HomeMy WebLinkAboutA101 Floor Plan5
A101
TOTAL TRAVEL DISTANCE TO EXIT: 79'-6"
4
GB1
TT1
GB2
GB1
TD1
M1
2
1 3
GB1
TT1
GB2
GB1
TD1
M1 SD1
2
1EQUAL
EQUAL1'-712"1'-712"7'-7 34"W1AW1AW1AW1A
SD1
W1A
1FIRST FLOOR PLAN
1/8"=1'-0"
A. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL
DIMENSIONS AND JOB CONDITIONS. ANY DEVIATION FROM
WHAT IS NOTED IN DRAWINGS SHALL BE BROUGHT TO THE
ATTENTION OF THE ARCHITECT IMMEDIATELY.
B. ALL DIMENSIONS SHOWN ARE FACE OF BRICK, MASONRY OR GYP.
BD., UNLESS OTHERWISE NOTED.
C. PROVIDE DEEP LEG DEFLECTION TRACK AT ALL METAL STUD
CONNECTIONS WITH STRUCTURE ABOVE, TYPICAL.
D. PROVIDE FIRE RATED WOOD BLOCKING IN METAL STUD WALLS
FOR ANY WALL SUPPORTED ITEMS.
E. PROVIDE APPROVED FIRE RATED STOPPING MATERIALS IN ANY
OPENINGS IN FIRE RATED ASSEMBLIES.
F. REFER TO DOOR AND WINDOW SCHEDULES FOR ALL MATERIALS,
FINISHES, AND HARDWARE INFORMATION.
G. REFER TO EXTERIOR ELEVATIONS FOR ALL BRICK, MASONRY, AND
OTHER EXPANSION JOINT LOCATIONS.
H. ALL MATERIALS LOCATED IN CEILING PLENUM SHALL BE RATED
FOR SUCH INSTALLATION OR PROTECTED TO PROVIDE
COMPLIANCE. THIS INCLUDES BUT IS NOT LIMITED TO
INSULATION (FHC 25/50) POWER AND LOW VOLTAGE WIRING,
TELECOMMUNICATIONS CABLING, PLUMBING SUPPLY AND DRAIN
LINES AND SUPPORTING BRACKETS AND/OR BLOCKING FOR
CEILING HUNG ITEMS.
I. PRIOR TO ORDERING ANY PRODUCTS, CONTRACTOR SHALL
SUBMIT SAMPLES TO THE ARCHITECT OF ALL FINISH MATERIALS
TO BE USED ON THE PROJECT. THE CONTRACTOR SHALL BEAR
SOLE RESPONSIBILITY FOR ANY MATERIALS ORDERED
INCORRECTLY WHEN THAT MATERIAL WAS NOT REVIEWED BY
THE ARCHITECT.
J. PROVIDE CONCRETE FILLED STEEL PIPE BOLLARDS AT ALL
REQUIRED UTILITY EQUIPMENT LOCATIONS SUCH AS GAS METERS,
ELECTRICAL TRANSFORMER PANELS, ETC., COORDINATE WITH
UTILITY COMPANY AND CONTRACTORS, WHEN APPLICABLE, FOR
NECESSARY LOCATIONS. REFER TO CIVIL DRAWINGS FOR
BOLLARD SPECIFICATIONS AND ADDITIONAL INFORMATION.
K. ALL DOORS, UNLESS OTHERWISE NOTED, TO HAVE HINGE SIDE
SET 4" FROM CORNER SHOWN TO OUTSIDE OF FRAME.
L. UNLESS SPECIFIED ELSEWHERE, ALL INTERIOR SLABS AND SLAB
INFILLS TO BE FF-50/FL-35 OVERALL AND FF-35/FL-25 LOCAL.
M. ALL EXIT DOORS TO HAVE TACTILE EXIT SIGNAGE PER 703.4 OF
THE ANSI 117.1 2009
GENERAL NOTES
1. ADA COMPLIANT TANK TYPE TOILET. SEE A002 FOR FIXTURE
HEIGHT AND ALL ASSOCIATED ACCESSORIES
2. ADA COMPLIANT WALL HUNG LAVATORY WITH SCALD GUARDS.
SEE A002 FOR FIXTURE HEIGHT AND ALL ASSOCIATED
ACCESSORIES.
3. (1) ADA COMPLIANT DRINKING FOUNTAIN, (1) NON-ADA
COMPLIANT DRINKING FOUNTAIN.
4. INSTALL FIXTURES, PARTITIONS, ETC IN SAME LOCATION AFTER
NEW FINISHES ARE INSTALLED.
KEYED NOTES
KEY PLAN
PERMIT SET 09.16.21
PROJECT NUMBER: 210082
THIS DRAWING AND THE IDEAS, DESIGNS
AND CONCEPTS CONTAINED HEREIN ARE
THE EXCLUSIVE INTELLECTUAL PROPERTY
OF CURRAN ARCHITECTURE, AND ARE NOT
TO BE USED OR REPRODUCED, WHOLE OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF CURRAN ARCHITECTURE.
COPYRIGHT 2020, CURRAN ARCHITECTUREC
PROJECT INFORMATION
CERTIFICATION
ISSUE DATES
F :: 317 . 288 . 0753
O :: 317 . 288 . 0681
INDIANAPOLIS, IN 46216
5719 LAWTON LOOP E. DR. #212
TENANT IMPROVEMENTS
1717 E. 116TH STREET,
CARMEL
1717 E. 116TH STREET, CARMEL,
INDIANA 46032
N
FLOOR PLAN
A101
TOILET ACCESSORY SCHEDULE
MARK SYMBOL MFR #DESCRIPTION
TT1 BOBRICK
B-2888 MULTI-ROLL TOILET TISSUE DISPENSER
GB1
BOBRICK
B-5806 X 36
B-5806 X 42
36" AND 42" GRAB BARS
GB2
BOBRICK
B-5806 X 18 18" VERTICAL GRAB BAR
GB3 BOBRICK
B-6861 GRAB BAR FOR SHOWER STALL
M1 BOBRICK
B-165 MIRROR 2'-0" X 4'-0"
TD1 BOBRICK
B-3944 TOWEL DISPENSER / WASTE RECEPTACLE
SD1 BOBRICK
B-2112 SOAP DISPENSER
ND1
BOBRICK
B-353
B-270
B-353: SANITARY NAPKIN DISPOSAL UNIT AT GWB LOCATIONS.
B-270: SURFACE, MOUNT SANITARY NAPKIN DISPOSAL UNIT AT
PARTITIONS
SS1 BOBRICK
B-5181 FOLDING SEAT FOR ADA SHOWER
SH1 NOT APPLICABLE SHOWER HEAD
TP1 GENERAL
PARTITION
TOILET PARTITION AND/OR URINAL SCREEN POWDER COATED URINAL
SCREEN BOTTOM 12" FROM FLOOR AND TOP 60" MAX FROM FLOOR
N
2 SECOND FLOOR PLAN
1/8"=1'-0"N5 ENLARGED RESTROOM PLAN
1/2"=1'-0"
N
LIFE SAFETY SHOWN FOR REFERENCE.
NO CHANGE OF USE
NO CHANGE OF OCCUPANCY
ONLY WORK TO BE DONE IS RENOVATION OF 1ST FLOOR
RESTROOMS TO MEET ADA REQUIREMENTS AND INTERIOR FINISH
UPDATES THROUGHOUT COMMON SPACE.
3SUPPLY ISOMETRIC
NOT TO SCALE
TIE INTO 3" VENT THRU ROOF, VERIFY
LOCATION IN FIELD. AT
CONTRACTOR'S OPTION PROVIDE NEW
3" VTR.
4SANITARY ISOMETRIC
NOT TO SCALE
CONNECT TO
EXIST.
SANITARY
LAV
NEW
TOILET
NEW
CW
TOILET
NEW
CW
HW
LAV
NEW
TOILET
NEW
LAV
NEW
DRINKING
NEW
FOUNTAIN
DRINKING
NEW
FOUNTAIN
TOILET
NEWCW
CW
HW
LAV
NEW
CWCW DRINKING
NEW
FOUNTAIN
DRINKING
NEW
FOUNTAIN
HW
CW
CONNECT TO
EXIST.
SUPPLY
CONNECT TOEXIST.
SUPPLY
01/19/22