A0.01 Foundation - Basement
PROVIDE 10' MIN. SEPARATION BETWEEN WATER & SEWER LINES (PER CODE) EJECTOR PIT AND PUMP - VERIFY LOCATION IN FIELDSUMP w/ CHECK VALVE - VERIFY LOCATION IN FIELDRADON VENT PER CODE, VERIFY LOCATIONWATER HEATER, PER SPEC. VERIFY LOCATION IN FIELD \pxqr; WATER SOFTENER, PER SPEC. SLAB LEDGE, PER DETAIL \A1;1'-3" \A1;13'-0"\A1;2'-2" \A1;4'-2" SHOWER TB TR TP \A1;7'-5{\H0.75x;\S1#2;}" FURNACE, PER SPEC. VERIFY LOCATION W/ MECHANICAL PLANS \A1;12'-9" LEAD WALL PAST OVERDIG, TYP. (SEE STRUCTURAL)UNEXCAVATED(SEE STRUCTURAL PLANS)CONCRETE SLAB 4140 SL & EGRESS WELL #4, AS REQUIRED BY CODE\PSEE STRUCTURAL DETAILS 2A2 3A2 4140 SL \P& EGRESS \PWELL #3, AS \PREQUIRED \PBY CODE SEE \PSTRUCTURAL \PDETAILS 3A2 2A2 \A1;18'-11" \A1;6'-4{\H0.75x;\S1#2;}" POST & BEAM PER STRUCTURAL PLANS 8' CLG.STORAGE1A2 1A2\A1;4'-0"\A1;2'-0" \A1;10'-4" \A1;12'-3" \A1;1'-8" \A1;1'-8" \A1;32'-8" \A1;2'-0"\A1;10'-0" \A1;3'-7" \A1;3'-11" \A1;2'-4" \A1;3'-11" \A1;6'-7" \A1;3'-11" \A1;3'-10{\H0.75x;\S1#2;}" \A1;14'-1" \A1;6'-0" \A1;12'-0" \A1;4'-0"\A1;2'-0" \A1;10'-4" \A1;12'-3" \A1;1'-8" \A1;1'-8" \A1;32'-8" \A1;6'-0" \A1;12'-0"\A1;9'-8{\H0.75x;\S1#2;}"\A1;2'-0"\A1;3{\H0.75x;\S1#2;}" \A1;10'-3{\H0.75x;\S1#2;}" \A1;11'-6" \A1;8'-8{\H0.75x;\S1#2;}" \A1;12'-7{\H0.75x;\S1#2;}"\A1;11'-4" \A1;24'-11" \A1;2'-4{\H0.75x;\S1#2;}" \A1;6'-4{\H0.75x;\S1#2;}" \A1;8'-0{\H0.75x;\S1#2;}" \A1;15'-8" \A1;2'-0"\A1;10'-0"\A1;12'-0" SLOPEUNEXCAVATED(SEE STRUCTURAL PLANS)CONCRETE SLAB\A1;1'-4" \A1;2'-0"\A1;10'-0"\A1;32'-11{\H0.75x;\S1#2;}"\A1;23'-11{\H0.75x;\S1#2;}"\A1;2'-2"\A1;8'-3"\A1;1'-9"\A1;16'-3"\A1;4'-6{\H0.75x;\S1#2;}" \A1;68'-11" OVERALL\A1;9'-7{\H0.75x;\S1#2;}"\A1;47'-7" \A1;20'-7" \A1;8'-8{\H0.75x;\S1#2;}" \A1;13'-4{\H0.75x;\S1#2;}" \A1;17'-3" \A1;68'-11" OVERALL\A1;56'-11"\A1;12'-0" \A1;15'-4"\A1;1{\H0.75x;\S1#2;}" \A1;8'-4" \A1;3'-0"\A1;2'-0" \A1;59'-11" OVERALL \A1;1'-7{\H0.75x;\S1#2;}"\A1;2'-2" \A1;4'-7" \A1;2'-2" \A1;2'-10" \A1;2'-2"\A1;3'-5" \A1;10'-4" LEAD WALL PAST OVERDIG, FIELD VERIFY LOCATION\P(TYP.) PERIMETER DRAIN, PER SPEC UNEXCAVATED(SEE STRUCTURAL PLANS)PORCH\A1;37'-3{\H0.75x;\S1#2;}" \A1;59'-11" OVERALL \A1;6'-8" \A1;7'-9" \A1;13'-3{\H0.75x;\S1#2;}" \A1;1'-3{\H0.75x;\S1#2;}" \A1;12'-0" \A1;2'-0"\A1;TYP.\A1;2'-0"\A1;TYP. A0.01 FOUNDATION - BASEMENTMidwest Zone Office1900 Golf Road - Suite 300Schaumburg, Illinois 60173(c) Copyright 2015 PulteGroup, Inc. PRODUCT MANAGERRick StarkeyVERSION RELEASEDATE:xx/xx/xxxxPROJECT TYPE Single Family SHEET PLAN NAME SPECIFICATION LEVEL NPC CHILD NUMBER ---- Skyview 2056.300Home for * Market Home *, 7231-025002881 Trailblazer Court, Carmel, IN 46032BASEMENT FOUNDATION PLANSCALE: 1/4" = 1'-0" (HALF SCALE ON 11x17 PAPER) Alternate Sump Location 01/21/22