HomeMy WebLinkAboutA200 Second Floor DemoIVF Lab
Procedure
StorageEmbryo
IVF Storage
Hold 1
Corridor
Sterile
Hold 2
Hold 3
Hold 4
NurseStation
Corridor
ICSI
PGD
UtilitySoiled
Women
Jan.Storage
2132
2124
2131
2130
2134
2136 2133
2135
2128
2129
2169
2120
2118
2121
2123
2122
2126
Jan.
2174
201
Elevator Lobby
204
Women
205
Men
Data
207
Tele/207202Janitor
202 203
Alcove204 210205
Electrical206
206
5.7 6 7 7.3 7.7 8 9 10 11 10.8 11.3
F
E
D.3
D
C.4
C
B
A
12 12.1
Stair #3
210
6.2 6.8 T.CABLESELECTORHST.CABLESW. TREESELECTORSW. TREEElevator 2
103
Elevator 1
104
Stair #1
308
Office
2171
Shared
Physician Office
2114
Main Lab
2112
Office
2111
Collection
2110
Collection
2109
Office
2108
Office
2113
Corridor
2104
Corridor
2105
Office #3
Physician
2164
Office #2
Physician
2163
Toilet
2172
Reception
2305
Waiting
2301
Toilet
Staff
2304
Consult
2303
Exam
2302
Office
2306
Exam
2307
Physician
2152
Nurse
2153
Nurse
2154
Nurse
2155
Consult
2156
Consult
2157 Physician Office #1
2161
Toilet
2135
Existing
Ultrasound
Existing
2143
Ultrasound
Existing
2142
Toilet
Existing
2145
Toilet
Existing
2144
Check-In
2103
Waiting
2102
Check-Out
2101
Corridor
2138
Corridor
2116
Corridor
2171
Break Area
2168
Office
Manager
2141
Patient Exit
2139
Exam #4
2147
Exam #3
2148
Corridor
2146
Lab
Existing
2152
Corridor
2115
Trash
Biohazard
2117
Weigh-In
2106
Corridor
2162
Mech/Elec
2167
Data
2166
Office
Business
2165
Exam #1
2144
Exam #2
2145
Toilet
Existing
2137
Toilet
Existing
2140
IVF Workroom
2119
Men
2170
Third Party Office
2160
Office
2159
Transfer Rm
2125
Corridor
2162A
CONS
T
R
U
C
TI
O
N
NOT F
O
R
SHEET NO.DATE.DRAWN BY.CHECKED BY.CERTIFIED BY.DECEMBER 14, 2021TGJCOPYRIGHT: Architects Forum, LLC expressly reserves the common
law copyright and other property rights in these plans. These plans
are not to be reproduced in any form or manner, nor assigned to any
third party, without first obtaining the expressed permission and
consent of Architects Forum, LLC.PROJ. NO. 21630MRG8555 North River Road .Suite 220 . Indianapolis . Indiana . 46240[p] 317. 842.8500 [f] 317.842.8877Carmel, Indiana 4603212188-A North Meridian Street, Suite 250MIDWEST FERTILITYEXPANSION01
A200
Second Level Demolition Plan
Scale: 1/8" = 1'-0"NA. COORDINATE EXTENT OF DEMOLITION WORK WITH ALL NEW
CONSTRUCTION, AS INDICATED IN CONTRACT DOCUMENTS.
B. THESE DEMOLITION NOTES REPRESENT SURVEYED SPACES
BEFORE DEMOLITION WORK. LOCATION OF CASEWORK,
COUNTERS, ETC. WITHIN THESE DOCUMENTS MAY NOT BE
COMPLETELY ACCURATE.
C. FIELD VERIFY EXACT SIZES AND LOCATION OF ALL EXISTING
WORK PRIOR TO CONSTRUCTION. CONTACT THE ARCHITECT
IN THE EVENT OF CONFLICTS.
D. ALL DEMOLITION ITEMS SHALL BE CONSIDERED PROPERTY
OF THE OWNER UNTIL VERIFICATION HAS BEEN MADE AS TO
ITEMS TO BE RETAINED, PRIOR TO REMOVAL FROM THE SITE.
ALL ITEMS NOT TO BE RETAINED SHALL BE REMOVED FROM
THE SITE BY THE CONTRACTOR.
E. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS
TO INSURE THAT THE BUILDING REMAINS WATERTIGHT AND
SECURE AT ALL TIMES.
F. CONTRACTOR SHALL PROVIDE ALL TEMPORARY PARTITIONS
AND DOORS AS DEEMED NECESSARY BY ARCHITECT AND
OWNER TO AVOID MIGRATION OF DUST INTO ADJOINING AND
OCCUPIED AREAS.
G. PROTECT ALL EXISTING STRUCTURAL SUPPORTS.
H. MAKE ALL DEMOLITION CLEAN AND COMPLETE AND IN A
MANNER SUITABLE TO ACCEPT NEW FINISHES AND/OR
SURFACES.
I. WHEN DEMOLITION CAUSES OR EXPOSES DAMAGE TO
EXISTING SLAB, FLOOR, WALL OR CEILING SURFACES WHICH
WILL REMAIN EXPOSED IN THE FINISHED WORK, THE
CONTRACTOR SHALL REPAIR AND LEVEL SUCH CONDITIONS
AS REQUIRED.
J. REMOVE EXISTING FLOOR, WALL AND CEILING FINISHES
WITHIN BOUNDARY OF PROJECT SUITE. PROTECT ALL
EXISTING CORRIDOR INTERIOR FINISHES TO REMAIN.
K. WHERE ANY EXISTING PIPING OR DUCTWORK IN FLOORS,
WALLS OR CEILINGS IS TO BE REMOVED OR RELOCATED, FILL
IN PENETRATION OPENINGS FLUSH WITH AND OF THE SAME
MATERIALS.
L. REFERENCE STRUCTURAL, MECHANICAL, PLUMBING AND
ELECTRICAL DEMOLITION DRAWINGS FOR ADDITIONAL
INFORMATION.
M. REMOVAL OF ANY ASBESTOS IS THE RESPONSIBILITY OF THE
OWNER. NOTIFY THE ARCHITECT IF SUCH MATERIAL IS
DISCOVERED DURING DEMOLITION OPERATIONS.
N. DASHED LINES INDICATE TO REMOVE WALLS, DOORS,
FRAMES AND ASSOCIATED ITEMS COMPLETE.
P. ALL EXISTING WINDOW BLINDS ARE TO BE PROTECTED
THROUGHOUT CONSTRUCTION PROCESS.
DEMOLISH EXISTING WALL CONSTRUCTION COMPLETE.
DEMOLISH PORTION OF EXISTING WALL AS REQUIRED TO
ACCOMMODATE NEW CONSTRUCTION. PATCH AND REPAIR
ALL EXISTING ADJACENT SURFACES TO REMAIN.
REMOVE EXISTING FRAME, DOOR, AND / OR WINDOW
COMPLETE.
EXISTING FRAME, DOOR, AND/OR WINDOW TO REMAIN.
PROTECT DURING ALL PHASES OF CONSTRUCTION.
DEMOLISH EXISTING FLOOR FINISHES COMPLETE. PREPARE
AND LEVEL EXISTING SURFACE TO RECEIVE NEW FINISHES.
REMOVE EXISTING PLUMBING FIXTURE.
PASS THRU SLIDING OPERABLE WINDOW AT CHECK IN.
EXISTING FLOORING TO REMAIN. PROTECT DURING ALL
PHASES OF CONSTRUCTION.
PATCH AND REPAIR FLOORING INDIVIDUAL TILES.
MODIFY EXISTING CASEWORK AS REQUIRED PER FLOOR
PLANS.
REMOVE ACOUSTICAL CEILING TILE FOR REPLACEMENT.
PROTECT GRID.
DEMOLISH EXISTING BULKHEAD CONSTRUCTION
GENERAL DEMOLITION NOTES
CONTAMINATION PREVENTION
DEMOLITION LEGEND
DEMOLITION PLAN NOTES
1
2
3
4
5
6
· THE PROJECT CONSTRUCTION AREA SHALL BE ISOLATED
WITH RIGID, DUST-PROOF, FIRE RATED BARRIER WALLS AND
A GASKETED DOOR AT ENTRY LOCATIONS AND WALL
PENETRATIONS.
· THE TEMPORARY WALLS SHALL BE OF CLEAN,
PROFESSIONAL APPEARANCE FOR VIEW FROM PATIENTS
AND VISITORS.
· THE TEMPORARY WALLS SHALL BE SOUND REDUCING
WHERE POSSIBLE.
· DESIGNATED ENTRY AND EXIST PROCEDURES SHALL BE
DEFINED WITH EGRESS PATHS KEPT FREE AND DEBRIS.
TEMPORARY SIGNAGE SHALL BE INSTALLED TO DIRECT
PEDESTRIAN TRAFFIC AWAY FROM THE CONSTRUCTION
AREA.
· AIR SYSTEM FLOW SHALL BE NEGATIVE TO THE
SURROUNDING AREAS AND VENTILATED AS REQUIRED TO
PREVENT ENVIRONMENTAL CONTAMINATION. EXISTING
VENTS TO REMAIN OPERATIONAL DURING CONSTRUCTION
SHALL BE COVERED WITH HEPA FILTER MATERIAL.
· COORDINATE WITH OWNER'S INFECTION CONTROL
ADMINISTRATOR TO INTEGRATE ICRA CLASS IV INFECTION
PREVENTION PROCESS AND PROVIDE DOCUMENTATION.
DASHED LINE INDICATES TO REMOVE EXISTING
WALL CONSTRUCTION, DOOR OR WINDOW
ASSEMBLY, CASEWORK, FIXTURES, ETC.
COMPLETE.
7
8
9
10
11
12
2
2
2
2 2
3
2
3
3
6 3
4
TYP
4
TYP
4
TYP
3
3
2
3
3
2
3
5
8
6
8 8
8
8
5 5 5
5
5
5
7
7
7
8 8
88
8
8
8
5
5
5
5
8
5
A200SECOND LEVELDEMOLITION PLAN9
1
11
2 22
3
2
2
3
3
3
2
3
10 10
10
5 55
55
5
5
5 5 5 5 5
11
5 11
5 11
5 11
5 11
5 11
5 11
5 11
5 11
12 12
12
121212
5
12
01/13/22