HomeMy WebLinkAboutS101.0 - Proposed Floor PlanN
EXISTING 2X4 FRAMING
DEMOLITION & FRAMING KEY
NO DEMO IN THIS ROOM
EXISTING 2X6 FRAMING
WALL SECTION TO BE REMOVED
NEW 2x4 FRAMING
NEW 2X6 FRAMING
BULK HEAD / LOWERED CEILING
268026682468FLOOR FLOORR
R4 R4
GFI
GFI
TT
R
AA
BB 2'-6"10'-9 3/4"F1F1
PRIMARY BATH
C.H. 11'-5" AFF
TILE
F2F2
F3F3
F4F4
F5F5
F7F7
VERIFY WINDOW IS TEMPERED.
WINDOW WILL NEED TEMPERED
FILM APPLIED TO EXISTING
WINDOW SASH FOR ANY GLASS
BELOW 60" A.F.F.
11068
11068 2068CEILINGCEILINGGFI
GFI
R
3
3
SECOND
FLOOR BATH
C.H. 7'-11 7/8" AFF
TILE
F1F1
F6F6
F2F2
FRAMING PLAN NOTES
NOTE QTY DESCRIPTION
2
INSTALL NEW SUBFLOOR AS NECESSARY FROM DEMO AND
MECHANICAL ROUGH INS. FINAL SCOPE TO BE
DETERMINED FOLLOWING MECHANICAL ROUGH INS.
3 PROVIDE BLOCKING FOR CABINET INSTALLATION AND
BATHROOM ACCESSORIES
1 FRAME SHOWER SHELF AND NICHE PER TILE DETAIL
DRAWINGS.
2 INSTALL BLOCKING FOR SHOWER GLASS INSTALLATION
1 FRAME NEW HALF WALL ATTACHED TO CABINETRY. FINAL
WALL HEIGHT TBD
1 INSTALL BLOCKING FOR SHOWER GLASS BARN DOOR
INSTALLATION
1 FRAME NEW 30X80 DOORWAY INTO ADJACENT CLOSET. NO
CASING
F1F1
F2F2
F3F3
F4F4
F5F5
F6F6
F7F7
F1F1
F2F2
F3F3
F4F4
F5F5
F6F6
F7F7
INSULATION PLAN NOTES
NOTE QTY DESCRIPTION
1 FOAM AND FIRECAULK ALL MECHANICAL OPENINGS PER
MUNICIPAL CODE REQUIREMENTS
1 NO OTHER INSULATION WORK IS IN THE CURRENT SCOPE
OF WORK.
I1I1
I2I2
I1I1
I2I2
DRYWALL PLAN NOTES
NOTE QTY DESCRIPTION
1
DRYWALL FINISH:
CEILING - TEXTURED
WALLS - LEVEL 4
1
INSTALL NEW DRYWALL ON ALL NEWLY FRAMED WALLS.
PATCH ALL AREAS NECESSARY FROM DEMO AND
MECHANICAL ROUGH INS. MATCH EXISTING DRYWALL
FINISH. INCLUDE DRYWALL PATCH FOLLOWING
COUNTERTOP INSTALLATION. FINAL SCOPE TO BE
DETERMINED FOLLOWING MECHANICAL ROUGH INS
1
INSTALL NEW DRYWALL ON ALL CEILINGS NECESSARY
FROM DEMO AND MECHANICAL ROUGH INS. MATCH
EXISTING CEILING FINISH IN HOME. FINAL SCOPE TO BE
DETERMINED FOLLOWING MECHANICAL ROUGH INS.
D1D1
D2D2
D3D3
D1D1
D2D2
D3D3 256826682268
211681116823682468CEILING
3
3
3
RR
R R
R
3
R
GFI
8'-2 15/16"
BASEMENT KITCHEN
C.H. 7'-6 13/16" AFF
TILE
KENDALL'S BATH
C.H. 8'-8 1/4" AFF
TILE
F4F4 F2F2
CLAYMON RESIDENCEInterior Remodel12982 Treaty Line StreetCarmel, IN 46032Date:Revision:
A3
SHEET OF 8
SIGNATURE / SEALDESIGNER: BAYLEE FLORENCEE: baylee@customlivingusa.comC: 219.713.4954Client Initials:
Date:
The plans, including all text, drawings, concepts, and ideas
forming a part of the plans and the selection and arrangement
thereof are Copyright 2018 of Custom Living, Inc., Indianapolis,
IN. ALL RIGHTS RESERVED. The plans shall remain the
property of Custom Living Inc. Any use of the plans or their
content without the prior written permission of Custom Living Inc.
is strictly prohibited.CUSTOM LIVING5335 Winthrop AveIndianapolis IN 462201/20/22
DATE:
[PRINTS TO SCALE IF PRINTED ON 24" X 36" ]
GENERAL PROPOSED PLAN NOTES
Framing contractors are responsible for all labor,
for the scope of work specified on the drawings
provided by Custom Living.
Owner understands that Custom Living has only
provided a labor and material allowance for the
scope of Rough Carpentry work specified on
the drawings. Any additional work added or
uncovered during this scope will be filed as a
Change Order during construction
Owner understands that the drywall allowance is
based on an estimated board count and square
footage take-off. A final walk through with a
drywall contractor after framing and mechanical
rough-ins will be necessary to finalize drywall
installation and finish budgets.
Final drywall touch-ups will follow countertop
installation.
PROPOSED FLOOR PLAN
SCALE: 1/2" = 1'
TYPICAL FRAMING DETAIL
SCALE: 3/8" = 1' 0"
01/24/22