Loading...
HomeMy WebLinkAboutS101.0 - Proposed Floor PlanN EXISTING 2X4 FRAMING DEMOLITION & FRAMING KEY NO DEMO IN THIS ROOM EXISTING 2X6 FRAMING WALL SECTION TO BE REMOVED NEW 2x4 FRAMING NEW 2X6 FRAMING BULK HEAD / LOWERED CEILING 268026682468FLOOR FLOORR R4 R4 GFI GFI TT R AA BB 2'-6"10'-9 3/4"F1F1 PRIMARY BATH C.H. 11'-5" AFF TILE F2F2 F3F3 F4F4 F5F5 F7F7 VERIFY WINDOW IS TEMPERED. WINDOW WILL NEED TEMPERED FILM APPLIED TO EXISTING WINDOW SASH FOR ANY GLASS BELOW 60" A.F.F. 11068 11068 2068CEILINGCEILINGGFI GFI R 3 3 SECOND FLOOR BATH C.H. 7'-11 7/8" AFF TILE F1F1 F6F6 F2F2 FRAMING PLAN NOTES NOTE QTY DESCRIPTION 2 INSTALL NEW SUBFLOOR AS NECESSARY FROM DEMO AND MECHANICAL ROUGH INS. FINAL SCOPE TO BE DETERMINED FOLLOWING MECHANICAL ROUGH INS. 3 PROVIDE BLOCKING FOR CABINET INSTALLATION AND BATHROOM ACCESSORIES 1 FRAME SHOWER SHELF AND NICHE PER TILE DETAIL DRAWINGS. 2 INSTALL BLOCKING FOR SHOWER GLASS INSTALLATION 1 FRAME NEW HALF WALL ATTACHED TO CABINETRY. FINAL WALL HEIGHT TBD 1 INSTALL BLOCKING FOR SHOWER GLASS BARN DOOR INSTALLATION 1 FRAME NEW 30X80 DOORWAY INTO ADJACENT CLOSET. NO CASING F1F1 F2F2 F3F3 F4F4 F5F5 F6F6 F7F7 F1F1 F2F2 F3F3 F4F4 F5F5 F6F6 F7F7 INSULATION PLAN NOTES NOTE QTY DESCRIPTION 1 FOAM AND FIRECAULK ALL MECHANICAL OPENINGS PER MUNICIPAL CODE REQUIREMENTS 1 NO OTHER INSULATION WORK IS IN THE CURRENT SCOPE OF WORK. I1I1 I2I2 I1I1 I2I2 DRYWALL PLAN NOTES NOTE QTY DESCRIPTION 1 DRYWALL FINISH: CEILING - TEXTURED WALLS - LEVEL 4 1 INSTALL NEW DRYWALL ON ALL NEWLY FRAMED WALLS. PATCH ALL AREAS NECESSARY FROM DEMO AND MECHANICAL ROUGH INS. MATCH EXISTING DRYWALL FINISH. INCLUDE DRYWALL PATCH FOLLOWING COUNTERTOP INSTALLATION. FINAL SCOPE TO BE DETERMINED FOLLOWING MECHANICAL ROUGH INS 1 INSTALL NEW DRYWALL ON ALL CEILINGS NECESSARY FROM DEMO AND MECHANICAL ROUGH INS. MATCH EXISTING CEILING FINISH IN HOME. FINAL SCOPE TO BE DETERMINED FOLLOWING MECHANICAL ROUGH INS. D1D1 D2D2 D3D3 D1D1 D2D2 D3D3 256826682268 211681116823682468CEILING 3 3 3 RR R R R 3 R GFI 8'-2 15/16" BASEMENT KITCHEN C.H. 7'-6 13/16" AFF TILE KENDALL'S BATH C.H. 8'-8 1/4" AFF TILE F4F4 F2F2 CLAYMON RESIDENCEInterior Remodel12982 Treaty Line StreetCarmel, IN 46032Date:Revision: A3 SHEET OF 8 SIGNATURE / SEALDESIGNER: BAYLEE FLORENCEE: baylee@customlivingusa.comC: 219.713.4954Client Initials: Date: The plans, including all text, drawings, concepts, and ideas forming a part of the plans and the selection and arrangement thereof are Copyright 2018 of Custom Living, Inc., Indianapolis, IN. ALL RIGHTS RESERVED. The plans shall remain the property of Custom Living Inc. Any use of the plans or their content without the prior written permission of Custom Living Inc. is strictly prohibited.CUSTOM LIVING5335 Winthrop AveIndianapolis IN 462201/20/22 DATE: [PRINTS TO SCALE IF PRINTED ON 24" X 36" ] GENERAL PROPOSED PLAN NOTES Framing contractors are responsible for all labor, for the scope of work specified on the drawings provided by Custom Living. Owner understands that Custom Living has only provided a labor and material allowance for the scope of Rough Carpentry work specified on the drawings. Any additional work added or uncovered during this scope will be filed as a Change Order during construction Owner understands that the drywall allowance is based on an estimated board count and square footage take-off. A final walk through with a drywall contractor after framing and mechanical rough-ins will be necessary to finalize drywall installation and finish budgets. Final drywall touch-ups will follow countertop installation. PROPOSED FLOOR PLAN SCALE: 1/2" = 1' TYPICAL FRAMING DETAIL SCALE: 3/8" = 1' 0" 01/24/22