HomeMy WebLinkAboutA102 Reflected Ceiling Plan2 1 3 3 33 3 3 3 3 3 33 3 4 3 3 3 1. ADJUST CEILING GRID AND TILES, THIS LOCATION (WHERE VESTIBULE WAS REMOVED) TO PROVIDE SEAMLESS CEILING. 2. NEW GYP. BD. BULKHEAD AT 7'-6" AFF. 3. DAMAGED/STAINED CEILING TILES TO BE REPLACED AS REQUIRED. CONFIRM WITH OWNER FOR FULL SCOPE. 4. NEW ACOUSTICAL CEILING TILE TO MATCH HEIGHT OF EXISTING CEILING. KEYED NOTES KEY PLAN PERMIT SET 09.16.21 PROJECT NUMBER: 210082 THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CURRAN ARCHITECTURE, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CURRAN ARCHITECTURE. COPYRIGHT 2020, CURRAN ARCHITECTUREC PROJECT INFORMATION CERTIFICATION ISSUE DATES F :: 317 . 288 . 0753 O :: 317 . 288 . 0681 INDIANAPOLIS, IN 46216 5719 LAWTON LOOP E. DR. #212 TENANT IMPROVEMENTS 1717 E. 116TH STREET, CARMEL 1717 E. 116TH STREET, CARMEL, INDIANA 46032 N REFLECTED CEILING PLAN A110 CEILING LEGEND (NOT ALL MAY APPLY) JUNCTION BOX - COORDINATE WITH TENANT ON WIRING REQUIREMENTS EXISTING LIGHT FIXTURE TO REMAIN 2x4 LED LAY IN FIXTURE. METALUX CRUZE CZ24 30.1 WATTS DENOTES LIGHT FIXTURE WIRED TO 24 HOUR CIRCUIT (NIGHT LIGHT) 2x2 LED LAY IN FIXTURE. METALUX CRUZE CZ22 21.9 WATTS 4'-0" INDUSTRIAL STRIP LED LIGHT W/ ROUND LENS. METALUX SNLED-LD5-LW 21 WATTS. PENDANT HUNG LIGHT FIXTURE TO BE SELECTED WALL SCONCE TO BE SELECTED 4" LED ROUND CAN LIGHT. HALO PRSR-35 WALL MOUNTED EMERGENCY LIGHT WITH 90 MINUTE BACKUP. EQUAL TO NAVILITE N1WH. (2) 5.4 WALL LAMPS, 11 WATTS TOTAL. WALL OR CEILING MOUNTED EXIT SIGN WITH 90 MINUTE BACKUP. EQUAL TO NAVILITE NXP3GWH. 2.7 TOTAL WATT LED LAMP. WALL OR CEILING MOUNTED EXIT SIGN-LIGHT COMBO WITH 90 MINUTE BACKUP. EQUAL TO NAVILITE NXPC3GWH. 4.2 TOTAL WATTS STANDBY POWER COMBINATION LIGHT / FAN DUCTED TO EXTERIOR. EQUAL TO BROAN / NUTONE AERN110L FAN / LIGHT COMBO WITH WITH LED LIGHT 11 WATTS ACOUSTICAL TILE CEILING / GRID. REFER TO FINISH SCHEDULE FOR TYPE AND HEIGHT. GYPSUM BOARD BULKHEAD OR CEILING. HEIGHT AS NOTED ON SCHEDULE OR KEYNOTES. DIFFUSER - SUPPLY DIFFUSER - RETURN WALL MOUNTED LIGHT SWITCH 3 = 3WAY SWITCH 4 = 4 WAY SWITCH D = ELECTRONIC DIMMER OS = OCCUPANCY SENSOR NOTE: SUPPLY RETURN AND SPRINKLER LOCATIONS SHOWN ON PLANS FOR REFERENCE ONLY. CONTRACTOR IS TO PROVIDE LAYOUT, ENGINEERING AND STATE SUBMITTAL UNDER DESIGN-BUILD CONTRACT. 1FIRST FLOOR REFLECTED CEILING PLAN 1/8"=1'-0"N 2SECOND FLOOR REFLECTED CEILING PLN 1/8"=1'-0"N 01/19/22