HomeMy WebLinkAboutA210 Enlarged Floor PlanWORK AREA
MA
2174
Toilet
Existing
2145
Toilet
Existing
2144
HULTRASOUND
2172
MAIL
PRINT/
2170
UTILITY
SOILED
2171
TOILET
PATIENT
2173
Collection
2110
Collection
2109
Corridor
2104
COLLECTION
2111
BLOOD DRAW
2108
CONS
T
R
U
C
TI
O
N
NOT F
O
R
SHEET NO.DATE.DRAWN BY.CHECKED BY.CERTIFIED BY.DECEMBER 14, 2021TGJCOPYRIGHT: Architects Forum, LLC expressly reserves the common
law copyright and other property rights in these plans. These plans
are not to be reproduced in any form or manner, nor assigned to any
third party, without first obtaining the expressed permission and
consent of Architects Forum, LLC.PROJ. NO. 21630MRG8555 North River Road .Suite 220 . Indianapolis . Indiana . 46240[p] 317. 842.8500 [f] 317.842.8877Carmel, Indiana 4603212188-A North Meridian Street, Suite 250MIDWEST FERTILITYEXPANSION01
A201
Enlarged Floor Plan
Scale: 1/4" = 1'-0"NA. ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE
WITH ALL APPLICABLE CODES, LAWS AND ORDINANCES.
B. ALL DIMENSIONS ARE FROM FACE OF STUD, OR COLUMN
CENTERLINE. ANY DIMENSIONS NOT SHOWN OR DEEMED
QUESTIONABLE ARE TO BE VERIFIED BY ARCHITECT. DO NOT
SCALE DRAWINGS.
C. CONTACT RESPECTIVE UTILITY COMPANY FOR EXACT
LOCATION OF SERVICES PRIOR TO START OF
CONSTRUCTION. PROTECT ANY EXISTING SERVICE DURING
CONSTRUCTION.
D. REFERENCE MEP DRAWINGS FOR ALL MECHANICAL,
PLUMBING AND ELECTRICAL REQUIREMENTS.
E. SEE WALL TYPE LEGEND FOR WALL CONSTRUCTION.
F. PROVIDE FIRE TREATED WOOD BLOCKING SUPPORT AT ALL
SURFACE MOUNTED ITEMS AS REQUIRED.
G. DOOR AND FRAME NUMBERS CORRESPOND TO ROOM
NUMBERS. WHERE MORE THAN ONE DOOR OCCURS IN A
ROOM, A SUFFIX HAS BEEN ADDED (I.E. 1000A). REFERENCE
DOOR SCHEDULE.
H. CAULK ALL JUNCTURES BETWEEN DIFFERENT MATERIALS -
TYPICAL. (I.E. STOREFRONT AND GYPSUM WALLBOARD).
I. ALL STEEL STUDS ARE TO BE BRACED ACCORDING TO
MANUFACTURER'S LIMITING HEIGHT L/ OVER 240.
J. ALL METAL STUD WALLS WHICH EXTEND TO DECK SHALL BE
CONSTRUCTED WITH A CONTINUOUS SLIP TRACK AT TOP OF
WALL. TRACK SHALL BE SIZED TO ALLOW FOR MINIMUM DECK
DEFLECTION OF 1/2".
K. EACH CONTRACTOR SHALL PROVIDE ALL BARRICADES, ETC.
AS REQUIRED BY LAW, CODE OR ORDINANCE AND AS
OTHERWISE REQUIRED.
L. REMOVE ALL TRASH AND DEBRIS FROM THE JOB SITE DAILY.
M. PROVIDE WALL MOUNTED FIRE EXTINGUISHERS AND/OR
CABINETS AS REQUIRED BY CODE. CONFIRM FINAL LOCATION
AND QUANTITY WITH LOCAL AUTHORITIES
N. PROVIDE MOISTURE RESISTANT GYPSUM WALLBOARD IN ALL
KITCHEN AREAS, TOILET ROOMS, AND WET AREAS UNLESS
INDICATED TO BE TILE BACKER BOARD.
O. PROVIDE GYPSUM WALLBOARD ON INTERIOR SIDE OF
EXTERIOR WALL CONSTRUCTION ALONG PERIMETER OF
TENANT SPACE.
PLAN NOTES
GENERAL PLAN NOTES
NEW SEMI-RECESSED FIRE EXTINGUISHER CABINET.
CONFIRM REQUIRED QUANTITY AND FINAL LOCATIONS WITH
LOCAL AUTHORITIES.
ALIGN NEW WALL CONSTRUCTION WITH EXISTING WALL.
NEW PLUMBING FIXTURE LOCATION. REFERENCE MEP
DRAWINGS.
CASEWORK AND / OR COUNTERTOP LOCATION. REFERENCE
INTERIOR ELEVATIONS, FINISH SCHEDULE, AND DETAILS.
PROVIDE COAT HOOK ON INTERIOR SIDE OF DOOR.
OWNER FURNISHED COPIER / PRINTER LOCATION, PROVIDE
DEDICATED ELECTRICAL CIRCUIT.
PROVIDE BLOCKING IN WALL FOR WALL-MOUNTED MONITOR
SUPPORT. COORDINATE EXACT LOCATION WITH TENANT AND
REFERENCE ELECTRICAL DRAWINGS.
PROVIDE FULL HEIGHT BLOCKING TO SECURE LIQUID
NITROGEN STORAGE CONTAINERS TO WALL.
INSTALL NEW STAINLESS STEEL PASS-THRU CABINET
EXISTING REFRIGERATOR LOCATION.
LIQUID NITROGEN STORAGE CYLINDER LOCATION.
MODIFY EXISTING CASEWORK TO ACCOMMODATE NEW
WORK.
1
2
3
4
5
6
7
* ALL WALL TYPES SHALL BE W1 UNLESS NOTED OTHERWISE.
* FOR WALL HEIGHTS, REFERENCE REFLECTED CEILING PLANS.
8
9
10
12
11 4 7/8"4 1/4"EXISTING WALL TO REMAIN.
3-5/8" x 20 GA. METAL STUDS AT 16"
O.C. WITH 5/8" GYPSUM WALLBOARD
EACH SIDE AND SOUND ATTENUATION
BLANKETS IN EACH STUD CAVITY.
3-5/8" x 20 GA. METAL STUDS AT 16"
O.C. WITH 5/8" GYPSUM WALLBOARD
ONE (1) SIDE.
5-5/8" x 20 GA. METAL STUDS AT 16"
O.C. WITH 5/8" GYPSUM WALLBOARD
ONE (1) SIDE AND SOUND
ATTENUATION BLANKETS IN EACH
STUD CAVITY.
WALL TYPE LEGEND
EX
W1
W2 6 1/4"W1
A210ENLARGED PLANS8'-05
8"3'-43
4"12'-8"4'-1"3'-115
8"11'-35
8"
08
A700
06
A600
07
A600
05
A600
3'-83
8"
4'-81
4"2'-11" 1'-6"3'-11"2'-3"
02
A700
01
A700
02
A201
Enlarged Floor Plan
Scale: 1/4" = 1'-0"N7'-43
8"
7'-71
4"7'-1078"4'-6"12"
MIN.
18"
MIN.18"MIN.18"
MIN.
8'-0"5'-2"12"
MIN.
01
A205
W1 W1 W1W1W1
W1
W1
W1
W102
A600
03
A600
01/13/22