Loading...
HomeMy WebLinkAboutC800 - Construction Details-C80260160REP-S8 KJJM BKR CARMEL, CLAY TOWNSHIPHAMILTON COUNTY, INDIANA09/16/20File Name:S:\60160REP-S8\DWG\C800 - Construction Details.dwg - C802Modified / By:December 6, 2021 4:35:13 PM / ecarsonPlotted / By:December 6, 2021 4:42:40 PM / Erik CarsonJACKSON'S GRANT ON WILLIAMS CREEKSECTION 808/17/21REVISED PER TAC COMMENTSJDT"A" * DIA.WALL G or T WT. SEC A B C D E DIA. +1 R-1 R-2 SKIRT 12 2 1 1/2 530 4 24 48 1/8 72 7/8 24 13 10 1/16 9 3 1/2 15 2 1/4 2 740 6 27 46 73 30 16 12 1/2 11 3 1/2 18 2 1/2 2 1/2 990 9 27 46 73 36 19 15 1/2 12 4 21 2 3/4 2 1/4 1280 9 35 38 73 42 22 16 1/8 13 4 24 3 2 1/2 1520 9 1/2 43 1/2 30 73 1/2 48 25 16 11/16 14 4 1/2 27 3 1/4 2 1/2 1930 10 1/2 48 25 1/2 73 1/2 54 28 17 3/4 14 1/2 4 1/2 30 3 1/2 3 2190 12 54 19 3/4 73 3/4 60 31 18 5/16 15 5 33 3 3/4 3 3/8 3150 13 1/3 58 1/2 39 1/4 97 3/4 66 34 23 3/4 17 1/2 5 1/2 36 4 3 1/2 4100 15 63 34 3/4 97 3/4 72 37 24 1/16 20 5 1/2 42 4 1/2 3 3/4 5380 21 63 35 98 78 43 27 1/4 22 5 1/2 48 5 4 1/4 6550 24 72 26 98 84 49 28 1/8 22 5 3/4 54 5 1/2 4 3/4 8040 27 65 35 100 90 55 32 7/8 24 6 1/4 60 6 5 8750 30 60 39 99 96 61 36 3/4 24 6 3/4 66 6 1/2 5 1/2 10630 24 78 21 99 102 67 35 11/16 24 7 1/4 72 7 6 12520 34 78 21 99 108 73 38 5/8 24 7 3/4 78 7 1/2 6 1/2 14430 24 78 21 99 114 79 41 15/16 24 8 1/2 84 8 7 16350 24 78 21 99 120 85 44 13/16 24 9WALLEDDIA.SKIRT C B DIA. +1ADIA.WALLWALL0.0704'WALLR- 2 1 1 2" RR-1 DIA. 1 12" RR-1 DIA. 1/32 TAPER PER INCH PER SIDE "A" "B" "B" HORIZONTAL FLARE VERTICAL FLARE SECTION B-B SECTION A-A NOTES: MANUFACTURE OF END SECTION IS IN ACCORDANCE WITH APPLICABLE PORTIONS OF A.S.T.M. SPECIFICATION C76. PRECASE CONCRETE END SECTION DETAIL 36"x36" 30"x30" 6" 24"x24" 2.5' MIN. GRADE SEE STRUCTURE DATA CHART FOR CASTING TYPESPAVEMENT CONCRETE CURB NOTE: MAXIMUM 48 INCHES FROM T/C TO INVERT NOTE: ALL CASTINGS SHALL BE LABELED "DUMP NO WASTE". NOTE TO CONTRACTOR: THE CITY OF CARMEL REQUIRES DOUBLE WALL HANCOR HI-Q SSD PIPE OR EQUAL TO BE USED. NOTES: All storm sewers shall be constructed with reinforced concrete pipe Class III or as noted and conform to A.S.T.M. C-76 or latest revision. All manholes shall be precast concrete construction in accordance with State of Indiana Specifications and shall have Type "A" cast iron ring and cover. The storm sewer system shall be constructed per design specified and as approved by the City of Carmel on the final approved construction plans. Deviations from the approved design shall only be permitted due to special circumstances or difficulty during construction and will require prior field approval from a designated representative of the City of Carmel in addition to supplemental approval by the design engineer. An explanation of any such deviation shall be included as a requirement on as-built/record drawings submitted for release of performance guarantees. Approved design slopes identified as generating velocities of 2.5 fps or less or 10 fps or greater (at full flow capacity) shall require as-built certification at the time of construction, prior to backfilling the pipe. The contractor is instructed to as-built each section of storm pipe as it is being installed to ensure compliance with the design plans and as approved by the City of Carmel. NOT-TO-SCALE (GROOVE-OUTLET END) (TONGUE-INLET END) WEEP HOLES FOR CASTING TYPES SEE STRUCTURE DATA CHART FINISH GRADE 2'-0" 4" VARIES 0'-3" MIN. 2.5' MIN. YARD INLET CATCH BASIN NOT-TO-SCALE CURB INLET CATCH BASIN NOT-TO-SCALE REINFORCED CONC. PIPE CONCRETE BASE DATEMARKREVISIONSBYCERTIFIED:S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY:S T O E P P E L W E R T HA L W A Y S O N7965 East 106th Street, Fishers, IN 46038-2505phone: 317.849.5935 fax: 317.849.5942THIS DRAWING IS NOT INTENDED TO BE REPRESENTED AS A RETRACEMENT OR ORIGINAL BOUNDARY SURVEY, A ROUTE SURVEY OR A SURVEYOR LOCATIONREPORT.STORM SEWER DETAILSC802ADDED CROSS SECTION FOR BASIN 12E10/04/21AECREVISED PER CITY OF CARMEL COMMENTS10/21/21AEC36"6"24"36" 6" 24" PLAN ELEVATION 8" 11" CLASS "A" CONCRETE PRECAST 24" x 24" BOX INLET NOT-TO-SCALE VARIESVARIES (48" MAX.)8"VARIESELEVATIONCLASS "A" CONCRETE PRECAST 30" x 30" BOX INLET NOT-TO-SCALE 2"2"2"2" 3" (2) #5 x 3'-0" IN EACH WALL 6" 42" 6" 2 1 4"42"6" 6"30"2 1 4" 30" PLAN NEENAH CASTING R-4215-C CROSS SECTION 12C