Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Civil_C0.1
EXISTINGBUILDING1 STY. CONCRETE BLOCK10,133 SQ. FEETEX. CONCRETES 90°00'00" E475.01'N 76°47'08" W499.98'N 00°12'00" E 414.21' S 01°06'55" E 528.61'10' AMERITECH EASEMENTIN.#'9709748111, B-2(#14)30' DRAIN. ESMT.PER PLAT30' DRAIN.ESMT.PER PLATEX. RIGHT-OF-WAY80.00'I./E/ ESMT.15' B.S.L.15' B.S.L.15' B.S.L.15' B.S.L.75' U.&D.E.U.&D.E. & S.EPER PLAT.POND15' U.& D.E. & TCG ESMT.IN.#'9809839555ASPH. PAVEMENTASPH. PAVEMENTASPH. PAVEMENT602.58'P.O.B.PK NAIL FOUND FLUSHRETAINING WALLPONDPK NAILFOUND FLUSH CAPPED REBAR FOUND FLUSHAT PROP. CORNERMSE CAPPED REBAR FOUND FLUSH0.38' EAST & 0.12' SOUTH OF PROP. CORNERWOODSWOODSWOODSWOODS24.9'36.2'ASPH. PAVEMENTASPH. PAVEMENTLOT 3 BLOCK 1Area less Exception:4.953 Ac.+/-LOT 2 BLOCK 1 -MAYFLOWER PARKMORIDEN AMERICA INC.INST. NO. 2014-45483IRVING MATERIALS, INC.INST. NO. 9913085LOT 1 BLOCK 7PERFORMANCE SERVICESREAL ESTATE LLCINST. #2015-25148 Glennco Realty LLCEXISTING SWALESite Address: 9650Mayflower Park DriveCarmel, Indiana 4603298.0'96.8'147.9'125116850.5'2.6'T1017.59'N 00°12'00" E 50.00'S 90°00'00" E70.00'S 90°00'00" E10.00'N 00°12'00" E 380.95'.73.25'426.73'Dotted area indicates the "Exception to Parcel 1 Area - 0.605 Acres+/-30' GAS LN.ESMT.INST. #9709741841B-2(#12)WMTKRUSE PROPERTIES, LLC.INST. NO. 2007-19093MAYFLOWER PARKASSOC.BUILDING HT.: 34.7'STMR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W111222222213345677DEMOLITION LEGENDPROPOSEDEXISTINGGENERAL NOTES:1.DISPOSE OF CONSTRUCTION DEBRIS OFF-SITE IN ACCORDANCE WITHLOCAL CODES.2.REMOVE AND DISPOSE OF ON SITE FEATURES AS SHOWN ON THE PLAN.3.SAW-CUT EXISTING PAVEMENT AT LIMITS OF PAVEMENT REMOVAL TOFULL DEPTH USING CARE TO CUT NEAT, STRAIGHT LINES. CUT ATEXISTING JOINTS WHERE POSSIBLE.4.CONTRACTOR TO PROTECT EXISTING SITE FEATURES TO REMAINOUTSIDE CONSTRUCTION LIMITS. REPAIR ANY DAMAGE TO THESATISFACTION OF THE OWNER AT NO ADDITIONAL COST.5.CONTROL DUST AT THE SITE. PROVIDE STREET CLEANING WHENNECESSARY, AND WHEN REQUESTED BY OWNER.6.GRADE SITE DURING CONSTRUCTION TO PROVIDE POSITIVE DRAINAGETO EXISTING AND/OR PROPOSED STORM WATER MANAGEMENTSYSTEMS.7.PERFORM WORK IN ACCORDANCE WITH LOCAL CODES ANDREGULATIONS.CODED NOTES:X1.PROTECT EXISTING PAVEMENT/SIDEWALK TO REMAIN.2.PROTECT EXISTING CONCRETE CURB TO REMAIN.3.SAWCUT EXISTING PAVEMENT WITH NEAT, STRAIGHT LINES. MATCHEXISTING PAVEMENT GRADE AT THIS POINT.4.PROTECT EXISTING UTILITY STRUCTURE TO REMAIN. ADJUST TO FINALGRADE.5.COVER EXISTING PAVEMENT MARKINGS WITH 2 COATS OF BLACK PAINTAND RESTRIPE.6.CONTRACTOR TO COORDINATE WITH OWNER TO REMOVE/RELOCATEEXISTING SIGN.7.REMOVE EXISTING SIGN AND ASSOCIATED FOUNDATION.0GRAPHIC SCALESCALE IN FEET306090REMOVE EXISTING ASPHALT, GRAVEL, ANDCONCRETE PAVEMENT, CONCRETESIDEWALK, BUILDING FOUNDATION, ANDPAVEMENT BASE MATERIALSREMOVE AND REPLACEPAVING IN KINDREMOVE EXISTING TREEPROTECT EXISTING TREE TO REMAINREMOVE EXISTING CONCRETECURBSAVEREFER TO SHEET TOPOGRAPHIC SURVEYREVISION:PROJECT NUMBER:20297Sheet Name:© 2021 M+A Architects12 JANUARY 2022DATE:SHEET NUMBER:VOLUME1 - SITEWORK AND FOUNDATIONS MEDVET CARMEL - ANIMAL HOSPITAL <650 MAYFLOWER PARK DRIVE | CARMEL, IN 46032 |>STATUS:PROJECT NUMBER:CHECKED BY:DESIGNED BY:1650 WATERMARK DRIVECOLUMBUS, OHIO 43215SUITE 200DRAWN BY:2021-0012DEMOLITION PLANC0.1XXXElijah Mehan