HomeMy WebLinkAboutA-01 Architectural Site Plan(2) 2x12 HDR
(2) 2x12 HDR
SEE FLOOR PLANS AND WALL SECTION
FOR TOP PLATE HEIGHTS
SEE FLOOR PLANS FOR
HEADER HEIGHTS
KING AND JACK STUDS
DOOR
WDW
1'-0"
FLASHING
SLOPE GRADE AWAYFROM FOUNDATION
1x TRIM - MATCH EXISTING
1/2" EXTERIOR SHEATHING
AIR-INFILTRATION BARRIER
CEMENTITIOUS HORIZONTALLAP SIDING.
BATT INSULATION
AT BAND BOARD
14" "I" JOISTS AT 16" O.C.
3/4" T&G PLYWOOD SUBFLOOR
2x4 PLATE
FINISH FLOORING
BASEBOARD
5/8" GYPSUMBOARD CEILING
DOUBLE TOP PLATE
2x4'S AT 16" O.C.
3 1/2" BATT INSULATION1/2" GYPSUM BOARD
5/8" GYPSUM
BOARD CEILING
DOUBLE TOP PLATE
1/2" ROOF SHEATHING
30# ROOFING FELT
FIBERGLASS SHINGLES
ICE AND WATER MEMBRANE
METAL DRIP EDGE
GUTTER
2x6 SUB FASCIA
1x8 FASCIA
3/8" VENTILATED SOFFIT
1x4 TRIM
2x8 RAFTERS AT 16" O.C.
12
12
1/2" EXTERIOR SHEATHING
AIR-INFILTRATION BARRIER
CEMENTITIOUS HIORIZONTALLAP SIDING
EXTERIOR SIDING
AND TRIM COLORSTO MATCH EXISTING FINISH FLOORING
BASEBOARD
BATT INSULATIONAT BAND BOARD
INSULATION BAFFLE
R-38 BATT INSULATION
MATCH EXISTING SLOPE
2x6 CEILING JOISTS
AT 16" O.C.
EXISTING FOUNDATION
AND FLOOR STRUCTURE
TO REMAIN
EXISTING
FIRST FLOOR WALLS
TO REMAIN
ALL FINISH MATERIALSDETAILS AND COLORS
TO BEST MATCH EXISTING
AS CLOSELY AS POSSIBLE 10'-1 1/8"9'-1 1/8"8" MINFLASHING
SLOPE GRADE AWAY
FROM FOUNDATION
1x TRIM - MATCH EXISTING
1/2" EXTERIOR SHEATHING
AIR-INFILTRATION BARRIER
CEMENTITIOUS HORIZONTALLAP SIDING.
BATT INSULATIONAT BAND BOARD
14" "I" JOISTS AT 16" O.C.
3/4" T&G PLYWOOD SUBFLOOR
2x4 PLATE
FINISH FLOORING
BASEBOARD
5/8" GYPSUM
BOARD CEILING
DOUBLE TOP PLATE
2x4'S AT 16" O.C.
3 1/2" BATT INSULATION1/2" GYPSUM BOARD
5/8" GYPSUMBOARD CEILING
DOUBLE TOP PLATE
1/2" ROOF SHEATHING30# ROOFING FELTFIBERGLASS SHINGLESICE AND WATER MEMBRANEMETAL DRIP EDGEGUTTER
2x6 SUB FASCIA
1x8 FASCIA
3/8" VENTILATED SOFFIT
1x4 TRIM
2x8 RAFTERS AT 16" O.C.1212
1/2" EXTERIOR SHEATHING
AIR-INFILTRATION BARRIERCEMENTITIOUS HIORIZONTALLAP SIDING
EXTERIOR SIDING
AND TRIM COLORSTO MATCH EXISTING FINISH FLOORING
BASEBOARD
BATT INSULATIONAT BAND BOARD
INSULATION BAFFLER-38 BATT INSULATION MATCH EXISTING SLOPE2x6 CEILING JOISTSAT 16" O.C.
EXISTING FOUNDATION
AND FLOOR STRUCTURETO REMAIN
EXISTING
FIRST FLOOR WALLSTO REMAIN
ALL FINISH MATERIALSDETAILS AND COLORS
TO BEST MATCH EXISTINGAS CLOSELY AS POSSIBLE 10'-1 1/8"6'-1 1/8"FLASHING
SLOPE GRADE AWAY
FROM FOUNDATION
1x TRIM - MATCH EXISTING
1/2" EXTERIOR SHEATHINGAIR-INFILTRATION BARRIERCEMENTITIOUS HORIZONTAL
LAP SIDING.
BATT INSULATION
AT BAND BOARD
14" "I" JOISTS AT 16" O.C.
3/4" T&G PLYWOOD SUBFLOOR
2x4 PLATE
FINISH FLOORING
BASEBOARD
5/8" GYPSUM
BOARD CEILING
DOUBLE TOP PLATE
2x4'S AT 16" O.C.3 1/2" BATT INSULATION
1/2" GYPSUM BOARD
5/8" GYPSUM
BOARD CEILING
DOUBLE TOP PLATE
1/2" ROOF SHEATHING
30# ROOFING FELT
FIBERGLASS SHINGLES
ICE AND WATER MEMBRANE
METAL DRIP EDGE
GUTTER
2x6 SUB FASCIA
1x8 FASCIA
3/8" VENTILATED SOFFIT
1x4 TRIM
2x8 RAFTERS AT 16" O.C.
12
12
1/2" EXTERIOR SHEATHINGAIR-INFILTRATION BARRIER
CEMENTITIOUS HIORIZONTAL
LAP SIDING
EXTERIOR SIDINGAND TRIM COLORS
TO MATCH EXISTING FINISH FLOORING
BASEBOARD
BATT INSULATION
AT BAND BOARD
INSULATION BAFFLE
R-38 BATT INSULATION
MATCH EXISTING SLOPE
2x6 CEILING JOISTSAT 16" O.C.
EXISTING FOUNDATIONAND FLOOR STRUCTURE
TO REMAIN
EXISTINGFIRST FLOOR WALLS
TO REMAIN
ALL FINISH MATERIALS
DETAILS AND COLORSTO BEST MATCH EXISTING
AS CLOSELY AS POSSIBLE 10'-1 1/8"N
50'-6"31'-0"4 0 '-2 1 /2 "128'-10"42'-0"40'-0" SETBACKPALACE CT
57.5'R R/W
N 75°42'00" W 166.87'S 00°11'58" W 251.49'N 26°09'27" E 242.38'S 49°40'00" E 112.94'10'-0" MINIMUM SIDE YARD SETBACK7'-6" D
R
AIN
A
G
E & UTILITY EASE
M
E
NT
30'-0" DRAINAGE & UTILITY EASEMENT15'-0" DRAINAGE & UTILITY EASEMENT20'-0" D & U ECONCRETE
DRIVEWAYR=5
7.
5
0'
L
=7
8.
4
2'
LOCATION OF
ROOM ADDITION
OVER EXISTING
SUNROOM
886
886
887
888
888
887
886
887
887
886
886
886
889
SLOPE GRADE TO
DRAIN AWAY FROM
STRUCTURE
20'-0" MINIM
U
M REA
R YA
R
D S
ETBA
C
K
Description
Architectural
Site Plan
Sheet Number
A-01
C2021 WGGTHIS PLAN IS PROPERTY OFWILLIAM GORDON GROUP.ANY UNAUTHORIZED USE ORREPRODUCTION OF THIS PLAN, INWHOLE OR IN PART ISPROHIBITED. WGG WILL USE ALLLEGAL MEANS AVAILABLE TOPURSUE THE UNAUTHORIZED USEOF THIS PLAN OR ANY DESIGNELEMENTS CONTAINED THEREIN.Boris Residence - Remodel and AdditionKings Mill - Section 1 - Lot 72972 Palace Court, Carmel, Indiana 46032Date
12.28.21
Architectural Site Plan
SCALE: 1" = 40'-0"
Typical Door and Window Framing
SCALE: 1/4" = 1'-0"
Area Location Map
NO SCALE
Typical Wall Section
SCALE: 1/2" = 1'-0"
SQUARE FOOTAGE TABLE
SFGARAGE886
SFFRONT PORCH 53
SF
SF
SECOND FLOOR
FIRST FLOOR 2,974
1,283
SFBASEMENT (FINISHED)1,797
SFLOT31,840
REQUIRED
ZONING: S1
128 FTMINIMUM DEPTH OF REAR YARD 20 FT
42 FT
18%
MINIMUM WIDTH OF SIDEYARD
MAXIMUM LOT COVERAGE 35%
10 FT
92 FTMINIMUM AGGREGATE SIDEYARD 30 FT
PROPOSED
REMODELED AREA - FIRST FLOOR KITCHEN
REMODELED AREA - SECOND FLOOR ADDITION
SF886
SF53
SF
SF2,974
1,608
SF1,797
SF330
SF325
EXISTING PROPOSED
REMODELED AREA - BASEMENT 0 SF
GENERAL NOTES:
WRITTEN DIMENSIONS AND SPECIFIC NOTES SHALLTAKE PRECEDENCE OVER SCALED DIMENSIONS AND
GENERAL NOTES. THE ENGINEER/DESIGNER SHALL BE
CONSULTED FOR CLARIFICATION IF SITE CONDITIONSARE ENCOUNTERED THAT ARE DIFFERENT THAN
SHOWN, IF DISCREPANCIES ARE FOUND IN THE PLANS
OR NOTES, OR IF A QUESTION ARISES OVER THE INTENTOF THE PLANS OR NOTES. CONTRACTOR SHALL VERIFY
AND IS RESPONSIBLE FOR ALL DIMENSIONS (INCLUDING
ROUGH OPENINGS).
ALL CONTRACTORS ARE TO CLEAN UP THE JOBSITE PER
THEIR WORK.
THE BUILDER SHALL VERIFY THAT SITE CONDITIONS ARE
CONSISTENT WITH THESE PLANS BEFORE STARTING
WORK.
WORK NOT SPECIFICALLY DETAILED SHALL BE
CONSTRUCTED TO THE SAME QUALITY AS SIMILARWORK THAT IS DETAILED.
ALL WORK SHALL BE DONE IN ACCORDANCE WITHINTERNATIONAL BUILDING CODES AND LOCAL CODES.