-7-3 20-6-15 10-3-9 10-3-9 20-7-3 10-3-9 0-0-412-0-30-0-414.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.13 0.11 0.27 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 92 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-10 REACTIONS.All bearings 20-6-12. (lb) - Max Horz 1=225(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 7, 13, 8 except 1=-112(LC 12), 11=-129(LC 14), 9=-129(LC 14) Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 10=317(LC 19), 11=516(LC 19), 13=330(LC 19), 9=515(LC 20), 8=330(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-11=-329/222, 2-13=-253/178, 5-9=-329/222, 6-8=-253/178 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 10-3-9, Exterior(2) 10-3-9 to 13-3-9, Interior(1) 13-3-9 to 20-3-6 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) All plates are 1.5x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 13, 8 except (jt=lb) 1=112, 11=129, 9=129. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss V02 Truss Type Valley Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388987 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:45 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-DHmCZN_wcz6JvBzOttZxfBtw4tERlasd7SfVMLy6gpu Scale = 1:66.7 1 2 3 4 5 9 8 7 6 10 11 12 13 3x4 4x4 3x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 18-0-1 18-0-1 18-0-5 0-0-3 9-0-2 9-0-2 18-0-5 9-0-2 0-0-410-6-30-0-414.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.20 0.12 0.20 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 74 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-7 REACTIONS.All bearings 17-11-14. (lb) - Max Horz 1=-196(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 1 except 9=-156(LC 14), 6=-156(LC 14) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=307(LC 19), 9=534(LC 19), 6=534(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-391/262, 4-6=-391/262 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 9-0-2, Exterior(2) 9-0-2 to 12-0-2, Interior(1) 12-0-2 to 17-8-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 9=156, 6=156. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss V03 Truss Type Valley Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388988 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:46 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-hTKanj?YNHEAWLYaRa4ACPQ6qHaaU3onM6O3uoy6gpt Scale = 1:55.3 1 2 3 4 5 8 7 6 9 10 11 12 3x4 4x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 15-5-4 15-5-4 15-5-7 0-0-3 7-8-12 7-8-12 15-5-7 7-8-12 0-0-49-0-30-0-414.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.14 0.13 0.09 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 62 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-7 REACTIONS.All bearings 15-5-0. (lb) - Max Horz 1=-167(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 1 except 8=-130(LC 14), 6=-130(LC 14) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=330(LC 19), 8=454(LC 19), 6=454(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-334/231, 4-6=-334/231 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 7-8-12, Exterior(2) 7-8-12 to 10-8-12, Interior(1) 10-8-12 to 15-1-10 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 8=130, 6=130. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss V04 Truss Type Valley Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388989 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:47 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-9guy_3?A8bM08V7n_IbPlczHrgwzDWiwam8cQEy6gps Scale = 1:46.4 1 2 3 4 5 8 7 6 9 10 11 123x4 4x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 12-10-6 12-10-6 12-10-9 0-0-3 6-5-5 6-5-5 12-10-9 6-5-5 0-0-47-6-30-0-414.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.12 0.12 0.11 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 49 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 12-10-3. (lb) - Max Horz 1=138(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-113(LC 14), 6=-113(LC 14) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=327(LC 19), 8=370(LC 19), 6=370(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-299/218, 4-6=-299/219 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 6-5-5, Exterior(2) 6-5-5 to 9-5-5, Interior(1) 9-5-5 to 12-6-13 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 8=113, 6=113. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss V05 Truss Type Valley Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388990 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:49 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-62?iPl1QgCckNpG96jetq12cCUc?hQtD24djV6y6gpq Scale = 1:38.1 1 2 3 4 5 8 7 6 9 10 11 12 3x4 4x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 0-0-3 0-0-3 10-3-12 10-3-8 5-1-14 5-1-14 10-3-12 5-1-14 0-0-46-0-30-0-414.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.13 0.08 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 37 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 10-3-5. (lb) - Max Horz 1=109(LC 13) Max Uplift All uplift 100 lb or less at joint(s) except 1=-141(LC 12), 5=-125(LC 13), 8=-127(LC 14), 6=-127(LC 14) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=376(LC 19), 6=376(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-354/279, 4-6=-354/279 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 5-1-14, Exterior(2) 5-1-14 to 8-1-14, Interior(1) 8-1-14 to 9-11-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 141 lb uplift at joint 1, 125 lb uplift at joint 5, 127 lb uplift at joint 8 and 127 lb uplift at joint 6. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss V06 Truss Type Valley Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388991 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:53 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-_pFDF74xkR6AsQawLYip_tCIb5zrdELpzibweuy6gpm Scale = 1:29.6 1 2 3 4 5 6 7 8 3x4 4x4 3x4 1.5x4 0-0-3 0-0-3 7-8-14 7-8-11 3-10-7 3-10-7 7-8-14 3-10-7 0-0-44-6-30-0-414.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.17 0.09 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 26 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=7-8-7, 3=7-8-7, 4=7-8-7 Max Horz 1=-80(LC 12) Max Uplift 1=-18(LC 14), 3=-18(LC 14) Max Grav 1=178(LC 1), 3=178(LC 1), 4=219(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 3-10-7, Exterior(2) 3-10-7 to 6-10-7, Interior(1) 6-10-7 to 7-5-1 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 18 lb uplift at joint 1 and 18 lb uplift at joint 3. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss V07 Truss Type Valley Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388992 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:54 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-S0pbSS5ZVkE1Ua97vGD2X5lUxVKsMh_yBLKUAKy6gpl Scale = 1:21.6 1 2 3 43x4 4x4 3x4 1.5x4 0-0-3 0-0-3 5-2-0 5-1-13 2-7-0 2-7-0 5-2-0 2-7-0 0-0-43-0-30-0-414.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.07 0.04 0.01 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=5-1-9, 3=5-1-9, 4=5-1-9 Max Horz 1=-51(LC 12) Max Uplift 1=-11(LC 14), 3=-11(LC 14) Max Grav 1=114(LC 1), 3=114(LC 1), 4=139(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 11 lb uplift at joint 1 and 11 lb uplift at joint 3. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss V08 Truss Type Valley Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388993 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:56 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-POwMt86p1MVljtJV0hGWcWqpLJ?9qYxFffpbFCy6gpj Scale = 1:70.7 1 2 3 4 5 6 7 13 12 11 10 9 8 14 15 16 17 183x4 4x4 3x4 3x4 19-9-5 19-9-5 19-9-9 0-0-3 9-10-12 9-10-12 19-9-9 9-10-12 0-0-411-6-90-0-414.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.14 0.11 0.24 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 87 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-10 REACTIONS.All bearings 19-9-2. (lb) - Max Horz 1=-216(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 7, 13, 8 except 1=-127(LC 12), 11=-129(LC 14), 9=-129(LC 14) Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 10=319(LC 19), 11=507(LC 19), 13=307(LC 19), 9=510(LC 20), 8=313(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-11=-331/225, 5-9=-331/225 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 9-10-12, Exterior(2) 9-10-12 to 12-10-12, Interior(1) 12-10-12 to 19-5-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) All plates are 1.5x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 13, 8 except (jt=lb) 1=127, 11=129, 9=129. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss V09 Truss Type Valley Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388994 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:57 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-tbUk5U7RnfdcL1tiaOnl9jN_WiKEZ0TOtJZ8nfy6gpi Scale: 3/16"=1' 1 2 3 4 5 9 8 7 6 10 11 12 13 3x4 4x4 3x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 0-0-3 0-0-3 17-2-11 17-2-7 8-7-5 8-7-5 17-2-11 8-7-5 0-0-410-0-90-0-414.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.17 0.12 0.16 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 70 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-7 REACTIONS.All bearings 17-2-4. (lb) - Max Horz 1=-187(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 1 except 9=-147(LC 14), 6=-147(LC 14) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=315(LC 19), 9=507(LC 19), 6=507(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-371/251, 4-6=-371/251 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 8-7-5, Exterior(2) 8-7-5 to 11-7-5, Interior(1) 11-7-5 to 16-10-14 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 9=147, 6=147. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss V10 Truss Type Valley Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388995 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:58 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-Ln26Iq84YzlTzBSu85I_hxwA?6gOITvY6zIhJ5y6gph Scale = 1:52.6 1 2 3 4 5 8 7 6 9 10 11 123x4 4x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 14-7-10 14-7-10 14-7-13 0-0-3 7-3-15 7-3-15 14-7-13 7-3-15 0-0-48-6-90-0-414.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.12 0.13 0.14 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 58 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 14-7-6. (lb) - Max Horz 1=-158(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-124(LC 14), 6=-124(LC 14) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=333(LC 19), 8=425(LC 19), 6=425(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-320/224, 4-6=-320/224 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-13 to 3-3-15, Interior(1) 3-3-15 to 7-3-15, Exterior(2) 7-3-15 to 10-3-15, Interior(1) 10-3-15 to 14-4-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 8=124, 6=124. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss V11 Truss Type Valley Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388996 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:06:59 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-pzcUVA9iJHtJaL14hppDE8SLpW0w1xvhLd2FsXy6gpg Scale = 1:43.7 1 2 3 4 5 8 7 6 9 10 11 123x4 4x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 12-0-12 12-0-12 12-0-15 0-0-3 6-0-8 6-0-8 12-0-15 6-0-8 0-0-47-0-90-0-414.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.12 0.11 0.10 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 45 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 12-0-9. (lb) - Max Horz 1=-129(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-111(LC 14), 6=-111(LC 14) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=317(LC 19), 8=356(LC 19), 6=356(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-299/222, 4-6=-299/221 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 6-0-8, Exterior(2) 6-0-8 to 9-0-8, Interior(1) 9-0-8 to 11-9-3 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 8=111, 6=111. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss V12 Truss Type Valley Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388997 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:07:00 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-HAAtjWAK4a?ACVcHFWKSmM?VVwLjmOWraHnoO_y6gpf Scale = 1:35.6 1 2 3 4 5 6 7 8 3x4 4x4 3x4 1.5x4 9-5-14 9-5-14 9-6-2 0-0-3 4-9-1 4-9-1 9-6-2 4-9-1 0-0-45-6-90-0-414.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.19 0.13 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 32 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=9-5-11, 3=9-5-11, 4=9-5-11 Max Horz 1=-100(LC 12) Max Uplift 1=-10(LC 14), 3=-10(LC 14) Max Grav 1=208(LC 1), 3=208(LC 1), 4=294(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 4-9-1, Exterior(2) 4-9-1 to 7-9-1, Interior(1) 7-9-1 to 9-2-5 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss V13 Truss Type Valley Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388998 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:07:01 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-lMkFwsAyru71qfBTpEshJZYg9Ki?VsV_oxXMwQy6gpe Scale = 1:28.0 1 2 3 43x4 4x4 3x4 1.5x4 0-0-3 0-0-3 6-11-4 6-11-1 3-5-10 3-5-10 6-11-4 3-5-10 0-0-44-0-90-0-414.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.13 0.07 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 23 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=6-10-13, 3=6-10-13, 4=6-10-13 Max Horz 1=71(LC 13) Max Uplift 1=-16(LC 14), 3=-16(LC 14) Max Grav 1=158(LC 1), 3=158(LC 1), 4=194(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss V14 Truss Type Valley Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49388999 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:07:02 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-DYId8BBacCFuRomfNxNwsn4tGj3vEJ?71bGvSsy6gpd Scale = 1:15.6 1 2 3 4 3x4 4x4 3x4 1.5x4 0-0-3 0-0-3 4-4-6 4-4-3 2-2-3 2-2-3 4-4-6 2-2-3 0-0-42-6-90-0-414.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.04 0.02 0.01 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-4-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=4-3-15, 3=4-3-15, 4=4-3-15 Max Horz 1=-42(LC 12) Max Uplift 1=-9(LC 14), 3=-9(LC 14) Max Grav 1=94(LC 1), 3=94(LC 1), 4=115(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss V15 Truss Type Valley Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49389000 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:07:03 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-hls?LXCCNVNl3yLrwfu9O_d?M7Oozi8HGF0S?Iy6gpc Scale = 1:73.5 1 2 3 4 5 6 12 11 10 9 8 7 13 14 15 163x4 4x4 3x4 17-2-12 17-2-12 10-2-12 10-2-12 17-2-12 7-0-0 0-0-411-11-43-9-414.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.15 0.11 0.27 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 84 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-9 REACTIONS.All bearings 17-2-9. (lb) - Max Horz 1=252(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 7, 12 except 1=-204(LC 12), 9=-121(LC 13), 10=-128(LC 14), 8=-125(LC 14) Max Grav All reactions 250 lb or less at joint(s) 7 except 1=258(LC 13), 9=503(LC 19), 10=515(LC 19), 12=327(LC 19), 8=478(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-328/320, 2-3=-308/264, 3-4=-317/338, 4-5=-314/326 WEBS 4-9=-417/265, 3-10=-335/230, 2-12=-259/188, 5-8=-311/216 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 10-2-12, Exterior(2) 10-2-12 to 13-2-12, Interior(1) 13-2-12 to 17-1-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) All plates are 1.5x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 12 except (jt=lb) 1=204, 9=121, 10=128, 8=125. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss V16 Truss Type Valley Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49389001 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:07:04 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-AxPNZtDq8pVch6w2UMPOxCA9KXjtiBfQUvl0Xly6gpb Scale = 1:64.9 1 2 3 4 5 9 8 7 6 10 11 12 3x4 4x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 15-11-5 15-11-5 8-11-5 8-11-5 15-11-5 7-0-0 0-0-410-5-42-3-414.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.20 0.12 0.19 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 71 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-8 REACTIONS.All bearings 15-11-2. (lb) - Max Horz 1=211(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 1, 6, 8 except 9=-153(LC 14), 7=-132(LC 14) Max Grav All reactions 250 lb or less at joint(s) 6 except 1=267(LC 20), 8=476(LC 19), 9=526(LC 19), 7=431(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-278/265, 2-3=-294/304, 3-4=-284/287 WEBS 3-8=-365/231, 2-9=-389/264, 4-7=-316/224 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 8-11-5, Exterior(2) 8-11-5 to 11-11-5, Interior(1) 11-11-5 to 15-9-9 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 6, 8 except (jt=lb) 9=153, 7=132. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss V17 Truss Type Valley Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49389002 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:07:05 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-e7zmmDDTv7dTIGVE24wdTPiL2x30RfZajZVZ3By6gpa Scale = 1:54.9 1 2 3 4 5 9 8 7 6 10 11 12 3x4 4x4 3x6 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 14-7-15 14-7-15 7-7-15 7-7-15 14-7-15 7-0-0 0-0-48-11-40-9-414.00 12 Plate Offsets (X,Y)-- [5:Edge,0-3-8] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.14 0.13 0.09 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 61 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-8 REACTIONS.All bearings 14-7-11. (lb) - Max Horz 1=170(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 1 except 9=-129(LC 14), 7=-138(LC 14) Max Grav All reactions 250 lb or less at joint(s) 1, 6 except 8=381(LC 19), 9=450(LC 19), 7=431(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-332/231, 4-7=-320/230 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 7-7-15, Exterior(2) 7-7-15 to 10-7-15, Interior(1) 10-7-15 to 14-6-3 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 9=129, 7=138. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss V18 Truss Type Valley Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49389003 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:07:06 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-6KX8zZE5gQlKwQ3QcnRs0dFX2LPRA6RjyDE6bdy6gpZ Scale = 1:46.0 1 2 3 4 5 8 7 6 9 10 11 123x4 4x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 0-0-3 0-0-3 12-8-15 12-8-12 6-4-8 6-4-8 12-8-15 6-4-8 0-0-47-5-40-0-414.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.12 0.11 0.11 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 49 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 12-8-9. (lb) - Max Horz 1=-136(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-112(LC 14), 6=-112(LC 14) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=325(LC 19), 8=367(LC 19), 6=367(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-299/218, 4-6=-299/219 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 6-4-8, Exterior(2) 6-4-8 to 9-4-8, Interior(1) 9-4-8 to 12-5-3 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 8=112, 6=112. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss V19 Truss Type Valley Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49389004 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:07:07 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-aW5WBvFjRktBYaed9Uy5ZqohcklDvZOtBt_g84y6gpY Scale = 1:37.6 1 2 3 45 8 7 6 9 10 11 12 3x4 4x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 10-1-14 10-1-14 10-2-2 0-0-3 5-1-1 5-1-1 10-2-2 5-1-1 0-0-45-11-40-0-414.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-S 0.13 0.08 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 36 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 10-1-11. (lb) - Max Horz 1=-107(LC 12) Max Uplift All uplift 100 lb or less at joint(s) except 1=-153(LC 12), 5=-137(LC 13), 8=-131(LC 14), 6=-131(LC 14) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=388(LC 19), 6=388(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-367/290, 4-6=-367/290 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 5-1-1, Exterior(2) 5-1-1 to 8-1-1, Interior(1) 8-1-1 to 9-10-5 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 153 lb uplift at joint 1, 137 lb uplift at joint 5, 131 lb uplift at joint 8 and 131 lb uplift at joint 6. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss V20 Truss Type Valley Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49389005 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:07:08 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-2ifuOFGLC2?29jDpjCUK52Ksv85Oe140PXjDgWy6gpX Scale = 1:29.1 1 2 3 4 5 6 7 8 3x4 4x4 3x4 1.5x4 7-7-1 7-7-1 7-7-4 0-0-3 3-9-10 3-9-10 7-7-4 3-9-10 0-0-44-5-40-0-414.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.16 0.08 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 25 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=7-6-13, 3=7-6-13, 4=7-6-13 Max Horz 1=-78(LC 12) Max Uplift 1=-17(LC 14), 3=-17(LC 14) Max Grav 1=175(LC 1), 3=175(LC 1), 4=214(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-13 to 3-3-13, Interior(1) 3-3-13 to 3-9-10, Exterior(2) 3-9-10 to 6-9-10, Interior(1) 6-9-10 to 7-3-7 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 17 lb uplift at joint 1 and 17 lb uplift at joint 3. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss V21 Truss Type Valley Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49389006 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:07:09 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-WuDGcbGzzL7vnto?Hv?ZeFt3DYSONUh9eBTnCyy6gpW Scale = 1:21.1 1 2 3 43x4 4x4 3x4 1.5x4 0-0-3 0-0-3 5-0-6 5-0-3 2-6-3 2-6-3 5-0-6 2-6-3 0-0-42-11-40-0-414.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.06 0.03 0.01 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-0-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=4-11-15, 3=4-11-15, 4=4-11-15 Max Horz 1=-49(LC 12) Max Uplift 1=-11(LC 14), 3=-11(LC 14) Max Grav 1=110(LC 1), 3=110(LC 1), 4=135(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 11 lb uplift at joint 1 and 11 lb uplift at joint 3. December 22,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 2102440 Truss V22 Truss Type Valley Qty 1 Ply 1 WILSON RESIDENCE - 20LV Job Reference (optional) I49389007 8.530 s Dec 6 2021 MiTek Industries, Inc. Tue Dec 21 17:07:09 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:?vHFxIYWgqOW5bi1x?oHeMy6hmT-WuDGcbGzzL7vnto?Hv?ZeFt1FYR6NUt9eBTnCyy6gpW Scale = 1:19.4 1 2 3 4 3x4 1.5x4 1.5x4 4-4-13 4-4-13 0-0-43-3-109.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2015/TPI2014 CSI. TC BC WB Matrix-P 0.19 0.12 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-4-13 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=4-4-8, 3=4-4-8 Max Horz 1=78(LC 11) Max Uplift 3=-14(LC 11) Max Grav 1=153(LC 1), 3=157(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-5-4 to 3-5-4, Interior(1) 3-5-4 to 4-3-1 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-10; Pr=20.0 psf (roof live load: Lumber DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (flat roof snow: Lumber DOL=1.15 Plate DOL=1.15); Category II; Exp B; Partially Exp.; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 14 lb uplift at joint 3. December 22,2021 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.21.The design does not take into account any dynamic or other loads other than those expressly stated.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3- 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths