Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
GN010.1 Engr stamp
16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). December 23,2021 Liu, Xuegang Pages or sheets covered by this seal: I49399723 thru I49399755 My license renewal date for the state of Indiana is July 31, 2022. B21100270 LOT# 67 SUNRISE IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use,the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss GE01 Truss Type Common Supported Gable Qty 1 Ply 1 LOT# 67 SUNRISE Job Reference (optional) I49399723 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:18 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-eM1R5L4GyGTKpcTFuKJGtbvEXVwmN_HdDN2cYny6QqZ Scale = 1:50.5 Sheet FrontFull Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 25 24 23 22 21 20 19 18 17 16 15 14 26 27 4x6 3x6 22-0-0 22-0-0 -0-10-8 0-10-8 11-0-0 11-0-0 22-0-0 11-0-0 22-10-8 0-10-8 1-1-88-5-81-1-88.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.11 0.05 0.33 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 12 12 14 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 306 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 22-0-0. (lb) - Max Horz 25=-146(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 25, 14, 20, 21, 23, 24, 18, 17, 16, 15 Max Grav All reactions 250 lb or less at joint(s) 25, 14, 19, 20, 21, 23, 24, 18, 17, 16, 15 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -0-10-8 to 2-1-8, Exterior(2N) 2-1-8 to 11-0-0, Corner(3R) 11-0-0 to 14-0-0, Exterior(2N) 14-0-0 to 22-10-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 2-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 25, 14, 20, 21, 23, 24, 18, 17, 16, 15. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. December 23,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss GE02 Truss Type Common Structural Gable Qty 1 Ply 1 LOT# 67 SUNRISE Job Reference (optional) I49399724 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:20 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-ak9CW06WUtj23wcd0kMkz0_NEJQqrowwghXjdfy6QqX Scale = 1:85.4 Sheet Front Full Sheathing 1 Ply 7/16OSB8 12 3 4 5 6 7 8 9 20 19 18 17 15 14 13 12 11 10 54 55 56 57 58 59 16 60 3x6 7x16 MT18HS 6x16 3x6 4x8 3x4 4x6 4x6 4x6 12x12 3x4 5x8 3x8 11-6-3 11-6-3 22-0-0 10-5-13 22-9-13 0-9-13 34-4-0 11-6-3 -0-10-8 0-10-8 8-8-4 8-8-4 17-2-0 8-5-12 25-7-12 8-5-12 34-4-0 8-8-4 35-2-8 0-10-8 1-1-812-6-131-1-88.00 12 Plate Offsets (X,Y)-- [2:Edge,0-2-0], [5:0-8-0,0-10-0], [8:0-4-3,Edge], [18:0-4-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.92 0.78 0.77 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.41 -0.71 0.02 (loc) 19-20 19-20 10 l/defl >632 >366 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 708 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 18-20: 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 *Except* 6-15,4-19: 2x3 SPF No.2, 2-20,8-10: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 *Except* 5-21: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-15, 4-20 REACTIONS.All bearings 12-7-8 except (jt=length) 20=0-3-8, 16=0-3-8. (lb) - Max Horz 20=-220(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 20, 10 except 15=-172(LC 12) Max Grav All reactions 250 lb or less at joint(s) 14, 13, 12, 11 except 15=993(LC 1), 20=1093(LC 17), 10=440(LC 24), 16=790(LC 16) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-751/145, 4-5=-1024/158, 6-8=-448/212, 2-20=-634/127, 8-10=-470/164 BOT CHORD 19-20=0/1009, 16-19=0/407, 15-16=0/407 WEBS 5-15=-925/0, 6-15=-488/176, 5-19=-16/1015, 4-19=-448/173, 4-20=-550/0 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=34ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -0-10-8 to 2-6-11, Interior(1) 2-6-11 to 17-2-0, Exterior(2R) 17-2-0 to 20-7-3, Interior(1) 20-7-3 to 35-2-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are MT20 plates unless otherwise indicated. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 10 except (jt=lb) 15=172. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. December 23,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss GE03 Truss Type Roof Special Structural Gable Qty 1 Ply 1 LOT# 67 SUNRISE Job Reference (optional) I49399725 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:22 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-W7Gyxi7n0V_mIDm079OC2R3kU67IJn0D8_0phYy6QqV Scale = 1:83.2 Sheet Back Full Sheathing1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 20 19 18 16 15 14 13 12 11 38 39 40 41 17 3x6 4x6 6x8 5x6 6x6 3x6 3x8 3x4 3x4 3x12 3x6 6x8 3x4 3x4 3x4 11-6-0 11-6-0 14-8-0 3-2-0 20-4-15 5-8-15 21-11-11 1-6-12 24-5-0 2-5-5 -0-10-80-10-8 5-10-45-10-4 11-6-05-7-12 20-4-158-10-15 21-11-111-6-12 23-6-11 1-7-024-5-0 0-10-5 25-3-8 0-10-8 1-5-04-0-12-4-01-2-1512-11-00-10-1212.00 12 12.84 12 8.25 12 4.86 12 Plate Offsets (X,Y)-- [12:0-3-15,0-1-8], [21:0-1-15,0-1-0], [24:0-1-15,0-1-0], [34:0-1-0,0-1-8], [36:0-1-0,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.88 0.66 0.35 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.51 -0.83 0.01 (loc) 18-20 18-20 11 l/defl >335 >209 n/a L/d 240 180 n/a PLATES MT20 Weight: 504 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 5-6: 2x4 SP 2400F 2.0E BOT CHORD 2x4 SP 2400F 2.0E *Except* 19-20: 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 5-18: 2x4 SPF No.2, 2-20,9-11: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-18, 4-20 REACTIONS.All bearings 10-0-8 except (jt=length) 20=0-3-8, 17=0-3-8. (lb) - Max Horz 20=-242(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 13, 11 except 17=-366(LC 16) Max Grav All reactions 250 lb or less at joint(s) 12, 11, 15, 14 except 13=782(LC 18), 20=1007(LC 17), 16=271(LC 16) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-543/151, 4-5=-743/152, 5-6=-829/113, 2-20=-527/162 BOT CHORD 18-20=-1/677 WEBS 5-18=-21/549, 6-18=0/389, 6-13=-835/153, 4-20=-490/0 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 11-6-0, Exterior(2R) 11-6-0 to 14-6-0, Interior(1) 14-6-0 to 23-6-11, Exterior(2E) 23-6-11 to 25-3-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 11 except (jt=lb) 17=366. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. December 23,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss GE04 Truss Type Piggyback Base Supported Gable Qty 1 Ply 1 LOT# 67 SUNRISE Job Reference (optional) I49399726 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:24 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-TWOiMO91Y6EUYXwPFaQg7s9FRwydnjuWbIVwmQy6QqT Scale = 1:78.3 Sheet Back Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 3x4 3x6 3x6 3x6 3x6 5x6 5x6 36-10-8 36-10-8 16-3-12 16-3-12 20-10-4 4-6-8 36-10-8 16-0-4 1-1-812-0-01-3-1312-0-08.00 12 Plate Offsets (X,Y)-- [3:0-1-10,Edge], [10:0-3-0,0-0-2], [13:0-4-4,0-2-4], [31:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.14 0.09 0.19 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.01 (loc) - - 23 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 747 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 *Except* 13-31,12-32,11-33,9-35,14-30: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 10-13. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 13-31, 12-32, 11-33, 9-35, 8-36, 14-30, 15-29 REACTIONS.All bearings 36-10-8. (lb) - Max Horz 42=203(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 42, 23, 32, 36, 37, 38, 39, 40, 41, 30, 29, 28, 27, 26, 25, 24 Max Grav All reactions 250 lb or less at joint(s) 42, 23, 31, 32, 33, 35, 36, 37, 38, 39, 40, 30, 29, 28, 27, 26, 25, 24 except 41=269(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 8-9=-181/280, 9-10=-189/293, 10-11=-167/268, 11-12=-167/268, 12-13=-167/268, 13-14=-196/306, 14-15=-171/265 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=37ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) 0-1-4 to 3-9-8, Exterior(2N) 3-9-8 to 16-3-12, Corner(3R) 16-3-12 to 20-0-0, Exterior(2N) 20-0-0 to 20-10-4, Corner(3R) 20-10-4 to 24-6-8, Exterior(2N) 24-6-8 to 36-9-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 2-0-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 42, 23, 32, 36, 37, 38, 39, 40, 41, 30, 29, 28, 27, 26, 25, 24. 12) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. December 23,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss GE05 Truss Type Piggyback Base Supported Gable Qty 1 Ply 1 LOT# 67 SUNRISE Job Reference (optional) I49399727 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:26 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-PuWTn4AH3jUCnr4nM?T8CHEbvjeAFdOo2c_1rJy6QqR Scale = 1:79.1 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 3x6 3x6 3x6 3x6 5x6 5x6 37-2-0 37-2-0 16-3-12 16-3-12 20-10-4 4-6-8 37-2-0 16-3-12 38-0-8 0-10-8 1-1-812-0-01-1-812-0-08.00 12 Plate Offsets (X,Y)-- [3:0-1-10,Edge], [10:0-3-0,0-0-2], [13:0-4-4,0-2-4], [33:0-2-4,0-0-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.14 0.08 0.19 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.01 (loc) 23 23 24 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 750 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 22-24: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 *Except* 13-33,12-34,11-35,9-37,14-31: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 10-13. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 13-33, 12-34, 11-35, 9-37, 8-38, 14-31, 15-30 REACTIONS.All bearings 37-2-0. (lb) - Max Horz 44=-209(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 44, 24, 34, 38, 39, 40, 41, 42, 43, 31, 30, 29, 28, 27, 26, 25 Max Grav All reactions 250 lb or less at joint(s) 44, 24, 33, 34, 35, 37, 38, 39, 40, 41, 42, 31, 30, 29, 28, 27, 26, 25 except 43=260(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 8-9=-177/276, 9-10=-186/289, 10-11=-165/265, 11-12=-165/265, 12-13=-165/265, 13-14=-193/302, 14-15=-167/260 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=37ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) 0-1-4 to 3-9-14, Exterior(2N) 3-9-14 to 16-3-12, Corner(3R) 16-3-12 to 20-0-6, Exterior(2N) 20-0-6 to 20-10-4, Corner(3R) 20-10-4 to 24-10-4, Exterior(2N) 24-10-4 to 38-0-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 2-0-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 44, 24, 34, 38, 39, 40, 41, 42, 43, 31, 30, 29, 28, 27, 26, 25. 12) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.December 23,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss GE07 Truss Type Common Supported Gable Qty 1 Ply 1 LOT# 67 SUNRISE Job Reference (optional) I49399728 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:28 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-LHeDClCYbLkv08EAUQVcHiJwBXJmjXJ5WwT8vBy6QqP Scale = 1:52.8 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 21 22 3x4 4x6 3x4 14-8-0 14-8-0 -0-10-8 0-10-8 7-4-0 7-4-0 14-8-0 7-4-0 15-6-8 0-10-8 1-5-08-9-01-5-012.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.16 0.08 0.23 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 11 11 12 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 222 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 6-16 REACTIONS.All bearings 14-8-0. (lb) - Max Horz 20=-175(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 12, 17, 18, 19, 15, 14, 13 except 20=-102(LC 10) Max Grav All reactions 250 lb or less at joint(s) 20, 12, 17, 18, 19, 15, 14, 13 except 16=276(LC 12) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 5-6=-141/303, 6-7=-141/303 WEBS 6-16=-360/112 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Corner(3E) -0-10-8 to 2-1-8, Exterior(2N) 2-1-8 to 7-4-0, Corner(3R) 7-4-0 to 10-4-0, Exterior(2N) 10-4-0 to 15-6-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 2-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 17, 18, 19, 15, 14, 13 except (jt=lb) 20=102. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. December 23,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss PB01 Truss Type Piggyback Qty 17 Ply 1 LOT# 67 SUNRISE Job Reference (optional) I49399729 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:29 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-pTBbP5DAMesmeIpM170rqvs7zxgtS1zFlaDhRey6QqO Scale = 1:9.6 1 2 3 4 5 6 4x6 2x4 2x4 2x4 4-6-8 4-6-8 2-3-4 2-3-4 4-6-8 2-3-4 0-4-71-4-110-1-80-4-70-1-88.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.03 0.02 0.01 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 0.00 (loc) 4 4 4 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-6-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=3-0-10, 4=3-0-10, 6=3-0-10 Max Horz 2=-20(LC 10) Max Uplift 2=-18(LC 12), 4=-18(LC 12) Max Grav 2=97(LC 1), 4=97(LC 1), 6=102(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. December 23,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss PBE01 Truss Type Piggyback Qty 2 Ply 1 LOT# 67 SUNRISE Job Reference (optional) I49399730 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:30 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-Hgl_cRDo7y_dGSNYbrX4M7OIjL06BUCOzEyF_4y6QqN Scale = 1:9.6 Sheet Back Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 4x6 2x4 2x4 2x4 4-6-8 4-6-8 2-3-4 2-3-4 4-6-8 2-3-4 0-4-71-4-110-1-80-4-70-1-88.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.03 0.02 0.01 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 0.00 (loc) 4 4 4 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-6-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=3-0-10, 4=3-0-10, 6=3-0-10 Max Horz 2=-20(LC 10) Max Uplift 2=-18(LC 12), 4=-18(LC 12) Max Grav 2=97(LC 1), 4=97(LC 1), 6=102(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. December 23,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss T01 Truss Type Common Qty 4 Ply 1 LOT# 67 SUNRISE Job Reference (optional) I49399731 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:31 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-msJMqnEQuG6Utcyl9Y2JvKxGxk9lwo0YCuioWWy6QqM Scale = 1:78.2 12 3 4 5 6 7 8 910 16 15 14 13 12 11 17 18 19 20 21 3x6 4x8 3x6 5x12 4x6 4x6 3x6 3x4 2x4 3x8 3x4 3x4 2x4 8x8 3x6 8-8-4 8-8-4 17-2-0 8-5-12 27-10-12 10-8-12 34-4-0 6-5-4 -0-10-8 0-10-8 8-8-4 8-8-4 17-2-0 8-5-12 25-7-12 8-5-12 34-4-0 8-8-4 35-2-8 0-10-8 1-1-812-6-131-1-88.00 12 Plate Offsets (X,Y)-- [9:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.89 0.89 0.62 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.42 -0.69 0.04 (loc) 12-14 12-14 11 l/defl >791 >486 n/a L/d 240 180 n/a PLATES MT20 Weight: 159 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 4-16,7-12,9-12: 2x3 SPF No.2, 9-11: 2x4 SPF-S Stud SLIDER Left 2x8 SP 2400F 2.0E 5-5-2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 9-0-15 oc bracing. WEBS 1 Row at midpt 4-14, 7-12 REACTIONS. (size)2=0-3-8, 12=0-3-8, 11=0-3-8 Max Horz 2=211(LC 11) Max Uplift 2=-15(LC 12), 11=-88(LC 12) Max Grav 2=1282(LC 17), 12=1709(LC 18), 11=288(LC 24) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1567/62, 4-6=-950/146, 6-7=-963/142, 7-9=-122/255, 9-11=-251/110 BOT CHORD 2-16=0/1317, 14-16=0/1317, 12-14=-7/375, 11-12=-85/284 WEBS 4-16=0/395, 4-14=-712/94, 6-14=-40/509, 7-14=0/508, 7-12=-1328/17, 9-12=-397/88 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=34ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -0-10-8 to 2-6-11, Interior(1) 2-6-11 to 17-2-0, Exterior(2R) 17-2-0 to 20-7-3, Interior(1) 20-7-3 to 35-2-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 11. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. December 23,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss T02 Truss Type Common Qty 6 Ply 1 LOT# 67 SUNRISE Job Reference (optional) I49399732 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:32 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-E2tk17F2fZELVmXxjGZYSYUSe8XnfFxhRYRL2zy6QqL Scale = 1:75.0 12 3 4 5 6 7 8 9 10 11 15 14 13 12 16 17 18 19 3x6 5x6 3x6 5x12 5x6 5x6 4x6 4x6 2x4 3x4 2x4 5x12 5x6 5x6 4x6 11-3-14 11-3-14 22-5-4 11-1-6 34-4-0 11-10-12 -0-10-8 0-10-8 8-8-4 8-8-4 17-2-0 8-5-12 25-7-12 8-5-12 34-4-0 8-8-4 35-2-8 0-10-8 1-1-812-6-131-1-88.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.83 0.71 0.64 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.44 -0.70 0.03 (loc) 12-15 10-12 10 l/defl >605 >204 n/a L/d 240 180 n/a PLATES MT20 Weight: 164 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E *Except* 13-14: 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 4-15,8-12: 2x3 SPF No.2 SLIDER Left 2x8 SP 2400F 2.0E 5-5-4, Right 2x8 SP 2400F 2.0E 5-5-4 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-12 REACTIONS. (size)2=0-3-8, 12=0-3-8, 10=0-3-8 Max Horz 2=-197(LC 10) Max Uplift 2=-40(LC 12), 10=-81(LC 12) Max Grav 2=1119(LC 17), 12=1381(LC 17), 10=712(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1259/114, 4-6=-1116/202, 6-8=-434/253, 8-10=-650/177 BOT CHORD 2-15=-5/1069, 12-15=0/492, 10-12=-48/439 WEBS 4-15=-444/168, 6-15=-19/962, 6-12=-647/0, 8-12=-479/160 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=34ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -0-10-8 to 2-6-11, Interior(1) 2-6-11 to 17-2-0, Exterior(2R) 17-2-0 to 20-7-3, Interior(1) 20-7-3 to 35-2-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 10. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. December 23,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss T03 Truss Type Common Qty 7 Ply 1 LOT# 67 SUNRISE Job Reference (optional) I49399733 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:33 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-iER6FTGgQtMC7w67Gz5n_l0eNYs3Oj6qgCBvaPy6QqK Scale = 1:74.0 12 3 4 5 6 7 8 9 10 11 15 14 13 12 16 17 18 19 3x6 4x8 3x6 5x12 4x6 4x6 4x6 4x6 2x4 4x6 2x4 5x12 4x6 4x6 4x8 11-6-3 11-6-3 22-9-13 11-3-11 34-4-0 11-6-3 -0-10-8 0-10-8 8-8-4 8-8-4 17-2-0 8-5-12 25-7-12 8-5-12 34-4-0 8-8-4 35-2-8 0-10-8 1-1-812-6-131-1-88.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.70 0.77 0.51 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.55 -0.73 0.06 (loc) 12-15 12-15 10 l/defl >755 >567 n/a L/d 240 180 n/a PLATES MT20 Weight: 164 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF 2100F 1.8E *Except* 13-14: 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 8-12,4-15: 2x3 SPF No.2 SLIDER Left 2x8 SP 2400F 2.0E 5-5-4, Right 2x8 SP 2400F 2.0E 5-5-4 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 10=0-3-8 Max Horz 2=-197(LC 10) Max Grav 2=1598(LC 17), 10=1598(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-2043/49, 4-6=-1870/134, 6-8=-1870/135, 8-10=-2043/49 BOT CHORD 2-15=0/1686, 12-15=0/1163, 10-12=0/1555 WEBS 6-12=-17/898, 8-12=-403/172, 6-15=-17/899, 4-15=-403/172 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=34ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -0-10-8 to 2-6-11, Interior(1) 2-6-11 to 17-2-0, Exterior(2R) 17-2-0 to 20-7-3, Interior(1) 20-7-3 to 35-2-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. December 23,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss T04 Truss Type Roof Special Qty 1 Ply 1 LOT# 67 SUNRISE Job Reference (optional) I49399734 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:34 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-AR?USpGIBBU3k3hKqhc0XzZsRyGx7A3_uswS7ry6QqJ Scale = 1:86.6 1 2 3 4 5 6 7 8 9 10 17 16 15 14 13 12 11 18 19 20 21 3x6 7x16 MT18HS 6x8 5x6 6x6 2x4 3x6 3x6 3x4 3x8 3x4 3x12 5x8 2x4 3x4 5-10-4 5-10-4 14-6-4 8-8-0 20-4-15 5-10-11 21-11-11 1-6-12 24-5-0 2-5-5 -0-10-80-10-8 5-10-45-10-4 11-6-05-7-12 20-4-158-10-15 21-11-111-6-12 23-6-11 1-7-024-5-0 0-10-5 25-3-8 0-10-8 1-5-04-0-12-4-01-2-1512-11-00-10-1212.00 12 12.84 12 8.25 12 4.86 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [12:0-3-15,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.56 0.54 0.53 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.17 -0.28 0.01 (loc) 14-16 14-16 11 l/defl >999 >627 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 127 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 5-6: 2x4 SP 2400F 2.0E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 4-14,5-14: 2x4 SPF No.2, 2-17,9-11: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-14, 5-14 REACTIONS. (size)17=0-3-8, 14=0-3-8, 11=0-3-8 Max Horz 17=-242(LC 10) Max Uplift 17=-1(LC 12), 14=-9(LC 12) Max Grav 17=644(LC 18), 14=1218(LC 17), 11=417(LC 24) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-593/56, 5-6=-108/299, 6-7=-309/0, 7-8=-355/0, 8-9=-406/0, 2-17=-579/70, 9-11=-386/41 BOT CHORD 16-17=-195/289, 14-16=-27/458, 13-14=0/275, 12-13=0/272 WEBS 4-16=0/351, 4-14=-486/117, 5-14=-483/4, 6-14=-464/171, 2-16=0/299, 9-12=0/295 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) -0-10-8 to 2-1-8, Interior(1) 2-1-8 to 11-6-0, Exterior(2R) 11-6-0 to 14-6-0, Interior(1) 14-6-0 to 23-6-11, Exterior(2E) 23-6-11 to 25-3-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 17, 14. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. December 23,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss T05 Truss Type Piggyback Base Qty 7 Ply 1 LOT# 67 SUNRISE Job Reference (optional) I49399735 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:35 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-edZtg9HxyUcwMDGWOO7F3A6wrMWosbV77Wg?fHy6QqI Scale = 1:71.0 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 17 18 19 20 21 22 23 24 3x6 5x8 5x6 3x8 5x12 4x6 4x6 4x6 3x4 2x4 3x4 3x8 3x4 3x8 3x8 MT18HS 6x6 3x6 8-3-2 8-3-2 16-3-12 8-0-10 20-10-4 4-6-8 28-9-2 7-10-14 36-10-8 8-1-6 8-3-2 8-3-2 16-3-12 8-0-10 20-10-4 4-6-8 28-9-2 7-10-14 36-10-8 8-1-6 1-1-812-0-01-3-1312-0-08.00 12 Plate Offsets (X,Y)-- [5:0-5-8,0-1-12], [6:0-4-4,0-2-4], [11:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.96 0.88 0.65 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.18 -0.34 0.08 (loc) 14-16 14-16 10 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 181 lb FT = 20% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 4-5,1-4: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-14,5-13,6-13: 2x4 SPF No.2, 9-10: 2x4 SPF-S Stud SLIDER Left 2x8 SP 2400F 2.0E 5-2-0 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (4-10-15 max.): 5-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-14, 5-13, 7-13 REACTIONS. (size)1=Mechanical, 10=Mechanical Max Horz 1=205(LC 11) Max Grav 1=1722(LC 17), 10=1682(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-2379/9, 3-5=-1707/95, 5-6=-1332/111, 6-7=-1702/96, 7-9=-2183/15, 9-10=-1559/15 BOT CHORD 1-16=0/1938, 14-16=0/1938, 13-14=0/1414, 11-13=0/1721 WEBS 3-16=0/476, 3-14=-672/84, 5-14=0/648, 6-13=0/626, 7-13=-597/82, 7-11=-9/254, 9-11=0/1528 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=37ft; eave=5ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-0-0 to 3-8-4, Interior(1) 3-8-4 to 16-3-12, Exterior(2E) 16-3-12 to 20-10-4, Exterior(2R) 20-10-4 to 26-0-13, Interior(1) 26-0-13 to 36-8-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Refer to girder(s) for truss to truss connections. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. December 23,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss T06 Truss Type Piggyback Base Qty 4 Ply 1 LOT# 67 SUNRISE Job Reference (optional) I49399736 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:36 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-6p6FtUIZjokn_Nriy5eUcOe9wlsVb0EHMAPZBky6QqH Scale = 1:71.1 1 2 3 4 5 6 7 8 9 17 16 15 14 13 12 11 10 18 19 20 21 22 23 24 25 3x6 5x8 5x6 3x8 5x12 4x6 4x6 3x6 3x4 2x4 3x4 3x8 2x4 4x8 4x8 2x4 5x8 3x6 8-3-2 8-3-2 16-3-12 8-0-10 20-10-4 4-6-8 28-9-2 7-10-14 33-5-4 4-8-2 36-10-8 3-5-4 8-3-2 8-3-2 16-3-12 8-0-10 20-10-4 4-6-8 28-9-2 7-10-14 36-10-8 8-1-6 1-1-812-0-01-3-1312-0-08.00 12 Plate Offsets (X,Y)-- [5:0-5-12,0-2-0], [6:0-4-4,0-2-4], [7:0-3-12,0-2-0], [9:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.75 0.85 0.81 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.16 -0.30 0.07 (loc) 12-14 15-17 10 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 185 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 4-5,1-4: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-15,5-14,6-14: 2x4 SPF No.2, 7-11,9-10: 2x4 SPF-S Stud SLIDER Left 2x8 SP 2400F 2.0E 5-2-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals, and 2-0-0 oc purlins (5-5-9 max.): 5-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-15, 5-14, 7-14, 7-11 REACTIONS. (size)1=Mechanical, 11=0-3-8, 10=Mechanical Max Horz 1=205(LC 11) Max Uplift 10=-19(LC 12) Max Grav 1=1586(LC 17), 11=1609(LC 18), 10=237(LC 24) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-2151/16, 3-5=-1479/102, 5-6=-1086/118, 6-7=-1418/104 BOT CHORD 1-17=0/1764, 15-17=0/1764, 14-15=0/1223, 12-14=0/1098, 11-12=0/1098 WEBS 3-17=0/479, 3-15=-693/84, 5-15=0/653, 5-14=-279/42, 6-14=0/469, 7-12=0/346, 7-11=-1792/0 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=37ft; eave=5ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-0-0 to 3-8-4, Interior(1) 3-8-4 to 16-3-12, Exterior(2E) 16-3-12 to 20-10-4, Exterior(2R) 20-10-4 to 26-0-13, Interior(1) 26-0-13 to 36-8-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. December 23,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss T07 Truss Type Piggyback Base Qty 1 Ply 1 LOT# 67 SUNRISE Job Reference (optional) I49399737 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:37 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-a0gd4qJBU6sebXQvVp9j9bBJF9GEKUQQaq96jAy6QqG Scale = 1:75.5 1 2 3 4 5 6 7 8 18 17 16 15 14 13 12 11 9 19 20 21 22 23 24 25 26 10 3x6 5x6 5x8 3x8 3x4 3x6 3x4 5x8 2x4 4x8 3x4 3x4 3x6 5x8 2x4 5x8 3x6 6-3-14 6-3-14 12-5-4 6-1-6 16-3-12 3-10-8 20-10-4 4-6-8 28-9-2 7-10-14 33-7-0 4-9-14 36-10-8 3-3-8 8-3-2 8-3-2 16-3-12 8-0-10 20-10-4 4-6-8 28-9-2 7-10-14 36-10-8 8-1-6 1-1-812-0-01-3-1312-0-08.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-14], [4:0-4-4,0-2-4], [5:0-5-12,0-2-0], [8:0-3-8,Edge], [11:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.78 0.63 0.75 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.15 -0.28 0.03 (loc) 11-13 11-13 9 l/defl >999 >901 n/a L/d 240 180 n/a PLATES MT20 Weight: 177 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 4-14,5-14,5-13: 2x4 SPF No.2, 1-18,8-9: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-6-12 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 14-16. WEBS 1 Row at midpt 3-16, 4-14, 5-14, 6-13 REACTIONS.All bearings 0-3-8 except (jt=length) 9=3-7-0. (lb) - Max Horz 18=204(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 9 Max Grav All reactions 250 lb or less at joint(s) 10 except 18=726(LC 17), 16=1392(LC 17), 9=1101(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-819/32, 3-4=-724/119, 4-5=-481/132, 5-6=-926/114, 6-8=-1416/50, 1-18=-630/23, 8-9=-1055/35 BOT CHORD 17-18=-134/360, 16-17=-5/641, 14-16=-336/76, 13-14=0/687, 11-13=0/1066 WEBS 3-17=0/263, 3-16=-1410/54, 3-14=0/914, 5-14=-589/2, 5-13=0/684, 6-13=-605/100, 1-17=0/443, 8-11=0/935 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=37ft; eave=5ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-1-12 to 3-10-0, Interior(1) 3-10-0 to 16-3-12, Exterior(2E) 16-3-12 to 20-10-4, Exterior(2R) 20-10-4 to 26-0-13, Interior(1) 26-0-13 to 36-8-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. December 23,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss T08 Truss Type Piggyback Base Qty 5 Ply 1 LOT# 67 SUNRISE Job Reference (optional) I49399738 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:38 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-2CE?IAKpFP?VDh?53WgyhpkUzZaS3wmZpUugGcy6QqF Scale = 1:75.1 1 2 3 4 5 6 7 8 9 10 18 17 16 15 14 13 12 11 19 20 21 22 23 24 25 26 27 3x6 5x6 6x8 3x6 3x4 3x6 3x4 6x8 2x4 4x8 3x4 3x4 2x4 5x8 5x12 4x6 4x6 3x6 6-3-14 6-3-14 12-5-4 6-1-6 16-3-12 3-10-8 20-10-4 4-6-8 28-10-14 8-0-10 37-2-0 8-3-2 8-3-2 8-3-2 16-3-12 8-0-10 20-10-4 4-6-8 28-10-14 8-0-10 37-2-0 8-3-2 38-0-8 0-10-8 1-1-812-0-01-1-812-0-08.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-14], [4:0-4-4,0-2-4], [5:0-4-8,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.78 0.76 0.81 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.14 -0.25 0.04 (loc) 9-11 9-11 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 188 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 4-14,5-14,5-13: 2x4 SPF No.2, 1-18: 2x4 SPF-S Stud SLIDER Right 2x8 SP 2400F 2.0E 5-2-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-5. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 14-16. WEBS 1 Row at midpt 3-16, 4-14, 5-14, 7-13 REACTIONS. (size)18=0-3-8, 16=0-3-8, 9=0-3-8 Max Horz 18=-201(LC 10) Max Uplift 18=-16(LC 12), 9=-14(LC 12) Max Grav 18=707(LC 18), 16=1480(LC 17), 9=1318(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-807/68, 3-4=-737/143, 4-5=-492/151, 5-7=-954/129, 7-9=-1631/43, 1-18=-617/48 BOT CHORD 17-18=-121/358, 16-17=-2/610, 14-16=-383/48, 13-14=0/705, 11-13=0/1214, 9-11=0/1214 WEBS 3-17=0/267, 3-16=-1518/3, 3-14=0/998, 5-14=-648/0, 5-13=0/729, 7-13=-733/81, 7-11=0/475, 1-17=0/434 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=37ft; eave=5ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-1-12 to 3-10-6, Interior(1) 3-10-6 to 16-3-12, Exterior(2E) 16-3-12 to 20-10-4, Exterior(2R) 20-10-4 to 26-1-5, Interior(1) 26-1-5 to 38-0-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 18, 9. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. December 23,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss TG01 Truss Type ROOF SPECIAL GIRDER Qty 1 Ply 3 LOT# 67 SUNRISE Job Reference (optional) I49399739 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:40 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-?bMmjsL3m1FCS_8TBxjQmEpukNKZXrtsHoNmKVy6QqD Scale = 1:89.4 1 2 3 4 5 6 7 8 14 13 12 11 10 91516171819202122 3x6 4x6 4x10 5x6 6x8 3x6 6x8 4x6 10x10 4x10 4x6 4x6 5x6 Special Special Special Special Special Special Special Special Special Special Special 5-10-45-10-4 14-6-48-8-0 20-4-155-10-11 21-11-111-6-12 24-0-8 2-0-13 5-10-45-10-4 11-6-05-7-12 20-4-158-10-15 21-11-111-6-12 23-6-11 1-7-024-0-8 0-5-13 1-5-04-0-12-4-01-2-1412-11-01-0-912.00 12 12.84 12 8.25 12 4.86 12 Plate Offsets (X,Y)-- [3:0-1-4,0-1-12], [8:0-2-9,0-2-6], [9:0-2-8,0-2-0], [10:0-2-8,0-2-0], [13:0-2-8,0-6-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.57 0.46 0.70 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.10 -0.18 0.01 (loc) 11-13 11-13 11 l/defl >999 >961 n/a L/d 240 180 n/a PLATES MT20 Weight: 488 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x8 SP 2400F 2.0E WEBS 2x3 SPF No.2 *Except* 3-11,4-11: 2x4 SPF No.2, 1-14: 2x4 SPF-S Stud SLIDER Right 2x4 SPF-S Stud 0-9-9 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (size)8=0-3-8, 14=0-3-8, 11=0-3-8 Max Horz 14=-228(LC 6) Max Uplift 8=-309(LC 21) Max Grav 8=124(LC 14), 14=5157(LC 2), 11=9007(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-4904/0, 3-4=-127/438, 4-5=0/823, 5-6=0/1186, 6-7=-87/480, 7-8=-127/420, 1-14=-4089/0 BOT CHORD 13-14=-91/552, 11-13=0/3398, 10-11=-802/0, 9-10=-426/35, 8-9=-272/81 WEBS 3-13=0/6141, 3-11=-4581/0, 4-11=-1085/0, 5-11=-148/440, 5-10=-722/0, 6-10=-528/0, 6-9=0/949, 1-13=0/3034 NOTES- 1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x8 - 2 rows staggered at 0-4-0 oc. Webs connected as follows: 2x3 - 1 row at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 8=309. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1606 lb down at 2-0-12, 1606 lb down at 4-0-12, 1598 lb down at 6-0-12, 1591 lb down at 8-0-12, 1602 lb down at 10-0-12, 1606 lb down at 12-0-12, 1606 lb down at 14-0-12, 217 lb down and 39 lb up at 16-0-12, 217 lb down and 39 lb up at 18-0-12, and 217 lb down and 39 lb up at 20-0-12, and 217 lb down and 39 lb up at 22-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. Continued on page 2 December 23,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss TG01 Truss Type ROOF SPECIAL GIRDER Qty 1 Ply 3 LOT# 67 SUNRISE Job Reference (optional) I49399739 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:40 2021 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-?bMmjsL3m1FCS_8TBxjQmEpukNKZXrtsHoNmKVy6QqD LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 4-6=-60, 6-7=-60, 7-8=-60, 8-14=-20 Concentrated Loads (lb) Vert: 12=-1449(F) 13=-1449(F) 10=-217(F) 9=-217(F) 15=-1449(F) 16=-1449(F) 18=-1449(F) 19=-1449(F) 20=-1449(F) 21=-217(F) 22=-217(F) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss TG02 Truss Type Common Girder Qty 1 Ply 3 LOT# 67 SUNRISE Job Reference (optional) I49399740 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:41 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-Tnw8wCMhXKN348jgkfEfJRM1wmY3GEA0VS7Ksxy6QqC Scale = 1:78.2 1 2 3 4 5 6 7 8 9 10 15 14 13 12 11161718192021222324252627 4x8 5x8 4x6 3x8 3x8 8x16 10x10 8x16 3x4 5x6 2x4 5x6 12x12 2x4 5x8 8x8 Special Special Special Special Special Special Special Special Special Special Special 8-8-12 8-8-12 17-2-0 8-5-4 25-7-4 8-5-4 34-4-0 8-8-12 5-11-0 5-11-0 11-6-8 5-7-8 17-2-0 5-7-8 22-9-8 5-7-8 28-5-0 5-7-8 34-4-0 5-11-0 1-1-812-6-131-1-88.00 12 Plate Offsets (X,Y)-- [5:0-1-8,0-2-0], [15:0-6-0,0-7-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.67 0.96 0.96 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.17 -0.30 0.06 (loc) 13-15 13-15 10 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 854 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x6 SPF No.2 *Except* 1-4,8-10: 2x6 SP 2400F 2.0E BOT CHORD 2x10 SP 2400F 2.0E *Except* 12-14: 2x10 SP No.1 WEBS 2x3 SPF No.2 *Except* 6-13,7-13,5-13: 2x4 SPF No.2 SLIDER Left 2x8 SP 2400F 2.0E 3-3-15 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-8-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=0-3-8 (req. 0-3-9), 10=0-3-8 Max Horz 1=195(LC 7) Max Grav 1=12991(LC 2), 10=7500(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-16905/0, 3-5=-16756/0, 5-6=-10924/0, 6-7=-10883/0, 7-9=-11887/0, 9-10=-12088/0 BOT CHORD 1-15=0/13452, 13-15=0/11682, 11-13=0/9488, 10-11=0/9522 WEBS 6-13=0/11694, 7-13=-853/8, 7-11=0/1062, 9-11=0/661, 5-13=-4692/0, 5-15=0/7058, 3-15=0/1038 NOTES- 1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc. Bottom chords connected as follows: 2x10 - 2 rows staggered at 0-4-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x3 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=34ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) WARNING: Required bearing size at joint(s) 1 greater than input bearing size. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1643 lb down at 2-0-12, 1643 lb down at 4-0-12, 1643 lb down at 6-0-12, 1643 lb down at 8-0-12, 1636 lb down at 10-0-12, 1628 lb down at 12-0-12, 1633 lb down at 14-0-12, 1506 lb down at 16-0-12, 1506 lb down at 18-0-12, and 1498 lb down at 20-0-12, and 1491 lb down at 22-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard Continued on page 2 December 23,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss TG02 Truss Type Common Girder Qty 1 Ply 3 LOT# 67 SUNRISE Job Reference (optional) I49399740 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:41 2021 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-Tnw8wCMhXKN348jgkfEfJRM1wmY3GEA0VS7Ksxy6QqC LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-6=-60, 6-10=-60, 1-10=-20 Concentrated Loads (lb) Vert: 14=-1449(B) 16=-1449(B) 17=-1449(B) 18=-1449(B) 19=-1449(B) 20=-1449(B) 21=-1449(B) 23=-1331(B) 24=-1331(B) 25=-1331(B) 26=-1331(B) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss V01 Truss Type Valley Qty 1 Ply 1 LOT# 67 SUNRISE Job Reference (optional) I49399741 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:42 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-xzUW8YNKIeVwiIIsIMlusfuKTA4l?sa9k6stPOy6QqB Scale = 1:62.0 1 2 3 4 5 6 7 8 14 13 12 11 10 9 15 16 173x4 4x6 3x6 3x4 3x6 20-5-15 20-5-15 20-6-3 0-0-4 10-3-10 10-3-10 19-2-9 8-10-15 20-6-3 1-3-10 0-0-41-4-1110-3-100-0-412.00 12 12.84 12 Plate Offsets (X,Y)-- [7:0-3-0,0-1-2] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.17 0.16 0.24 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 8 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 74 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 7-8: 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 1-13: 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-11 REACTIONS.All bearings 20-5-11. (lb) - Max Horz 1=176(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 1, 8, 12, 14, 10, 9 Max Grav All reactions 250 lb or less at joint(s) 1, 8 except 11=319(LC 17), 12=495(LC 17), 14=336(LC 17), 10=462(LC 18), 9=330(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-12=-287/156, 5-10=-287/155 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-3-12 to 3-3-12, Interior(1) 3-3-12 to 10-3-10, Exterior(2R) 10-3-10 to 13-3-10, Interior(1) 13-3-10 to 20-2-13 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are 2x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 8, 12, 14, 10, 9. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. December 23,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss V02 Truss Type Valley Qty 1 Ply 1 LOT# 67 SUNRISE Job Reference (optional) I49399742 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:43 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-PA2uLuNy3xdnJSt2s4G7OsRSlaOekKoJzmcRxqy6QqA Scale = 1:57.0 1 2 3 4 5 9 8 7 6 10 11 12 13 3x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 2x4 17-11-1 17-11-1 17-11-5 0-0-4 8-11-10 8-11-10 17-11-5 8-11-10 0-0-48-11-100-0-412.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.26 0.31 0.18 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 57 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-7 REACTIONS.All bearings 17-10-13. (lb) - Max Horz 1=152(LC 11) Max Uplift All uplift 100 lb or less at joint(s) except 9=-112(LC 12), 6=-112(LC 12) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=300(LC 17), 9=549(LC 17), 6=549(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-343/190, 4-6=-343/190 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-3-12 to 3-3-12, Interior(1) 3-3-12 to 8-11-10, Exterior(2R) 8-11-10 to 11-11-10, Interior(1) 11-11-10 to 17-7-9 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 112 lb uplift at joint 9 and 112 lb uplift at joint 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. December 23,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss V03 Truss Type Valley Qty 1 Ply 1 LOT# 67 SUNRISE Job Reference (optional) I49399743 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:44 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-tMbGYEOaqFlexcSFQnnMx4_f8_mPTnLSBQL_TGy6Qq9 Scale = 1:49.6 1 2 3 4 5 8 7 6 9 10 11 123x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 0-0-4 0-0-4 15-3-5 15-3-1 7-7-10 7-7-10 15-3-5 7-7-10 0-0-47-7-100-0-412.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.16 0.15 0.16 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 52 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 15-2-13. (lb) - Max Horz 1=128(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 8, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=322(LC 17), 8=445(LC 17), 6=445(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-279/180, 4-6=-278/180 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-4-4 to 3-7-10, Interior(1) 3-7-10 to 7-7-10, Exterior(2R) 7-7-10 to 10-7-10, Interior(1) 10-7-10 to 14-11-1 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. December 23,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss V04 Truss Type Valley Qty 1 Ply 1 LOT# 67 SUNRISE Job Reference (optional) I49399744 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:45 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-LY9fmZPCbZtVZm1RzUIbTHWoVO6kCF8bQ35X?iy6Qq8 Scale = 1:41.6 1 2 3 4 5 8 7 6 9 10 11 123x4 3x4 3x4 2x4 2x4 2x4 2x4 2x4 0-0-4 0-0-4 12-7-5 12-7-1 6-3-10 6-3-10 12-7-5 6-3-10 0-0-46-3-100-0-412.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.31 0.14 0.13 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 36 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 12-6-13. (lb) - Max Horz 1=106(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 8, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=330(LC 17), 8=374(LC 17), 6=373(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-3-14 to 3-3-14, Interior(1) 3-3-14 to 6-3-10, Exterior(2R) 6-3-10 to 9-3-10, Interior(1) 9-3-10 to 12-3-7 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 8, 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. December 23,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss V05 Truss Type Valley Qty 1 Ply 1 LOT# 67 SUNRISE Job Reference (optional) I49399745 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:46 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-plj1zvQqMs?MAvcdXCqq0V3vLnPNxidlfjq5Y9y6Qq7 Scale = 1:33.3 1 2 3 4 5 6 2x4 3x6 2x4 2x4 0-0-4 0-0-4 9-11-5 9-11-1 4-11-10 4-11-10 9-11-5 4-11-10 0-0-44-11-100-0-412.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.56 0.37 0.11 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 23 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=9-10-13, 3=9-10-13, 4=9-10-13 Max Horz 1=-83(LC 10) Max Uplift 1=-11(LC 12), 3=-11(LC 12) Max Grav 1=209(LC 1), 3=209(LC 1), 4=336(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-3-0 to 3-3-0, Interior(1) 3-3-0 to 4-11-10, Exterior(2R) 4-11-10 to 7-11-10, Interior(1) 7-11-10 to 9-8-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. December 23,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss V06 Truss Type Valley Qty 1 Ply 1 LOT# 67 SUNRISE Job Reference (optional) I49399746 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:47 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-IxHPBFRS7A7Do3Bq5vL3Zic6SBoQgAxuuNae4by6Qq6 Scale = 1:25.1 1 2 3 4 5 6 2x4 3x4 2x4 2x4 0-0-4 0-0-4 7-3-5 7-3-1 3-7-10 3-7-10 7-3-5 3-7-10 0-0-43-7-100-0-412.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.41 0.19 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=7-2-13, 3=7-2-13, 4=7-2-13 Max Horz 1=-59(LC 10) Max Uplift 1=-15(LC 12), 3=-15(LC 12) Max Grav 1=162(LC 1), 3=162(LC 1), 4=218(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-3-0 to 3-3-0, Interior(1) 3-3-0 to 3-7-10, Exterior(2R) 3-7-10 to 6-7-10, Interior(1) 6-7-10 to 7-0-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. December 23,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss V07 Truss Type Valley Qty 1 Ply 1 LOT# 67 SUNRISE Job Reference (optional) I49399747 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:47 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-IxHPBFRS7A7Do3Bq5vL3ZicAEBpIgALuuNae4by6Qq6 Scale = 1:14.3 1 2 3 4 2x4 3x4 2x4 2x4 0-0-4 0-0-4 4-7-5 4-7-1 2-3-10 2-3-10 4-7-5 2-3-10 0-0-42-3-100-0-412.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.17 0.07 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-7-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=4-6-13, 3=4-6-13, 4=4-6-13 Max Horz 1=-36(LC 10) Max Uplift 1=-9(LC 12), 3=-9(LC 12) Max Grav 1=98(LC 1), 3=98(LC 1), 4=132(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. December 23,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss V08 Truss Type Valley Qty 1 Ply 1 LOT# 67 SUNRISE Job Reference (optional) I49399748 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:48 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-m7rnObR4uUF4QDl0fdsI5w8NOb91Pdr261JBc1y6Qq5 Scale = 1:7.6 1 2 3 2x4 2x4 2x4 0-0-4 0-0-4 1-11-5 1-11-1 0-11-10 0-11-10 1-11-5 0-11-10 0-0-40-11-100-0-412.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.01 0.04 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 3 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-11-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=1-10-13, 3=1-10-13 Max Horz 1=-13(LC 10) Max Grav 1=57(LC 1), 3=57(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. December 23,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss V09 Truss Type Valley Qty 1 Ply 1 LOT# 67 SUNRISE Job Reference (optional) I49399749 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:49 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-EJP9cxSjfnNx1NKCCKNXe7hTK?Tf8?rBLh3l9Uy6Qq4 Scale = 1:62.2 1 2 34 5 6 7 89 10 11 19 18 17 16 15 14 13 12 20 21 4x6 3x4 4x6 3x4 3x6 3x4 30-5-7 30-5-7 15-2-11 15-2-11 30-5-7 15-2-11 0-0-410-1-130-0-48.00 12 Plate Offsets (X,Y)-- [3:0-3-0,Edge], [9:0-3-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.32 0.14 0.34 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 11 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 93 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-15 REACTIONS.All bearings 30-5-7. (lb) - Max Horz 1=-159(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 1, 17, 18, 19, 14, 13, 12 Max Grav All reactions 250 lb or less at joint(s) 1, 11 except 15=361(LC 17), 17=457(LC 17), 18=409(LC 17), 19=351(LC 17), 14=456(LC 18), 13=409(LC 18), 12=350(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 5-17=-259/96, 7-14=-259/96 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-5-11 to 3-2-11, Interior(1) 3-2-11 to 15-2-11, Exterior(2R) 15-2-11 to 18-3-3, Interior(1) 18-3-3 to 29-11-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are 2x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 17, 18, 19, 14, 13, 12. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. December 23,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss V10 Truss Type Valley Qty 1 Ply 1 LOT# 67 SUNRISE Job Reference (optional) I49399750 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:50 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-iWzYpHTLQ5VofXvOm2umALDgZOpTtUALaLoIhwy6Qq3 Scale = 1:54.8 1 2 3 4 5 6 7 13 12 11 10 9 8 14 15 16 173x4 4x6 3x4 3x6 26-5-7 26-5-7 13-2-11 13-2-11 26-5-7 13-2-11 0-0-48-9-130-0-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.23 0.17 0.20 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 86 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-10 REACTIONS.All bearings 26-5-7. (lb) - Max Horz 1=134(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 12, 13, 9, 8 Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 10=367(LC 17), 12=422(LC 17), 13=490(LC 17), 9=422(LC 18), 8=490(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-13=-293/98, 6-8=-293/98 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=26ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-5-12 to 3-5-12, Interior(1) 3-5-12 to 13-2-11, Exterior(2R) 13-2-11 to 16-2-11, Interior(1) 16-2-11 to 25-11-10 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are 2x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 13, 9, 8. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. December 23,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss V11 Truss Type Valley Qty 1 Ply 1 LOT# 67 SUNRISE Job Reference (optional) I49399751 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:52 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-eu4IEzUbxilVvq3nuTwFGmJ1_CVJLOcd1fHPloy6Qq1 Scale = 1:49.2 1 2 3 4 5 6 7 13 12 11 10 9 8 14 15 3x4 4x6 3x4 3x6 22-5-7 22-5-7 11-2-11 11-2-11 22-5-7 11-2-11 0-0-47-5-130-0-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.17 0.14 0.21 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 68 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 1-12: 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 22-5-7. (lb) - Max Horz 1=-112(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 11, 13, 9, 8 Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 10=357(LC 17), 11=431(LC 17), 13=342(LC 17), 9=428(LC 18), 8=342(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-11=-264/97, 5-9=-265/98 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-5-0 to 3-2-11, Interior(1) 3-2-11 to 11-2-11, Exterior(2R) 11-2-11 to 14-2-11, Interior(1) 14-2-11 to 21-11-10 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are 2x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 13, 9, 8. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. December 23,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss V12 Truss Type Valley Qty 1 Ply 1 LOT# 67 SUNRISE Job Reference (optional) I49399752 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:52 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-eu4IEzUbxilVvq3nuTwFGmJ?aCTeLQud1fHPloy6Qq1 Scale = 1:40.4 1 2 3 4 5 9 8 7 6 10 11 12 133x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 2x4 18-5-7 18-5-7 9-2-11 9-2-11 18-5-7 9-2-11 0-0-46-1-130-0-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.26 0.32 0.12 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 49 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 18-5-7. (lb) - Max Horz 1=-92(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 9, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=318(LC 17), 9=515(LC 17), 6=515(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-324/113, 4-6=-324/113 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-5-0 to 3-5-0, Interior(1) 3-5-0 to 9-2-11, Exterior(2R) 9-2-11 to 12-2-11, Interior(1) 12-2-11 to 18-0-6 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. December 23,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss V13 Truss Type Valley Qty 1 Ply 1 LOT# 67 SUNRISE Job Reference (optional) I49399753 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:53 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-65egRIVDi0uMW_ezRASUozrAYcsH4tenGJ1yIFy6Qq0 Scale = 1:31.2 1 2 3 4 5 8 7 6 9 10 3x4 3x4 3x4 2x4 2x4 2x4 2x4 2x4 14-5-7 14-5-7 7-2-11 7-2-11 14-5-7 7-2-11 0-0-44-9-130-0-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.31 0.10 0.09 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 36 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 14-5-7. (lb) - Max Horz 1=71(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 8, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=259(LC 1), 8=321(LC 23), 6=321(LC 24) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-5-11 to 3-2-11, Interior(1) 3-2-11 to 7-2-11, Exterior(2R) 7-2-11 to 10-2-11, Interior(1) 10-2-11 to 13-11-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. December 23,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss V14 Truss Type Valley Qty 1 Ply 1 LOT# 67 SUNRISE Job Reference (optional) I49399754 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:54 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-aHC2feWrTK0D88DA?tzjLBOH_09upKGwVzmWqhy6Qq? Scale = 1:24.2 1 2 3 4 5 6 3x4 6x18 MT18HS 3x4 2x4 10-5-7 10-5-7 5-2-11 5-2-11 10-5-7 5-2-11 0-0-43-5-130-0-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.52 0.20 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 MT18HS Weight: 24 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=10-5-7, 3=10-5-7, 4=10-5-7 Max Horz 1=-50(LC 10) Max Uplift 1=-7(LC 12), 3=-7(LC 12) Max Grav 1=186(LC 1), 3=186(LC 1), 4=388(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) 0-5-11 to 3-5-11, Interior(1) 3-5-11 to 5-2-11, Exterior(2R) 5-2-11 to 8-2-11, Interior(1) 8-2-11 to 9-11-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. December 23,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job B21100270 Truss V15 Truss Type Valley Qty 1 Ply 1 LOT# 67 SUNRISE Job Reference (optional) I49399755 8.430 s Aug 16 2021 MiTek Industries, Inc. Wed Dec 22 11:18:55 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-3TmQs_XTEd84mIoMZbUytOxWkPW7Yo94jdW3M7y6Qq_ Scale = 1:16.3 1 2 3 4 2x4 3x4 2x4 2x4 6-5-7 6-5-7 3-2-11 3-2-11 6-5-7 3-2-11 0-0-42-1-130-0-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.26 0.14 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=6-5-7, 3=6-5-7, 4=6-5-7 Max Horz 1=30(LC 11) Max Uplift 1=-9(LC 12), 3=-9(LC 12) Max Grav 1=123(LC 1), 3=123(LC 1), 4=214(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. December 23,2021 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.21.The design does not take into account any dynamic or other loads other than those expressly stated.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3- 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths