Loading...
HomeMy WebLinkAboutC600 - Storm Plan & Profile-C60075 L.F. 0.30% 12" R.C.P. CLASS III 848.51 848.74 SCALE: 1"=50' HOR. 1"=5' VERT. 840 850 860 840 850 860 8" SDR-35 PVC INV.=845.42EXMOOR DRIVE8" WATER 30 L.F. 0.30% 18" R.C.P. CLASS III UP INV.=847.90 DOWN INV.=847.81 135 L.F. 0.30% 15" R.C.P. CLASS III 848.00 848.41 6"S.S.D.6"S.S.D. 6"S.S.D. 6"S.S.D.YARD INLET #G4STA. 1+65TC=856.80R-4342CURB INLET #G3STA. 0+30TC=857.14R-3501-TRCURB INLET #G2STA. 0+00TC=857.14R-3501-TLYARD INLET #G5STA. 2+40TC=859.43R-4342EXISTING GRADE PROPOSED GRADE HYDRAULIC GRADE LINE54" COVERSCALE: 1"=50' HOR. 1"=5' VERT. 830 840 850 830 840 850 161 L.F. 0.31% 12" R.C.P. CLASS III 838.00 838.50END SECTION #A1STA. 0+00(w/ DEBRIS GUARD)OUTLET CONTROL #A2STA. 1+61TC=847.25SEE DETAILEXISTING GRADE PROPOSED GRADE HYDRAULIC GRADE LINE EX. 8' PATH N.P. 844.50 o o o SCALE: 1"=50' HOR. 1"=5' VERT. 835 840 850 860 835 840 850 860 112 L.F. 0.18% 21" R.C.P. CLASS III 845.67 845.87MANHOLE #B6STA. 3+50TC=852.50R-1772ALLEYEXMOOR DRIVECURB INLET #B3STA. 0+96TC=852.41R-3501-TLCURB INLET #B3STA. 0+96TC=852.41R-3501-TL104.7" COVER8" WATER18"MIN13 L.F. 0.52% 18" R.C.P. CLASS III UP INV.=847.81 DOWN INV.=847.75 103 L.F. 0.30% 21" R.C.P. CLASS III 845.27 845.57 62 L.F. 0.30% 24" R.C.P. CLASS III UP INV.=844.95 DOWN INV.=844.77 34 L.F. 0.49% 24" R.C.P. CLASS III UP INV.=844.67 DOWN INV.=844.50 6"S.S.D. 6"S.S.D.MANHOLE w/2' SUMP #B2STA. 0+34TC=851.37(2) R-3501-TL/TRCURB INLET #B3STA. 0+96TC=852.41R-3501-TLCURB INLET #B4STA. 1+36TC=853.43R-3405YARD INLET #B5STA. 2+38TC=853.93R-4342MANHOLE #B8STA. 4+80TC=855.50R-1772END SECTION #B1STA. 0+00(w/ DEBRIS GUARD)MANHOLE #B6STA. 3+50TC=852.50R-177221" R.C.P. CLASS III N INV.=845.05 24" R.C.P. CLASS III S INV.=844.95 15" R.C.P. CLASS III NW INV.=846.54 EXISTING GRADE PROPOSED GRADE HYDRAULIC GRADE LINE 18'' RCP N INV.=846.35 21'' RCP S INV.=845.87 6'' HDPE NW INV.=848.61 12'' RCP E INV.=846.85 62 L.F. 1.37% 18" R.C.P. CLASS III UP INV.=847.56 DOWN INV.=846.71 18" R.C.P. CLASS III N INV.=847.81 18" R.C.P. CLASS III S INV.=847.81CURB INLET #G2STA. 5+76TC=857.14R-3501-TL18" R.C.P. CLASS III NW INV.=846.71 18" R.C.P. CLASS III S INV.=846.62 18" R.C.P. CLASS III NE INV.=846.71MANHOLE #B7STA. 4+18TC=853.81R-177283 L.F. 0.10% 18" R.C.P. CLASS III UP INV.=847.75 DOWN INV.=847.66 6" S.D.R. 35 P.V.C INV.=843.63 8" SDR-35 PVC INV.=842.63 68 L.F. 0.39% 18" R.C.P. CLASS III UP INV.=846.62 DOWN INV.=846.35 40 L.F. 0.30% 21" R.C.P. CLASS III UP INV.=845.17 DOWN INV.=845.05 MANHOLE #G1STA. 5+63TC=857.42R-17726"S.S.D. SCALE: 1"=50' HOR. 1"=5' VERT. 835 840 850 860 835 840 850 860 EXMOOR DRIVE70 L.F. 0.30% 15" R.C.P. CLASS III 846.54846.75 30 L.F. 0.30% 15" R.C.P. CLASS III UP INV.=846.94 DOWN INV.=846.85 6"S.S.D.6"S.S.D.DBL. CURB INLET #C2STA. 1+00TC=852.85(2) R-3501-TL/TRCURB INLET #C1STA. 0+70TC=852.85R-3501-TRCURB INLET #B3STA. 0+00TC=852.41R-3501-TL21" R.C.P. CLASS III N INV.=845.05 24" R.C.P. CLASS III S INV.=844.95 15" R.C.P. CLASS III NW INV.=846.54 EXISTING GRADE PROPOSED GRADE HYDRAULIC GRADE LINE 6" S.D.R. 35 P.V.C INV.=843.82 6"S.S.D. SCALE: 1"=50' HOR. 1"=5' VERT. 835 840 850 860 835 840 850 860 EXMOOR DRIVE30 L.F. 0.30% 12" R.C.P. CLASS III UP INV.=847.46 DOWN INV.=847.37 6"S.S.D.6"S.S.D.CURB INLET #D2STA. 0+51TC=852.60R-3501-TRCURB INLET #D1STA. 0+21TC=852.60R-3501-TLEXISTING GRADE PROPOSED GRADE HYDRAULIC GRADE LINEMANHOLE #B6STA. 0+00TC=852.50R-177218'' RCP N INV.=846.35 21'' RCP S INV.=845.87 6'' HDPE NW INV.=848.61 12'' RCP E INV.=846.85 SCALE: 1"=50' HOR. 1"=5' VERT. 835 840 850 860 835 840 850 860 MENDENHALL DRIVEEXMOOR DRIVE8" WATER 18"MIN160 L.F. 0.37% 18" R.C.P. CLASS III UP INV.=847.30 DOWN INV.=846.71 15 L.F. 0.30% 15" R.C.P. CLASS III UP INV.=847.45 DOWN INV.=847.40 30 L.F. 0.30% 15" R.C.P. CLASS III UP INV.=847.64 DOWN INV.=847.55104.9" COVER6"S.S.D. 6"S.S.D.MANHOLE #E1STA. 1+60TC=852.80R-1772CURB INLET #E2STA. 1+75TC=853.44R-3501-TLCURB INLET #E3STA. 2+05TC=853.44R-3501-TRPROPOSED GRADE EXISTING GRADE HYDRAULIC GRADE LINE 18" R.C.P. CLASS III NW INV.=846.71 18" R.C.P. CLASS III S INV.=846.62 18" R.C.P. CLASS III NE INV.=846.71MANHOLE #B7STA. 0+00TC=853.81R-1772SCALE: 1"=50' HOR. 1"=5' VERT. 835 840 850 860 835 840 850 860 MENDENHALL DRIVE51 L.F. 0.30% 15" R.C.P. CLASS III UP INV.=847.70 DOWN INV.=847.55 15 L.F. 0.30% 15" R.C.P. CLASS III UP INV.=847.85 DOWN INV.=847.80 30 L.F. 0.30% 12" R.C.P. CLASS III UP INV.=848.04 DOWN INV.=847.95 6"S.S.D.6"S.S.D.MANHOLE #F2STA. 0+51TC=852.31R-1772CURB INLET #F3STA. 0+66TC=852.95R-3501-TLCURB INLET #F4STA. 0+96TC=852.95R-3501-TREND SECTION #F1STA. 0+00(w/ DEBRIS GUARD)EXISTING GRADE PROPOSED GRADE HYDRAULIC GRADE LINE C.A. #26 S S S S S P.W.P. P.W.P. P.W.P. P.W.P. W SS 35'43' 12'35'27'62'43'2'31'2'12' 47' 20'27'C.O.841.70C.O.841.59C.O.842.52S EX. 8' P A T H 845 845 850 8 5 5 8 6 0 846 84 6 847 847 84 8 8 4 9 8 5 1 8 5 2 8 5 3 8 5 4 8 5 6 8 5 7 8 5 8 8 5 9 845850855 860 843844846847848849851851 851 852 853 854 856 857 858 859 861 862 863 84284 2 843 843 8408398418428 4 0 8 4 1 8 4 2 8 4 3 845850842843844846847848849851851863863864862 8 4 5 8448 4 6 8 4 6 8 4 7 8 4 7 84 0 84 1 8 4 2 8 4 3 8448 4 08398 4 1 842843847848 849 845 842 843844 846 840 840838838839839 841841841840841 841841842840 841 845 842 843 844 846 84 7 840837838839 836837 838 839837 8 3 7 8 3 8 839 8 5 0 8558 4 6 8 4 7 8488498518528538548 4 5 8428 4 3 8 4 48458 4 2 84 3 8 4 4 84 5 84 5 85 0 844 844846 847 848 8 4 9 851 852853855854 856 85 7 85 8 8 5 9 8408 4 1 8 4 2 8 5 5853854 85 0 847 848 849 8 5 1 8 4 5 8 4 3 8 4 4 850 847 848 849851 852 853 846847848849840839 839 841 842842843 84 0 8418458 4 4 846846847848849 8 5 0 5' SIDEWALK5' SIDEWALK5' SIDEWALK JG607 JG715 JG719 JG716 JG717 JG718 JG606 JG834 334335336337338 339 343 344 345 346 347 348 349 350 351 352 353 354 355 30' B-BW W W W W W W W W WWWWWWWWWWWWWW WWWWWWWWWWWWWEXMOOR DRIVE MEN DE N H ALL DRI VE EXM O O R D R IV E EXMOOR DRIVEEXMOOR DRIVE30' B-B3 0 ' B - B 30' B-B 150 L.F. 6" SSD RISER T.C.=861.1 5' SIDEWALK 10' B. L . 10' B.L.10' B.L. 10' B.L.10' B.L.10' B.L.10' B.L.1 0 ' B . L . 1 0 ' B . L . 1 0 ' B . L . 10' B. L.10' B.L.10' B.L.15' D&U.E15' D&U.E2 0 ' B . L . 2 0 ' D . U . & S . S . E . 2 0 ' B . L . 2 0 ' D . U . & S . S . E . 1 0 ' D . U . & S . S . E . 1 0 ' D . U . & S . S . E . 10' D&U.E.10' D&U.E.10' D&U.E.10' D&U.E.1 0 ' D & U . E . 1 0 ' D & U . E .10' D&U.E.10' D&U.E.5' S I D EW A L K 5' S I D EW A L K 5' SIDEWALK 5' SIDEWALK 5' SIDEWALK 5' SIDEWALK5' SIDEWALKC.O. III C.O. III C.O. III C.O. III C.O. III C.O. III C.O. III C.O. III V A R . D . U . & S . S . E . VAR. D.U.&S.S.E. VAR. D.U. &S.S.E. VAR. B.M.P.E. & R.D.E. & U.E. (PRIVATE)(PRIVATE)(PRIVATE)(PRIVATE)(P R I V A T E ) 34 L.F. 24" R.C.P. @ 0.49% 62 L.F. 24" R.C.P. @ 0.30% 70 L . F . 1 5 " R . C . P . @ 0 . 3 0 % 30 L.F. 15" R.C.P. @ 0.30% 40 L.F. 21" R.C.P. @ 0.30% 103 L.F. 21" R.C.P. @ 0.30% 13 L.F. 18" R.C.P. @ 0.52% 30 L.F. 12" R.C.P. @ 0.30% 21 L.F. 12" R.C.P. @ 0.82%160 L.F. 18" R.C.P. @ 0.37% 30 L.F. 18" R.C.P. @ 0.30%135 L.F. 15" R.C.P. @ 0.30%15 L.F. 15" R.C.P. @ 0.30% 30 L.F. 15" R.C.P. @ 0.30% 30 L.F. 12" R.C.P. @ 0.30% 15 L.F. 15" R.C.P. @ 0.30% 51 L.F. 15" R.C.P. @ 0.30%161 L .F . 12" R .C .P . @ 0 .31%112 L.F. 21" R.C.P. @ 0.18%75 L.F. 12" R.C.P. @ 0.30%100' WIDE TREEPRESERVATIONEASEMENTD2D1 I1 H1 E1E2 E3 F1 F2 F3 F4 G2 G3 G4 B1 B2 B3 B4 B5 B8 C1 C2 A2 A1 B6 G5 10' D&U.E.10' B.L.20' D&U.E.&RD.E VAR. D&U.E.&RD.E VAR.B.M.P.E. & R.D.E.& U.E & L.M.A.E. VAR. D.U.&S.S.E. & B.M.P.E. C.A.#8-2 108,267 sq. ft. VAR.B.M.P.E.& R.D.E. & U.E. (P R I V A T E A L L E Y ) C.A.#8-2 108,267 sq. ft. VAR.B.M.P.E.& R.D.E. & U.E. RISER T.C.=859.1 65 L.F. 6" SSD H2 B7 I2 G1 83 L.F. 18" R.C.P. @ 0.10%62 L . F . 1 8 " R . C . P . @ 1 . 3 7 % 42 L.F. 6" HDPE @ 2.38% 41 L.F. 6" HDPE @ 1.00% 42 L.F. 6" HDPE @ 1.67% 58 L.F. 6" HDPE @ 3.00% 68 L.F. 18" R.C.P. @ 0.39%WWW W W W C.A.#8-2 108,267 sq. ft. VAR.B.M.P.E.& R.D.E. & U.E. RISER T.C.=853.9 RISER T.C.=858.1 2 4 9 L . F . 6 " S S D 1 0 ' D . U . & E . C.O. C.O. C.O. w/ BEEHIVE GRATE (SEE DETAIL 1299CGD - SHEET C802) C.O. C.O. C.O. C.O.50' D.U. & S.S.E. & I.E.E. & P. A.E.50' D.U. & S.S.E.& I.E.E. & P.A.E.5 0 ' D . U . & S . S . E .& I . E . E . & P . A . E . 50' D.U. & S.S.E. & I.E.E. & P.A.E. C.O. w/ BEEHIVE GRATE (SEE DETAIL 1299CGD - SHEET C802) C.O. w/ BEEHIVE GRATE (SEE DETAIL 1299CGD - SHEET C802) SSD INV. 842.00 253 L . F . 6 " S S D @ 0 . 5 0 % TC. = 844.42 SSD INV. EL 841.92 TC. = 844.21 SSD INV. EL 841.71 TC. = 8 4 4 . 3 7 SSD IN V . E L 8 4 1 . 8 7 TC. = 8 4 4 . 1 3 SSD I N V . E L 8 4 1 . 6 3 TC. = 843.86 SSD INV. EL 841.36 TC. = 843.92 SSD INV. EL 841.42 TC. = 8 4 3 . 5 0 SSD I N V . E L 8 4 1 . 0 0 TC. = 8 4 3 . 8 0 SSD I N V . E L 8 4 1 . 3 0 SSD INV. 840.73 TC. = 843.40 SSD INV. EL 840.90 TC . = 8 4 3 . 3 0 S SD INV . E L 8 4 0 . 8 0 C.O. C.O. C.O. C.O. RISER T.C.=851.9 INV.=849.9 79 L.F. 6" SSD SSD E. INV.=849.11 60160REP-S8 KJJM BKR CARMEL, CLAY TOWNSHIPHAMILTON COUNTY, INDIANA09/16/20File Name:S:\60160REP-S8\DWG\C600 - Storm Plan & Profile.dwg - C600Modified / By:December 6, 2021 1:33:12 PM / ecarsonPlotted / By:December 6, 2021 3:01:39 PM / Erik CarsonJACKSON'S GRANT ON WILLIAMS CREEKSECTION 808/17/21REVISED PER TAC COMMENTSJDTNOTES ALL STORM STRUCTURES TO RECEIVE SOLID LID CASTINGS ARE TO BE CONSTRUCTED TO PROVIDE ONE 4" RISER RING NO MORE, NO LESS TO ACHIEVE PLAN RIM GRADE. ALL YARD INLETS ARE TO BE CONSTRUCTED AT A TOLERANCE OF +0.00' TO -0.20' OF PLAN GRADE. ALL STORM SEWER CASTINGS SHALL BE LABELED "DUMP NO WASTE-DRAINS TO WATERWAY" ALL SSD'S (SUBSURFACE DRAINS) WILL NEED TO BE DOUBLE WALL SMOOTH BORE PERFORATED (HDPE) PIPE. DEBRIS GUARDS ARE TO BE INSTALLED ON ALL OPEN ENDED INLETS. FOR STORM STRUCTURE SIZING AND CASTING TABLE SEE STANDARD PLAN D-18 ON SHEET C801A. ALL STORM SEWERS WITHIN PUBLIC RIGHT-OF-WAY SHALL BE RCP CLASS III. FOR INSTALLATION OF STORM UNDER CITY STREETS AND COVER REQUIREMENTS, SEE STANDARD DRAWING 10-31 ON SHEET C801A. ALL TOP OF CASTING ELEVATIONS FOR STORM SEWERS SHALL BE CONSTRUCTED WITH A TOLERANCE OF 0.10 FT±. STORM SEWERS FOR THIS DEVELOPMENT WILL BE PUBLIC. MINIMUM COVER FOR PIPE CROSSINGS OF CITY STREETS: THE MINIMUM COVER FROM THE TOP OF THE INSTALLED PAVEMENT TO THE TOP OF THE INSTALLED PIPE SHALL BE THE PAVEMENT SECTION, THICKNESS (ALL BITUMINOUS AND AGGREGATE MATERIAL ABOVE THE SUBGRADE) PLUS 1'-0", BUT UNDER NO CIRCUMSTANCES SHALL THE COVER ALONG ANY PART OF THE PIPE FROM THE FINAL PAVEMENT ELEVATION TO THE TOP OF THE PIPE BE LESS THAN 2.5 FEET. THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS. DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS. DEVIATIONS FROM THE APPROVED DESIGN SHALL ONLY BE PERMITTED DUE TO SPECIAL CIRCUMSTANCES OR DIFFICULTY DURING CONSTRUCTION AND WILL REQUIRE PRIOR FIELD APPROVAL FROM A DESIGNATED REPRESENTATIVE OF THE CITY OR CARMEL IN ADDITION TO SUPPLEMENTAL APPROVAL BY THE DESIGN ENGINEER. AN EXPLANATION OF ANY SUCH DEVIATION SHALL BE INCLUDED AS A REQUIREMENT ON AS-BUILT/RECORD DRAWINGS SUBMITTED FOR RELEASE OF PERFORMANCE GUARANTEES. APPROVED DESIGN SLOPES IDENTIFIED AS GENERATING VELOCITIES OF 2.5 FPS OR LESS AND 10 FPS OR GREATER (AT FULL FLOW CAPACITY) SHALL REQUIRE AS-BUILT CERTIFICATION AT THE TIME OF CONSTRUCTION, PRIOR TO BACKFILLING THE PIPE. THE CONTRACTOR IS INSTRUCTED TO AS-BUILT EACH SECTION OF STORM PIPE AS IT IS BEING INSTALLED TO ENSURE COMPLIANCE WITH THE DESIGN PLANS, AND AS APPROVED BY THE CITY OF CARMEL. UTILITY CROSSINGS CONTRACTOR SHALL VERIFY DEPTHS OF ALL EXISTING ONSITE UTILITIES PRIOR TO CONSTRUCTION TO CONFIRM THERE IS NOT ANY CONFLICTS WITH OTHER UTILITIES, STORM SEWERS OR STREETS. CONFLICTS AFTER CONSTRUCTION BEGINS ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. GRAPHIC SCALE ( IN FEET ) 1" = 50 FT LEGEND EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING WATER LINE PROPOSED SANITARY SEWER PROPOSED STORM SEWER PROPOSED WATER LINE DENOTES FULL DEPTH GRANULAR BACKFILL (SEE TRENCH DETAIL 10-31 ON SHEET C802) APPROXIMATE LIMITS OF FLOODWAY, AS SCALED FROM FIRM MAP PANEL NOS.: 18057C0206G / 208G DATED: NOVEMBER 19, 2014 APPROXIMATE LIMITS OF FLOODWAY FRINGE, AS SCALED FROM FIRM MAP PANEL NOS.: 18057C0206G / 208G DATED: NOVEMBER 19, 2014 FWF(FIRM) FWF(FIRM)DATEMARKREVISIONSBYCERTIFIED:S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY:S T O E P P E L W E R T HA L W A Y S O N7965 East 106th Street, Fishers, IN 46038-2505phone: 317.849.5935 fax: 317.849.5942THIS DRAWING IS NOT INTENDED TO BE REPRESENTED AS A RETRACEMENT OR ORIGINAL BOUNDARY SURVEY, A ROUTE SURVEY OR A SURVEYOR LOCATIONREPORT.STORM SEWER PLAN & PROFILESC600REVISED PER CITY OF CARMEL COMMENTS10/21/21AEC