HomeMy WebLinkAboutA002 Accessibility Details5'-0"
2'-0"
MIN
4"
MAX
3'-0"OTHER APPROACHES4'-0" MIN HINGEAPPROACH3'-6" MIN LATCHAPPROACH ONLY5'-0" MIN4'-6" MIN3'-3" MIN3'-5" MAX12"MAX16" TO 18" MAX
TOILET PAPER
VERTICAL GRAB
BAR - SEE DET 1
1'-0"
MIN
3'-0"
MIN
CL TOILET
48" MIN 30" MIN15" MINCLEAR
FLOOR
SPACE15" MIN48" MIN 30" MIN15" MINCLEAR
FLOOR
SPACE
112"
CLR
GRAB BAR SHALL BE 1 14" TO 2"
MAX OUTSIDE DIA TYPICAL
2 - 14" X 3" EXPANSION ANCHORS
AT MASONRY OR CONCRETE WALL.
2 - #10 X 2" SCREWS AT WOOD OR
STEEL STUD WALL - TYPICAL.
STUD WALL
2" X 6" BLOCKING (OMIT BLOCKING AT
MASONRY OR CONCRETE WALL)ACCESSIBLE ROUTE30"
CLEAR
19" 30"CLEARACCESSIBLE ROUTE
30"
CLEAR
19"
NOTE:MAINTAIN 44" MIN CLEAR AISLE
EGRESS PATHS TO EXIT DOORS.30"CLEAR48"
CLEAR
80" MIN36" MIN CLEAR
ACCESSIBLE ROUTE
2'-3"PROTRUDING OBJECT
FREESTANDING OBJECT
MOUNTED ON POSTS OR
PYLON MAY OVERHANG
12" MAX FROM 27" TO 80"
ABOVE FINISH FLOOR
OBJECT PROJECTION FROM
WALL BETWEEN 27" TO 80"
ABOVE FINISH FLOOR SHALL
PROTRUDE NO MORE THAN 4"
OBJECT PROJECTION FROM WALL
LESS THAN 27" ABOVE FINISH FLOOR
MAY PROTRUDE ANY AMOUNT
FLOOR SHALL BE SLIP-RESISTANT
SURFACE AND LEVEL WITH MAX
14" CHANGE IN LEVEL
BACK WALL
27" MAX
CONTROLS SIDE WALL6"
MAX
6"MAXSIDE WALLBACK WALL
48" MAXCONTROLS48" MAX TOHIGHEST OPERABLE PART44" MAX17" MAX39" TO 41"
6" TO 12" MAX
17" TO 19"7" TO
9"
2'-0"39" TO 41"1 1/2"MIN34" MAX29" MIN27" MIN12"MIN17"15"-18"SWITCHES
THERMOSTAT
FIRE ALARM
OUTLETS (UON)DRYER
PAPER TOWEL DISPENSER
PULL STATION
MIRROR MOUNTED @ 40"
AFF MAX TO BOTTOM OF
REFLECTING SURFACE
LAVATORY
INSULATE HOT WATER
& DRAIN PIPES
13 12" MIN PROJECTION
FROM WALL URINAL
6" MAX DEPTH X 30" MIN
WIDTH TOE CLEARANCE
8" MIN DEPTH X 30" MIN
WIDTH KNEE SPACE
15" TO 48" AFF FOR
OPERABLE OPENING
W/O OBSTRUCTION
FROM GRAB BAR
VERTICAL SS GRAB BAR
TOILET SEAT COVER
DISPENSER SHALL BE
MOUNTED 1 12" (MIN)
BELOW GRAB RAIL
42" SS GRAB BAR
36" SS GRAB BAR
33" (EXCEPT @ TANK
TOILETS, WHICH SHALL
BE 36"
NOTES:
1. TOP OF GRIPPING SURFACE 33" TO 36" MAX
- SEE NOTES BELOW
2. 12" MINIMUM CLEAR ABOVE GRAB BAR
TACTILE CHARACTERS48" MIN TO 60" MAX4" 3'-4"TO REFLECTIVE SURFACECONTROLS MOUNTED ON
WIDE SIDE OF TOILET AREA
2
1 1/4" - 1/2"1/4" MAX46" MAX48" MAX WITH NOOBSTRUCTION TOREACH OVER24"
MAX
24"
MAX
30" 34" MAX46" MAX10"
MAX
30" 15"MIN48" MAXWATER CLOSET: WATER CLOSETS SHALL BE 17" TO 19" AFF WHEN
MEASURED TO THE TOP OF THE TOILET SEAT AND THE CENTER FOR THE
FIXTURE SHALL BE 18" FROM ONE WALL WITH A CLEAR FLOOR SPACE OF
60" WIDE AND 59" DEEP FOR FLOOR MOUNT AND 56" DEEP FOR WALL
MOUNT. FLUSH CONTROLS SHALL BE LOCATED ON THE OPEN SIDE OF
THE WATER CLOSET.
SINK: SINK SHALL BE MOUNTED WITH THE RIM OR COUNTER NO HIGHER
THAN 34" AFF PROVIDE A CLEARANCE OF AT LEAST 29" TO THE BOTTOM
OF THE APRON WITH AN 8"X27" KNEE SPACE AND 6"X9" TOE SPACE.
EXPOSED HOT WATER AND DRAIN PIPES UNDER SINKS SHALL BE
INSULATED. FAUCETS SHALL BE LEVER-OPERATED, PUSH-TYPE AND
MOTION SENSOR.
URINALS: URINALS SHALL BE STALL-TYPE OR WALL HUNG WITH THE RIM
AT A MAXIMUM OF 17" AFF AND A 30" X 48" CLEAR FLOOR SPACE.
GRAB BARS: GRAB BARS SHALL BE 33" TO 36" AFF THE GRAB BAR BEHIND
THE WATER CLOSET SHALL BE 36" LONG AND NO MORE THAN 6" OF OF
THE SIDE WALL. THE SIDE WALL GRAB BAR SHALL BE 42" LONG AND 12"
OFF THE BACK WALL.
MIRROR: MIRRORS SHALL BE MOUNTED SO THE BOTTOM OF THE
REFLECTING SURFACE IS NO MORE THAN 40" AFF.
PAPER TOWEL/DRYER: PAPER TOWEL/ DRYERS SHALL BE MOUNTED NO
HIGHER THAN 48" AFF.
SOAP DISPENSER: SOAP DISPENSERS SHALL BE MOUNTED NO HIGHER
THAN 48" AFF.
TOILET PAPER: TOILET PAPER DISPENSERS SHALL BE INSTALLED WITHIN 36"
MAX OF THE BACK WALL.
TYPICAL ADA INFO
TYPICAL MOUNTING HEIGHTS 1
1/2" = 1'-0"
TOILET STALL DIMENSIONS 2
1/2" = 1'-0"
SINK CLEAR SPACE
3
3/4" = 1'-0"
URINAL CLEAR SPACE
4
3/4" = 1'-0"
GRAB BAR DIMENSIONS 5
3" = 1'-0"
ACCESSIBLE ROUTES 6
1/2" = 1'-0"
VERTICAL CLEARANCES 7
1/2" = 1'-0"
SHOWER STALL DIMENSIONS 8
1/2" = 1'-0"
FLOOR TRANSITIONS 9
6" = 1'-0"
REACH RANGES 10
1/4" = 1'-0"
PERMIT SET 09.16.21
PROJECT NUMBER: 210082
THIS DRAWING AND THE IDEAS, DESIGNS
AND CONCEPTS CONTAINED HEREIN ARE
THE EXCLUSIVE INTELLECTUAL PROPERTY
OF CURRAN ARCHITECTURE, AND ARE NOT
TO BE USED OR REPRODUCED, WHOLE OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF CURRAN ARCHITECTURE.
COPYRIGHT 2020, CURRAN ARCHITECTUREC
PROJECT INFORMATION
CERTIFICATION
ISSUE DATES
F :: 317 . 288 . 0753
O :: 317 . 288 . 0681
INDIANAPOLIS, IN 46216
5719 LAWTON LOOP E. DR. #212
TENANT IMPROVEMENTS
1717 E. 116TH STREET,
CARMEL
1717 E. 116TH STREET, CARMEL,
INDIANA 46032
TYPICAL ACCESSIBILITY
DETAILS