HomeMy WebLinkAboutLS001 Life SafetyIVF Lab
Procedure
StorageEmbryo
IVF Storage
Hold 1
Corridor
Sterile
Hold 2
Hold 3
Hold 4
Nurse
Station
Corridor
ICSI
PGD
Utility
Soiled
Utility
Soiled
Women
Jan.Storage
2132
2124
2131
2130
2134
2136
2127
2133
2135
2128
2129
2169
2120
2118
2121
2123
2122
2126
Jan.
2174
201
Elevator Lobby
204
Women
205
Men
Data
207
Tele/207202Janitor
202 203
Alcove204 210205
Electrical206
206
Stair #3
210
T.CABLESELECTORHST.CABLESW. TREESELECTORSW. TREEElevator 2
103
Elevator 1
104
Stair #1
308
Physician Office
2114
Main Lab
2112
OFFICE
2113B
OFFICE
2113A
Collection
2110
Collection
2109
Corridor
2104
Corridor
2105
OFFICE
PHYSICIAN
2166
Office #3
Physician
2164
Office #2
Physician
2163
WORK AREA
MA
2174
Reception
2305
Waiting
2301
Toilet
Staff
2304
CONSULT #1
2155
CONSULT #2
2154
CONSULT #3
2153
CONSULT #5
2307
CONSULT #6
2306
OFFICE
2303
OFFICE
2302
Physician Office #1
2161
Toilet
2135
Existing
Ultrasound
Existing
2143
Ultrasound
Existing
2142
Toilet
Existing
2145
Toilet
Existing
2144
Check-In
2103
Waiting
2102
Check-Out
2101
Corridor
2138
Corridor
2116
Corridor
2171
Break Area
2168
Office
Manager
2141
Patient Exit
2139
Exam #4
2147
Exam #3
2148
Corridor
2146
Lab
Existing
2152
Corridor
2115
Trash
Biohazard
2117
Weigh-In
2106
Corridor
2162
Mech/Elec
2167
Data
2166
HOFFICE
PHYSICIAN
2165
Exam #1
2144
Exam #2
2145
Toilet
Existing
2137
Toilet
Existing
2140
IVF Workroom
2119
Men
2170
WORK AREA
NURSE
2156
WORK AREA
NURSE
2157 Third Party Office
2160
Office
2159CONSULT #4
2152
ULTRASOUND
2172
MAIL
PRINT/
2170
UTILITY
SOILED
2171
TOILET
PATIENT
2173
COLLECTION
2111
BLOOD DRAW
2108
Transfer Rm
2125
Corridor
2162A
MIDWEST FERTILITY : TENANT IMPROVEMENTDECEMBER 14, 2021 - PERMIT SETEXISTING BUILDING (UNCHANGED) ±88,878 SF
BUILDING GROSS SQUARE FOOTAGE:
TOTAL RENOVATION SF ±8,347 SF
RENOVATION SQUARE FOOTAGE:
EXISTING: V-B, FULLY SPRINKLED (UNCHANGED)
CONSTRUCTION TYPE:
OCCUPANCY:
1005.3.2 - .15" PER PERSON CAPACITY, SPRINKLERED
REQUIRED PROVIDED
SECOND LEVEL - 83 OCCUPANTS X .15" 12.45" 72"
SECOND FLOOR MAXIMUM TRAVEL DISTANCE (TABLE 1016.2) = 300'
(B OCCUPANCY WITH SPRINKLER)
EXISTING CORRIDOR CONSTRUCTION (TABLE 1018.1)
(B OCCUPANCY WITH SPRINKLER) = NON RATED
MAXIMUM DEAD END CORRIDOR (TABLE 1018.4) = 50'-0"
EGRESS:
ELECTRICAL PANEL LOCATIONEP
EXIT - BUILDING STAIR LOCATIONEX
FE FIRE EXTINGUISHER LOCATION
EXIT SIGNAGE LOCATION
EMERGENCY LIGHTING
PATH OF EGRESS, MAXIMUM TRAVEL DISTANCE
OCCUPANCY CLASSIFICATION:
GROUP B, EXISTING (BUSINESS)
OCCUPANT CALCULATION (FIXED TABLE 1004.1.2):
RENOVATED SF = 8,347 SF / 100 SF PER PERSON 83 PERSONS
APPLICABLE CODES:
ALL WORK UNDER THIS CONTRACT SHALL COMPLY WITH THE
PROVISIONS OF THE SPECIFICATIONS & DRAWINGS AND SHALL
SATISFY ALL APPLICABLE CODES, ORDINANCES, A.D.A., AND
REGULATIONS OF ALL GOVERNING BODIES INVOLVED.
ALL PERMITS AND LICENSES NECESSARY FOR THE PROPER
EXECUTION OF THE WORK SHALL BE SECURED AND PAID FOR BY
THE CONTRACTOR INVOLVED.
THE FOLLOWING CODES AND REGULATIONS ARE CURRENTLY
ADOPTED BY THE STATE OF INDIANA AT THE TIME A BUILDING
PERMIT IS APPLIED FOR:
BUILDING CODE: INDIANA BUILDING CODE 2014
(INTERNATIONAL BUILDING CODE 2012
WITH INDIANA AMENDMENTS)
MECHANICAL CODE: INDIANA MECHANICAL CODE 2014
(INTERNATIONAL MECHANICAL CODE 2012
WITH INDIANA AMENDMENTS)
ELECTRICAL CODE: INDIANA ELECTRICAL CODE 2009
(NATIONAL ELECTRICAL CODE 2008
- NFPA 70 WITH INDIANA AMENDMENTS)
PLUMBING CODE: INDIANA PLUMBING CODE 2012
(UNIFORM PLUMBING CODE 2006)
FIRE CODE:INDIANA FIRE CODE 2014
(INTERNATIONAL FIRE CODE 2012
WITH INDIANA AMENDMENTS)
ENERGY CODE: INDIANA ENERGY CONSERVATION CODE
2010 (ASHRAE 90.1- 2007 WITH INDIANA
AMENDMENTS)
FUEL GAS CODE: INDIANA FUEL GAS CODE 2014
(INTERNATIONAL FUEL GAS CODE 2012
WITH INDIANA AMENDMENTS)
ACCESSIBILITY CODE: INDIANA BUILDING CODE 2014, CHAPTER 11
(ICC/ANSI A117.1-2009 ACCESSIBLE AND
USABLE BUILDINGS AND FACILITIES)
CODE SUMMARY
ARCHITECT:
ARCHITECTS FORUM
8555 North River Road, Suite 220
Indianapolis, Indiana 46240
[P] 317.842.8500
[F] 317.842.8877
MEP ENGINEER :
COVER SHEET / CODE INFORMATION
ARCHITECTURAL
A200 SECOND LEVEL DEMOLITION PLAN
A201 SECOND LEVEL FLOOR PLAN
A202 SECOND LEVEL REFLECTED CEILING PLAN
A203 SECOND LEVEL FINISH PLAN
A204 SECOND LEVEL FURNITURE AND EQUIPMENT PLAN
A205 ENLARGED RESTROOM PLAN AND ELEVATIONS
A210 ENLARGED FLOOR PLANS
A500 DOOR SCHEDULE AND DETAILS
A600 INTERIOR ELEVATIONS
A700 CASEWORK SECTIONS AND DETAILS
ELECTRICAL
MECHANICAL
PLUMBING
N
MAP
PROJECT LOCATION
LIFE SAFETY LEGEND
CODE INFORMATION SHEET INDEX
CONSTRUCTION TYPE: V-B EXISTING, SPRINKLERED
USE GROUP: GROUP B
12188-A N MERIDIAN STREET, SUITE 250
CARMEL, INDIANA 46032
TENANT IMPROVEMENT
SCALE: 1/8" = 1'-0"
OVERALL LIFE SAFETY PLAN
NorthMIDWEST FERTILITY
OWNER:
WELLTOWER MERIDIAN MOB A
12188A N MERIDIAN ST,
Carmel, Indiana 46032
EXIT
EXISTING
LINE OF 75' FIRE
EXTINGUISHER
RADIUS
EXIT
EXISTING
SHADED AREA
NOT IN PROJECT
SCOPE
SHADED AREA
NOT IN PROJECT
SCOPE
OWNER:
MIDWEST FERTILITY
12188-A N Meridian Street, Suite 250
Carmel, Indiana 46032
[P] 317.571.1637
CONTRACTOR:
MAYER NAJEM
11787 Lantern Road, Suite 100
Fishers, Indiana 46032
[P] 317.577.0007
[F] 317.577.0286
FE
FE
01/13/22