Loading...
HomeMy WebLinkAboutStructural_S5.01SEE PLAN 3" DP. MTL. ROOF DECK 3"3"3"3"AISC STD SHEAR CONN. W/ 3/4"Ø A325 BOLTS EL. T.O.STL. AISC STD DBL. ANGLE CONN. W/ 3/4"Ø A325 BOLTS. TYP. AT COLUMNS 3" DP. MTL ROOF DECK SEE PLAN EL. T.O.STL. SEE COLUMN SCHEDULE 3"3"3"3"C6x8.2 (4 SIDES) 3" DP. METAL ROOF DECK C6 EL. T.O.STL. CLIP L'S; SHOP WELDED TO CHANNELS (TYP.) SEE PLAN SEE PLAN NEAR HEADER FAR HEADER CHANNEL EACH SIDE OF OPNG. CLIP L w/ (1) 3/4"Ø ERECTION BOLT CHANNELS TO BE C5x6.7 IF LESS THAN 12 INCHES, NEAR HEADER CAN BE ELIMINATED. SEE HVAC. OR ARCH. DWG'S FOR SIZE, LOCATION & QUANTITY STRUCT CONCEPTUAL DESIGN FOR REVIEW SCHEMATICS DESIGN DEVELOPMENT WORKING DRAWINGS NOT FOR CONSTRUCTION PROJECT NUMBER: CHECKED BY: DESIGNED BY: 1650 WATERMARK DRIVE COLUMBUS, OHIO 43215 SUITE 200 DRAWN BY:PRELIMINARYNOT FOR CONSTRUCTION© 2021 M+A Architects PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: PROJECT NUMBER: Sheet Name: DATE: SHEET NUMBER: REVISION: STATUS: 2021-0012 <YYYY.XXX> ROOF DETAILS DD MONTH YYYY S5.01MEDVET CARMEL - ANIMALHOSPITAL<650 MAYFLOWER PARK DRIVE | CARMEL, IN 46032 |>VOLUME1 - SITEWORK AND FOUNDATIONS NEB JPF WRH 0'6"1'2'3" SCALE: 3/4" = 1'-0"11 SECTION 0'6"1'2'3" SCALE: 3/4" = 1'-0"12 SECTION 0'6"1'2'3" SCALE: 3/4" = 1'-0"13 SECTION TYP. FRAMING AT ROOF OPENINGS