Loading...
HomeMy WebLinkAboutA4.01 Roof PlanMIN. 22 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "C" 3.5:12 MIN. 303 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "A" MIN. 22 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "C" 3.5:12 MIN. 303 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "A" 4:12 10:12 10:12 8:12 8:12 ELEVATION HR3XATTIC VENT SCHEDULEVENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATIONROOF AREA "A"SQ FTG2421AT / NEAR RIDGEAT / NEAR EAVEVENT TYPESQ. FT.REQUIREDRANGESQ. FT.SUPPLIEDPERCENTOF TOTALSUPPLIEDPOT LARGE(SQ. IN. EACH)POT SMALL(SQ. IN. EACH)RIDGE VENT(SQ. IN. PER LF)EAVE VENT(SQ. IN. EACH)CONT. VENT(SQ. IN. PER LF)61.0040.0018.0028.0010.00HIGH - POTVENTS ONLY3.234.044.2450.00100AT EAVE4.844.044.2450.00061.00TOTAL (MIN)8.078.078.47100.003 HIGH -RIDGE VENT3.234.044.1349.750033.00AT EAVE4.844.044.1750.25060.00TOTAL (MIN)8.078.078.29100.00ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLEELEVATION HR3XROOF AREA "B"SQ FTG617AT / NEAR RIDGEAT / NEAR EAVEVENT TYPESQ. FT.REQUIREDRANGESQ. FT.SUPPLIEDPERCENTOF TOTALSUPPLIEDPOT LARGE(SQ. IN. EACH)POT SMALL(SQ. IN. EACH)RIDGE VENT(SQ. IN. PER LF)EAVE VENT(SQ. IN. EACH)CONT. VENT(SQ. IN. PER LF)61.0040.0018.0028.0010.00HIGH - POTVENTS ONLY0.821.031.2749.0630AT EAVE1.231.031.3250.94019.00TOTAL (MIN)2.062.062.59100.003 HIGH -RIDGE VENT0.821.031.0047.37008.00AT EAVE1.231.031.1152.63016.00TOTAL (MIN)2.062.062.11100.00ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE10:1210:1210:1210:123.5:128:128:128:12\A1;1'-0"\PTYP.8:128:124:1210:1210:1210:1210:123.5:1210:128:12PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATIONMIN. 12 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "D"\A1;8'-0"\A1;26'-0"GUTTER AND DOWNSPOUTSPOT VENTS\A1;7'-0""B"617ROOF AREA:SQ. FT."A"2421ROOF AREA:SQ. FT.A4.01 ROOF PLANMidwest Zone Office1900 Golf Road - Suite 300Schaumburg, Illinois 60173(c) Copyright 2015 PulteGroup, Inc. PRODUCT MANAGERRick StarkeyVERSION RELEASEDATE:xx/xx/xxxxPROJECT TYPE Single Family SHEET PLAN NAME SPECIFICATION LEVEL NPC CHILD NUMBER ---- Skyview 2056.300Home for * Market Home *, 7231-025002881 Trailblazer Court, Carmel, IN 46032ROOF PLANSCALE: 1/4" = 1'-0" (HALF SCALE ON 11x17 PAPER) 01/21/22