Loading...
HomeMy WebLinkAboutPLANS 16-ENG-80 RIVER ROAD PHASE 2SHEET NO. TYPICAL CROSS SECTIONS INDEX OF DRAWINGS TITLE SHEET & INDEX 1 MAINTENANCE OF TRAFFIC ROAD PLAN & PROFILES CROSS SECTIONS COMMUNITY DRIVE TO 146th STREET CITY OF CARMEL RIVER ROAD RECONSTRUCTION PHASE 2 PROJECT NO. 16-ENG-80 PAVEMENT MARKING & SIGNING DETAILS EROSION CONTROL DETAILS PLAT NO. 1 2-3 4-6 7 8-15 16-25 30-33 XS2-XS29 PROJECT NO. 16-ENG-80 - RIVER ROAD RECONSTRUCTIONDevelopment ConsultantsTransportation & MILES GRAPHIC SCALES 2.00 0.5 0 1.00 END PROJECT STA. 90+55 "PR-A" 232122 1924 14 13 181516 3025262728 HAMILTON CO. C L A Y 146th St. Main St. 141st St. 131st St.Allisonville Rd.S.R. 37Hazel Dell Rd.River Rd.BEGIN PROJECT STA. 44+79 "PR-A" Tall Timber Run UTILITIES AT&T 5858 N. College Ave. Indianapolis, IN 46220 Contact: Jake Greenwald Ph: (317) 801-1924 CHARTER 3030 Roosevelt Ave. Indianapolis, IN 46218 Contact: Joe Burton Ph: (317) 339-9075 CITIZENS ENERGY GROUP 2150 Dr. MLK Jr. Blvd Indianapolis, IN 46202 Contact: Mike Picklesimer Ph: (317) 965-2166 CITY OF CARMEL WATER UTILITY 4915 W. 106th Street Carmel, IN 46033 Contact: John Duffy Ph: (317) 571-2443 COMCAST 5330 E. 65th Street Indianapolis, IN 45220 Contact: Thomas Spencer Ph: (317) 776-5326 DUKE ENERGY 100 S. Mill Creek Rd. Noblesville, IN 46062 Contact: Brynn Streeter Ph: (317) 703-0681 VECTREN ENERGY 16000 Allisonville Rd. Noblesville, IN 46061 Contact: Joanie Clark Ph: (317) 776-5532 ROAD SUMMARY TABLES CITY OF CARMEL STANDARDS FOR CONSTRUCTION OF REQUIRED IMPROVEMENTS, INDIANA DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS DATED 2016, INDOT SUPPLEMENTAL SPECIFICATIONS. CONSTRUCTION DETAILS 26SPOT ELEVATION SHEET 29GEOMETRIC SHEET 43-45STRUCTURE DATA TABLES 46-47UNDERDRAIN TABLES 42 50-58LANDSCAPE DETAILS 34-41 27-28ROUNDABOUT CONTOURS CROSS SECTION SAMPLE LINES PROJECT DESCRIPTION ROAD RECONSTRUCTION PROJECT ON RIVER ROAD FROM COMMUNITY DRIVE TO 146TH STREET IN CARMEL. LOCATED IN SECTION 23, T-18-N, R-4-E CLAY TOWNSHIP, HAMILTON COUNTY, INDIANA. XS1 LIGHTING DETAILS 48 WATER LINE DETAILS 49 HONORABLE JAMES BRAINARD, MAYOR FINAL CONSTRUCTION DOCUMENTS WPO N TE E. SINTE E T RINE N GEER A NDNI LONAOE F I SS I A STATE OF 19700381 RGE DE RRT PR DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: TYPSEC.dwgDATE/USER: 1/8/2017 12:01 PM / ToddM.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE TYPICAL CROSS SECTIONS 1/4" = 1'-0" N/A 2'-0"Varies 6' to 29'Varies 16'-0" to 26'-0"2'-0" Profile Grade 2%K 1518 26 SG TYPICAL CROSS SECTION Line "PR-A" & "PR-A1" 2'-0"Varies 0' to 10'2'-0" 2%K15 18 26 SG 10'-0" P 1.5% 2%2% R STA. 44+94 "PR-A" to STA. 57+81.39 "PR-A" STA. 57+81.39 "PR-A1" to STA. 61+22 "PR-A1" Varies 16'-0" to 34'-0" *Slopes Vary, See Cross Sections U 4" U 1'-0"Conduit\Interduct 4" 27 8% 5'-0" 2:1 (M a x ) 2:1 ( M a x ) * * 2%2%2:1 ( M a x ) * 8% 5'-0" 2:1 (Ma x ) * Varies1'1' Path Grade 2'-0"Varies 0' to 29'Varies 16'-0" to 26'-0"2'-0" Profile Grade 2%K 1518 26 SG TYPICAL CROSS SECTION Line "PR-A2" & "PR-A" 2'-0"Varies 8' to 29'2'-0" 2%K15 18 26 SG 2%2% STA. 62+55 "PR-A2" to STA. 65+43.07 "PR-A2" STA. 65+43.07 "PR-A" to STA. 80+05 "PR-A" Varies 16'-0" to 38'-0" U 4" U 1'-0" 3'-0" Cover Conduit\Interduct 4" 8% 5'-0" 2%2% Varies10'-0" P 26 1.5% 2:1 (M a x ) 2:1 ( M a x ) * * 6'-0" to 24'-0" 2'-0"Varies 6' to 8'16'-0"2'-0" Profile Grade 15 26 TYPICAL CROSS SECTION Line "PR-A" 2'-0"Varies 0' to 8'2'-0" 2%15 18 26 2% STA. 80+05 "PR-A" to STA. 86+72 "PR-A" Varies 16'-0" to 38'-0" 4" 5'-0" 2% Varies10'-0" P 261.5% 3'-0" to 33'-0" Exist. Pavement Path Grade 1.5% 8% 3:1 (Ma x ) 3:1 ( M a x ) 5'-0" 26 ** R 2'-0"26'-0" Profile Grade TYPICAL CROSS SECTION Line "PR-A" 2'-0" 2%15 STA. 86+72 "PR-A" to STA. 88+72 "PR-A" U 5'-0"Varies10'-0" P 261.5% 3'-0" to 33'-0" Exist. Pavement Path Grade 8% 3:1 (Ma x ) 3:1 ( M a x ) 5'-0" 26 **4" K 26'-0" 4'-0" Varies K 18 SG 4" U 1'-0" Conduit\Interduct 278% 4:1 Varies SG U 1'-0" Conduit\Interduct 278% 4:1 Varies Varies 4:1 (Max) * 27 4:1 4:1 (Max) * ** No Underdrain From STA. 87+82 to End of Project ** ** 18 U 3'-0" Cover 3'-0" Cover 3'-0" Cover 2'-0" Typ.2'-0" Typ. VariesVaries NTS 4'-0" 4' Erosion Control Blanket Curb & Gutter Type II Subgrade Treatment, Type IB Sod Curb & Gutter Type III LEGEND K SG 15 18 26 P R HMA Pavement - Alternate No. 1 165#/SYD. HMA Surface, Type 'C', 9.5 mm on 220#/SYD. HMA Intermediate, Type 'C', 19.0 mm on 330#/SYD. HMA Base, Type 'C', 25.0 mm on 12" Compacted Aggregate #53 Base on Subgrade Treatment, Type IB (Cement) HMA for Sidewalk 165#/SYD. HMA Surface, Type 'B' on 275#/SYD. HMA Intermediate, Type 'B' on 6" Compact Aggregate #53 Base on Subgrade Treatment, Type III Subsurface DrainU HMA Pavement 165#/SYD. HMA Surface, Type 'C', 9.5 mm on 275#/SYD. HMA Intermediate, Type 'C', 19.0 mm on 385#/SYD. HMA Base, Type 'C', 25.0 mm on 250#/SYD. HMA Intermediate, Type 'C' OG, 19.0 mm on 330#/SYD. HMA Base, Type 'C', 25.0 mm on Subgrade Treatment, Type IB (Cement) Mulched Seeding, U27 Mill and Overlay Mill Existing Pavement 1.5" and Place 165#/SYD. HMA Surface Type 'C', on Variable Depth HMA Wedge & Level, Type 'C' R1 Mill Existing Pavement 1.5" and Place 165#/SYD. HMA Surface Type 'C', 9.0 mm Concrete Curb14 Modified Roll Curb16 C2 PCCP, 7" with D-1 Contraction Joints at 15' Max. Spacing on 10" Compacted Aggregate No. 53 Base on Subgrade Treatment Type IB. LandscapingL 2 DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: TYPSEC.dwgDATE/USER: 1/8/2017 12:01 PM / ToddM.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE TYPICAL CROSS SECTIONS 1/4" = 1'-0" N/A *Slopes Vary, See Cross Sections R 2'-0"26'-0" Profile Grade TYPICAL CROSS SECTION Line "PR-A" 2% STA. 88+72 "PR-A" to STA. 89+13 "PR-A" 5'-0"10'-0" P 1.5% 24'-0" Exist. Pavement Path Grade 3:1 ( M a x ) 26 * 26'-0" Varies 13' to 26' 2'-0" Varies K 18 SGTYPICAL CROSS SECTION Line "PR-A" STA. 89+13 "PR-A" to STA. 90+55 "PR-A" 4" U 1'-0" Conduit\Interduct 278% 5'-0" 4:1 Exist. Pavement R Varies 2' to 13'6'±Varies 10' to 21' Exist. Pavement Varies K 18 SG 4" U 1'-0" Conduit\Interduct 278% 4:1R Exist. Pavement 2'-0"Varies 18'-0" to 26'-0"2'-0" Profile Grade 2%K 15 SG Line "B" 4" U 8% 5'-0" 27 4:1 2% 10'-0"12' Varies 7" L 14 C2 16 Center Circle Underdrain See Detail Sheet No. __ TYPICAL CROSS SECTION STA. 0+00 "B" to STA. 3+58.14 "B" 3'-0" Cover 3'-0" Cover TYPICAL CROSS SECTION Line "W-EXIT" STA. 10+86.22 "W-EXIT" to STA. 12+72.50 "W-EXIT" (SHOULDER SECTION) STA. 12+72.50 "W-EXIT" to STA. 13+76 "W-EXIT" (CURB SECTION) 10'-0" P 26 1.5% 6'-0"16'-0"2'-0" Varies K 18 SG 4:1 1.5% 9'-0" 1.5% 5:1 (Max) Varies 37' to 21'2'-0" 18 4" 1' Varies Line "W-EXIT" 5:1 (Max) Varies 21' to 18'Varies 16'-0" to 22'-0" 2'-0" Typ. (SHOULDER SECTION) (CURB SECTION) TYPICAL CROSS SECTION Line "W-ENT" STA. 10+86.76 "W-ENT" to STA. 12+38.18 "W-ENT" (SHOULDER SECTION) STA. 12+38.18 "W-ENT" to STA. 13+39 "W-ENT" (CURB SECTION) 10'-0" P26 1.5% 6'-0"16'-0"2'-0" VariesK SG 4:1 1.5% 9'-0" 1.5% 5:1 (Max) Varies 37' to 21'2'-0" 18 4" 1' Varies Line "W-ENT" 5:1 (Max) Varies 21' to 18'Varies 16'-0" to 22'-0" (SHOULDER SECTION) (CURB SECTION) 1'-0" Conduit\Interduct 3'-0" Cover or 15 18 or 15 2'-0" Typ. Elevation = 758' 33' Elevation = 761' Curb & Gutter Type II Subgrade Treatment, Type IB Sod Curb & Gutter Type III LEGEND K SG 15 18 26 P R HMA Pavement - Alternate No. 1 165#/SYD. HMA Surface, Type 'C', 9.5 mm on 220#/SYD. HMA Intermediate, Type 'C', 19.0 mm on 330#/SYD. HMA Base, Type 'C', 25.0 mm on 12" Compacted Aggregate #53 Base on Subgrade Treatment, Type IB (Cement) HMA for Sidewalk 165#/SYD. HMA Surface, Type 'B' on 275#/SYD. HMA Intermediate, Type 'B' on 6" Compact Aggregate #53 Base on Subgrade Treatment, Type III Subsurface DrainU HMA Pavement 165#/SYD. HMA Surface, Type 'C', 9.5 mm on 275#/SYD. HMA Intermediate, Type 'C', 19.0 mm on 385#/SYD. HMA Base, Type 'C', 25.0 mm on 250#/SYD. HMA Intermediate, Type 'C' OG, 19.0 mm on 330#/SYD. HMA Base, Type 'C', 25.0 mm on Subgrade Treatment, Type IB (Cement) Mulched Seeding, U27 Mill and Overlay Mill Existing Pavement 1.5" and Place 165#/SYD. HMA Surface Type 'C', on Variable Depth HMA Wedge & Level, Type 'C' R1 Mill Existing Pavement 1.5" and Place 165#/SYD. HMA Surface Type 'C', 9.0 mm Concrete Curb14 Modified Roll Curb16 C2 PCCP, 7" with D-1 Contraction Joints at 15' Max. Spacing on 10" Compacted Aggregate No. 53 Base on Subgrade Treatment Type IB. LandscapingL 3 44+0045+0046+0047+0048+0050+0051+0052+0053+0054+0055+0056+00App. Exist. R/W App. Exi s t . R / WCOMMUNITY DR.Sec. 23, T18N, R4E Clay Township Hamilton County Connor Prairie Foundation Inc. Falcon Nest II LLC Falcon Nest II LLC THE OV E R L O O K AT THE L E G A C Y RIVER RD. Line "A" RIVER RD . P.I. = 43+52.97 "A" P.I. = 46+69.38 "A"P.I./P.C. = 49+27.06 "A"P.I. = 50+96.96 "A" P.I./P.T. = 52+65.27 "A" P.I. = 54+70.47 "A" P.I. = 56+81.42 "A" Line "PR-A"THE MEADOWSAT THE LEGACYP.I. = 50+76.78 "PR-A" BEGIN PROJECT 44+79.00 "PR-A"49+00Sec. 23, T18N, R4E Clay Township Hamilton County 57+00THE OV E R L O O K AT THE L E G A C Y A p p . P L App. Exist. R/W Proposed Drainage Easement App. Exi s t . R / WApp. Exist. R/WApp. Exist. R/WIndianapolis Water Co. Easement R/W P.O.T. 57+81.39 "PR-A" = P.O.T. 57+81.39 "PR-A1" Line "PR-A1" Line "PR-A1" P.O.T. 61+38.33 "PR-A1" = P.O.C. 2+54.03 "B" Proposed Drai n a g e E a s e m e n t BEGIN CONSTRUCTION P.T. 13+47.36 "W-ENT" = O.P.O.C. 18.00 Rt., 1+96.60 "B" M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: PLAT-1.dwgDATE/USER: 12/5/2016 11:51 AM / TbennettPLAT NO. 1 1"=50' 4 MATCH LINE 59+00 "PR-A" 60+0061+0062+0063+0065+0066+0067+0068+0069+0070+0072+0073+0074+00App. E xi st. R / W App. PLApp. PLFalcon Nest II LLC App. E xi s t. R / W P.I. = 60+98.28 "A" P.I. = 63+12.02 "A" P.I. = 65+16.24 "A" P.I. = 66+01.08 "A" P.I./P.C. = 66+65.51 "A" P.I. = 67+62.90 "A" P.I./P.T. = 68+56.53 "A" P.I. = 69+08.40 "A" P.I. = 70+08.16 "A" P.I. = 71+59.90 "A" P.I. = 74+03.47 "A" P.I. = 74+69.12 "A" P.C. = 76+60.62 "A" P.I. = 67+30.66 "PR-A" App. Exis t . R / W Connor Prairie Foundation Inc. Sec. 23, T18N, R4E Clay Township Hamilton County Falcon Nest II LLC THE OVE R L O O K AT THE L E G A C Y Sec. 23, T18N, R4E Clay Township Hamilton County R/W R/W R/WLine "PR-A" Line "A" App. PL RIVER RD. R/W71+0064+00App. Exis t . R / W App. E xi s t. R / WR/WR/WR/W Propo s e d D r ai n a g e E a s e m e n t Indianap o l i s W a t e r C o . E a s e m e n t Indian a p oli s W a t e r C o. E a s e m e n t Harvest Bible Chapel of North Indianapolis Inc.App. PL A p p . E x i s t . R /W A p p . E x i s t . R /W A p p . E x i s t . R /W A p p . E x i s t . R /WApp. Exist. R/WA p p . E x i s t . R /W A p p . E x i s t . R /WLine "W-EXIT"Line "W-ENT"R/W Line "PR-A1" Line "PR-A1"0+001+002+003+00 Line "B"P.O.T. 61+38.33 "PR-A1" = P.O.C. 2+54.03 "B" P.O.T. 14+01.41 "W-EXIT" = P.O.C. 1+49.14 "B" P.O.C. 3+18.90 "B" = P.O.T. 61+51.57 "PR-A" Line "PR-A2" P.O.T. 62+37.94 "PR-A2" = P.O.C. 0+62.48 "B" Proposed Drai n a g e E a s e m e n t P.I. = 11+23.41 "W-ENT" P.I. = 11+63.60 "W-EXIT" BEGIN CONSTRUCTION 10+86.76 "W-ENT" BEGIN CONSTRUCTION 10+86.22 "W-EXIT" P.T. 13+47.36 "W-ENT" = O.P.O.C. 18.00 Rt., 1+96.60 "B" P.O.C. 65+43.07 "PR-A2" = P.C. 65+43.07 "PR-A" P.I. = 65+25.92 "PR-A2" P.I. = 13+18.03 "W-ENT" M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: PLAT-1.dwgDATE/USER: 12/5/2016 11:51 AM / TbennettPLAT NO. 1 1"=50' 5MATCH L INE 75+00 "PR -A"MATCH LINE 59+00 "PR-A" 75+0076+0077+0078+0079+0080+0081+0082+0083+0085+0087+0088+0089+0090+0091+0092+00App. E xi st. R / W App. Exist . R / W App. E xi s t. R / W App. Exist. R / W App. Exis t . R / W App. Exist. R/W App. Exist. R/W A p p . E x i s t . R /W A p p . P L App. PLA p p . P L App. E xi s t. R / W Harvest Bible Chapel of North Indianapolis Inc. KLC Realty LLC L & Q Realty LLC P.I. = 78+43.09 "A" P.I. = 86+91.08 "A" P.T. = 80+23.78 "A" P.T. = 89+16.84 "A" P.C. = 76+60.62 "A" P.T. = 84+49.82 "A" P.I. = 77+84.50 "PR-A" P.I. = 86+70.63 "PR-A" END PROJECT 90+55.00 "PR-A" Connor Prairie Foundation Inc. Sec. 23, T18N, R4E Clay Township Hamilton County84+00Connor Prairie Foundation Inc. Sec. 23, T18N, R4E Clay Township Hamilton County 86+00App. P L RIVER RD. Line "PR-A" Line "A" 1 4 6 T H S T . M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: PLAT-1.dwgDATE/USER: 12/5/2016 11:51 AM / TbennettPLAT NO. 1 1"=50' 6MATCH LINE 75+00 "PR-A" XM4-8 M5-1(R)S M6-1S M6-3 M 4-6 M 4-8 END M5-1(L)S OR M6-1S OR XM4-8XM4-8 M5-1(R)S CLOSED ROAD CONSTRUCTION SIGNS, TYPE "A" AHEAD DETOUR AHEAD XW20-3 36" X 36" XW20-2 36" X 36" DETOUR CONSTRUCTION SIGNS, TYPE "B" XM4-10 (L) 48" X 18" DETOUR XM4-10 (R) 48" X 18" ROAD CLOSED AHEAD ROAD CLOSURE SIGN ASSEMBLIES R11-3 5' X 2'-6" R11-2 4' X 2'-6" LOCAL TRAFFIC ONLY ROAD CLOSED M5-1(L)S OR FOR SPACING OF DETOUR ROUTE MARKER ASSEMBLIES AND CONSTRUCTION SIGNING, SEE INDOT STANDARD DRAWING E 801-TCDT-01 NOTE: River Road River Road River Road River Road Main St. Haverton Way Tall Timber RunHazel Dell Pkwy146th St.River Rd.Longest D r . Silas M o f f i t t W a y Griffi n R u n Fife T r a i l Tr a d i n g P o s t P l Buckskin Ct. R11-3 XM4-10(L) R11-3 XM4-10(R) R11-2Community Dr.River Rd.M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: MOT.dwgDATE/USER: 12/6/2016 8:20 AM / MmastersonMAINTENANCE OF TRAFFIC 7 42+00 43+00 44+00 45+00 46+00 47+00 48+00 49+00 Proposed Profile @ Line "PR-A" Existing Profile @ Line "PR-A"753.32753.23753.10752.89752.57752.23751.86751.63751.37751.02750.67750.39750.14749.97749.79749.55749.32748.98748.78748.60748.63748.65748.80749.09749.50751.50750.57749.69749.64751.27751.04750.81750.34750.11749.88749.58749.53749.55749.80750.03750.32-0.93% PVI STA: 47+85 PVI EL: 748.85 VCL: 230.00 +1.60%-0.93% BEGIN PROJECT STA. 44+94.00 ELEV. 751.56 Transition Cross Slope from +3.0% to +2.0% Left+94+94Grade of Path Lt. (Plotted 20' Above Datum) -3.19% +0.00% PVI STA: 46+50 PVI EL: 746.18 VCL: 20.00 +84 751.48+54.7,17.2 Monitoring Well+93.3,40.5 Water Meter+13.6,16.7 Sign (40 MPH)+23.1,15.2 Gas Marker+36.8,13.9 Sign+33.8,26.7 Power Pole+91.5,89.1 6" Dec.+17.8,76.4 1" Dec.+34.8,14.1 Sign (Caution)+54.0,29.1 Cable Box+06.9,31.1 PP w/Riser+13.5,25.7 Sign+13.6,31.6 Sign (25 MPH)+21.0,66.4 15" Dec.+42.7,43.2 Water Valve+49.7,83.6 6" Dec.+52.5,53.2 Pin w/Cap Fnd+63.5,35.3 Mag Nail Set+73.6,44.8 Gas Vavle+95.4,53.1 Sprinkler Head+96.8,58.5 Sign (Stop)+01.1,73.6 3" Dec.+05.3,88.5 Inlet+30.4,6.1 Pin w/Cap Fnd+33.5,84.9 3" Dec.+34.1,56.1 Light Pole+55.6,89.3 Inlet+58.8,73.8 3" Dec.+59.2,42.2 Water Valve+64.0,53.5 Sprinkler Head+74.2,70.6 Yard Light+83.6,37.1 Sprinkler Head+83.7,70.2 Yard Light+99.5,37.9 Water Valve+02.7,39.2 Water Valve+03.2,72.5 3" Dec.+04.0,54.1 Fire Hyd.+12.0,34.7 Sprinkler Head+39.9,34.1 Sprinkler Head+45.7,72.3 3" Dec.+70.0,33.4 Sprinkler Head+86.4,73.0 3" Dec.+92.4,53.3 Storm M.H.+93.7,31.8 Inlet+98.3,33.0 Sprinkler Head46+28.3,72.5 3" Dec.+49.5,89.6 1" Dec.+63.4,88.3 1" Dec.+78.8,62.8 1" Con.+17.9,63.9 1" Con.+57.9,63.8 1" Con.+59.0,16.1 Sign (40 MPH)+63.1,21.5 6" Dec.+97.4,64.6 1" Con.+07.0,75.3 1" Con.+64.8,14.4 Sign (Caution)43+0042+0044+0045+0046+0047+0048+00+92.0,40.2 Air Relief Valve(grvl)+61.4,58.4 Elec. Box(sign)12" rcp12" rcp12" rcp27" Conc.(riprap) App. Exist. R/W App. Exist. 45' R/W A p p . P L COMMUNITY DR.Carmel Clay Schools Sec. 23, T18N, R4E Clay Township Hamilton County Sec. 23, T18N, R4E Clay Township Hamilton County Connor Prairie Foundation Inc. THE O V E RL O O K AT T H E L E G A C Y Falcon Nest II LLC Falcon Nest II LLC RIVER RD. Line "A" T.B.M. 404 C.P. 116 P.I. = 43+52.97 "A" P.I. = 46+69.38 "A" Line "PR-A"THE MEADOWS ATTHE LEGACY18" plastic Constr. Limits 36" conc. water lines Indianapolis Water Company Easement VariesBEGIN PROJECT 44+79.00 "PR-A" Exist. 50' R/W Constr. Limits N47°01'38"E "A"N47°13'52"E "A"N46°58'46"E "A" Str. No. 15 Str. No. 18 Str. No. 19 Str. No. 12 Str. No. 11 Str. No. 13 Str. No. 16Str. No. 14 Str. No. 10 Str.No. 17 Proposed Path/Drainage Easement All R/W and Topo from Line "A" LEGEND EXISTING Storm Manhole Gas Line Storm Inlets Sanitary Manhole Gas ValveGas Meter Sanitary Cleanout Water Line Water ValveFire Hydrant Sprinkler Electric Line Power Pole w/(Riser)Light & Power Pole Light & Power Pole w/Riser Water Meter Light PoleGuy Wire Electric Box Fiber Optic LineTelephone Line Telephone ManholeCable TV LineCable TV Box Telephone Riser Utility ManholeWood Fence Iron PinSign Flag PoleBushTree TrunkDeciduous TreeConiferous Tree Overhead Utility Line Wood Fence Wire FenceChainlink FenceIron FenceIrr. Valve Mailbox ORIGINATING BENCHMARK About 1 mile SE along St. Highway 238 from the 3rd Ward Grammar School and the junction of St. Highway 237 at Noblesville, about 0.5 mile NW of the junction of a black top road S, 0.35 mile SE of the steel bridge over Stoney Creek, set in the center of the top of the NE concrete head wall on a 12" pipe culvert, 14.8 ft NE of the center line of the highway, 40.19 ft 180 degree azimuth from utility pole #183-915, 53.31 ft 200 degree azimuth from SE corner of vinyl sided addition to house at address #21.30, 12.17 ft 175 degree azimuth from SE face of utility pole # 059-288. NGS Bench Mark Disk stamped Q 237 1947, Designation - Q 237 PID - LA1580, Vertical Order - Second Class II Elevation = 778.52 (NAVD 88) TBM #400 - RR spike up ±1.0' in N face of PWP #055335 Sta. 81+35.29 "A", 61.66' Lt., Elev. = 761.10 TBM #402 - Chiseled "X" on N bonnet bolt of Fire Hyd. at SW corner of River Rd. and Buckskin Ct. Sta. 19+15.40 "A", 64.15' Lt., Elev. = 756.91 TBM #403 - RR spike up ±1.0' in NW face of PWP #HMI-10320 Sta. 30+95.08 "A", 17.54' Rt., Elev. = 755.24 TBM #404 - RR spike up ±1.0' in W face of PWP #254593 Sta. 43+06.50 "A", 22.44' Rt., Elev. = 754.04 TBM #405 - RR spike up ±1.0' in W face of PWP #254588 Sta. 53+59.40 "A", 26.03' Rt., Elev. = 757.85 TBM #406 - RR spike up ±1.0' in W face of PWP #078375 Sta. 64+52.9 "A", 22.3' Rt., Elev. = 755.90 TBM #407 - RR spike up ±1.0' in S face of PWP #078367 Sta. 74+30.8 "A", 21.5' Rt., Elev. = 760.05 TBM #408 - Painted "X" on NE corner of concrete pedestal for signal pole. Sta. 92+27.81 "A", 55.31' Rt., Elev. = 759.76 CONTROL POINT 116 (MAG NAIL FLUSH) - O.P.O.T. STA. 43+63.47, 35.29' (L) LINE "A" N = 48849.0757 E = 48220.8942 (1) TOP S CORNER OF PEDESTAL FOR ELEC. BOX, 20.80' (2) MAG NAIL SET IS SE FACE OF POWER POLE UP ±2.0', 109.57' (3) TOP CENTER NUT ON FIRE HYDRANT, 81.22' (4) T.B.M #404 - RR SPIKE IN W FACE OF POWER POLE #254593 UP ±1.0', 81.19'LINE "A" RIVER RD. (1) (2)(3) (4)COMMUNITYDRIVEC.P. 116 CONTROL POINT 117 (REBAR WITH CAP) - O.P.O.T. STA. 54+23.78, 27.69' (R) LINE "A" N = 49462.3739 E = 49081.3689 (1) CHISELED MARK UP ±1.0' ON SE EDGE OF SIGN (CURVE AHEAD SYMBOL) , 116.74' (2) NW FACE OF CORNER FENCE POST UP ±1.0', 96.96' (3) MAG NAIL SET IN NW FACE OF PWP #254587 UP ±1.0', 81.22' (4) T.B.M #405 - RR SPIKE IN W FACE OF POWER POLE #254588 UP ±1.0', 64.54' LINE "A" RIVER RD. (1) C.P. 117(2)(3)(4)M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: PP-A.dwgDATE/USER: 1/10/2017 8:40 AM / MmastersonPLAN AND PROFILE LINE "PR-A" 1"=30' 1"=5'MATCH LINE 49+00 "PR-A"750 745 740 735 755 760 8 765 770 775 750 745 740 735 755 760 765 770 775 EARTHWORK SUMMARY COMMON EXCAVATION = 20,616 CYS* USEABLE COMMON = 16,491 CYS FILL = 12,075 CYS FILL +25% = 15,095 CYS WASTE = 7,561 CYS** * - Including 4,125 cys asphalt pavement removal. ** - Includes 2,040 cys undistributed for removal of soft soils. EARTHWORK SUMMARY - ALTERNATE NO. 1 COMMON EXCAVATION = 22,641 CYS* USEABLE COMMON = 18,516 CYS FILL = 10,931 CYS FILL +25% = 13,664 CYS WASTE = 11,017 CYS ** * - Including 4,125 cys asphalt pavement removal. ** - Includes 2,040 cys undistributed for removal of soft soils. +45.0,27.2 Power Pole+51.8,15.6 Sign (Caution)+92.8,96.1 6" Dec.+94.4,89.0 3" Dec.+94.4,93.9 12" Dec.+01.1,84.2 6" Dec.+08.8,99.1 36" Stump+45.1,25.5 Power Pole+58.4,26.1 Power Pole+23.8,27.7 Pin w/Cap Fnd+74.9,25.7 Power Pole+98.7,96.0 48" Dec.+02.3,100.7 48" Dec.+31.9,37.7 3" Dec.+84.8,26.8 3" Dec.+23.1,38.6 3" Dec.+26.3,41.2 3" Dec.+26.6,33.3 3" Dec.+31.2,26.6 3" Dec.+33.6,27.9 3" Dec.+38.9,13.9 Sign (Caution)+48.8,28.5 3" Dec.+52.9,23.7 1" Con.+56.6,26.6 3" Dec.+78.0,31.5 18" Dec.+78.3,34.9 12" Dec.+10.7,55.4 30" Dec.+42.5,88.9 Storm M.H.+47.0,16.8 Power Pole+48.7,47.8 12" Bush+83.0,46.7 24" Bush+16.0,45.7 24" Bush+50.9,46.6 24" Bush+87.6,47.0 24" Bush+24.4,47.2 12" Bush+60.1,47.1 12" Bush+95.5,48.0 36" Bush+29.8,49.9 24" Bush+65.0,49.4 12" Bush+00.0,50.3 12" Bush+36.3,50.0 24" Bush+71.8,50.1 24" Bush+06.6,49.0 24" Bush+41.4,50.1 24" Bush50+0051+0052+0053+0054+0055+0056+00+38.1,110.6 Storm M.H.(riprap) 18" plastic App. Exist. 45' R/W Sec. 23, T18N, R4E Clay Township Hamilton County Connor Prairie Foundation Inc. Sec. 23, T18N, R4E Clay Township Hamilton County Falcon Nest II LLC THE O V E R L O O K AT TH E L E G A C Y RIVER RD. Line "A" T.B.M. 405 C.P. 117 P.I./P.C. = 49+27.06 "A" P.I. = 50+96.96 "A" P.I./P.T. = 52+65.27 "A" P.I. = 54+70.47 "A" CURVE DATA PI = 50+96.96 "A" Delta = 13°34'42" Rt. R = 1427.14 ft T = 169.90 ft L = 338.21 ft E = 10.08 ft Line "PR-A" Exist. 50' R/W 18" plastic CURVE DATA PI = 50+76.78 "PR-A" Delta = 12°27'19" Rt. R = 1427.15 ft T = 155.74 ft L = 310.25 ft E = 8.47 ft P.I. = 50+76.78 "PR-A" P.T. = 52+31.29 "PR-A" P.C. = 49+21.04 "PR-A" Constr. Limits Constr. Limits N59°30'06"E "PR-A" N47°02'47" E " P R - A " N47°15'49" E " A " N60°50'31"E "A"N59°08'15"E "A"N59°26'13"E "A" Str. No. 21 Str. No. 22 Str. No. 18 Str. No. 19 Str.No. 20 Str.No. 23 Str.No. 24 Proposed Path/Drainage Easement All R/W and Topo from Line "A" LEGEND EXISTING Storm Manhole Gas Line Storm Inlets Sanitary Manhole Gas ValveGas Meter Sanitary Cleanout Water Line Water ValveFire Hydrant Sprinkler Electric Line Power Pole w/(Riser)Light & Power Pole Light & Power Pole w/Riser Water Meter Light PoleGuy Wire Electric Box Fiber Optic LineTelephone Line Telephone ManholeCable TV LineCable TV Box Telephone Riser Utility ManholeWood Fence Iron PinSign Flag PoleBushTree TrunkDeciduous TreeConiferous Tree Overhead Utility Line Wood Fence Wire FenceChainlink FenceIron FenceIrr. Valve Mailbox ORIGINATING BENCHMARK About 1 mile SE along St. Highway 238 from the 3rd Ward Grammar School and the junction of St. Highway 237 at Noblesville, about 0.5 mile NW of the junction of a black top road S, 0.35 mile SE of the steel bridge over Stoney Creek, set in the center of the top of the NE concrete head wall on a 12" pipe culvert, 14.8 ft NE of the center line of the highway, 40.19 ft 180 degree azimuth from utility pole #183-915, 53.31 ft 200 degree azimuth from SE corner of vinyl sided addition to house at address #21.30, 12.17 ft 175 degree azimuth from SE face of utility pole # 059-288. NGS Bench Mark Disk stamped Q 237 1947, Designation - Q 237 PID - LA1580, Vertical Order - Second Class II Elevation = 778.52 (NAVD 88) TBM #400 - RR spike up ±1.0' in N face of PWP #055335 Sta. 81+35.29 "A", 61.66' Lt., Elev. = 761.10 TBM #402 - Chiseled "X" on N bonnet bolt of Fire Hyd. at SW corner of River Rd. and Buckskin Ct. Sta. 19+15.40 "A", 64.15' Lt., Elev. = 756.91 TBM #403 - RR spike up ±1.0' in NW face of PWP #HMI-10320 Sta. 30+95.08 "A", 17.54' Rt., Elev. = 755.24 TBM #404 - RR spike up ±1.0' in W face of PWP #254593 Sta. 43+06.50 "A", 22.44' Rt., Elev. = 754.04 TBM #405 - RR spike up ±1.0' in W face of PWP #254588 Sta. 53+59.40 "A", 26.03' Rt., Elev. = 757.85 TBM #406 - RR spike up ±1.0' in W face of PWP #078375 Sta. 64+52.9 "A", 22.3' Rt., Elev. = 755.90 TBM #407 - RR spike up ±1.0' in S face of PWP #078367 Sta. 74+30.8 "A", 21.5' Rt., Elev. = 760.05 TBM #408 - Painted "X" on NE corner of concrete pedestal for signal pole. Sta. 92+27.81 "A", 55.31' Rt., Elev. = 759.76 CONTROL POINT 116 (MAG NAIL FLUSH) - O.P.O.T. STA. 43+63.47, 35.29' (L) LINE "A" N = 48849.0757 E = 48220.8942 (1) TOP S CORNER OF PEDESTAL FOR ELEC. BOX, 20.80' (2) MAG NAIL SET IS SE FACE OF POWER POLE UP ±2.0', 109.57' (3) TOP CENTER NUT ON FIRE HYDRANT, 81.22' (4) T.B.M #404 - RR SPIKE IN W FACE OF POWER POLE #254593 UP ±1.0', 81.19'LINE "A" RIVER RD. (1) (2)(3) (4)COMMUNITYDRIVEC.P. 116 CONTROL POINT 117 (REBAR WITH CAP) - O.P.O.T. STA. 54+23.78, 27.69' (R) LINE "A" N = 49462.3739 E = 49081.3689 (1) CHISELED MARK UP ±1.0' ON SE EDGE OF SIGN (CURVE AHEAD SYMBOL) , 116.74' (2) NW FACE OF CORNER FENCE POST UP ±1.0', 96.96' (3) MAG NAIL SET IN NW FACE OF PWP #254587 UP ±1.0', 81.22' (4) T.B.M #405 - RR SPIKE IN W FACE OF POWER POLE #254588 UP ±1.0', 64.54' LINE "A" RIVER RD. (1) C.P. 117(2)(3)(4) 49+00 50+00 51+00 52+00 53+00 54+00 55+00 56+00 Existing Profile @ Line "PR-A" Proposed Profile @ Line "PR-A"749.70749.83750.11750.56751.04751.52752.04752.59753.08753.50753.94754.39754.86755.34755.77756.13756.34756.54756.68756.81756.86756.88756.92756.96757.08757.25757.37757.40757.43757.47750.69752.29753.89755.49757.09758.16758.17757.65751.09751.49751.89752.69753.09753.49754.29754.69755.09755.89756.29756.69757.46757.76757.99758.26758.30758.27758.04757.91757.78757.52+1.60% PVI STA: 54+00 PVI EL: 758.69 VCL: 200.00 -0.52% Grade of Special "V" Ditch Right (Plotted 10' Below Datum)+25 752.17 +00 754.97 +25756.77+1.60% +0.80%-0.40% -2.40%+2.40%+0.00%+4.90%-4.90 % -0.00% PVI STA: 51+00 PVI EL: 747.40 VCL: 20.00 PVI STA: 49+75 PVI EL: 746.18 VCL: 20.00 PVI STA: 49+25 PVI EL: 746.18 VCL: 20.00 PVI STA: 51+25 PVI EL: 746.18 VCL: 20.00 PVI STA: 50+75 PVI EL: 746.18 VCL: 20.00 PVI STA: 49+50 PVI EL: 745.58 VCL: 20.00 Grade of Path Lt. (Plotted 20' Above Datum) M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: PP-A.dwgDATE/USER: 1/10/2017 8:40 AM / MmastersonPLAN AND PROFILE LINE "PR-A" 1"=30' 1"=5'MATCH LINE 56+50 "PR-A"9MATCH LINE 49+00 "PR-A"750 745 740 735 755 760 765 770 775 750 745 740 735 755 760 765 770 775 +94.8,25.4 Power Pole+28.8,40.7 Water Valve+14.6,25.0 PP w/Riser+39.9,92.5 Power Pole+95.3,15.2 Sign (35 MPH)+28.9,19.4 PP w/Riser+75.9,50.5 24" Bush+11.5,49.6 24" Bush+46.4,50.6 24" Bush+80.4,50.3 24" Bush+14.9,50.3 24" Bush+50.1,50.4 24" Bush+85.0,54.7 24" Bush+19.1,59.0 12" Bush+53.9,62.8 24" Bush+89.2,66.5 12" Bush+25.6,71.2 24" Bush+18.0,83.5 36" Dec.+93.1,31.7 Power Pole+22.3,50.8 Post+28.1,54.1 Post57+0058+0059+0060+0061+0062+0063+00(conc) (grvl) App. Exist. 45' R/W App. PLSec. 23, T18N, R4E Clay Township Hamilton County Connor Prairie Foundation Inc. Sec. 23, T18N, R4E Clay Township Hamilton County Falcon Nest II LLC Falcon Nest II LLC THE O V E R L O O K AT TH E L E G A C Y RIVER RD. P.I. = 56+81.42 "A" P.I. = 60+98.28 "A" P.I. = 63+12.02 "A" Line "PR-A" Line "A"R/W R/W R/WConstr. Limits Constr. Limits 10" p v c Exist. 50' R/W P.O.T. 57+81.39 "PR-A" = P.C. 57+81.39 "PR-A1" P.T. = 59+55.79 "PR-A1" Constr. Limits P.I. = 58+68.94 "PR-A1" CURVE DATA PI = 58+68.94 "PR-A1" Delta = 12°29'26" Lt. R = 800.00 ft T = 87.55 ft L = 174.40 ft E = 4.78 ft Line "PR-A2" Line "PR-A1" Line "B"0+001+002+003+00 P.O.T. 3+18.87 "B" = P.O.T. 61+51.55 "PR-A" N59°30'06"E "PR-A" N47°00'40" E N63°04'33"E N63°04'33"E "PR-A2"N59°38'43"E "A" N59°38'13"E "A" N58°29'55"E "A" N58°29'55"E "A" Str. No. 28 Str. No. 25 Str. No. 26 Str. No. 32 Str. No. 30 Str. No. 27 Str. No. 29 Str. No. 31 Proposed Path/Drainage Easement R/W App. PL Proposed Path/Drainage Easem e n t Str. No. 32A Str. No. 32B Str. No. 32C All R/W and Topo from Line "A" LEGEND EXISTING Storm Manhole Gas Line Storm Inlets Sanitary Manhole Gas ValveGas Meter Sanitary Cleanout Water Line Water ValveFire Hydrant Sprinkler Electric Line Power Pole w/(Riser)Light & Power Pole Light & Power Pole w/Riser Water Meter Light PoleGuy Wire Electric Box Fiber Optic LineTelephone Line Telephone ManholeCable TV LineCable TV Box Telephone Riser Utility ManholeWood Fence Iron PinSign Flag PoleBushTree TrunkDeciduous TreeConiferous Tree Overhead Utility Line Wood Fence Wire FenceChainlink FenceIron FenceIrr. Valve Mailbox ORIGINATING BENCHMARK About 1 mile SE along St. Highway 238 from the 3rd Ward Grammar School and the junction of St. Highway 237 at Noblesville, about 0.5 mile NW of the junction of a black top road S, 0.35 mile SE of the steel bridge over Stoney Creek, set in the center of the top of the NE concrete head wall on a 12" pipe culvert, 14.8 ft NE of the center line of the highway, 40.19 ft 180 degree azimuth from utility pole #183-915, 53.31 ft 200 degree azimuth from SE corner of vinyl sided addition to house at address #21.30, 12.17 ft 175 degree azimuth from SE face of utility pole # 059-288. NGS Bench Mark Disk stamped Q 237 1947, Designation - Q 237 PID - LA1580, Vertical Order - Second Class II Elevation = 778.52 (NAVD 88) TBM #400 - RR spike up ±1.0' in N face of PWP #055335 Sta. 81+35.29 "A", 61.66' Lt., Elev. = 761.10 TBM #402 - Chiseled "X" on N bonnet bolt of Fire Hyd. at SW corner of River Rd. and Buckskin Ct. Sta. 19+15.40 "A", 64.15' Lt., Elev. = 756.91 TBM #403 - RR spike up ±1.0' in NW face of PWP #HMI-10320 Sta. 30+95.08 "A", 17.54' Rt., Elev. = 755.24 TBM #404 - RR spike up ±1.0' in W face of PWP #254593 Sta. 43+06.50 "A", 22.44' Rt., Elev. = 754.04 TBM #405 - RR spike up ±1.0' in W face of PWP #254588 Sta. 53+59.40 "A", 26.03' Rt., Elev. = 757.85 TBM #406 - RR spike up ±1.0' in W face of PWP #078375 Sta. 64+52.9 "A", 22.3' Rt., Elev. = 755.90 TBM #407 - RR spike up ±1.0' in S face of PWP #078367 Sta. 74+30.8 "A", 21.5' Rt., Elev. = 760.05 TBM #408 - Painted "X" on NE corner of concrete pedestal for signal pole. Sta. 92+27.81 "A", 55.31' Rt., Elev. = 759.76 CONTROL POINT 117 (REBAR WITH CAP) - O.P.O.T. STA. 54+23.78, 27.69' (R) LINE "A" N = 49462.3739 E = 49081.3689 (1) CHISELED MARK UP ±1.0' ON SE EDGE OF SIGN (CURVE AHEAD SYMBOL) , 116.74' (2) NW FACE OF CORNER FENCE POST UP ±1.0', 96.96' (3) MAG NAIL SET IN NW FACE OF PWP #254587 UP ±1.0', 81.22' (4) T.B.M #405 - RR SPIKE IN W FACE OF POWER POLE #254588 UP ±1.0', 64.54' LINE "A" RIVER RD. (1) C.P. 117(2)(3)(4) CONTROL POINT 118 (REBAR WITH CAP) - O.P.O.T. STA. 64+87.80, 32.74' (R) LINE "A" N = 50000.0000 E = 50000.0000 (1) NORTH FACE OF GATE POST UP ±1.0', 169.49' (2)MAG NAIL IN SOUTH CORNER OF WOOD FENCE POST UP ±1.0' 163.20' (3) MAG NAIL IN N FACE OF PWP #078376 UP ±3.0', 179.42' (4) T.B.M #406 - RR SPIKE IN W FACE OF POWER POLE #078375 UP ±1.0', 37.45' LINE "A" RIVER RD. (2) C.P. 118(1)(3)(4) 57+00 58+00 59+00 60+00 61+00 62+00 63+00 64+00 Existing Profile @ Line "PR-A" Proposed Profile @ Line "PR-A" & "PR-A1"757.50757.42757.36757.39757.37757.18757.00756.95756.90757.09757.33757.52757.69757.82757.82757.82757.85757.89757.75757.60757.40757.20757.01756.82756.59756.23755.86755.57755.32755.12757.13756.61756.09755.57755.32757.39757.26757.00756.87756.74756.48756.35756.22755.96755.83755.70755.44755.32755.27-0.52% +0.52% PVI STA: 60+75 PVI EL: 755.18 VCL: 70.00 +0.52% 61+23.26755.43 62+53.14755.59-1.86%755.18754.72754.31753.95753.66Proposed Profile @ Line "PR-A2" & "PR-A" Grade of Special "V" Ditch Right (Plotted 10' Below Datum) +50 753.27+00755.27-0.80% +4.82% -4.94 %+4.94% PVI STA: 58+50 PVI EL: 748.65 VCL: 20.00 PVI STA: 59+00 PVI EL: 746.18 VCL: 20.00 PVI STA: 58+00 PVI EL: 746.18 VCL: 20.00 +86 755.14 Grade of Path Lt. (Plotted 20' Above Datum) 24" Pipe @ 0.24% 24" Pipe @ 0.42% Inv.=746.00 Str. No. 30 Inv. In=746.53 Inv. In=750.27 Inv. Out=746.53 Str. No. 32 Inv. In=747.52 Inv. Out=747.52 24" Pipe @ 0.42% +00 753.19 -0.40% Grade of Special "V" Ditch Right (Plotted 10' Below Datum) Str. No. 32A Inv. In=747.13 Inv. Out=747.13 Inv. Out=747.65 24" Pipe @ 0.41% Str. No. 32B Inv. In=747.09 Inv. In=747.63 Inv. Out=747.09 M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: PP-A.dwgDATE/USER: 1/10/2017 8:40 AM / MmastersonPLAN AND PROFILE LINE "PR-A" 1"=30' 1"=5'MATCH LINE 64+00 "PR-A"10MATCH LINE 56+50 "PR-A"750 745 740 735 755 760 765 770 775 750 745 740 735 755 760 765 770 775 +52.9,22.7 Power Pole+71.3,23.8 Guy Wire+76.2,23.5 Guy Wire+87.8,32.7 Pin w/Cap Fnd+64.8,35.3 Power Pole+00.9,17.8 Sign+07.4,61.1 Guy Wire+12.2,59.2 Guy Wire+17.5,56.6 Guy Wire+18.9,55.9 Guy Wire+31.9,49.2 Power Pole+85.0,25.0 Sign+11.2,25.9 Water Valve+13.4,36.0 Water Meter+14.2,30.1 Water Valve+20.8,45.8 Water Valve+22.2,30.1 Water Valve+51.3,22.2 Power Pole65+0066+0067+0068+0069+0070+00(grvl) Falcon Nest II LLC Sec. 23, T18N, R4E Clay Township Hamilton County Sec. 23, T18N, R4E Clay Township Hamilton County Connor Prairie Foundation Inc. RIVER RD. Line " P R - A " C.P. 118 T.B.M. 406 P.I. = 65+16.24 "A" P.I. = 66+01.08 "A" P.I./P.C. = 66+65.51 "A" P.I. = 67+62.90 "A" P.I./P.T. = 68+56.53 "A" P.I. = 69+08.40 "A" P.I. = 70+08.16 "A" CURVE DATA PI = 67+62.90 "A" Delta = 27°32'21" Lt. R = 397.42 ft T = 97.39 ft L = 191.02 ft E = 11.76 ft Line " A " Line "PR - A " Line "A" Exist. 50' R/W 50' R/W R/W P.I. = 67+30.66 "PR-A" CURVE DATA PI = 67+30.66 "PR-A" Delta = 37°39'59" Lt. R = 550.00 ft T = 187.59 ft L = 361.57 ft E = 31.11 ft 10" pvc 10" pvc 10 " p v c P.C. 65+43.07 "PR-A" = P.O.C. 65+43.07 "PR-A2" P.C. = 65+08.76 "PR-A2" P.T. = 69+04.64 "PR-A"+71.8,59.2 San. M.H.+04.1,55.1 San. M.H.Constr. Limits Constr. Limits Line " P R - A 2 " P.I. = 65+25.92 "PR-A2" CURVE DATA PI = 65+25.92 "PR-A2" Delta = 3°34'27" Lt. R = 550.00 ft T = 17.16 ft L = 34.31 ft E = 0.27 ft Line " P R - A 2 " N59° 3 0 ' 0 6 " E " P R - A " N21°50' 0 7 " E " P R - A " N63 ° 0 4 ' 3 3 " E N63 ° 0 4 ' 3 3 " E " P R - A 2 " N58° 2 9 ' 5 5 " E " A " N56°4 8 ' 5 8 " E " A " N52°56' 1 9 " E " A " N51°28'3 7 " E " A " N23°56'1 6 " E " A " N24°29'4 6 " E " A " N23°01'4 0 " E " A " N21°20' 0 3 " E " A " N21°20' 0 3 " E " A " N58° 2 9 ' 5 5 " E " A " Str. No. 47 Str. No. 49 Str. No. 50 Str. No. 46 Str. No. 48 Str. No. 45 Str. No. 42 Str. No. 43 Str. No. 41 Str. No. 36 Str. No. 37 Str. No. 38 Str. No. 35 Str. No. 33 Str. No. 39 Str. No. 40 Str. No. 44 R/W Propose d P a t h / D r a i n a g e E a s e m e n t Str. No. 42A R/WApp. PL App. PL All R/W and Topo from Line "A" LEGEND EXISTING Storm Manhole Gas Line Storm Inlets Sanitary Manhole Gas ValveGas Meter Sanitary Cleanout Water Line Water ValveFire Hydrant Sprinkler Electric Line Power Pole w/(Riser)Light & Power Pole Light & Power Pole w/Riser Water Meter Light PoleGuy Wire Electric Box Fiber Optic LineTelephone Line Telephone ManholeCable TV LineCable TV Box Telephone Riser Utility ManholeWood Fence Iron PinSign Flag PoleBushTree TrunkDeciduous TreeConiferous Tree Overhead Utility Line Wood Fence Wire FenceChainlink FenceIron FenceIrr. Valve Mailbox ORIGINATING BENCHMARK About 1 mile SE along St. Highway 238 from the 3rd Ward Grammar School and the junction of St. Highway 237 at Noblesville, about 0.5 mile NW of the junction of a black top road S, 0.35 mile SE of the steel bridge over Stoney Creek, set in the center of the top of the NE concrete head wall on a 12" pipe culvert, 14.8 ft NE of the center line of the highway, 40.19 ft 180 degree azimuth from utility pole #183-915, 53.31 ft 200 degree azimuth from SE corner of vinyl sided addition to house at address #21.30, 12.17 ft 175 degree azimuth from SE face of utility pole # 059-288. NGS Bench Mark Disk stamped Q 237 1947, Designation - Q 237 PID - LA1580, Vertical Order - Second Class II Elevation = 778.52 (NAVD 88) TBM #400 - RR spike up ±1.0' in N face of PWP #055335 Sta. 81+35.29 "A", 61.66' Lt., Elev. = 761.10 TBM #402 - Chiseled "X" on N bonnet bolt of Fire Hyd. at SW corner of River Rd. and Buckskin Ct. Sta. 19+15.40 "A", 64.15' Lt., Elev. = 756.91 TBM #403 - RR spike up ±1.0' in NW face of PWP #HMI-10320 Sta. 30+95.08 "A", 17.54' Rt., Elev. = 755.24 TBM #404 - RR spike up ±1.0' in W face of PWP #254593 Sta. 43+06.50 "A", 22.44' Rt., Elev. = 754.04 TBM #405 - RR spike up ±1.0' in W face of PWP #254588 Sta. 53+59.40 "A", 26.03' Rt., Elev. = 757.85 TBM #406 - RR spike up ±1.0' in W face of PWP #078375 Sta. 64+52.9 "A", 22.3' Rt., Elev. = 755.90 TBM #407 - RR spike up ±1.0' in S face of PWP #078367 Sta. 74+30.8 "A", 21.5' Rt., Elev. = 760.05 TBM #408 - Painted "X" on NE corner of concrete pedestal for signal pole. Sta. 92+27.81 "A", 55.31' Rt., Elev. = 759.76 CONTROL POINT 118 (REBAR WITH CAP) - O.P.O.T. STA. 64+87.80, 32.74' (R) LINE "A" N = 50000.0000 E = 50000.0000 (1) NORTH FACE OF GATE POST UP ±1.0', 169.49' (2)MAG NAIL IN SOUTH CORNER OF WOOD FENCE POST UP ±1.0' 163.20' (3) MAG NAIL IN N FACE OF PWP #078376 UP ±3.0', 179.42' (4) T.B.M #406 - RR SPIKE IN W FACE OF POWER POLE #078375 UP ±1.0', 37.45' LINE "A" RIVER RD. (2) C.P. 118(1)(3)(4) CONTROL POINT 105 (MAG NAIL) - O.P.O.T. STA. 72+90.79, 9.82' (R) LINE "A" N = 50676.5034 E = 50417.5930 (1) NW CORNER OF CONCRETE PILLAR UP ±2.0', 40.94' (2) SW CORNER OF R/W MARKER AT BASE', 183.50' (3) MAG NAIL IN E FACE OF POWER POLE, 148.34' (4) T.B.M #407 - RR SPIKE IN S FACE OF POWER POLE #078367 UP ±1.0', 138.77' LINE "A" RIVER RD. (2) C.P. 105 (1)(3) (4) 64+00 65+00 66+00 67+00 68+00 69+00 70+00 71+00 Proposed Profile @ Line "PR-A" & "PR-A2" Existing Profile @ Line "PR-A"755.12754.97754.78754.49754.20753.88753.54753.24753.00753.26753.42753.76754.12754.53754.98755.43756.06756.59757.07757.49757.82758.07758.31758.56758.76758.84758.86758.86758.87+2.00% -0.52% PVI STA: 68+50 PVI EL: 758.00 VCL: 200.00 PVI STA: 70+50 PVI EL: 756.96 VCL: 100.00 PVI STA: 65+00 PVI EL: 751.00 VCL: 420.00 753.66753.42753.23753.11753.04753.03753.07753.18753.34753.56753.83754.17754.56755.00755.50756.00756.46756.84757.15757.37757.52757.58757.57757.48757.35757.22757.12757.09757.12757.22-1.86% +2.00% -0.52%+0.52% +0.40% +7.04% +0.80%-0.60%+50751.46+50 751.86 +00 755.38 +00 756.18 +50 755.28 +75 755.00 +50 755.69 +0.92% +0.30% Grade of Special "V" Ditch Left (Plotted 20' Above Datum) Grade of Special "V" Ditch Right (Plotted 10' Below Datum) +0.92% +0.40% +7.04% +0.80%-0.60%+1.20% 24" Pipe @ 0.42% 21" Pipe @ 0.50% 21" Pipe @ 0.40%15" Pipe @ 0.50% Str. No. 36 Inv. In=749.34 Inv. In=748.60 Inv. In=748.44 Inv. Out=748.44 Str. No. 42 Inv. In=750.17 Inv. In=750.43 Inv. In=750.42 Inv. Out=750.17 Str. No. 47 Inv. In=752.00 Inv. In=752.63 Inv. In=752.68 Inv. Out=751.75 Pipe @ 0.42% -0.40% +10 752.35Grade of Special "V" Ditch Right (Plotted 10' Below Datum) Grade of Special "V" Ditch Right +0.92% +0.30% 21" Pipe @ 0.39% Str. No. 42A Inv. In=750.84 Inv. Out=750.84 +0.92% Scour Stop Mat (See Sheet 20) M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: PP-A.dwgDATE/USER: 1/10/2017 8:40 AM / MmastersonPLAN AND PROFILE LINE "PR-A" 1"=30' 1"=5'MATCH LINE 71+00 "PR-A"11MATCH LINE 64+00 "PR-A"750 745 740 735 755 760 765 770 775 750 745 740 735 755 760 765 770 775 +52.8,52.3 15" Dec.+80.5,98.3 3" Dec.+84.8,18.7 Power Pole+90.8,9.8 Mag Nail Fnd+45.5,13.7 Sign+99.8,73.1 24" Dec.+00.7,76.1 Post+04.3,15.8 R/W Marker+30.7,21.6 Power Pole+46.2,18.3 Gas Marker+66.3,65.0 R/W Marker+56.1,53.8 PP w/Riser+58.1,83.8 Power Pole+59.9,65.9 R/W Marker+61.0,0.4 Pin Fnd+71.6,24.5 Sign (40 MPH)+98.5,80.4 24" Dec.+04.0,88.4 36" Dec.+08.3,73.3 24" Dec.+76.3,67.7 24" Dec.+31.6,99.5 24" Dec.+74.5,71.8 Gas Vavle+74.9,71.5 Gas Marker+90.0,92.7 60" Dec.+06.0,61.0 Power Pole+67.5,100.3 36" Dec.+72.5,100 36" Dec.+89.8,27.7 18" Dec.+95.2,26.7 30" Dec.+62.9,14.9 Sign+36.8,20.9 Power Pole+37.3,32.6 Guy Wire+69.2,0.4 Pin Fnd+72.5,65.9 R/W Marker78+43.3,10.7 Pin Fnd72+0073+0074+0075+0076+0077+0078+00+60.4,19.7 Pillar(conc) (grvl) (conc) (asph)(asph) (asph) (grvl) 18" rcp 18" rcp App. Exist. R/WApp. PLApp. PL+95,29 Underdrain OutletSec. 23, T18N, R4E Clay Township Hamilton County Connor Prairie Foundation Inc. Falcon Nest II LLC Sec. 23, T18N, R4E Clay Township Hamilton County App. Exist. R/W Harvest Bible Chapel of North Indianapolis Inc. Connor Prairie Foundation Inc. RIVER RD. C.P. 105 T.B.M. 407 P.I. = 71+59.90 "A" P.I. = 74+03.47 "A"P.I. = 74+69.12 "A" P.I. = 78+43.09 "A" P.C. = 76+60.62 "A" CURVE DATA PI = 78+43.09 "A" Delta = 13°47'14" Rt. R = 1509.18 ft T = 182.46 ft L = 363.16 ft E = 10.99 ft Line "PR-A" Line "A"Line "PR-A" Line "A" Exist. 50' R/W R/W CURVE DATA PI = 77+84.50 "PR-A" Delta = 13°44'20" Rt. R = 1000.00 ft T = 120.47 ft L = 239.79 ft E = 7.23 ft P.I. = 77+84.50 "PR-A" 10" pvc P.C. = 76+64.03 "PR-A"+29.4,58.7 San. M.H.+29.4,58.7 San. M.H.+71.6,71.0 San. M.H.8" pvc 8" pvc Constr. Limits Constr. Limits N21°50'07"E "PR-A"N35°34' 2 8 " E " P R - A " N21°14'47"E "A"N21°14'28"E "A" N21°48'16"E "A" N21°20'03"E "A" Str. No. 58 Str. No. 59 Str. No. 53 Str. No. 52 Str. No. 54 Str. No. 55 Str. No. 51 Str. No. 56 50' R/W to be DedicatedApp. PL Str. No. 61 Str. No. 57 All R/W and Topo from Line "A" LEGEND EXISTING Storm Manhole Gas Line Storm Inlets Sanitary Manhole Gas ValveGas Meter Sanitary Cleanout Water Line Water ValveFire Hydrant Sprinkler Electric Line Power Pole w/(Riser)Light & Power Pole Light & Power Pole w/Riser Water Meter Light PoleGuy Wire Electric Box Fiber Optic LineTelephone Line Telephone ManholeCable TV LineCable TV Box Telephone Riser Utility ManholeWood Fence Iron PinSign Flag PoleBushTree TrunkDeciduous TreeConiferous Tree Overhead Utility Line Wood Fence Wire FenceChainlink FenceIron FenceIrr. Valve Mailbox ORIGINATING BENCHMARK About 1 mile SE along St. Highway 238 from the 3rd Ward Grammar School and the junction of St. Highway 237 at Noblesville, about 0.5 mile NW of the junction of a black top road S, 0.35 mile SE of the steel bridge over Stoney Creek, set in the center of the top of the NE concrete head wall on a 12" pipe culvert, 14.8 ft NE of the center line of the highway, 40.19 ft 180 degree azimuth from utility pole #183-915, 53.31 ft 200 degree azimuth from SE corner of vinyl sided addition to house at address #21.30, 12.17 ft 175 degree azimuth from SE face of utility pole # 059-288. NGS Bench Mark Disk stamped Q 237 1947, Designation - Q 237 PID - LA1580, Vertical Order - Second Class II Elevation = 778.52 (NAVD 88) TBM #400 - RR spike up ±1.0' in N face of PWP #055335 Sta. 81+35.29 "A", 61.66' Lt., Elev. = 761.10 TBM #402 - Chiseled "X" on N bonnet bolt of Fire Hyd. at SW corner of River Rd. and Buckskin Ct. Sta. 19+15.40 "A", 64.15' Lt., Elev. = 756.91 TBM #403 - RR spike up ±1.0' in NW face of PWP #HMI-10320 Sta. 30+95.08 "A", 17.54' Rt., Elev. = 755.24 TBM #404 - RR spike up ±1.0' in W face of PWP #254593 Sta. 43+06.50 "A", 22.44' Rt., Elev. = 754.04 TBM #405 - RR spike up ±1.0' in W face of PWP #254588 Sta. 53+59.40 "A", 26.03' Rt., Elev. = 757.85 TBM #406 - RR spike up ±1.0' in W face of PWP #078375 Sta. 64+52.9 "A", 22.3' Rt., Elev. = 755.90 TBM #407 - RR spike up ±1.0' in S face of PWP #078367 Sta. 74+30.8 "A", 21.5' Rt., Elev. = 760.05 TBM #408 - Painted "X" on NE corner of concrete pedestal for signal pole. Sta. 92+27.81 "A", 55.31' Rt., Elev. = 759.76 CONTROL POINT 105 (MAG NAIL) - O.P.O.T. STA. 72+90.79, 9.82' (R) LINE "A" N = 50676.5034 E = 50417.5930 (1) NW CORNER OF CONCRETE PILLAR UP ±2.0', 40.94' (2) SW CORNER OF R/W MARKER AT BASE', 183.50' (3) MAG NAIL IN E FACE OF POWER POLE, 148.34' (4) T.B.M #407 - RR SPIKE IN S FACE OF POWER POLE #078367 UP ±1.0', 138.77' LINE "A" RIVER RD. (2) C.P. 105 (1)(3) (4) CONTROL POINT 152 (MAG NAIL) - O.P.O.T. STA. 79+74.16, 23.74' (R) LINE "A" N = 51287.8570 E = 50709.6939 (1) N CORNER OF R/W MARKER AT BASE, 63.74' (2) W CORNER OF R/W MARKER AT BASE', 186.09' (3) MAG NAIL IN NW FACE OF POWER POLE #079045 UP ±1.0', 160.43' (4) NW CORNER OF SIGN (CURVE AHEAD SYMBOL) UP ±2.0', 136.83' (5) T.B.M #400 - RR SPIKE IN N FACE OF PWP #055335 UP ±1.0', 138.77' LINE "A" RIVER RD. (2) (1)(3) (4) (5) C.P. 152 71+00 72+00 73+00 74+00 75+00 76+00 77+00 78+00 Proposed Profile @ Line "PR-A" Existing Profile @ Line "PR-A"758.87758.90759.03759.15759.37759.58759.72759.84759.98760.11760.22760.30760.29760.19760.02759.87759.75759.67759.61759.58759.60759.71759.89760.05760.12760.16760.12760.05759.97759.91+0.52%757.22757.35757.48757.61757.74757.87758.00758.13758.26758.39758.52758.65758.78758.91759.04759.17759.30759.43759.56759.69759.82759.95760.08760.21760.34760.47760.60760.73760.86760.99+1.20% -0.40%+60 757.80 +00 756.84 +00 756.74 +75 758.64 +0.40% Grade of Special "V" Ditch Left (Plotted 20' Above Datum) Grade of Special "V" Ditch Right (Plotted 10' Below Datum) +0.30% +0.40%-0.40% -0.40% Str. No. 53 Inv. In=753.84 Inv. In=753.89 Inv. In=753.25 Inv. Out=753.25 15" Pipe @ 0.50% +0.40% -0.36% +45 756.40 Grade of Special "V" Ditch Left (Plotted 20' Above Datum) +2.76%-2.94%+3.73% -3.29% -0.01%+0.02% PVI STA: 76+25 PVI EL: 758.82 VCL: 20.00 PVI STA: 78+50 PVI EL: 758.83 VCL: 20.00 PVI STA: 75+92 PVI EL: 757.91 VCL: 20.00 PVI STA: 76+70 PVI EL: 757.50 VCL: 20.00 PVI STA: 78+15 PVI EL: 757.53 VCL: 20.00 PVI STA: 75+50 PVI EL: 757.92 VCL: 20.00 +00 759.56 Grade of Path Lt. (Plotted 10' Above Datum) Str. No. 56 12" Pipe @ 0.89% 18" Pipe @ 0.36% Str. No. 61 +04 756.19 +38 756.07 +0.30% +0.40% 12" Pipe @ 0.50%Str. No. 57 Inv. In=755.18 Inv. In=755.14 Inv. Out=754.50 M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: PP-A.dwgDATE/USER: 1/10/2017 8:40 AM / MmastersonPLAN AND PROFILE LINE "PR-A" 1"=30' 1"=5'MATCH LINE 78+50 "PR-A"12MATCH LINE 71+00 "PR-A"750 745 740 735 755 760 765 770 775 750 745 740 735 755 760 765 770 775 +31.6,99.5 24" Dec.+74.5,71.8 Gas Vavle+74.9,71.5 Gas Marker+90.0,92.7 60" Dec.+06.0,61.0 Power Pole+38.2,59.8 Cable Box+50.2,94.8 15" Con.+74.2,23.7 Mag Nail Set+10.4,86.1 36" Dec.+23.8,65.6 R/W Marker+24.9,0.1 Pin Fnd+90.7,59.8 Gas Marker+11.6,27.1 Sign (W1-WL)+31.2,61.1 Power Pole+15.1,19.9 Mag Nail Set+48.6,64.8 Power Pole+49.5,73.1 Guy Wire+49.6,74.9 Guy Wire+06.4,35.2 Sq. Inlet+50.4,65.6 R/W Marker+76.7,63.5 Guy Wire+76.9,52.5 Power Pole+77.0,62.8 Guy Wire+10.0,61.9 Power Pole+24.7,23.5 Mailbox+25.1,57.0 Cable Box+33.5,61.7 Power Pole+34.3,78.1 Guy Wire+38.4,65.0 R/W Marker+39.2,24.3 Sign+96.9,65.5 Pin w/Cap Fnd+05.6,30.5 Sq. Inlet+51.0,65.7 R/W Marker+51.5,0.1 Pin Fnd+75.2,28.4 Sign (40 MPH)79+0080+0081+0082+0083+0085+0087+0018" rcp 18" rcp 18" rcp 18" rcp24" rcp (asph) (asph)(asph) (grvl) (grvl) App. Exist. R/W App. Exist . R / W App. Exist. R/W App. Exist. R/W App. Exist. R/W App. Exist. R / WApp. PL84+00+53,28 Underdrain OutletSec. 23, T18N, R4E Clay Township Hamilton County Harvest Bible Chapel of North Indianapolis Inc. Sec. 23, T18N, R4E Clay Township Hamilton County Connor Prairie Foundation Inc. KLC Realty LLC RIVER RD. C.P. 152 T.B.M. 400 P.T. = 80+23.78 "A" P.T. = 84+49.82 "A" Line "PR-A" Line "A"P.T. = 79+03.82 "PR-A" P.C. = 84+37.10 "PR-A" Constr. Limits Constr. Limits N35°34'28"E "PR-A" N35°34'28"E "PR-A" N35°35'30"E "A" N35°35'30"E "A" Str. No. 63 Str. No. 62 Str. No. 65 Str. No. 64 Str. No. 72 Str. No. 68 Str. No. 69Str. No. 67 Str. No. 66 Str. No. 70 Str. No. 71 Str. No. 61A Str. No. 61B Str. No. 63A All R/W and Topo from Line "A" LEGEND EXISTING Storm Manhole Gas Line Storm Inlets Sanitary Manhole Gas ValveGas Meter Sanitary Cleanout Water Line Water ValveFire Hydrant Sprinkler Electric Line Power Pole w/(Riser)Light & Power Pole Light & Power Pole w/Riser Water Meter Light PoleGuy Wire Electric Box Fiber Optic LineTelephone Line Telephone ManholeCable TV LineCable TV Box Telephone Riser Utility ManholeWood Fence Iron PinSign Flag PoleBushTree TrunkDeciduous TreeConiferous Tree Overhead Utility Line Wood Fence Wire FenceChainlink FenceIron FenceIrr. Valve Mailbox ORIGINATING BENCHMARK About 1 mile SE along St. Highway 238 from the 3rd Ward Grammar School and the junction of St. Highway 237 at Noblesville, about 0.5 mile NW of the junction of a black top road S, 0.35 mile SE of the steel bridge over Stoney Creek, set in the center of the top of the NE concrete head wall on a 12" pipe culvert, 14.8 ft NE of the center line of the highway, 40.19 ft 180 degree azimuth from utility pole #183-915, 53.31 ft 200 degree azimuth from SE corner of vinyl sided addition to house at address #21.30, 12.17 ft 175 degree azimuth from SE face of utility pole # 059-288. NGS Bench Mark Disk stamped Q 237 1947, Designation - Q 237 PID - LA1580, Vertical Order - Second Class II Elevation = 778.52 (NAVD 88) TBM #400 - RR spike up ±1.0' in N face of PWP #055335 Sta. 81+35.29 "A", 61.66' Lt., Elev. = 761.10 TBM #402 - Chiseled "X" on N bonnet bolt of Fire Hyd. at SW corner of River Rd. and Buckskin Ct. Sta. 19+15.40 "A", 64.15' Lt., Elev. = 756.91 TBM #403 - RR spike up ±1.0' in NW face of PWP #HMI-10320 Sta. 30+95.08 "A", 17.54' Rt., Elev. = 755.24 TBM #404 - RR spike up ±1.0' in W face of PWP #254593 Sta. 43+06.50 "A", 22.44' Rt., Elev. = 754.04 TBM #405 - RR spike up ±1.0' in W face of PWP #254588 Sta. 53+59.40 "A", 26.03' Rt., Elev. = 757.85 TBM #406 - RR spike up ±1.0' in W face of PWP #078375 Sta. 64+52.9 "A", 22.3' Rt., Elev. = 755.90 TBM #407 - RR spike up ±1.0' in S face of PWP #078367 Sta. 74+30.8 "A", 21.5' Rt., Elev. = 760.05 TBM #408 - Painted "X" on NE corner of concrete pedestal for signal pole. Sta. 92+27.81 "A", 55.31' Rt., Elev. = 759.76 CONTROL POINT 152 (MAG NAIL) - O.P.O.T. STA. 79+74.16, 23.74' (R) LINE "A" N = 51287.8570 E = 50709.6939 (1) N CORNER OF R/W MARKER AT BASE, 63.74' (2) W CORNER OF R/W MARKER AT BASE', 186.09' (3) MAG NAIL IN NW FACE OF POWER POLE #079045 UP ±1.0', 160.43' (4) NW CORNER OF SIGN (CURVE AHEAD SYMBOL) UP ±2.0', 136.83' (5) T.B.M #400 - RR SPIKE IN N FACE OF PWP #055335 UP ±1.0', 138.77' LINE "A" RIVER RD. (2) (1)(3) (4) (5) C.P. 152 CONTROL POINT 153 (PIN WITH CAP) - O.P.O.T. STA. 83+96.89, 65.49' (L) LINE "A" N = 52429.7300 E = 51066.8387 (1) CENTER OF MANHOLE, 18.75' (2) INTERSECTION OF WALK & BACK OF CURB, 16.04' (3) NORTH SIDE OF WALK WHERE CONCRETE & ASPHALT MEET, 160.43' (4) T.B.M #408 - PAINTED "X" IN NE CORNER OF CONCRETE PEDESTAL FOR SIGNAL POLE, 16.10'LINE "A" RIVER RD. (2) (1) (3) (4)146TH ST.C.P. 153 Proposed Profile @ Line "PR-A" Existing Profile @ Line "PR-A"759.84759.71759.53759.44759.36759.25759.18759.11759.10759.09758.93758.79758.66758.57758.51758.46758.44758.43758.45758.47758.59758.78758.94759.08759.26759.44759.63759.79759.90760.07-0.60% PVI STA: 79+00 PVI EL: 761.38 VCL: 100.00 PVI STA: 83+60 PVI EL: 758.62 VCL: 120.00 761.12761.22761.24761.20761.08760.93760.78760.63760.48760.33760.18760.03759.88759.73759.58759.43759.28759.13758.98758.86758.80758.81758.88759.01759.16759.31759.46759.61759.76759.91-0.60%+0.60% +04 755.72 +50 756.29 -0.40% +1.24% +0.78% +04.5 END RECONSTRUCTION, LEFT Transition Cross Slope from -2.0% to -7.0% Left+00-3.05% -0.02%+5.00% +1.14%+0.01%-0.35% +2.36%+0.35% +1.65%-2.10% -2.85%-2.38% PVI STA: 84+10 PVI EL: 759.82 VCL: 20.00 PVI STA: 84+80 PVI EL: 760.61 VCL: 20.00 PVI STA: 82+20 PVI EL: 759.08 VCL: 20.00 PVI STA: 81+05 PVI EL: 759.72 VCL: 20.00 PVI STA: 80+20 PVI EL: 760.05 VCL: 20.00 PVI STA: 81+45 PVI EL: 759.86 VCL: 20.00 PVI STA: 83+80 PVI EL: 758.32 VCL: 20.00 PVI STA: 82+55 PVI EL: 758.34 VCL: 20.00 PVI STA: 81+95 PVI EL: 758.67 VCL: 20.00 PVI STA: 80+65 PVI EL: 758.77 VCL: 20.00 PVI STA: 79+90 PVI EL: 760.16 VCL: 20.00 +77.50 760.54 Grade of Special "V" Ditch Right (Plotted 10' Below Datum) Grade of Path Lt. (Plotted 10' Above Datum)Existing Grade of Path Lt. (Plotted 10' Above Datum) -3.05% -0.02%+5.00% +1.14%-0.35% +2.36%+0.35% +1.65%-2.10% -2.85%-2.38% +1.24% Existing 18" Pipe Inv.=754.58 Str. No. 62 Inv. In=755.62 Inv. In=754.7± Inv. Out=754.7± -0.40% +1.24% +0.78% +57 755.28 +0.50%+1.83% +57 757.82 +85.15 757.96 +00 758.23 Grade of Special "V" Ditch Left (Plotted 20' Above Datum) +4.98% +0.05% PVI STA: 78+85 PVI EL: 758.85 VCL: 20.00 +32.25 761.20 Grade of Path Lt. (Plotted 10' Above Datum) 15" Pipe @ 0.40% Str. No. 61A Inv.=755.28 Str. No. 61B 15" Pipe @ 0.40% -0.40% +1.24% +04 757.72 +74 757.44 +04 757.72 +74 757.44 +34 757.60 +04 757.32 M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: PP-A.dwgDATE/USER: 1/10/2017 8:40 AM / MmastersonPLAN AND PROFILE LINE "PR-A" 1"=30' 1"=5'MATCH LINE 86+00 "PR-A"13MATCH LINE 78+50 "PR-A"79+00 80+00 81+00 82+00 83+00 84+00 85+00 750 745 740 735 755 760 765 770 775 750 745 740 735 755 760 765 770 775 +76.7,63.5 Guy Wire+76.9,52.5 Power Pole+77.0,62.8 Guy Wire+10.2,56.4 Gas Marker+77.0,64.1 Guy Wire+77.3,62.9 Guy Wire+78.2,53.5 Power Pole+84.9,24.8 Mag Nail Set+11.9,65.5 R/W Marker+18.3,0.6 Pin Fnd+76.0,60.8 Power Pole+88.6,62.2 Guy Wire+53.9,31.2 Inlet+72.1,65.2 Gas Vavle+75.2,62.3 R/W Marker+75.2,28.4 Sign (40 MPH)+36.7,47.8 Storm M.H.+20.6,65.6 R/W Marker+71.9,26.5 Sign+81.1,29.9 Storm M.H.91+53.3,29.8 Storm M.H.+53.5,19.7 Inlet87+0088+0089+0090+0091+0092+0024" r c p 24" rc p (grvl)+84.0,22.5 Sign+81.2,83.4 Water Valve+97.8,79.7 R/W Marker+96.1,81.2 Power Pole+25.8,49.8 Signal Pole+11.3,24.5 Storm M.H.+25.3,56.3 Signal PoleApp. Exist. R/W App. Exist. R/W App. E x i s t . R / W App. Exist. R/WApp. Exist. R/WApp. PL+82,32 Underdrain Outlet24" rcp 24" rcp 24" rcp 12" rcp??" rcp??" rcpRIVER RD. Sec. 23, T18N, R4E Clay Township Hamilton County Connor Prairie Foundation Inc. Sec. 23, T18N, R4E Clay Township Hamilton County KLC Realty LLC L & Q Realty LLC C.P. 119 T.B.M. 408 P.I. = 86+91.08 "A" P.T. = 89+16.84 "A" CURVE DATA PI = 86+91.08 "A" Delta = 35°27'36" Lt. R = 754.60 ft T = 241.26 ft L = 467.01 ft E = 37.63 ft Line "PR-A" Line "A" CURVE DATA PI = 86+70.63 "PR-A" Delta = 35°28'47" Lt. R = 730.00 ft T = 233.53 ft L = 452.04 ft E = 36.44 ft P.I. = 86+70.63 "PR-A" END PROJECT 90+55.00 "PR-A" P.T. = 88+89.14 "PR-A" Constr. Limits Constr. Limits N3 5 ° 3 4 ' 2 8 " E " P R - A " N0°05'40"E "PR-A" N0°07'54"E "A" N3 5 ° 3 5 ' 3 0 " E " A " Str. No. 75 Str. No. 77 Str. No. 78 Str. No. 73 Str. No. 74 Str. No. 76 All R/W and Topo from Line "A" LEGEND EXISTING Storm Manhole Gas Line Storm Inlets Sanitary Manhole Gas ValveGas Meter Sanitary Cleanout Water Line Water ValveFire Hydrant Sprinkler Electric Line Power Pole w/(Riser)Light & Power Pole Light & Power Pole w/Riser Water Meter Light PoleGuy Wire Electric Box Fiber Optic LineTelephone Line Telephone ManholeCable TV LineCable TV Box Telephone Riser Utility ManholeWood Fence Iron PinSign Flag PoleBushTree TrunkDeciduous TreeConiferous Tree Overhead Utility Line Wood Fence Wire FenceChainlink FenceIron FenceIrr. Valve Mailbox ORIGINATING BENCHMARK About 1 mile SE along St. Highway 238 from the 3rd Ward Grammar School and the junction of St. Highway 237 at Noblesville, about 0.5 mile NW of the junction of a black top road S, 0.35 mile SE of the steel bridge over Stoney Creek, set in the center of the top of the NE concrete head wall on a 12" pipe culvert, 14.8 ft NE of the center line of the highway, 40.19 ft 180 degree azimuth from utility pole #183-915, 53.31 ft 200 degree azimuth from SE corner of vinyl sided addition to house at address #21.30, 12.17 ft 175 degree azimuth from SE face of utility pole # 059-288. NGS Bench Mark Disk stamped Q 237 1947, Designation - Q 237 PID - LA1580, Vertical Order - Second Class II Elevation = 778.52 (NAVD 88) TBM #400 - RR spike up ±1.0' in N face of PWP #055335 Sta. 81+35.29 "A", 61.66' Lt., Elev. = 761.10 TBM #402 - Chiseled "X" on N bonnet bolt of Fire Hyd. at SW corner of River Rd. and Buckskin Ct. Sta. 19+15.40 "A", 64.15' Lt., Elev. = 756.91 TBM #403 - RR spike up ±1.0' in NW face of PWP #HMI-10320 Sta. 30+95.08 "A", 17.54' Rt., Elev. = 755.24 TBM #404 - RR spike up ±1.0' in W face of PWP #254593 Sta. 43+06.50 "A", 22.44' Rt., Elev. = 754.04 TBM #405 - RR spike up ±1.0' in W face of PWP #254588 Sta. 53+59.40 "A", 26.03' Rt., Elev. = 757.85 TBM #406 - RR spike up ±1.0' in W face of PWP #078375 Sta. 64+52.9 "A", 22.3' Rt., Elev. = 755.90 TBM #407 - RR spike up ±1.0' in S face of PWP #078367 Sta. 74+30.8 "A", 21.5' Rt., Elev. = 760.05 TBM #408 - Painted "X" on NE corner of concrete pedestal for signal pole. Sta. 92+27.81 "A", 55.31' Rt., Elev. = 759.76 CONTROL POINT 152 (MAG NAIL) - O.P.O.T. STA. 79+74.16, 23.74' (R) LINE "A" N = 51287.8570 E = 50709.6939 (1) N CORNER OF R/W MARKER AT BASE, 63.74' (2) W CORNER OF R/W MARKER AT BASE', 186.09' (3) MAG NAIL IN NW FACE OF POWER POLE #079045 UP ±1.0', 160.43' (4) NW CORNER OF SIGN (CURVE AHEAD SYMBOL) UP ±2.0', 136.83' (5) T.B.M #400 - RR SPIKE IN N FACE OF PWP #055335 UP ±1.0', 138.77' LINE "A" RIVER RD. (2) (1)(3) (4) (5) C.P. 152 CONTROL POINT 153 (PIN WITH CAP) - O.P.O.T. STA. 83+96.89, 65.49' (L) LINE "A" N = 52429.7300 E = 51066.8387 (1) CENTER OF MANHOLE, 18.75' (2) INTERSECTION OF WALK & BACK OF CURB, 16.04' (3) NORTH SIDE OF WALK WHERE CONCRETE & ASPHALT MEET, 160.43' (4) T.B.M #408 - PAINTED "X" IN NE CORNER OF CONCRETE PEDESTAL FOR SIGNAL POLE, 16.10'LINE "A" RIVER RD. (2) (1) (3) (4)146TH ST.C.P. 153 Proposed Profile @ Line "PR-A" Existing Profile @ Line "PR-A"760.21760.38760.49760.60760.69760.72760.75760.72760.69760.62760.54760.33760.16760.00759.80759.62759.34759.09758.84758.58758.40758.24758.28758.31758.45+0.60% -0.87% END PROJECT STA. 90+55.00 ELEV. 759.04 PVI STA: 88+00 PVI EL: 761.26 VCL: 200.00 760.06760.21760.36760.51760.66760.79760.87760.90760.89760.84760.73760.58760.39760.17759.96759.74759.52759.30759.09-0.87% +00 758.24 +50Transition Cross Slope from -2.0% to -7.0% Left Transition Cross Slope from -2.0% to +5.0% Right+06+30-1.95% -4.41% +0.93% PVI STA: 88+20 PVI EL: 761.52 VCL: 20.00 PVI STA: 88+50 PVI EL: 760.94 VCL: 20.00 PVI STA: 87+25 PVI EL: 760.64 VCL: 20.00 +67.52 760.16 Grade of Special "V" Ditch Right (Plotted 10' Below Datum) Grade of Path Lt. (Plotted 10' Above Datum) Existing Grade of Path Lt. (Plotted 10' Above Datum) -1.95% -4.41% +0.01%+0.93% +0.78%+0.78% M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: PP-A.dwgDATE/USER: 1/10/2017 8:40 AM / MmastersonPLAN AND PROFILE LINE "PR-A" 1"=30' 1"=5' 14MATCH LINE 86+00 "PR-A"87+00 88+00 89+00 90+00 91+00 92+00 750 745 740 735 755 760 765 770 775 750 745 740 735 755 760 765 770 775 9+00 10+00 11+00 12+00 13+00 14+00 15+00 16+00751.50751.57751.64751.92751.96751.93752.10752.59753.07753.56754.08754.74755.72756.46752.13752.13752.13752.13752.13752.21752.45752.85753.60754.20+0.00%+1.80%+3.01% +2.00% PVI STA: 12+35.00 PVI ELEV: 752.13 VCL: 70.00 Sta:13+47.37 Elev:754.65 BEGIN CONSTRUCTION STA. 10+87.76 ELEV. 752.13 Proposed Profile @ Line "W-ENT" Existing Profile @ Line "W-ENT" +0.00%+1.13%+2.11% +2.00% PVI STA: 12+35.00 PVI ELEV: 752.08 VCL: 70.00 Proposed Profile @ Line "W-EXIT" (Plotted 20' Above Datum) Sta:13+81.33 Elev:754.73BEGIN CONSTRUCTION STA. 10+86.22 ELEV. 752.08 Exist. 10" pvc 744.93 744.91 +0.40% +2.14% +58 748.40 +00 748.97 +95 751.00 Grade of Special Median Ditch Transition Cross Slopes from +2% to -2%+00+00Transition Cross Slopes from +2% to -2%+00+00PVI STA: 12+75.00 PVI ELEV: 752.53 VCL: 0' PVI STA: 13+40.00 PVI ELEV: 753.90 VCL: 0' PVI STA: 12+75.00 PVI ELEV: 752.85 VCL: 0' PVI STA: 13+10.00 PVI ELEV: 753.90 VCL: 0'10+00(conc)(grvl)App. PL Connor Prairie Foundation Inc. Sec. 23, T18N, R4E Clay Township Hamilton County Falcon Nest II LLC Falcon Nest II LLC RIVER RD.Line "PR-A"50' R/WR/W R/W N59°30'06"E "PR-A"10" pvcP.I. = 11+23.41 "W-ENT" P.I. = 13+18.03 "W-ENT"N90°00'00"ES 0 ° 4 9 ' 1 8 " W S33°53'44"E CURVE DATA PI = 11+23.41 "W-ENT" Delta = 56°06'16" Rt. R = 366.00 ft T = 195.03 ft L = 358.39 ft E = 48.72 ft CURVE DATA PI = 13+18.03 "W-ENT" Delta = 34°43'02" Rt. R = 100.00 ft T = 31.26 ft L = 60.59 ft E = 4.77 ft 10" pvc 10" pvc11+0012+0013+00+18.4, 88.2', 1" Dec.+64.0, 88.1', 1" Dec.+72.7, 88.7', Sign (30 MPH)+86.1, 102.6', Pin w/Cap Fnd+47.3, 10.6',Pin w/Cap Fnd+71.7, 35.4',San. M.H.+72.7, 38.3',Sign (Stop)+48.0, 66.1',Pin w/Cap Fnd+37.8, 79.9',Light Pole+51.6, 81.1',Water Valve+51.0, 89.6',Fire Hyd.+72.5, 90.3',Tele Box+69.8, 90.5',Tele Box+67.3, 91.6',Elec. Box+15.7, 59.6',Sign+15.2, 64.6',Sign+16.9, 71.5',Sign+18.2, 79.5',Fire Hyd.+09.5, 79.7',Water Valve+09.5, 80.3',Water Valve+24.3, 92.8',Gas MarkerLine "W-ENT " P.T. 13+47.36 "W-ENT" = O.P.O.T. 115.48 Lt., 61+65.08 "PR-A" BEGIN CONSTRUCTION 10+87.76 "W-ENT" P.C. = 9+28.38 "W-ENT" P.C.C. = 12+86.77 "W-ENT" BEGIN CONSTRUCTION P.O.C. 10+86.22 "W-EXIT" = O.P.O.C. 68.00 Lt., 10+86.22 "W-ENT" P.T. = 12+36.31 "W-EXIT" P.O.T. = 13+81.33 "W-EXIT"Line "W-EXIT" Constr. Limits Constr. Limits P.I. = 11+63.60 "W-EXIT" CURVE DATA PI = 11+63.60 "W-EXIT" Delta = 34°23'49" Rt. R = 250.00 ft T = 77.38 ft L = 150.08 ft E = 11.70 ft S65°1 7' 3 0 " E S30°53'40"E 0+001+002+00 3+00Line "B" P.O.T. 3+18.87 "B" = P.O.T. 61+51.55 "PR-A" Str. No. 81 Str. No. 82 Str. No. 79 Str. No. 83App. PL R/W App. Exist. R/WApp. Exi s t . R / W App. E xi st. R / W App. Exist. R/ W App. Exist. R/ W App. PL App. Exi s t . R / W Str. No. 80 Str. No. 82A All R/W and Topo from Line "A" LEGEND EXISTING Storm Manhole Gas Line Storm Inlets Sanitary Manhole Gas ValveGas Meter Sanitary Cleanout Water Line Water ValveFire Hydrant Sprinkler Electric Line Power Pole w/(Riser)Light & Power Pole Light & Power Pole w/Riser Water Meter Light PoleGuy Wire Electric Box Fiber Optic LineTelephone Line Telephone ManholeCable TV LineCable TV Box Telephone Riser Utility ManholeWood Fence Iron PinSign Flag PoleBushTree TrunkDeciduous TreeConiferous Tree Overhead Utility Line Wood Fence Wire FenceChainlink FenceIron FenceIrr. Valve Mailbox ORIGINATING BENCHMARK About 1 mile SE along St. Highway 238 from the 3rd Ward Grammar School and the junction of St. Highway 237 at Noblesville, about 0.5 mile NW of the junction of a black top road S, 0.35 mile SE of the steel bridge over Stoney Creek, set in the center of the top of the NE concrete head wall on a 12" pipe culvert, 14.8 ft NE of the center line of the highway, 40.19 ft 180 degree azimuth from utility pole #183-915, 53.31 ft 200 degree azimuth from SE corner of vinyl sided addition to house at address #21.30, 12.17 ft 175 degree azimuth from SE face of utility pole # 059-288. NGS Bench Mark Disk stamped Q 237 1947, Designation - Q 237 PID - LA1580, Vertical Order - Second Class II Elevation = 778.52 (NAVD 88) TBM #400 - RR spike up ±1.0' in N face of PWP #055335 Sta. 81+35.29 "A", 61.66' Lt., Elev. = 761.10 TBM #402 - Chiseled "X" on N bonnet bolt of Fire Hyd. at SW corner of River Rd. and Buckskin Ct. Sta. 19+15.40 "A", 64.15' Lt., Elev. = 756.91 TBM #403 - RR spike up ±1.0' in NW face of PWP #HMI-10320 Sta. 30+95.08 "A", 17.54' Rt., Elev. = 755.24 TBM #404 - RR spike up ±1.0' in W face of PWP #254593 Sta. 43+06.50 "A", 22.44' Rt., Elev. = 754.04 TBM #405 - RR spike up ±1.0' in W face of PWP #254588 Sta. 53+59.40 "A", 26.03' Rt., Elev. = 757.85 TBM #406 - RR spike up ±1.0' in W face of PWP #078375 Sta. 64+52.9 "A", 22.3' Rt., Elev. = 755.90 TBM #407 - RR spike up ±1.0' in S face of PWP #078367 Sta. 74+30.8 "A", 21.5' Rt., Elev. = 760.05 TBM #408 - Painted "X" on NE corner of concrete pedestal for signal pole. Sta. 92+27.81 "A", 55.31' Rt., Elev. = 759.76 CONTROL POINT 117 (REBAR WITH CAP) - O.P.O.T. STA. 54+23.78, 27.69' (R) LINE "A" N = 49462.3739 E = 49081.3689 (1) CHISELED MARK UP ±1.0' ON SE EDGE OF SIGN (CURVE AHEAD SYMBOL) , 116.74' (2) NW FACE OF CORNER FENCE POST UP ±1.0', 96.96' (3) MAG NAIL SET IN NW FACE OF PWP #254587 UP ±1.0', 81.22' (4) T.B.M #405 - RR SPIKE IN W FACE OF POWER POLE #254588 UP ±1.0', 64.54' LINE "A" RIVER RD. (1) C.P. 117(2)(3)(4) CONTROL POINT 118 (REBAR WITH CAP) - O.P.O.T. STA. 64+87.80, 32.74' (R) LINE "A" N = 50000.0000 E = 50000.0000 (1) NORTH FACE OF GATE POST UP ±1.0', 169.49' (2)MAG NAIL IN SOUTH CORNER OF WOOD FENCE POST UP ±1.0' 163.20' (3) MAG NAIL IN N FACE OF PWP #078376 UP ±3.0', 179.42' (4) T.B.M #406 - RR SPIKE IN W FACE OF POWER POLE #078375 UP ±1.0', 37.45' LINE "A" RIVER RD. (2) C.P. 118(1)(3)(4)M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: PP-W-RAB.dwgDATE/USER: 1/9/2017 10:30 AM / TbennettPLAN AND PROFILE LINE "W-ENT" & "W-EXIT" 1"=30' 1"=5' 750 745 740 735 755 760 15 765 770 775 750 745 740 735 755 760 765 770 775 43+0042+0044+0045+0046+00(grvl)(sign)12" rcp12" rcpApp. Exist. R/W App. Exist. R/W A p p . P L COMMUNITY DR.Carmel Clay Schools Connor Prairie Foundation Inc. THE O V E R L O O K AT T H E L E G A C Y Falcon Nest II LLC Falcon Nest II LLC RIVER RD. T.B.M. 404 C.P. 116 Line "PR-A" THE M E A D O W S A T THE L E G A C Y 17'16'10'+6916'K K 18 18 15 15 BEGIN PROJECT 44+79.09 "PR-A" Sec. 23, T18N, R4E Clay Township Hamilton County Sec. 23, T18N, R4E Clay Township Hamilton County 26 Constr. Limits Constr. Limits +86App. Exist. R/WApp. Exist. R/W15 10'16'34'R1 +94 57' +00 42' +69 42' +94.0 Str. No. 12, +92 "PR-A" Inlet Type 'J-10' with 60' of 12" RCP Req'd. Str. No. 11, +92 "PR-A" Inlet Type 'M-10' with 16' of 12" RCP Req'd.R60'P Str. No. 10, +92 "PR-A" 30' Proposed Path/Drainage Easement Indianapolis Water Co. Easement N47°02'47"E "PR-A" App. Exist. R/W+94+96.0 Existing Handhole 44+94 "PR-A" Adjust Valves to Grade PROPOSED LEGEND (See Typical Sheet for Additional Details) Mill and Overlay with WedgeR Curb & Gutter Type II15 Sod26 Full Depth Asphalt PavementK Concrete SidewalkF Perpendicular Curb Ramp Curb & Gutter Type III18 HMA SidewalkP P C PCCP for Approaches, 9" on Subgrade Treatment Type II C2 PCCP, 7" with D-1 Contraction Joints at 15' Max. Spacing on 10" Compacted Aggregate No. 53 Base on Subgrade Treatment Type IB Concrete Curb14 Modified Roll Curb16 Mill and OverlayR1 Mulched Seeding, U27 M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CONSTRUCTION DETAILS.dwgDATE/USER: 1/9/2017 2:22 PM / TbennettCONSTRUCTION DETAILS LINE "PR-A" 1"=20' MATCH LINE 47+00 "PR-A"16 50+0051+0052+0027" Conc.(riprap) (riprap) 18" plastic App. Exist. R / W App. Exist. R/W RIVER RD.12'18" plastic 18" plastic 36" conc. w a t e r l i n e s17'16'CURVE DATA P.I. = 50+76.78 "PR-A" Delta = 12°27'19" Rt. R = 1427.15 ft T = 155.74 ft L = 310.25 ft E = 8.47 ft Normal Crown P.I. = 50+76.78 "PR-A" N47°02'47 " E " P R - A "16'26 15 15 18 K K P.T. = 52+31.29 "PR-A" P.C. = 49+21.04 "PR-A" Constr. Limits Sec. 23, T18N, R4E Clay Township Hamilton County Sec. 23, T18N, R4E Clay Township Hamilton County Connor Prairie Foundation Inc.THE OVERLOOKAT THE LEGACYFalcon Nest II LLC 26 18 15 15 18 18 26 Constr. Limits Constr. Limits 49+0048+0015 P 16'16'+94P 10'+94 34' +00 40' +50 46' +00 46' +50 50' +00 53' +50 55' +50 39' Str. No. 14, +55 "PR-A" Inlet Type 'M-10' with 46' of 12" RCP Req'd. Str. No. 16, +61 "PR-A" Inlet Type 'J-10' with 3' of 12" RCP Req'd. Str. No. 13, +55 "PR-A" Inlet Type 'M-10' with 46' of 12" RCP & 1 Pipe End Section Req'd. Str. No. 15, +61 "PR-A" Inlet Type 'J-10' with 3' of 12" RCP Req'd. Str. No. 18, +00 "PR-A" Inlet Type 'M-10' with 33' of 12" RCP & 1 Pipe End Section Req'd. Str. No. 19, +00 "PR-A" Inlet Type 'J-10' with 44' of 12" RCP Req'd. +50 37' +00 37' Str. No. 22, +00 "PR-A" Inlet Type 'J-10' with 44' of 12" RCP Req'd. Str. No. 21, +00 "PR-A" Inlet Type 'M-10' with 39' of 12" RCP & 1 Pipe End Section Req'd. Str. No. 17, +37 "PR-A" No Work Req'd. Str. No. 23, +42 "PR-A" No Work Req'd. Str. No. 20, +50 "PR-A" 69' of 53"x34" R.C. Elliptical Pipe and 2 Pipe End Sections Req'd. 30' Propos e d P a t h / D r a i n a g e E a s e m e n t 30' Proposed P a t h / D r a i n a g e E a s e m e n t Indianapolis Water C o . E a s e m e n t N59°30'06"E "PR-A" App. Exist. R/W Remove Structure Remove 186 Lft. Guardrail Remove 120 Lft. Guardrail Handhole #1 48+94 "PR-A" 4' x 4' ScourStop Transition Mat 4' x 4' ScourStop Transition Mat 8' x 12' ScourStop Transition Mat 4' x 4' ScourStop Transition Mat PROPOSED LEGEND (See Typical Sheet for Additional Details) Mill and Overlay with WedgeR Curb & Gutter Type II15 Sod26 Full Depth Asphalt PavementK Concrete SidewalkF Perpendicular Curb Ramp Curb & Gutter Type III18 HMA SidewalkP P C PCCP for Approaches, 9" on Subgrade Treatment Type II C2 PCCP, 7" with D-1 Contraction Joints at 15' Max. Spacing on 10" Compacted Aggregate No. 53 Base on Subgrade Treatment Type IB Concrete Curb14 Modified Roll Curb16 Mill and OverlayR1 Mulched Seeding, U27 M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CONSTRUCTION DETAILS.dwgDATE/USER: 1/9/2017 2:22 PM / TbennettCONSTRUCTION DETAILS LINE "PR-A" 1"=20' MATCH LINE 52+75 "PR-A"17MATCH LINE 47+00 "PR-A" 53+0054+0055+0056+0057+0058+00Connor Prairie Foundation Inc. Falcon Nest II LLC THE O V E R L O O K AT TH E L E G A C Y RIVER RD. T.B.M. 405 C.P. 117 Line "PR-A" N59°30'06"E "PR-A" K K 15 18 18 15 P.O.T. 57+81.39 "PR-A" = P.C. 57+81.39 "PR-A1" Constr. Limits Sec. 23, T18N, R4E Clay Township Hamilton County Sec. 23, T18N, R4E Clay Township Hamilton County Constr. Limits Line "PR-A1" P.I. = 58+68.94 "PR-A1" CURVE DATA PI = 58+68.94 "PR-A1" Delta = 12°29'26" Lt. R = 800.00 ft T = 87.55 ft L = 174.40 ft E = 4.78 ft +00 58' +00 62' P P 16'12'16'10'Str. No. 26, +50 "PR-A1" Inlet Type 'J-10' with 44' of 12" RCP Req'd. Str. No. 25, +50 "PR-A1" Inlet Type 'M-10' with 50' of 12" RCP & 1 Pipe End Section Req'd. Str. No. 24, +38 "PR-A" No Work Req'd. 30' Proposed Path/Drainage Easement Indianapolis Water Co. Easement +00 "PR-A" 76.36' +81.39 56.50'45' R/W "PR-A1" +R/W R/W' +40 "PR-A" 95.00' App. Exist. R/W App. Exist. R/W Handhole #2 52+94 "PR-A" Handhole #3 56+94 "PR-A" 12' x 8' ScourStop Transition Mat PROPOSED LEGEND (See Typical Sheet for Additional Details) Mill and Overlay with WedgeR Curb & Gutter Type II15 Sod26 Full Depth Asphalt PavementK Concrete SidewalkF Perpendicular Curb Ramp Curb & Gutter Type III18 HMA SidewalkP P C PCCP for Approaches, 9" on Subgrade Treatment Type II C2 PCCP, 7" with D-1 Contraction Joints at 15' Max. Spacing on 10" Compacted Aggregate No. 53 Base on Subgrade Treatment Type IB Concrete Curb14 Modified Roll Curb16 Mill and OverlayR1 Mulched Seeding, U27 M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CONSTRUCTION DETAILS.dwgDATE/USER: 1/9/2017 2:22 PM / TbennettCONSTRUCTION DETAILS LINE "PR-A" 1"=20'MATCH LINE 58+75 "PR-A"18MATCH LINE 52+75 "PR-A" 59+0060+0061+0062+0063+00(conc) (conc) (grvl) Connor Prairie Foundation Inc. Falcon Nest II LLC Falcon Nest II LLCTHE O V E R L O O K AT TH E L E G A C Y Line "PR-A" Line "PR-A"R/WR/WConstr. Limits N59°30'06"E "PR-A" +61.2+12.818.6 '19'18.9'16.9'22.2' 21. 6 ' 18' 26 K 15 15 15 K K K K 26 16 16 14 14 C2 C2 15 15 18 18 15 15 18 L 26 26 P P K K 26 10" p v c P.T. = 59+55.79 "PR-A1" Constr. Limits Constr. Limits Sec. 23, T18N, R4E Clay Township Hamilton County Sec. 23, T18N, R4E Clay Township Hamilton County 15 18 15 Constr. Limits RIVER RD. RIVER RD. P.I. = 13+18.03 "W-ENT" P.T. 13+47.36 "W-ENT" = O.P.O.C. 18.00 Rt., 1+96.60 "B" P.C.C. = 12+86.77 "W-ENT"S33°53'44"ES0°49'18"WS30°53'40"ELine "W-EXIT"Line "W-ENT"18 P R/W50' R/W App. PLApp. PLApp. PL10" pvc CURVE DATA P.I. = 13+18.03 "W-ENT" Delta = 34°43'02" Rt. R = 100.00 ft T = 31.26 ft L = 60.59 ft E = 4.77 ft App. Exist. R/W App. Exist. R/W App. Exist. R/W 1+002+003+00 0+00Line "B" P.O.C. 3+18.87 "B" = P.O.T. 61+51.55 "PR-A" Line "PR-A1 " N47°00'40" E 64+00Line "PR-A2"N63°04'33"E P 18 P 1 0 ' 6' P P 16'12'16'16'20'16'6'10'Str. No. 27, +50 "PR-A1" Inlet Type 'J-10' with 5' of 12" RCP Req'd. Str. No. 29, +58 "PR-A1" Inlet Type 'M-10' with 56' of 12" RCP Req'd.Str. No. 28, +50 "PR-A1" Inlet Type 'A-R4342' with 11' of 12" RCP Req'd. Str. No. 31, +75 "PR-A1" Inlet Type 'M-10' with 28' of 12" RCP Req'd. Str. No. 30, +83 "PR-A1" Manhole Type 'C-4' with 220' of 24" RCP & 1 Pipe End Section Req'd. Str. No. 32, 0+65 "PR-A2" Manhole Type 'C-4' with 92' of 24" RCP Req'd. Str. No. 36, +85 "PR-A2" Manhole Type 'C-4' with 220' of 24" RCP Req'd. Str. No. 37, +85 "PR-A2" Inlet Type 'M-10' with 22' of 12" RCP Req'd. Str. No. 38, +93 "PR-A2" Inlet Type 'J-10' with 5' of 12" RCP Req'd. Str. No. 33, +77 "PR-A2" Inlet Type 'J-10' with 5' of 12" RCP Req'd.Str. No. 35, +85 "PR-A2" Inlet Type 'M-10' with 27' of 12" RCP Req'd. Str. No. 83, +68 "W-ENT" Adjust Casting to Grade R/ W FUTURE LANES AND PATH F Proposed Path/Drainage E s m n t . Indianapolis Water Co. Easement +09.87 "PR-A1" 65' 45' R/W "PR-A 1 " 45' R/W "PR-A1" +P.T.(55.79) "PR-A1" 45' +85 "PR-A1" 45' +40 "W-EXIT" 35'35' R/W+90 "PR-A2" 70' +30 "PR-A2" 50' P.O.C. 0+39.27 "B" = P.O.T. 62+24.02 "PR-A" P.O.T. 61+38.33 "PR-A1" = P.O.C. 2+54.03 "B" P.O.T. 62+37.94 "PR-A2" = P.O.C. 0+62.48 "B" P.O.T. 14+01.41 "W-EXIT" = P.O.C. 1+49.14 "B" Str. No. 32A, 1+54 "B" Manhole Type 'C-4' with 2' of 24" RCP & 4' of 12" HDPE Req'd.CHERRY CREEK BLVD.Str. No. 32B, 1+60 "B" Manhole Type 'C-4' with 135' of 24" RCP Req'd. Str. No. 32C, 1+57 "B" Aqua Swirl Type 'AS-6' with 4' of 12" HDPE Req'd.6' Handhole #4 60+94 "PR-A" Handhole #6 62+55 "PR-A" Handhole #5 61+09 "PR-A" PROPOSED LEGEND (See Typical Sheet for Additional Details) Mill and Overlay with WedgeR Curb & Gutter Type II15 Sod26 Full Depth Asphalt PavementK Concrete SidewalkF Perpendicular Curb Ramp Curb & Gutter Type III18 HMA SidewalkP P C PCCP for Approaches, 9" on Subgrade Treatment Type II C2 PCCP, 7" with D-1 Contraction Joints at 15' Max. Spacing on 10" Compacted Aggregate No. 53 Base on Subgrade Treatment Type IB Concrete Curb14 Modified Roll Curb16 Mill and OverlayR1 Mulched Seeding, U27 M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CONSTRUCTION DETAILS.dwgDATE/USER: 1/9/2017 2:22 PM / TbennettCONSTRUCTION DETAILS LINE "PR-A" 1"=20' MATCH LINE 65+00 "PR-A"19MATCH LINE 58+75 "PR-A"MATCH LINE 13+00 "W-EXIT" 66+0067+0068+0069+0070+00(grvl) Falcon Nest II LLC Connor Prairie Foundation Inc. RIVER RD. Line " P R - A " Line "PR - A "16'16'20'Exist. 50' R/W 50' R/W N59° 3 0 ' 0 6 " E " P R - A " P.I. = 67+30.66 "PR-A" CURVE DATA P.I. = 67+30.66 "PR-A" Delta = 37°39'59" Lt. R = 550.00 ft T = 187.59 ft L = 361.57 ft E = 31.11 ft Normal Crown N21°50' 0 7 " E " P R - A " 18 26 K K 18 15 15 10" pvc 10" pvc 10 " p v c P.C. 65+43.07 "PR-A" = P.O.C. 65+43.07 "PR-A2" P.C. = 65+08.76 "PR-A2" P.T. = 69+04.64 "PR-A" Constr . L i m i t s Constr. Limits Constr. Limits Sec. 23, T18N, R4E Clay Township Hamilton County Sec. 2 3 , T 1 8 N , R 4 E Clay T o w n s h i p Hamil t o n C o u n t y Sec. 23, T18N, R4E Clay Township Hamilton County Constr. Limits P.I. = 65+25.92 "PR-A2" CURVE DATA P.I. = 65+25.92 "PR-A2" Delta = 3°34'27" Lt. R = 550.00 ft T = 17.16 ft L = 34.31 ft E = 0.27 ft Normal Crown P P P 6'10'Str. No. 38, +93 "PR-A2" Inlet Type 'J-10' with 5' of 12" RCP Req'd. Str. No. 33, +77 "PR-A2" Inlet Type 'J-10' with 5' of 12" RCP Req'd. Str. No. 35, +85 "PR-A2" Inlet Type 'M-10' with 27' of 12" RCP Req'd. Str. No. 43, +50 "PR-A" Inlet Type 'J-10' with 22' of 12" RCP Req'd. Str. No. 42, +50 "PR-A" Manhole Type 'C-4' with 165' of 21" RCP Req'd. Str. No. 41, +50 "PR-A" Inlet Type 'M-10' with 27' of 15" RCP Req'd. Str. No. 40, +50 "PR-A" 23' of 12" RCP and 1 Pipe End Section Req'd. Str. No. 45, +50 "PR-A" Inlet Type 'A-R4342' with 25' of 12" RCP Req'd. Str. No. 46, +50 "PR-A" Inlet Type 'M-10' with 22' of 12" RCP Req'd. Str. No. 49, +58 "PR-A" Inlet Type 'J-10' with 5' of 12" RCP Req'd. Str. No. 39, +72 "PR-A" No Work Req'd. Str. No. 44, +02 "PR-A" No Work Req'd.15' Pro p o s e d P a t h / D r ai n a g e E a s e m e n t Indianapolis Water Co. Easement +P.C. (08.76) "PR-A2" 50' +P.T. (04.64) 50'50' R/W +P.L. P.L.' R/WApp. PL+P.L. 50.00' Str. No. 42A, +20 "PR-A" Manhole Type 'C-4' with 171' of 21" RCP Req'd. Harvest Bi b l e C h a p e l o f North In d i a n a p ol i s I n c . Handhole #7 66+55 "PR-A" 66' x 4' ScourStop Turf Reinforcement Mat 4' x 4' ScourStop Transition Mat +42+08PROPOSED LEGEND (See Typical Sheet for Additional Details) Mill and Overlay with WedgeR Curb & Gutter Type II15 Sod26 Full Depth Asphalt PavementK Concrete SidewalkF Perpendicular Curb Ramp Curb & Gutter Type III18 HMA SidewalkP P C PCCP for Approaches, 9" on Subgrade Treatment Type II C2 PCCP, 7" with D-1 Contraction Joints at 15' Max. Spacing on 10" Compacted Aggregate No. 53 Base on Subgrade Treatment Type IB Concrete Curb14 Modified Roll Curb16 Mill and OverlayR1 Mulched Seeding, U27 M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CONSTRUCTION DETAILS.dwgDATE/USER: 1/9/2017 2:22 PM / TbennettCONSTRUCTION DETAILS LINE "PR-A" 1"=20' MATCH LINE 70+50 "PR-A"20MATCH LINE 65+00 "PR-A" 72+0073+0074+0075+0076+00(conc) (grvl) (conc) (asph)(asph) (asph) (grvl) 18" rcp 18" rcp App. Exist. R/WApp. PLConnor Prairie Foundation Inc. App. Exist. R/W Harvest Bible Chapel of North Indianapolis Inc. RIVER RD. C.P. 105 T.B.M. 407 Line "PR-A"16'16'20'10'Exist. 50' R/W N21°50'07"E "PR-A" 18 15 18 15 K K 26 10" pvc 8" pvc 8" pvc Constr. Limits Constr. Limits Sec. 23, T18N, R4E Clay Township Hamilton County Sec. 23, T18N, R4E Clay Township Hamilton County Constr. Limits71+006'P +43 34'+94 38'R310'R1,052'Str. No. 45, +50 "PR-A" Inlet Type 'A-R4342' with 25' of 12" RCP Req'd. Str. No. 46, +50 "PR-A" Inlet Type 'M-10' with 22' of 12" RCP Req'd. Str. No. 49, +58 "PR-A" Inlet Type 'J-10' with 5' of 12" RCP Req'd. Str. No. 48, +50 "PR-A" Inlet Type 'M-10' with 27' of 12" RCP Req'd. Str. No. 50, +58 "PR-A" Inlet Type 'J-10' with 5' of 12" RCP Req'd. Str. No. 47, +50 "PR-A" Manhole Type 'C-4' with 230' of 21" RCP Req'd. Str. No. 53, +00 "PR-A" Manhole Type 'C-4' with 250' of 15" RCP Req'd. Str. No. 52, +00 "PR-A" Inlet Type 'J-10' with 22' of 12" RCP Req'd. Str. No. 54, +00 "PR-A" Inlet Type 'J-10' with 27' of 12" RCP Req'd. Str. No. 58, +50 "PR-A" Inlet Type 'J-10' with 22' of 12" RCP Req'd. Str. No. 59, +50 "PR-A" Inlet Type 'J-10' with 27' of 12" RCP Req'd. Str. No. 51, +28 "PR-A" No Work Req'd. Str. No. 55, +70 "PR-A" No Work Req'd. Str. No. 56, +00 "PR-A" 50' of 12" RCP and 2 Pipe End Sections Req'd. Indianapolis Water Co. Easement +P.L. P.L.'R/W R/W To Be Dedicated Class V +21, W=20' Str. No. 61, +21 "PR-A" 34' of 18" RCP and 2 Pipe End Sections Req'd. Remove Remove Str. No. 57, +50 "PR-A" Manhole Type 'C-4' with 250' of 12" RCP Req'd. Harvest Bible Chapel of North Indianapolis Inc. Handhole #8 70+55 "PR-A" Handhole #9 74+55 "PR-A" 4' x 4' ScourStop Transition Mat 4' x 4' ScourStop Transition Mat PROPOSED LEGEND (See Typical Sheet for Additional Details) Mill and Overlay with WedgeR Curb & Gutter Type II15 Sod26 Full Depth Asphalt PavementK Concrete SidewalkF Perpendicular Curb Ramp Curb & Gutter Type III18 HMA SidewalkP P C PCCP for Approaches, 9" on Subgrade Treatment Type II C2 PCCP, 7" with D-1 Contraction Joints at 15' Max. Spacing on 10" Compacted Aggregate No. 53 Base on Subgrade Treatment Type IB Concrete Curb14 Modified Roll Curb16 Mill and OverlayR1 Mulched Seeding, U27 M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CONSTRUCTION DETAILS.dwgDATE/USER: 1/9/2017 2:22 PM / TbennettCONSTRUCTION DETAILS LINE "PR-A" 1"=20' MATCH LINE 76+50 "PR-A"21MATCH LINE 70+50 "PR-A" 77+0078+0018" rcp 18" rcp 18" rcp (asph) (asph) (asph) (grvl)(grvl)App. Exis t . R / W App. Exist. R/W App. Exi s t . R / W ZConnor Prairie Foundation Inc. C.P. 152 Line "PR-A" Line "PR- A " CURVE DATA P.I. = 77+84.50 "PR-A" Delta = 13°44'20" Rt. R = 1000.00 ft T = 120.47 ft L = 239.79 ft E = 7.23 ft Normal Crown P.I. = 77+84.50 "PR-A" N35°34' 2 8 " E " P R - A "+14+14+1426'26'+01+1838'10'16'10'+05+04K K 18 18 P.C. = 76+64.03 "PR-A" P.T. = 79+03.82 "PR-A"+05+14Sec. 23, T18N, R4E Clay Township Hamilton County Sec. 23, T18N, R4E Clay Township Hamilton County Harvest Bible Chapel of North Indianapolis Inc. 15 15 K R 15 15 18 18 Constr. Limits Constr. Limits79+0080+0081+0082+00RIVER R D .16'16'20'10'38'16'16'20'+85 55'R1,052'+13 53'+83 62'+95 60' +70 51' +70 66'R20'R110'R300'P P 26 26 C C Comm. Dr. +63, W=63' Str. No. 65, +25 "PR-A" Inlet Type 'J-10' with 52' of 12" RCP Req'd. Str. No. 64, +25 "PR-A" Inlet Type 'M-10' with 18' of 12" RCP & 1 Pipe End Section Req'd. Str. No. 67, +60 "PR-A" Inlet Type 'M-10' with 52' of 12" RCP Req'd. Str. No. 60, +22 "PR-A" No Work Req'd.24'+34 56'10'Str. No. 63, +03 "PR-A" Inlet Type 'M-10' with 15' of 12" RCP Req'd.Str. No. 62, +03 "PR-A" Manhole Type 'C-4' Connect to Exist. 18" Pipe F P P C Str. No. 61A, +19 "PR-A" 30' of 15" RCP and 2 Pipe End Sections Req'd. +25 55' +08 52'R90'R50'R50'Modified Class III +89, W=12' Modified Class III +19, W=12'10'10'Str. No. 61B, +89 "PR-A" 31' of 15" RCP and 2 Pipe End Sections Req'd. Str. No. 63A, +64 "PR-A" Inlet Type 'A-R4342' with 38' of 12" RCP Req'd. Remove Remove Handhole #10 78+55 "PR-A" Handhol e # 1 1 82+55 " P R - A " 4' x 4' ScourStop Transition Mat 4' x 4' ScourStop Transition Mat Adjust Valve to Grade PROPOSED LEGEND (See Typical Sheet for Additional Details) Mill and Overlay with WedgeR Curb & Gutter Type II15 Sod26 Full Depth Asphalt PavementK Concrete SidewalkF Perpendicular Curb Ramp Curb & Gutter Type III18 HMA SidewalkP P C PCCP for Approaches, 9" on Subgrade Treatment Type II C2 PCCP, 7" with D-1 Contraction Joints at 15' Max. Spacing on 10" Compacted Aggregate No. 53 Base on Subgrade Treatment Type IB Concrete Curb14 Modified Roll Curb16 Mill and OverlayR1 Mulched Seeding, U27 M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CONSTRUCTION DETAILS.dwgDATE/USER: 1/9/2017 2:22 PM / TbennettCONSTRUCTION DETAILS LINE "PR-A" 1"=20' MATCH LINE 82+50 "PR-A"22MATCH LINE 76+50 "PR-A" 83+0085+0018" rcp24" rcp 24" rcp App. Exist. R/W App. Exist. R / WApp. PLApp. PL24" rcp Harvest Bible Chapel of North Indianapolis Inc. KLC Realty LLC RIVER RD.16'16'20'10'N35°34'28"E "PR-A" CURVE DATA P.I. = 86+70.63 "PR-A" Delta = 35°28'47" Lt. R = 730.00 ft T = 233.53 ft L = 452.04 ft E = 36.44 ft Normal Crown P.I. = 86+70.63 "PR-A"4'10'20'16'+72+34 K R15 18 15 26 +72P.C. = 84+37.10 "PR-A"38'Sec. 23, T18N, R4E Clay Township Hamilton County Sec. 23, T18N, R4E Clay Township Hamilton County KLC Realty L L C Connor Prairie Foundation Inc. 18 15 K 15 15 Constr. Li mits Constr. Limits Constr. Limits N0°0 5' 4 0" E " P R- A"84+0086+0087+00+72+30R K R1 P K 18 P Str. No. 69, +66 "PR-A" Inlet Type 'J-10' with 3' of 12" RCP Req'd. Str. No. 67, +60 "PR-A" Inlet Type 'M-10' with 52' of 12" RCP Req'd. Str. No. 68, +66 "PR-A" Inlet Type 'J-10' with 3' of 12" RCP Req'd. Str. No. 66, +60 "PR-A" Inlet Type 'M-10' with 16' of 12" RCP & 1 Pipe End Section Req'd. Str. No. 72, +50 "PR-A" Inlet Type 'J-10' with 15' of 12" RCP & 1 Pipe End Section Req'd. Str. No. 70, +04 "PR-A" Inlet Type 'E-7' with 24' of 18" RCP Req'd. 24" rcp Str. No. 71, +06 "PR-A" No Work Req'd. Str. No. 73, +40 "PR-A" Adjust Casting to Grade Str. N o. 7 4, + 3 1 " P R- A" No W or k R e q' d. Line "PR-A" R Handhole #11 82+55 "PR-A" Handhole #12 86+55 "PR-A"+7018 18 4' x 4' ScourStop Transition Mat 4' x 4' ScourStop Transition Mat 4' x 8' ScourStop Transition Mat Adjust Valves to Grade Adjust Hydrant to Grade Adjust Valve to Grade Adjust V al v es to Grad e Adjust H y dr a nt to Gr a d e PROPOSED LEGEND (See Typical Sheet for Additional Details) Mill and Overlay with WedgeR Curb & Gutter Type II15 Sod26 Full Depth Asphalt PavementK Concrete SidewalkF Perpendicular Curb Ramp Curb & Gutter Type III18 HMA SidewalkP P C PCCP for Approaches, 9" on Subgrade Treatment Type II C2 PCCP, 7" with D-1 Contraction Joints at 15' Max. Spacing on 10" Compacted Aggregate No. 53 Base on Subgrade Treatment Type IB Concrete Curb14 Modified Roll Curb16 Mill and OverlayR1 Mulched Seeding, U27 M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CONSTRUCTION DETAILS.dwgDATE/USER: 1/9/2017 2:22 PM / TbennettCONSTRUCTION DETAILS LINE "PR-A" 1"=20' MATCH LINE 88+50 "PR-A"23MATCH LINE 82+50 "PR-A" 89+0090+0091+0092+00(grvl) App. Exist. R/W App. Exist. R/W App. Exist. R/WApp. Exist. R/WApp. PL24" rcp 24" rcp 24" rcp 12" rcp??" rcp??" rcpRIVER RD. Sec. 23, T18N, R4E Clay Township Hamilton County Connor Prairie Foundation Inc. L & Q Realty LLC C.P. 119 T.B.M. 408 Line "PR-A" N0°05'40"E "PR-A"+95END PROJECT 90+55.00 "PR-A"+7229'29'P.T. = 88+89.14 "PR-A" Constr. Limits Sec. 23, T18N, R4E Clay Township Hamilton County KLC Realty LLC 18 15 Constr. Limits Constr. Limits K R1 K R1+132'P Str. No. 74, +31 "PR-A" No Work Req'd.Str. No. 75, +85 "PR-A" No Work Req'd. Str. No. 77, +56 "PR-A" Furnish Type 2 Casting and Adjust to Grade Str. No. 76, +56 "PR-A" Furnish Type 3 Casting and Adjust to Grade Str. No. 78, +56 "PR-A" No Work Req'd.146TH ST.R Handhole #13 90+55 "PR-A" Adjust Valves to Grade Adjust Hydrant to Grade PROPOSED LEGEND (See Typical Sheet for Additional Details) Mill and Overlay with WedgeR Curb & Gutter Type II15 Sod26 Full Depth Asphalt PavementK Concrete SidewalkF Perpendicular Curb Ramp Curb & Gutter Type III18 HMA SidewalkP P C PCCP for Approaches, 9" on Subgrade Treatment Type II C2 PCCP, 7" with D-1 Contraction Joints at 15' Max. Spacing on 10" Compacted Aggregate No. 53 Base on Subgrade Treatment Type IB Concrete Curb14 Modified Roll Curb16 Mill and OverlayR1 Mulched Seeding, U27 M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CONSTRUCTION DETAILS.dwgDATE/USER: 1/9/2017 2:22 PM / TbennettCONSTRUCTION DETAILS LINE "PR-A" 1"=20' MATCH LINE 88+50 "PR-A"24 62+0063+0015 Sec. 23, T18N, R4E Clay Township Hamilton County Line "W -ENT " Falcon Nest II LLC Falcon Nest II LLC N9 0 ° 0 0 ' 0 0 " E S33°53'44"EP.I. = 11+23.41 "W-ENT" P.C. = 9+28.38 "W-ENT" 16' 10'6' 16'10'6' BEGIN CONSTRUCTION 10+87.76 "W-ENT"S30°53'40"ELine "W-EXIT"P.I. = 11+63.60 "W-EXIT"CURVE DATA P.I. = 11+63.60 "W-EXIT" Delta = 34°23'49" Rt. R = 250.00 ft T = 77.38 ft L = 150.08 ft E = 11.70 ft CURVE DATA P.I. = 11+23.41 "W-ENT" Delta = 56°06'16" Rt. R = 366.00 ft T = 195.03 ft L = 358.39 ft E = 48.72 ft 12+00 11+ 0 0 P.T. = 12+36.31 "W-EXIT" S 6 5 ° 1 7 ' 3 0 " E BEGIN CONSTRUCTION P.O.C. 10+86.22 "W-EXIT" = O.P.O.C. 68.00 Lt., 10+86.22 "W-ENT" 2618 18 15 15 15 35' R /W35' R/WConstr. Limits Constr. Limits Constr. LimitsApp. PLApp. P L 10" pvc 10" p v c 64+00P P K R1 R1 K K K R1 P P K K K +62 Str. No. 82, +00 "W-ENT" Inlet Type 'M-10' with 37' of 12" RCP & 1 Pipe End Section Req'd. Str. No. 81, +00 "W-EXIT" Inlet Type 'M-10' with 38' of 12" RCP & 1 Pipe End Section Req'd. Str. No. 79, +72 "W-ENT" No Work Req'd. A p p . E x i s t . R /W A p p . E x i s t . R /W A p p . E x i s t . R / W A p p . E x i s t . R /W App. P L Ap p . E x i s t . R / W Ap p . E x i s t . R / W App. Ex is t . R/W +P.T. (36.31) "W-EXIT" 35' +00 "W-EXIT" 35' +R/W "W-EXIT" R/W +R/W "W-ENT" R/W R/WR/W Str. No. 80, +06 "W-EXIT" Inlet Type 'J-10' with 3' of 12" RCP Req'd. Str. No. 82A, +06 "W-ENT" Inlet Type 'J-10' with 3' of 12" RCP Req'd.CHERRY CREEK BLVD.Handhole #14 10+90 "W-ENT" 4' x 4' ScourStop Transition Mat 4' x 4' ScourStop Transition Mat PROPOSED LEGEND (See Typical Sheet for Additional Details) Mill and Overlay with WedgeR Curb & Gutter Type II15 Sod26 Full Depth Asphalt PavementK Concrete SidewalkF Perpendicular Curb Ramp Curb & Gutter Type III18 HMA SidewalkP P C PCCP for Approaches, 9" on Subgrade Treatment Type II C2 PCCP, 7" with D-1 Contraction Joints at 15' Max. Spacing on 10" Compacted Aggregate No. 53 Base on Subgrade Treatment Type IB Concrete Curb14 Modified Roll Curb16 Mill and OverlayR1 Mulched Seeding, U27 M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CONSTRUCTION DETAILS.dwgDATE/USER: 1/9/2017 2:22 PM / TbennettCONSTRUCTION DETAILS LINE "W-EXIT" & "W-ENT" 1"=20' 25 MATCH LINE 13+00 "W-EXIT" 59+0060+0061+0062+0063+00RIVER RD. RIVER RD. 16'10'6'Line "W-EXIT"Line "W-ENT"1+002+003+0 0 0+00Line "B" Line "PR-A 1 "64+00Line "PR-A2"16'12'16'16'16'1.5% 1.8%0.9%2. 0% 0.6%1.5%1.8%2.0%2.1%2.0%2.1% 1.9 %1.0%0.8%2.0%755.62 0.52% 755.15 0.52% 755.24 0.50% 754.94 1.86%2.0%755.39 V.C.2.0%755.04 1.3 3 % 754.03 V.C. 753.61 754.85 0.96 % 753.44 1.75% 2.0% 754.73 754.65 2.0% 752.25 16'2.00%2.00%2.00%2.0%0.52% 754.94 65+0013+00 13+00 0.52% 754.98 754.77 754.77 Line "B" +37.29 "PR-A2" 26.00' Lt.20'+98 "W-ENT" 27.57' Rt. +49.36 "B" 18.00' Rt.0.50%0.8%1.5% 0.2%2.0%2.0%1.1 % 2.0% 0.66% 0.66 % +53.80 "PR-A1" 27.54' Rt. +43.11 "PR-A1" 10.00' Rt. 0.12% +75 "PR-A1" 25.06' Lt. 0.50% +15.49 "PR-A1" 31.06' Lt.1.53% 1.5% 752.84 752.99 1.5%1.5% 753.75 753.60 +58.26 "W-ENT" 16.00' Rt. 754.06 753.53 +06.16 "W-ENT" 20.25' Rt.3.03%+39.46 "W-ENT" 21.61' Rt. 755.36 1.21% +30.05 "B" 18.00' Rt. 1.86% +60.04 "PR-A2" 26.88' Rt. 1.5%1.5%V.C. +51.88 "PR-A2" 69.27' Lt. +33.09 "W-EXIT" 16.00' Lt. 754.85 +75.61 "B" 18.00' Rt. +68.84 "B" 18.00' Rt.0.77%755.37 0.50%0.73% +29.93 "PR-A2" 10.00' Lt.V.C. 761.00 12' 75 8 "W-ENT" 751 755 751 755 13+00 13+55 "PR-A2" 750 755 63+00 64+00 65+00 -1.86% 62+53.14 755.59 PVI STA: 65+00.00 PVI ELEV: 751.00 VCL: 420.00 "PR-A1" 753 755 753 755 61+00 61+30 61+25 755.44 +0.52% PVI STA: 60+75.00 PVI ELEV: 755.18 VCL: 70.00 +3.01% +2.00% "W-EXIT" 751 755 751 755 13+8512+75752.8513+10753.9013+47.37754.65+2.11% +2.00%13+40753.9013+81.33754.73"B" 753 755 753 755 1+00 2+00 3+00 3+58 -0.50%+0.54% EQ: Sta. 0+00.00 = 3+58.14 EQ: Sta. 3+58.14 = 0+00.00 See Plan & Profiles for continuation of profile See Plan & Profiles for continuation of profile See Plan & Profiles for continuation of profile See Plan & Profiles for continuation of profile +0.52% Line "W-EXIT" Line "W-ENT" Line "PR-A1" Line "B" Line "PR-A2"0+00755.881+85754.953+58.14755.88M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: SPOT ELEV.dwgDATE/USER: 1/9/2017 2:22 PM / TbennettSPOT ELEVATIONS 1"=20' 26 59+0060+0061+0062+0063+00RIVER RD . RIVER RD.Line "W-EXIT"Line "W-ENT"1+002+003+0 0 0+00Line "PR-A 1 "64+00Line "PR-A2"65+00Line "B" Line "PR-A" P.O.T. 61+51.55 "PR-A" = P.O.T. 3+18.87 "B" P.O.T. 61+38.33 "PR-A1" = P.O.C. 2+54.03 "B" P.O.C. 62+37.94 "PR-A2" = P.O.T. 0+62.48 "B" P.O.T. 14+01.41 "W-EXIT" = P.O.C. 1+49.14 "B" P.T. 13+47.36 "W-ENT" = O.P.O.C. 18.00 Rt., 1+96.60 "B"CHERRY CREEK BLVD.755 750746 757 755 757756755 751 753 755 754 755 75 7 755 754 757 757 75 7 7 5 5 75 3 M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: RAB CONTOUR SHEETS.dwgDATE/USER: 1/10/2017 8:34 AM / MmastersonEXISTING CONTOURS 1"=20' 27 59+0060+0061+0062+0063+00RIVER RD . RIVER RD.Line "W-EXIT"Line "W-ENT"1+002+003+0 0 0+00Line "PR-A 1 "64+00Line "PR-A2"65+00Line "B" Line "PR-A" P.O.T. 61+51.55 "PR-A" = P.O.T. 3+18.87 "B" P.O.T. 61+38.33 "PR-A1" = P.O.C. 2+54.03 "B" P.O.C. 62+37.94 "PR-A2" = P.O.T. 0+62.48 "B" P.O.T. 14+01.41 "W-EXIT" = P.O.C. 1+49.14 "B" P.T. 13+47.36 "W-ENT" = O.P.O.C. 18.00 Rt., 1+96.60 "B"CHERRY CREEK BLVD.CROSS SECTION MATCH LINE STA. 63+37 "PR-A2" CROSS SECTION MATCH LINE STA. 63+50 "PR-A1" CROSS SECTION MATCH LINE STA. 12+58 "W-ENT" CROSS SECTION MATCH LINE STA. 13+33 "W-EXIT" EARTHWORK FOR AREA WITHIN THESE MATCH LINES ARE CALCULATED IN CIVIL 3D TAKING THE PROPOSED CONTOURS ON THIS SHEET AND SUBTRACTING THE PROPOSED PAVEMENT DEPTH AND THE EXISTING CONTOURS ON SHEET 27. RAW EARTHWORK CUT = 3555 CYDS FILL = 276 CYDS SEE CROSS SECTIONS FOR EARTHWORK QUANTITIES OUTSIDE OF MATCH LINES SHOWN HERE.CHERRY CREEK BLVD.755755 755 755 755 7 5 6 756 755CROSS SECTION MATCH LINE STA. 12+58 "W-ENT" CROSS SECTION MATCH LINE STA. 13+33 "W-EXIT"754755751756756 754 7 5 7 754 753 7557 61 757 7 6 0 M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: RAB CONTOUR SHEETS.dwgDATE/USER: 1/10/2017 8:34 AM / MmastersonPROPOSED CONTOURS 1"=20' 28 59+0060+0061+0062+0063+00P.O.T. 57+81.39 "PR-A" = P.C. 57+81.39 "PR-A1" RIVER RD. 16'10'6'Line "W-EXIT"Line "W-ENT"1+002+003+0 0 0+00Line "PR-A1" Line "PR-A 1 "64+00Line "PR-A2"16'12'16'16'16'16' 13+00 13+00 Line "B"19'16.9'20'18.9'18.6 ' 21. 6 ' 22.2' 18' (Typ) 6'10'10'6'10'10'45'10'Line "PR-A"R=110'R=100'R=798'R= 1 1 5 ' R=13 0'R=100'R=110'R=80' R=57' R= 3 . 5 ' R=75'R=75'R=1 0 0 ' +18.72 "PR-A1" 20.54' Lt. +20.01 "PR-A1" 4.59' Lt. +91.01 "PR-A1" 26.37' Lt. +18.54 "PR-A1" 12.54' Lt. +43.11 "PR-A1" 10.00' Rt. +36.31 "PR-A1" 26.00' Rt. +08.52 "PR-A1" 31.56' Rt. +00 "PR-A1" 55.00' Lt. +50 "PR-A1" 47.00' Lt. +00 "PR-A1" 40.00' Lt. +90.37 "PR-A1" 34.35' Lt. +50 "PR-A1" 55.50' Lt. +81.39 "PR-A1" 56.50' Lt.R=826'R=782'R=810'+39.35 "W-ENT" 0.00' +86.77 "W-ENT" 0.00' +58.26 "W-ENT" 16.00' Rt. +38.18 "W-ENT" 0.00' Rt. +72.50 "W-EXIT" 0.00' +76.26 "W-EXIT" 0.00' +43.05 "W-EXIT" 24.41' Lt. +33.09 "W-EXIT" 16.00' Lt. +07.75 "W-ENT" 28.42' Rt. +13.15 "W-ENT" 10.58' Lt. +37.29 "PR-A2" 26.00' Lt. +29.93 "PR-A2" 10.00' Lt. +66.10 "PR-A2" 30.41' Lt. +88 "PR-A2" 38.99' Lt. +58.52 "PR-A2" 10.00' Rt. +71.89 "PR-A2" 26.00' Rt. +30.05 "B" 18.00' Rt. +30.54 "B" 18.00' Rt.+00.89 "PR-A1" 49.65' Rt. +64.15 "B" 18.00' Rt. +89.42 "B" 18.00' Rt. +60.67 "B" 18.00' Rt. +90.54 "B" 18.00' Rt. +54.65 "B" 18.00' Rt. +83.03 "B" 18.00' Rt. +81.39 "PR-A1" 26.00' Rt. +81.39 "PR-A1" 10.00' Rt. +81.39 "PR-A1" 2.00' Lt. +81.39 "PR-A1" 18.00' Lt. P.O.T. 61+51.55 "PR-A" = P.O.T. 3+18.87 "B" +87.78 "PR-A" 44.00' Lt.6'10'( T y p ) M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: GEOMETRIC SHEET.dwgDATE/USER: 12/1/2016 3:24 PM / TbennettGEOMETRIC SHEET 1"=20' 29 43+0042+0044+0045+0046+0047+0048+00COMMUNITY DR.RIVER RD.Line "PR-A"12'BEGIN PROJECT 44+79.00 "PR-A" 45 12'11.5'45 45 45+04+94+84+9416'16'42 42 B "40 mph" 47+58 "PR-A"B48+64 "PR-A" OM3 B OM3 48+34 "PR-A" PAVEMENT MARKING LEGEND Line, Thermoplastic, Solid Yellow, 4 Inches43 Line, Thermoplastic, Solid White, 4 Inches42 Transverse Marking, Thermoplastic, Crosswalk, White, 24 Inches41 45 Lane Indication Arrow, White, Thermoplastic Transverse Marking SIGNING LEGEND A No Change Required To Exist. Sign & Supports B Remove Exist. Sheet Sign & Supports 47 46 Line, Thermoplastic, Dotted White, 12 in., 2' Line, 2' Gap Transverse Marking, Thermoplastic, White Yield Line, 27 Inches C Relocate Exist. Sign On New Post(s) D New Sign And Post(s)50+0051+0052+0053+0054+0055+0056+00RIVER RD.Line "PR-A"16'16'48+34 "PR-A" B OM3 49+51 "PR-A" B OM3 50+38 "PR-A" M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: PM&SIGNING.dwgDATE/USER: 12/6/2016 1:49 PM / MmastersonPAVEMENT MARKINGS & SIGNING 1"=30'MATCH LINE 49+00 "PR-A"30MATCH LINE 56+50 "PR-A"MATCH LINE 49+00 "PR-A" 57+0058+0059+0060+0061+0062+0063+00RIVER RD. Line "PR-A"16'16'+73 46 46 46 41 41 47 47 47 43 43 43 W11-2 W16-7P R1-2 R1-2 R1-2 D D D13+03 "W-ENT" 13+40 "W-ENT" 13+36 "W-ENT" D 13+27 "W-ENT" D1-1d(2) D 62+83 "PR-A" 62+61 "PR-A" D1-1d(1) D D 62+67 "PR-A" 43 D D 61+00 "PR-A" 61+10 "PR-A" 61+09 "PR-A" D1-1d(1)D D D D 61+66 "PR-A" 61+51 "PR-A" 62+28 "PR-A"R6-1R R6-4a B "35 MPH" 61+95 "PR-A" C "One Way" 10+48 "W-ENT" A "30 mph" 10+70 "W-EXIT"43 43 A +38Line "W -ENT "Line "W -EX IT " +89 +57 +86+75+2811' 16' 16'16'16'M.P.H. W16-8P (1) W2-6 W13-1P CHERRY CREEK BLVD. D 57+50 "PR-A" 13+60 "W-EXIT" W11-2 W16-7PCHEERY CREEK BLVD.M.P.H. W16-8P (2) W2-6 W13-1P RIVER ROAD D 10+00 "W-ENT" 59+00 "PR-A" R2-1(40) D D PAVEMENT MARKING LEGEND Line, Thermoplastic, Solid Yellow, 4 Inches43 Line, Thermoplastic, Solid White, 4 Inches42 Transverse Marking, Thermoplastic, Crosswalk, White, 24 Inches41 45 Lane Indication Arrow, White, Thermoplastic Transverse Marking SIGNING LEGEND A No Change Required To Exist. Sign & Supports B Remove Exist. Sheet Sign & Supports 47 46 Line, Thermoplastic, Dotted White, 12 in., 2' Line, 2' Gap Transverse Marking, Thermoplastic, White Yield Line, 27 Inches C Relocate Exist. Sign On New Post(s) D New Sign And Post(s) M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: PM&SIGNING.dwgDATE/USER: 12/6/2016 1:49 PM / Mmasterson1"=30'MATCH LINE 64+00 "PR-A"31MATCH LINE 56+50 "PR-A"PAVEMENT MARKINGS & SIGNING 65+0066+0067+0068+0069+0070+00RIVER RD. Line "PR-A"16'16'R1-262+83 "PR-A" 62+67 "PR-A"16'16'B "Arrow Sign" 67+00 "PR-A" B "Arrow Sign" 67+84 "PR-A" M.P.H. W16-8P (1) W2-6 W13-1P CHERRY CREEK BLVD. D 66+20 "PR-A" R2-1(40) 64+50 "PR-A"D 72+0073+0074+0075+0076+0077+0078+00RIVER RD. Line "PR-A"16'16'26'B B "Arrow Sign" 73+44 "PR-A" 72+62 "PR-A" "Arrow Sign" B "40 mph" 76+70 "PR-A"+14+244542 45 14'12'PAVEMENT MARKING LEGEND Line, Thermoplastic, Solid Yellow, 4 Inches43 Line, Thermoplastic, Solid White, 4 Inches42 Transverse Marking, Thermoplastic, Crosswalk, White, 24 Inches41 45 Lane Indication Arrow, White, Thermoplastic Transverse Marking SIGNING LEGEND A No Change Required To Exist. Sign & Supports B Remove Exist. Sheet Sign & Supports 47 46 Line, Thermoplastic, Dotted White, 12 in., 2' Line, 2' Gap Transverse Marking, Thermoplastic, White Yield Line, 27 Inches C Relocate Exist. Sign On New Post(s) D New Sign And Post(s) M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: PM&SIGNING.dwgDATE/USER: 12/6/2016 1:49 PM / MmastersonMATCH LINE 71+00 "PR-A"32MATCH LINE 64+00 "PR-A"MATCH LINE 78+50 "PR-A"MATCH LINE 71+00 "PR-A"1"=30' PAVEMENT MARKINGS & SIGNING 79+0080+0081+0082+0083+0085+0087+0084+00RIVER RD. Line "PR-A"16'16'45 42 +14+9245 45 45 45 14'12'12'14'12'+05+15+05+9542 42 B "Arrow Sign" 81+09 "PR-A" B 83+37 "PR-A"87+0088+0089+0090+0091+0092+00RIVER RD. Line "PR-A"16'16'END PROJECT 90+55.00 "PR-A"146TH STREETA "40 mph" 86+78 "PR-A" 43 43 42 45 45 43 +73+13+03+9220'12'16'A "Arrow Sign" 90+99 "PR-A" PAVEMENT MARKING LEGEND Line, Thermoplastic, Solid Yellow, 4 Inches43 Line, Thermoplastic, Solid White, 4 Inches42 Transverse Marking, Thermoplastic, Crosswalk, White, 24 Inches41 45 Lane Indication Arrow, White, Thermoplastic Transverse Marking SIGNING LEGEND A No Change Required To Exist. Sign & Supports B Remove Exist. Sheet Sign & Supports 47 46 Line, Thermoplastic, Dotted White, 12 in., 2' Line, 2' Gap Transverse Marking, Thermoplastic, White Yield Line, 27 Inches C Relocate Exist. Sign On New Post(s) D New Sign And Post(s) M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: PM&SIGNING.dwgDATE/USER: 12/6/2016 1:49 PM / Mmasterson1"=30'MATCH LINE 86+00 "PR-A"33MATCH LINE 78+50 "PR-A"MATCH LINE 86+00 "PR-A"PAVEMENT MARKINGS & SIGNING 43+0042+0044+0045+0046+0047+0048+00(grvl)(sign)12" rcp12" rcp27" Conc.(riprap) App. Exist. R/W App. Exist. 45' R/W A p p . P L COMMUNITY DR.RIVER RD.Line "PR-A" 18" plastic Constr. Limits Indianapolis Water Company Easement VariesExist. 50' R/W Constr. Limits Str. No. 15 Str. No. 18 Str. No. 19 Str. No. 12 Str. No. 11 Str. No. 13 Str. No. 16Str. No. 14 Str. No. 10 Str.No. 17 Proposed Path/Drainage Easement Silt Fence Silt Fence BEGIN PROJECT 44+79.00 "PR-A" 1 1 11 1 1 1 1 745 750 744746747748 749 7 5 1 75 2 740740 745745750741741742742743743744744 7467467477487497517524' x 4' ScourStop Transition Mat LEGEND EXISTING Storm Manhole Gas Line Storm Inlets Sanitary Manhole Gas ValveGas Meter Sanitary Cleanout Water Line Water ValveFire Hydrant Sprinkler Electric Line Power Pole w/(Riser)Light & Power Pole Light & Power Pole w/Riser Water Meter Light PoleGuy Wire Electric Box Fiber Optic LineTelephone Line Telephone ManholeCable TV LineCable TV Box Telephone Riser Utility ManholeWood Fence Iron PinSign Flag PoleBushTree TrunkDeciduous TreeConiferous Tree Overhead Utility Line Wood Fence Wire FenceChainlink FenceIron FenceIrr. Valve Mailbox EROSION CONTROL SILT FENCE TEMPORARY INLET PROTECTION TEMPORARY RIPRAP CHECK DAM, MODIFIED EROSION CONTROL BLANKET 1 50+0051+0052+0053+0054+0055+0056+00(riprap) 18" plastic App. Exist. 45' R/W RIVER RD. Line "A" Line "PR-A" Exist. 50' R/W 18" plastic Constr. Limits Constr. Limits N59°30'06"E "PR-A" Str. No. 21 Str. No. 22 Str. No. 18 Str. No. 19 Str.No. 20 Str.No. 23 Str.No. 24 Proposed Path/Drainage Easement Silt Fence Silt Fence 1 1 1 1 +60+80+00+50745744 745750755743744746747748749751752753754756757757745745 750 750 755755746 746 747 747 748 748749 749 751 751752 752753 753754 7544' x 4' ScourStop Transition Mat 8' x 12' ScourStop Transition Mat 4' x 4' ScourStop Transition Mat M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: EC LINE PR-A.dwgDATE/USER: 1/11/2017 1:10 PM / TybennettEROSION CONTROL LINE "PR-A" 1"=30'MATCH LINE 49+00 "PR-A"34MATCH LINE 56+50 "PR-A"MATCH LINE 49+00 "PR-A" LEGEND EXISTING Storm Manhole Gas Line Storm Inlets Sanitary Manhole Gas ValveGas Meter Sanitary Cleanout Water Line Water ValveFire Hydrant Sprinkler Electric Line Power Pole w/(Riser)Light & Power Pole Light & Power Pole w/Riser Water Meter Light PoleGuy Wire Electric Box Fiber Optic LineTelephone Line Telephone ManholeCable TV LineCable TV Box Telephone Riser Utility ManholeWood Fence Iron PinSign Flag PoleBushTree TrunkDeciduous TreeConiferous Tree Overhead Utility Line Wood Fence Wire FenceChainlink FenceIron FenceIrr. Valve Mailbox EROSION CONTROL SILT FENCE TEMPORARY INLET PROTECTION TEMPORARY RIPRAP CHECK DAM, MODIFIED EROSION CONTROL BLANKET 157+0058+0059+0060+0061+0062+0063+00(conc) (grvl) App. Exist. 45' R/W App. PLRIVER RD. Line "PR-A"R/W R/W R/WConstr. Limits Constr. Limits 10" p v c Exist. 50' R/W Constr. Limits Line "PR-A2" Line "PR-A1" Line "B"0+001+002+003+00 P.O.T. 3+18.87 "B" = P.O.T. 61+51.55 "PR-A" Str. No. 28 Str. No. 25 Str. No. 26 Str. No. 32 Str. No. 30 Str. No. 27 Str. No. 29 Str. No. 31 Proposed Path/Drainage Easement R/W App. PL Proposed Path/Drainage Easem e n t Str. No. 32A Silt Fence Silt Fence 1 1 1 1 1 1 +00+00+40Str. No. 32B Str. No. 32C 745 750755746 747 748749751752753 754755 753 754756 755 755755 754 756 7 5 6 756 757 757+8012' x 8' ScourStop Transition Mat Aqua-Swirl Structure 65+0066+0067+0068+0069+0070+00(grvl) RIVER RD. Line "PR - A " Exist. 50' R/W 50' R/W R/W 10" pvc 10" pvc 1 0 " p v c Constr. Limits Constr. Limits Line " P R - A 2 " Line " P R - A 2 " Str. No. 47 Str. No. 49 Str. No. 50 Str. No. 46 Str. No. 48 Str. No. 45 Str. No. 42 Str. No. 43 Str. No. 41 Str. No. 36 Str. No. 37 Str. No. 38 Str. No. 35 Str. No. 33 Str. No. 39 Str. No. 40 Str. No. 44 R/W Propose d P a t h / D r a i n a g e E a s e m e n t Str. No. 42A R/WApp. PL App. PL App. PL Silt Fence Silt Fence 1 1 1 1 1+10+001 1 1 1 1 +75+60+50+00+00+40+60+001 755756 750750 755 751751 752752 753753753 754 756 757758 755 755753753754754756 756757 759 66' x 4' ScourStop Turf Reinforcement Mat 4' x 4' ScourStop Transition Mat M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: EC LINE PR-A.dwgDATE/USER: 1/11/2017 1:10 PM / TybennettEROSION CONTROL LINE "PR-A" 1"=30' 1"=5' 35MATCH LINE 64+00 "PR-A"MATCH LINE 56+50 "PR-A"MATCH LINE 71+00 "PR-A"MATCH LINE 64+00 "PR-A" LEGEND EXISTING Storm Manhole Gas Line Storm Inlets Sanitary Manhole Gas ValveGas Meter Sanitary Cleanout Water Line Water ValveFire Hydrant Sprinkler Electric Line Power Pole w/(Riser)Light & Power Pole Light & Power Pole w/Riser Water Meter Light PoleGuy Wire Electric Box Fiber Optic LineTelephone Line Telephone ManholeCable TV LineCable TV Box Telephone Riser Utility ManholeWood Fence Iron PinSign Flag PoleBushTree TrunkDeciduous TreeConiferous Tree Overhead Utility Line Wood Fence Wire FenceChainlink FenceIron FenceIrr. Valve Mailbox EROSION CONTROL SILT FENCE TEMPORARY INLET PROTECTION TEMPORARY RIPRAP CHECK DAM, MODIFIED EROSION CONTROL BLANKET 172+0073+0074+0075+0076+0077+0078+00(conc) (grvl) (conc) (asph)(asph) (asph) (grvl) 18" rcp 18" rcp App. Exist. R/WApp. PLApp. PL App. Exist. R/W RIVER RD.Line "PR-A"Line "PR-A" Exist. 50' R/W R/W 10" pvc 8" pvc 8" pvc Constr. Limits Constr. Limits Str. No. 58 Str. No. 59 Str. No. 53Str. No. 52 Str. No. 54 Str. No. 55 Str. No. 51 App. PL Str. No. 57+00+00+90+00Str. No. 56 1 1 1 1 +75Str. No. 61 +75+50+90760760 760 760 756 756 757 757758 758 759 759 7 5 9 755755 760756 756 757 757 758 758759 759 758759755 755 756 756 757 757758759+504' x 4' ScourStop Transition Mat 4' x 4' ScourStop Transition Mat 79+0080+0081+0082+0083+0085+0087+0018" rcp 18" rcp 18" rcp 18" rcp18" rcp (asph) (asph)(asph) (grvl) (grvl) App. Exist. R/W App. Exist . R / W App. Exist. R/W App. Exist. R/W App. Exist. R/W App. Exist. R / WApp. PL84+00RIVER RD. Line "PR-A" Constr. Limits Str. No. 63 Str. No. 62 Str. No. 65 Str. No. 64 Str. No. 72 Str. No. 68 Str. No. 69 Str. No. 67 Str. No. 66 Str. No. 70 Str. No. 71 Str. No. 63A+501 1 1 1 1 1 111 +90+00+90+10755 755 760 760 756 756 757 757 757 757 758 758 758 758 759 759 759 75 9 759 759 755 755 760 754754 756 756 757 757 758 758 759 761 1 4' x 4' ScourStop Transition Mat 4' x 4' ScourStop Transition Mat 4' x 4' ScourStop Transition Mat 4' x 4' ScourStop Transition Mat M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: EC LINE PR-A.dwgDATE/USER: 1/11/2017 1:10 PM / TybennettEROSION CONTROL LINE "PR-A" 1"=30' 1"=5' 36MATCH LINE 78+50 "PR-A"MATCH LINE 71+00 "PR-A"MATCH LINE 86+00 "PR-A"MATCH LINE 78+50 "PR-A" LEGEND EXISTING Storm Manhole Gas Line Storm Inlets Sanitary Manhole Gas ValveGas Meter Sanitary Cleanout Water Line Water ValveFire Hydrant Sprinkler Electric Line Power Pole w/(Riser)Light & Power Pole Light & Power Pole w/Riser Water Meter Light PoleGuy Wire Electric Box Fiber Optic LineTelephone Line Telephone ManholeCable TV LineCable TV Box Telephone Riser Utility ManholeWood Fence Iron PinSign Flag PoleBushTree TrunkDeciduous TreeConiferous Tree Overhead Utility Line Wood Fence Wire FenceChainlink FenceIron FenceIrr. Valve Mailbox EROSION CONTROL SILT FENCE TEMPORARY INLET PROTECTION TEMPORARY RIPRAP CHECK DAM, MODIFIED EROSION CONTROL BLANKET 1 87+0088+0089+0090+0091+0092+0018" r c p 18" r c p (grvl) App. Exist. R/W App. Exist. R/W App. E x i s t . R / W App. Exist. R/WApp. Exist. R/WApp. PL24" rcp 24" rcp 24" rcp 12" rcp??" rcp??" rcpRIVER RD. Line "PR-A" Constr. Limits Constr. Limits Str. No. 75 Str. No. 77 Str. No. 78 Str. No. 73 Str. No. 74 Str. No. 76 Silt Fence END PROJECT 90+55.23 "PR-A"+00+551 1 1 75 7 757 75 8 75 8 75 9 75 9 759 76 0 7 6 0 760 760 760 7 6 0 760 757 757 758 758 758 759 759 759 759 759 761 7 6 1 76176 1 760 758758 759 759 4' x 4 ' S c o u r S t o p T r a n s i t i o n M a t 4' x 8' ScourStop Transition Mat M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: EC LINE PR-A.dwgDATE/USER: 1/11/2017 1:10 PM / TybennettEROSION CONTROL LINE "PR-A" 1"=30' 1"=5' 37MATCH LINE 86+00 "PR-A" 10+00(conc)(grvl)App. PL Sec. 23, T18N, R4E Clay Township Hamilton County RIVER RD.Line "PR-A"50' R/WR/W R/W10" pvc10" pvc 10" pvc11+0012+0013+00Line "W-ENT " P.T. 13+47.36 "W-ENT" = O.P.O.T. 115.48 Lt., 61+65.08 "PR-A" BEGIN CONSTRUCTION P.O.C. 10+86.22 "W-EXIT" = O.P.O.C. 68.00 Lt., 10+86.22 "W-ENT"Line "W-EXIT" Constr. Limits Constr. Limits 0+001+002+00 3+00Line "B" P.O.T. 3+18.87 "B" = P.O.T. 61+51.55 "PR-A" Str. No. 81 Str. No. 82 Str. No. 79 Str. No. 83 App. PL R/W App. Exist. R/WApp. Exi s t . R / W App. E xi st. R / W App. Exist. R/ W App. Exist. R/ W App. PL App. Exi s t . R / W Constr. Limits Silt Fence 1 Str. No. 80 Str. No. 82A 1 1 1 Str. No. 32C Aqua-Swirl Structure LEGEND EXISTING Storm Manhole Gas Line Storm Inlets Sanitary Manhole Gas ValveGas Meter Sanitary Cleanout Water Line Water ValveFire Hydrant Sprinkler Electric Line Power Pole w/(Riser)Light & Power Pole Light & Power Pole w/Riser Water Meter Light PoleGuy Wire Electric Box Fiber Optic LineTelephone Line Telephone ManholeCable TV LineCable TV Box Telephone Riser Utility ManholeWood Fence Iron PinSign Flag PoleBushTree TrunkDeciduous TreeConiferous Tree Overhead Utility Line Wood Fence Wire FenceChainlink FenceIron FenceIrr. Valve Mailbox EROSION CONTROL SILT FENCE TEMPORARY INLET PROTECTION TEMPORARY RIPRAP CHECK DAM, MODIFIED EROSION CONTROL BLANKET 1 M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: EC-W-RAB.dwgDATE/USER: 1/11/2017 1:12 PM / TybennettEROSION CONTROL LINE "W-ENT" & "W-EXIT" 1"=30' 1"=5' 38 146th St.River Rd.OcB2 OcB2 We FxC3 FxC3 We St OcA Begin Project 44+79 "PR-A" End Project 90+55 "PR-A" M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: SWPP-ELEMENTS.dwgDATE/USER: 12/12/2016 8:46 AM / TbennettSTORM WATER POLLUTION PREVENTION CONSTRUCTION PLAN SOIL MAP 39 End Project 90+55 "PR-A" Begin Project 44+79 "PR-A"River Rd.146th St. M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: SWPP-ELEMENTS.dwgDATE/USER: 12/12/2016 8:46 AM / TbennettSTORM WATER POLLUTION PREVENTION CONSTRUCTION PLAN FLOOD MAPS 40 SWPP CONSTRUCTION PLAN ELEMENTS Metal pins or staples to secure the polythylene lining to the straw bales Polythylene lining (10 mil); the lining should extend over the straw bales Straw bales entrenched 4 inches into the soil Compacted soil material Metal pins or staples to secure the polythylene lining to the straw bales Wood or metal stakes to secure the straw bales (2 per straw bales) Straw bale (alternate materials or products may be used to provide structural containment) SECTION A-A Not to scaleL=10 FEETMetal pins or staples to secure the polythylene lining to the straw bales Wood or metal stakes to secure the straw bales (2 per straw bale) Straw bale (alternate materials or products may be used to provide structural containment. Alternative materials or products will require design modification. Polythylene lining (10 mil); the lining should extend over the straw bales.AA L = Inside Length W = Inside Width PLAN VIEW Not to scale W=10 FEET CONCRETE WASHOUT DETAIL Not to scale (5) The above table was provided for general information only to supplement information used in the Rule 5 permitting process. The contractor is responsible for material handling and spill mitigation procedures, including concrete washout. A1 - PLAN INDEX Sheet 1. A2 - PLAT NO. 1 Sheet 4 thru 6. A3 - NARRATIVE DESCRIBING THE NATURE AND PURPOSE OF THE PROJECT This project involves the reconstruction of River Road in Hamilton County from Community Drive to 146th street. A4 - VICINITY MAP Sheet 1. A5 - LEGAL DESCRIPTION Sheet 1. A6 - LOCATION OF LOTS AND SITE IMPROVEMENTS All improvements are shown on the plans. A7 - HYDROLOGIC UNIT CODE 05120201090010. A8 - NOTATION OF ANY STATE OR FEDERAL WATER QUALITY PERMITS Rule 5. A9 - SPECIFIC POINTS WHERE STORM WATER DISCHARGE WILL LEAVE SITE Sheet flow to new storm sewer which discharge into existing ditches. A10 - LOCATION AND NAME OF ALL WETLANDS, LAKES AND WATER COURSES ON AND ADJACENT TO SITE Tunis Garrand Drain and West Fork White River. A11 - IDENTIFICATION OF ALL RECEIVING WATERS West Fork White River. A12 - LOCATIONS OF POTENTIAL DISCHARGES TO GROUND WATER None. A13 - 100 YEAR FLOODPLAINS, FLOODWAYS, AND FLOODWAY FRINGES Flood areas are identified in FIRM maps on sheet 40. A14 - PRE-CONSTRUCTION AND POST-CONSTRUCTION ESTIMATE OF PEAK DISCHARGE (100 YR STORM) Q100 Pre = 58.26 cfs. Q100 Post = 64.95 cfs. Drainage being treated for Quantity and Quality thru the Legacy Development A15 - ADJACENT LAND USE, INCLUDING UPSTREAM WATERSHED Land use is mostly agricultural and residential. A16 - LOCATION AND APPROXIMATE BOUNDARIES OF ALL DISTURBED AREAS Reference the construction limits as shown on the plans. A17 - IDENTIFICATION OF EXISTING VEGETATIVE COVER Wooded land, farm land, trees, and lawn. A18 - SOILS MAP INCLUDING SOIL DESCRIPTIONS AND LIMITATIONS Soils map can be found on sheet 39. A19 - LOCATIONS, SIZE, AND DIMENSION OF STORM WATER SYSTEMS Storm sewer details are identified in the plans. A20 - PLANS FOR ANY OFF-SITE CONSTRUCTION ACTIVITIES ASSOCIATED WITH THIS PROJECT No off-site construction activities are anticipated to be associated with this project. A21 - LOCATIONS OF PROPOSED SOIL STOCKPILES, BORROW, AND/OR DISPOSAL AREAS Locations to be determined by Contractor and approved by the City of Carmel. A22 - EXISTING TOPOGRAPHY AT AN INTERVAL APPROPRIATE TO INDICATE DRAINAGE PATTERNS Existing contours are shown on the plans. A23 - PROPOSED FINAL TOPOGRAPHY AT AN INTERVAL APPROPRIATE TO INDICATE DRAINAGE PATTERNS Proposed contours are shown on the plans. See also cross sections. B1 - POTENTIAL POLLUTANT SOURCES ASSOCIATED WITH CONSTRUCTION ACTIVITIES There is a potential for pollutants associated with construction machinery including diesel fuel, hydraulic fluid, engine oils and lubricants, antifreeze, and other petroleum products. It is unavoidable for a small amount of these pollutants to contaminate soil in the grading and construction of the side. Sediment pollution from the site disturbing activities shall be remedied by erosion control measures (see following sections). B2 - SEQUENCE DESCRIBING STORM WATER QUALITY MEASURES IMPLEMENTATION RELATIVE TO LAND DISTURBING ACTIVITIES: 1. Prior to construction, site access, staging areas and contractor parking areas should be established in accordance with the Indiana Department of Transportation (INDOT) Standard Specifications, Standard Drawings and Guidelines. 2. Perimeter protection (silt fence) shall be placed as shown in the plans prior to any earthwork or other construction activity. Perimeter protection will remain in place and be maintained during all phases of construction. Construct or place concrete washout area. 3. Inlet protection shall be installed at all inlets (existing and proposed inlets once installed) and ditch checks placed at locations shown in plans. 4. Construct intersection improvement, including sidewalks, curb ramps and lighting. 5. Final contours shall be sodded, mulch seeded, or an erosion control fabric placed per contract drawings. 6. Temporary erosion control measures shall be removed after vegetation has been established. B3 - STABLE CONSTRUCTION ENTRANCE LOCATIONS AND SPECIFICATIONS The Contractor shall provide a stable construction entrance at the points where construction traffic will enter onto an existing road in accordance with INDOT Standard Specifications Section 205 "Temporary Erosion and Sediment Control" and Section 205.03 "General Requirements." The construction entrances shall be in accordance with details shown on this sheet. B4 - SEDIMENT CONTROL MEASURES FOR SHEET FLOW AREAS Silt fence and erosion control blanket locations are shown on the plans. Reference INDOT Standard Specifications and Standard Drawing. B5 - SEDIMENT CONTROL MEASURES FOR CONCENTRATED FLOW AREAS Riprap check dam locations are shown on the plans. Reference INDOT Standard Specifications Section 205 and Standard Drawing E 205-TECD-01 and E 205-TECD-02. B6 - STORM SEWER INLET PROTECTION MEASURES Inlet protection measures are shown on the plans. Reference INDOT Standard Specifications Section 205 and Standard Drawing E 205-TECI-01 and E 205-TECI-03. B7 - RUNOFF CONTROL MEASURES Runoff control measures are shown on the plans as outlined in B4 and B5 (above). B8 - STORM WATER OUTLET PROTECTION MEASURES Outlet protection measures are shown on the plans. B9 - GRADE STABILIZATION STRUCTURES No grade stabilization structures are planned for this project. B10 - LOCATION, DIMENSIONS, SPECIFICATIONS, AND DETAILS OF EACH STORM WATER QUALITY MEASURE All locations of planned measures are identified on the plans and listed in the Erosion Control Table. B11 - TEMPORARY SURFACE STABILIZATION METHODS APPROPRIATE FOR EACH SEASON Per INDOT Standard Specifications Section 205 "Temporary Erosion and Sediment Control" and Sections 205.04 "Temporary Surface Stabilization," the Contractor shall provide temporary seeding appropriate for the season as designated in the specification as temporary surface stabilization. Temporary seeding shall be placed on distrubed areas that are expected to be inactive for more than seven days, or as directed. INDOT Standard Specifications 100.04, 205.04, Standard Drawings, and guidelines address the temporary erosion and sediment control measures. B12 - PERMANENT SURFACE STABILIZATION Permanent seeding will be used on all disturbed earth. B13 - MATERIAL HANDLING AND SPILL PREVENTION See the Potential Storm Water Pollutants/Material Handling and Spill Prevention table (right). IDEM Emergency Response - 1-888-233-7745. B14 - MONITORING AND MAINTENANCE GUIDELINES Monitoring and Maintenance shall be within 24 hours of every 12 " or more rain event. B15 - EROSION AND SEDIMENT CONTROL MEASURES FOR INDIVIDUAL BUILDING LOTS Not applicable. C1 - PROPOSED POLLUTANTS AND SOURCES ASSOCIATED WITH PROPOSED LAND USE There is a potential for pollutants associated with vehicles including fuel, hydraulic fluid, engine oils and lubricants, antifreeze and other petroleum products. There are also the potential hazards of road salt, litter, etc. C2 - SEQUENCE DESCRIBING STORM WATER QUALITY MEASURES IMPLEMENTATION See Section B2. Permanent seeding will be placed when final grades are constructed and there is no other significant construction in the immediate area. C3 - DESCRIPTION OF PROPOSED POST-CONSTRUCTION STORM WATER QUALITY MEASURES Street sweeping, mechanical separators, and permanent seeding will be placed over disturbed area. Temporary silt fence and vegetation will filter pollutants until permanent vegetation is established. C4 - LOCATION, DIMENSIONS, SPECIFICATIONS, AND CONSTRUCTION DETAILS OF EACH STORM WATER QUALITY MEASURE Street sweeping occurs regularly as performed by the City of Carmel. A mechanical separator has been specified for each storm water outlet. Seeding locations and rip rap are shown on the plans. C5 - DESCRIPTION OF MAINTENANCE GUIDELINES FOR POST-CONSTRUCTION STORM WATER QUALITY MEASURES Ditches shall be kept free of litter and other debris. Grass shall be mowed regularly and inspected for dead spots, excessive erosion, etc. These areas shall be repaired immediately. Notes: 1.Storm Water Pollution Prevention (SWPP) checklist corresponds to the IDEM, Division of Soil Conservation Construction/Storm Water Pollution Prevention Plan Technical Review and Comment (Form 1) used in the Rule 5 permitting process. 2.The contractor shall use the SWPP checklist as a guide in preparing the SWPP plan required for Rule 5 procedures. 3.A site specific SWPP is to be submitted by the Contractor to the City of Carmel prior to earth moving if any adjustments to the plan herein are requested. 4.The location of staging area and concrete washout area are to be submitted by the contractor. 5.Four Mobilization and Demobilization for seeding (LSUM) are estimated. 6.Contractor is to maintain clean roadways of all tracked construction materials and sediment throughout the day and at the end of each work day. EROSION CONTROL TABLE OF QUANTITIES 3.0% NOT TO SCALE SECTION A-A TEMPORARY CONSTRUCTION ENTRANCE DETAIL Public road 24' (MIN.) 3.0% See notes for aggregate section Geotextile fabric100'50'3" #53 Stone on 5" #2 Stone 8" #2 Stone 44+94 to 61+00 LT 1606 69+00 to 71+00 LT 200 46644+94 to 49+60 RT 110055+00 to 66+00 RT 35587+00 to 90+55 RT CONSTRUCTION ENTRANCE 155 23 400 50+25 to 60+50 RT 5 20 1.0 80 63+00 to 65+10 RT 1 4 0.2 16 66+50 to 78+57 LT 9 36 1.8 144 67+75 to 87+00 RT 7 28 1.4 112 STRUCTURES 3727 47 47 104 5.2 416 47+55 to 50+00 RT.518 2874TOTALS26 6 340 58+00 LT 1 4 0.2 16 77+50 to 79+30 LT 440 81+70 to 89+00 LT 2 8 0.4 32 10+00 W-ENT 1 4 0.2 16 DITCHES 1916 M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: SWPP-ELEMENTS.dwgDATE/USER: 1/11/2017 3:31 PM / MmastersonSTORM WATER POLLUTION PREVENTION CONSTRUCTION PLAN ELEMENTS AND GENERAL NOTES 41 M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: SUMMARYTABLES.dwgDATE/USER: 1/10/2017 10:44 AM / MmastersonROAD SUMMARY TABLES 42 - - 7.2"45.6"7.2" 5'-0" 5.4" 6"D 6.6" 5.4" 7.2" 5.4"1'-6"Panel Style: D1-1d.ssi M.U.T.C.D.: 2009 Edition BORDER R=2.25" TH=0.75" CORNER RADIUS LEGEND/BORDER LETTER POSITIONS (X) SYMBOL BACKGROUND MOUNTING WIDTH x HGHT. BORDER WIDTH SIGN NUMBER SERIES/SIZELENGTH X Y HTWID TYPE: COLOR: TYPE: COLOR: ROT D1-1d(1) 5'-0" x 1'-6" Ground 0" 0.75" Letter locations are panel edge to lower left corner White/White Reflective Green Reflective R 7.2 i 12.2 v 13.9 e 18.6 r 23 25.3 R 31.3 d 36 32.4 D 2000 6/4.5 AR_Type D 45.6 5.4 6 9315 8.65"84.7"8.65" 8'-6" 6" 6"D 6" 5.4" 7.2" 5.4"1'-6"Panel Style: D1-1d.ssi M.U.T.C.D.: 2009 Edition BORDER R=2.25" TH=0.75" CORNER RADIUS LEGEND/BORDER LETTER POSITIONS (X) BACKGROUND MOUNTING WIDTH x HGHT. BORDER WIDTH SIGN NUMBER SERIES/SIZELENGTH TYPE: COLOR: TYPE: COLOR: D1-1d(2) 8'-6" x 1'-6" Ground 0" 0.75" Letter locations are panel edge to lower left corner White/White Reflective Green Reflective C 8.7 h 13.9 e 18.4 r 22.8 r 25.8 y 28.3 32.8 C 38.8 r 44.1 e 46.8 e 51 k 55.3 59.2 B 65.2 l 70.2 v 71.8 d 76.6 71.5 D 2000 6/4.5 2.9"42.2"2.9" 4'-0" 2" 4"C 2"0'-8"Panel Style: W16-8P.ssi M.U.T.C.D.: 2009 Edition BORDER R=1.5" TH=0.38" CORNER RADIUS LEGEND/BORDER LETTER POSITIONS (X) BACKGROUND MOUNTING WIDTH x HGHT. BORDER WIDTH SIGN NUMBER SERIES/SIZELENGTH TYPE: COLOR: TYPE: COLOR: W16-8P(1) 4'-0" x 0'-8" Ground 0" 0.38" Letter locations are panel edge to lower left corner Black/Black Reflective Yellow Reflective C 2.9 h 5.9 e 8.5 r 11 r 12.8 y 14.3 16.8 C 20.8 r 23.7 e 25.4 e 27.8 k 30.4 32.5 B 36.5 l 39.4 v 40.4 d 43 42.2 C 2000 4/3 2.4"19.2"2.4" 2'-0" 2" 4"C 2"0'-8"Panel Style: W16-8P.ssi M.U.T.C.D.: 2009 Edition BORDER R=1.5" TH=0.38" CORNER RADIUS LEGEND/BORDER LETTER POSITIONS (X) BACKGROUND MOUNTING WIDTH x HGHT. BORDER WIDTH SIGN NUMBER SERIES/SIZELENGTH TYPE: COLOR: TYPE: COLOR: W16-8P(2) 2'-0" x 0'-8" Ground 0" 0.38" Letter locations are panel edge to lower left corner Black/Black Reflective Yellow Reflective R 2.4 i 5.3 v 6.3 e 8.9 r 11.5 12.8 R 16.8 d 19.5 19.2 C 2000 4/3 SYMBOL X Y HTWIDROT AR_Type D 86.2 5.4 6 9315 M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE OFFSETCOVERUP STREAMDOWN STREAMFTINCHES LFT LFT ELEV. ELEV. YRS. CYS CYS SYS TON TON LFT EA. TYPE SLOPE EA. TYPESLOPE EA. 10 45+92 PR-A X 12 EXISTING MANHOLE11 45+92 PR-A X 12 INLET M-10 16 750.01 2.6 745.38 745.19 1 4.41012 45+92 PR-A X 12 INLET J-10 60 750.12 1.7 746.49 745.89 1 18.91113 47+55 PR-A X 12 INLET M-10 46 749.14 2.8 744.16 743.93 1 6.3 1OUTLET TO DITCH14 47+55 PR-A X 12 INLET M-10 46 749.01 1.7 745.35 744.89 1 14.51315 47+61 PR-A X 12 INLET J-10 3 749.15 1.4 745.52 745.49 1 0.81316 47+61 PR-A X 12 INLET J-10 3 749.01 1.4 745.38 745.35 1 0.81417 48+37 PR-A X 27 EXISTING INLETNO WORK REQUIRED18 49+00 PR-A X 12 INLET M-10 33 750.33 5.5 743.92 743.75 1 7.5 1OUTLET TO DITCH19 49+00 PR-A X 12 INLET J-10 44 750.17 1.8 746.54 746.10 1 10.01820 49+50 PR-A X 53"X34" RC ELLIPTICAL PIPE 69 N/A 1.4 745.70 745.02 1 98.2221 51+00 PR-A X 12 INLET M-10 39 753.53 7.5 745.20 745.00 1 11.7 1OUTLET TO DITCH22 51+00 PR-A X 12 INLET J-10 44 753.37 1.4 749.74 749.30 1 12.22123 51+42 PR-A X 18 EXISTING MANHOLE17 NO WORK REQUIRED24 55+38 PR-A X 18 EXISTING MANHOLE23 NO WORK REQUIRED25 58+50 PR-A1 X 12 INLET M-10 51 755.99 9.0 746.25 746.00 1 18.8 1OUTLET TO DITCH26 58+50 PR-A1 X 12 INLET J-10 44 755.83 752.20 751.76 1 14.4251.827 60+50 PR-A1 X 12 INLET J-10 5 754.79 751.16 751.11 1 1.4291.428 60+50 PR-A1 X 12 INLET A w/R-4342 11 753.36 751.35 751.11 1 3.229 R-4342 CASTING3.029 60+58 PR-A1 X 12 INLET M-10 56 754.79 751.11 750.55 1 18.4311.830 60+83 PR-A1 X 24 MANHOLE C-4 220 754.75 746.53 746.00 1 50.4 1OUTLET TO DITCH6.831 60+75 PR-A1 X 12 INLET M-10 28 754.76 750.55 750.27 1 9.9302.032 62+65 PR-A2 X 24 MANHOLE C-4 92 756.20 5.1 747.52 747.13 1 99.832A32A 1+54 B X 24 MANHOLE C-4 2 755.7 5.3 747.65 747.63 1 2.23032A 1+54 B X 12 HDPE PIPE 4 7.0 747.13 747.11 1 3.732B & 32C32B 1+59 B X 24 MANHOLE C-4 135 755.7 5.8 747.09 746.53 1 146.43032C 1+57 BX12 AQUASWIRL AS-6 4 756.5 7.7 747.11 747.09 1 4.132B33 64+77 PR-A2 X 12 INLET J-10 5 752.39 1.4 748.76 748.71 1 1.43534 STRUCTURE DELETED35 64+85 PR-A2 X 12 INLET M-10 27 752.39 1.7 748.71 748.44 1 8.53636 64+85 PR-A2X24MANHOLE C-4220 753.32 3.6 748.44 747.52 1 153.33237 64+85 PR-A2X12INLET M-1022 752.51 1.7 748.82 748.60 1 6.93638 64+93 PR-A2 X 12 INLET J-10 5 752.50 1.4 748.87 748.82 1 1.43739 65+72 PR-A X 10 EXISTING MANHOLENO WORK REQUIRED40 66+50 PR-A X 12 PIPE 23 N/A 1.2 751.34 750.64 1 5.2 1 4141 66+50 PR-A X 15 INLET M-10 27 753.64 0.6 750.64 750.42 1 6.84242 66+50 PR-A X 21 MANHOLE C-4 165 754.59 2.0 750.17 749.34 1 57.63642A 68+20 PR-A X 21 MANHOLE C-4 171 757.52 3.8 750.84 750.17 1 96.742TOTALCONNECT TO STR.SKEWSAFETY METAL END SECTIONGEOTEXTILESGRATED BOX END SECTIONSITE DESIGNATIONCLASS 1 RIPRAPSTRUCTURE DATALOCATIONREMARKSLENGTHRIM ELEVATIONPIPE TYPESTATIONSTRUCTURE BACKFILLRIGHTCROSSPIPE END SECTIONDESCRIPTIONSERVICE LIFEFLOWABLE BACKFILLMANHOLE, INLET, CATCH BASIN, OR SPECIALTY STRUCTUREFLOW LINEpHVIDEO INSPECTIONREVETMENT RIPRAPLEFTSIZEBACKFILL METHODSTRUCTUREDATA-1STRUCTURE NUMBERRECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE CITY OF CARMELSTRUCTURE DATA SHEETCHECKED: M.B.DRAWN: A.P.CHECKED: M.M.DESIGNED: M.M.BRIDGE FILEDESIGNATIONSURVEY BOOKSHEET43PROJECTCONTRACT16-ENG-80of5801/09/17 OFFSETCOVERUP STREAMDOWN STREAMFTINCHES LFT LFT ELEV. ELEV. YRS. CYS CYS SYS TON TON LFT EA. TYPE SLOPE EA. TYPESLOPE EA. 43 66+50 PR-A X 12 INLET J-10 22 753.64 0.7 750.65 750.42 1 5.04244 68+02 PR-A X 10 EXISTING MANHOLE39 NO WORK REQUIRED45 70+50 PR-A X 12 INLET A w/R-4342 23 755.28 2.0 753.30 753.07 1 8.146 CASTING R-434246 70+50 PR-A X 12 INLET M-10 22 756.57 1.7 752.90 752.68 1 6.94747 70+50 PR-A X 21 MANHOLE C-4 230 757.72 4.4 751.75 750.84 1 170.142A48 70+50 PR-A X 12 INLET M-10 27 756.57 1.7 752.90 752.63 1 8.54749 70+58 PR-A X 12 INLET J-10 5 756.58 1.4 752.95 752.90 1 1.44650 70+58 PR-A X 12 INLET J-10 5 756.58 1.4 752.95 752.90 1 1.44851 72+28 PR-A X 10 EXISTING MANHOLE44 NO WORK REQUIRED52 73+00 PR-A X 12 INLET J-10 22 757.74 1.7 754.11 753.89 1 6.95353 73+00 PR-A X 15 MANHOLE C-4 250 758.70 3.8 753.25 752.00 1 130.64754 73+00 PR-A X 12 INLET J-10 27 757.74 1.7 754.11 753.84 1 8.55355 74+70 PR-A X 8 EXISTING MANHOLE51 NO WORK REQIRED56 75+00 PR-A X 12 PIPE 50 N/A 1.0 756.84 756.40 2 5.2 2UNDER PATH57 75+50 PR-A X 12 MANHOLE C-4 250 759.99 4.2 754.50 753.25 1 128.95358 75+50 PR-A X 12 INLET J-10 22 759.03 1.7 755.40 755.18 1 6.95759 75+50 PR-A X 12 INLET J-10 27 759.04 1.7 755.41 755.14 1 8.55760 77+22 PR-A X 8 EXISTING MANHOLE55 NO WORK REQIRED61 76+21 PR-A X 18 PIPE 34 N/A 1.0 756.19 756.07 2 5.4 2UNDER DRIVE61A 79+19 PR-A X 15 PIPE 30 N/A 1.0 757.72 757.60 2 3.9 2UNDER DRIVE61B 79+89 PR-A X 15 PIPE 30 N/A 1.0 757.44 757.32 2 3.9 2UNDER DRIVE62 81+03 PR-A X 18 MANHOLE C-4 759.36 754.72 754.58CONNECT TO EXISTING PIPE63 81+03 PR-A X 12 INLET M-10 15 759.40 2.3 755.77 755.62 1 4.06263A 80+65 PR-A X 12 INLET A w/R-4342 37 758.75 1.5 756.14 755.77 1 10.763 CASTING R-434264 82+25 PR-A X 12 INLET M-10 18 758.91 3.2 754.76 754.57 1 3.5 1OUTLET TO DITCH65 82+25 PR-A X 12 INLET J-10 52 758.91 1.5 755.28 754.76 1 15.06466 83+60 PR-AX12INLET M-1016 758.28 3.0 754.36 754.28 1 3.1 1OUTLET TO DITCH67 83+60 PR-AX12INLET M-1052 758.28 1.5 754.62 754.36 1 15.06668 86+66 PR-A X 12 INLET J-10 3 758.28 1.4 754.65 754.62 1 0.86669 86+66 PR-A X 12 INLET J-10 3 758.28 1.4 754.65 754.62 1 0.86770 84+04 PR-A X 18 INLET E-7 22 755.72 5.0 750.85 750.75 1 10.87171 84+06 PR-A X 24 EXISTING INLET73 NO WORK REQIRED72 84+50 PR-A X 12 INLET J-10 15 758.64 2.7 755.01 754.93 1 2.9 1OUTLET TO DITCH73 87+40 PR-A X 24 EXISTING MANHOLE74 ADJUST CASTING TO GRADETOTALSTRUCTUREDATA-1STRUCTURE NUMBERDESCRIPTIONSERVICE LIFESTATIONSTRUCTURE DATALOCATIONREMARKSLENGTHRIM ELEVATIONCONNECT TO STR.SKEWSAFETY METAL END SECTIONGEOTEXTILESGRATED BOX END SECTIONSITE DESIGNATIONPIPE END SECTIONVIDEO INSPECTIONREVETMENT RIPRAPSTRUCTURE BACKFILLPIPE TYPELEFTSIZEBACKFILL METHODRIGHTCROSSMANHOLE, INLET, CATCH BASIN, OR SPECIALTY STRUCTURECLASS 1 RIPRAPFLOWABLE BACKFILLFLOW LINEpHRECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE CITY OF CARMELSTRUCTURE DATA SHEETCHECKED: M.B.DRAWN: A.P.CHECKED: M.M.DESIGNED: M.M.BRIDGE FILEDESIGNATIONSURVEY BOOKSHEET44PROJECTCONTRACT16-ENG-80of5801/09/17 OFFSETCOVERUP STREAMDOWN STREAMFTINCHES LFT LFT ELEV. ELEV. YRS. CYS CYS SYS TON TON LFT EA. TYPE SLOPE EA. TYPESLOPE EA.74 89+31 PR-A X 24 EXISTING INLET75 NO WORK REQUIRED75 89+85 PR-A X 24 EXISTING INLET76 NO WORK REQUIRED76 91+56 PR-A X 24 FURNISH TYPE 3 CASTINGFURNISH AND ADJUST CASTING TO GRADE77 91+56 PR-A X 12 FURNISH TYPE 2 CASTING76 FURNISH AND ADJUST CASTING TO GRADE78 91+56 PR-A X 12 EXISTING INLET77 NO WORK REQUIRED79 10+72 W-ENT X 10 EXISTING MANHOLENO WORK REQUIRED80 12+06 W-EXIT X 12 INLET J-10 3 751.77 0.6 749.11 749.08 1 0.58181 12+00 W-EXIT X 12 INLET M-10 38 751.76 0.6 749.08 748.85 1 4.4 1OUTLET TO DITCH82 12+00 W-ENT X 12 INLET M-10 37 751.81 0.6 749.19 748.97 1 4.6 1OUTLET TO DITCH82A 12+06 W-ENT X 12 INLET J-10 3 751.82 0.6 749.22 749.19 1 0.58283 12+68 W-ENT X 10 EXISTING MANHOLE79 ADJUST CASTING TO GRADETOTAL1482.5STRUCTURE NUMBERDESCRIPTIONSERVICE LIFESTATIONSTRUCTURE DATALOCATIONREMARKSLENGTHRIM ELEVATIONPIPE TYPELEFTSIZEBACKFILL METHODCONNECT TO STR.SKEWSAFETY METAL END SECTIONGEOTEXTILESGRATED BOX END SECTIONSITE DESIGNATIONCLASS 1 RIPRAPFLOWABLE BACKFILLFLOW LINEpHPIPE END SECTIONVIDEO INSPECTIONREVETMENT RIPRAPSTRUCTURE BACKFILLRIGHTCROSSMANHOLE, INLET, CATCH BASIN, OR SPECIALTY STRUCTURERECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE CITY OF CARMELSTRUCTURE DATA SHEETCHECKED: M.B.DRAWN: A.P.CHECKED: M.M.DESIGNED: M.M.BRIDGE FILEDESIGNATIONSURVEY BOOKSHEET45PROJECTCONTRACT16-ENG-80of5801/09/17 4"6"LFT LFT SYS CYS TONS %(Y/N) LFTCYS TONS LEFT44+94 PR-A747.4045+92 PR-A746.89 N 11 745.3845+92 PR-A746.8947+55 PR-A746.02 N 13 744.1647+61 PR-A746.03 N 15 745.5249+00 PR-A747.2149+00 PR-A747.21 N 18 743.9251+00 PR-A750.4151+00 PR-A750.41 N 21 745.20HP54+51 PR-A754.82HP54+51 PR-A754.8258+50 PR-A1752.87 N 25 746.2558+50 PR-A1752.8760+75 PR-A1751.64 N 31 750.5560+75 PR-A1751.64 N 31 750.55HP61+17 PR-A1751.73HP61+17 PR-A1751.7312+06 W-ENT749.39 N 82A 749.2212+00 W-ENT749.36 N 82 749.1910+88 W-ENT749.5810+86 W-EXIT749.4812+00 W-EXIT749.25 N 81 749.0812+06 W-EXIT749.28 N80 749.11HP62+77 PR-A2750.91HP62+77 PR-A2750.9164+77 PR-A2749.27 N 33 748.7664+85 PR-A2749.27 N 35 748.7166+50 PR-A750.6466+50 PR-A750.81 N 41 750.64HP69+09 PR-A753.95HP69+09 PR-A753.9570+50 PR-A753.45 N 46 752.9070+58 PR-A753.46 N 49 752.9573+00 PR-A754.6273+00 PR-A754.62 N 52 754.1175+50 PR-A755.9175+50 PR-A755.91 N58 755.40HP78+96 PR-A757.42HP78+96 PR-A757.4281+03 PR-A756.28 N 63 755.7781+03 PR-A756.2882+25 PR-A755.79 N 64 754.7682+25 PR-A755.7986+66 PR-A755.16 N 66 754.360.831.211.310.200.200.684330 3680.5 415.7122 103.7 11.7135 114.8 13.0346 294.1 33.2207 176.0 19.913.5242 205.7 23.2250 212.5 24.0241200165259141 119.9220.2 24.9TOTALS35139922542179112114204.9 23.1170.0 19.2140.3 15.8152.2 17.295.2 10.896.9 10.9339.2 38.3191.3 21.635.7 4.0200 170.0 19.2298.4 33.7163 138.6 15.6139 118.2 13.383.3 9.498HMA for UnderdrainsOutlet Pipe RequiredType 4 PipeOUTLET PIPEOutside RightOutside LeftOutlet Protector No. ___Special GradeFlow Line Elevation @ Underdrain Pipe LimitB Borrow for Structure BackfillMedian LeftOutlet Protector Type45 Degree Elbows Required (1 or 2)Underdrain Pipe LimitsLocationConnect Underdrain Pipe to Structure No. ___Median RightGeotextile for UnderdrainsStructure Invert ElevationConnect Outlet Pipe to Structure No. ___Aggregate for UnderdrainsDitch Flow Line Elevation at Outlet ProtectorUNDERDRAIN TABLE6" Outlet PipeOutlet StationOutlet ElevationOutlet at Outlet Protector No. ___HMA for UnderdrainsRemarksStructure Invert ElevationOUTLET PROTECTORSUNDERDRAIN PIPERECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE CITY OF CARMELUNDERDRAIN TABLECHECKED: M.B.DRAWN: M.A.M.CHECKED: M.B.DESIGNED: M.A.M.BRIDGE FILEDESIGNATIONSURVEY BOOKSHEET46PROJECTCONTRACT16‐ENG‐80of5801/09/17 4"6"LFT LFT SYS CYS TONS %(Y/N) LFTCYS TONS LEFT83+66 PR-A755.16 N 68 754.6584+50 PR-A755.5284+50 PR-A755.52 N 72 755.01HP87+82 PR-A756.39RIGHT44+94 PR-A747.9245+92 PR-A747.00 N 12 746.4945+92 PR-A747.0047+55 PR-A745.89 N 14 745.3547+61 PR-A745.89 N 16 745.3849+00 PR-A747.0549+00 PR-A747.05 N 19 746.5451+00 PR-A750.2551+00 PR-A750.25 N 22 749.74HP54+51 PR-A754.66HP54+51 PR-A754.6658+50 PR-A752.71 N 26 752.2058+50 PR-A752.7160+50 PR-A751.67 N 27 751.1660+58 PR-A751.67 N 29 751.11HP61+94 S-ENT-O753.40HP61+94 S-ENT-O753.4064+85 PR-A2749.39 N 37 748.8264+93 PR-A2749.38 N38 748.8766+50 PR-A750.8266+50 PR-A750.82 N43 750.65HP69+09 PR-A753.95HP69+09 PR-A753.9570+50 PR-A753.45N48 752.9070+58 PR-A753.46N50 752.9573+00 PR-A754.6273+00 PR-A754.62N54 754.1175+50 PR-A755.9275+50 PR-A755.92N59 755.41HP78+96 PR-A757.60HP78+96 PR-A757.6082+25 PR-A755.79N65 755.2882+25 PR-A755.7983+60 PR-A755.16N67 754.6283+66 PR-A755.16 N69 754.65HP87+82 PR-A758.690+00 B753.541+54 B750.78 Y 2 12 1+54 B 750.66 32A 747.133+58 B753.541+54 B750.78 Y 2 12 1+54 B 750.66 32A 747.13UNDERDRAIN TABLE6" Outlet PipeOutlet StationOutlet ElevationOutlet at Outlet Protector No. ___HMA for UnderdrainsRemarksStructure Invert ElevationOUTLET PROTECTORSUNDERDRAIN PIPEUnderdrain Pipe LimitsLocationConnect Underdrain Pipe to Structure No. ___Median RightGeotextile for UnderdrainsStructure Invert ElevationConnect Outlet Pipe to Structure No. ___Aggregate for UnderdrainsDitch Flow Line Elevation at Outlet ProtectorOUTLET PIPEOutside RightOutside LeftOutlet Protector No. ___Special GradeFlow Line Elevation @ Underdrain Pipe LimitB Borrow for Structure BackfillMedian LeftOutlet Protector Type45 Degree Elbows Required (1 or 2)71.4 8.184HMA for UnderdrainsOutlet Pipe RequiredType 4 Pipe332 282.2 31.998 83.3 9.4163 138.6 15.6118.2 13.329.5170.0 19.2298.4 33.7339.2 38.315.1220.2 24.9119.9 13.5170.0 19.2103.7 11.7261.023.2TOTALS139200351399200122307133.5157259141242250 212.5205.724.0346 294.1 33.2329 279.7 31.6135 114.8 13.0416 353.6 39.9154 130.9 14.8204 173.4 19.65028 4273.8 482.70.921.21RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE CITY OF CARMELUNDERDRAIN TABLECHECKED: M.B.DRAWN: M.A.M.CHECKED: M.B.DESIGNED: M.A.M.BRIDGE FILEDESIGNATIONSURVEY BOOKSHEET47PROJECTCONTRACT16‐ENG‐80of5801/09/17 59+0060+0061+0062+0063+00Line "PR-A" Line "PR-A"R/WR/WConstr. Limits 10" p v c P.T. = 59+55.79 "PR-A1" Constr. Limits Constr. Limits Constr. Limits RIVER RD. RIVER RD. P.T. 13+47.36 "W-ENT" = O.P.O.C. 18.00 Rt., 1+96.60 "B"Line "W-ENT"Line "W-EXIT"R/W50' R/W Constr. Limits App. PLApp. PLApp. PLApp . PL 10" pvc10" p vc App. Exist. R/W App. Exist. R/W App. Exist. R/W 1+002+003+00 0+00Line "B" P.O.C. 3+18.87 "B" = P.O.T. 61+51.55 "PR-A" Line "PR-A 1 "64+00Line "PR-A2" R/ W FUTURE LANES AND PATH Proposed Path/Drainage E s m n t . Indianapolis Water Co. Easement 45' R/W "PR-A 1 "35' R/WR/WP.O.T. 61+38.33 "PR-A1" = P.O.C. 2+54.03 "B" P.O.T. 62+37.94 "PR-A2" = P.O.C. 0+62.48 "B" P.O.T. 14+01.41 "W-EXIT" = P.O.C. 1+49.14 "B"CHERRY CREEK BLVD.App. Ex is t . R /WApp. Ex ist. R/W LEGEND 4-1/c No. 4 COPPER IN PLASTIC DUCT IN 2" GALVANIZED CONDUIT PROPOSED HANDHOLE PROPOSED STREET LIGHT POLE ASSEMBLY (30' POLE WITH 8' MAST ARM) PROPOSED EXISTING Existing Gas Main Existing Water Main Existing Cable Line Existing Telephone Line Existing Electric Line Existing Overhead Utility SERVICE POINT PROPOSED WATER LINE 2 ~ 4" PVC Conduits. See Technical Specifications) 5' Typ.5' Typ. 4-1/c No. 4 COPPER IN PLASTIC DUCT IN TRENCH NOTE: See City of Carmel Standard Drawing 10-45B for Light Standard Details 10-45A for Light Foundation Detail 10-42 & 43 for Service Point/Wiring 1 ~ 3/4" Conduit (See Technical Specifications) 60+60 "PR-A1" 36' 61+14 "PR-A1" 37' 63+17 "PR-A2" 34' 62+65 "PR-A2" 40' 12+84 "W-ENT" 24' 13+70 "W-EXIT" 28' 60+56 "PR-A1" 53' M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: LIGHTING PLAN.dwgDATE/USER: 12/23/2016 2:46 PM / MmastersonLIGHTING DETAILS 1"=20' 48 59+0060+0061+0062+0063+00(conc) (grvl) Falcon Nest II LLC Falcon Nest II LLC THE O V E R L O O K AT TH E L E G A C Y Line "PR-A" Line "PR-A"R/WR/WConstr. Limits 26 K 15 15 15 K K K K 26 16 16 14 14 C2 C2 15 15 18 18 15 L 26 26 P P K K 26 10" p v c P.T. = 59+55.79 "PR-A1" Constr. Limits Constr. Limits 15 18 15 Constr. Limits 15 RIVER RD. RIVER RD. Falcon Nest II LLC P.T. 13+47.36 "W-ENT" = O.P.O.C. 18.00 Rt., 1+96.60 "B"Line "W-ENT"Line "W-EXIT"2618 18 P R/W50' R/W Constr. Limits App. PLApp. PLApp. PLApp. P L 10" pvc10" pvc App. Exist. R/W App. Exist. R/W App. Exist. R/W 1+002+003+0 0 0+00Line "B" P.O.C. 3+18.87 "B" = P.O.T. 61+51.55 "PR-A" Line "PR-A 1 "64+00Line "PR-A2" P 18 P P P K K R/ W FUTURE LANES AND PATH F Proposed Path/Drainage E s m n t .App. Ex is t . R/W Indianapolis Water Co. Easement 45' R/W "PR-A 1 " 45' R/W "PR-A1"35' R/WR/WP.O.T. 61+38.33 "PR-A1" = P.O.C. 2+54.03 "B" P.O.T. 62+37.94 "PR-A2" = P.O.C. 0+62.48 "B" P.O.T. 14+01.41 "W-EXIT" = P.O.C. 1+49.14 "B"CHERRY CREEK BLVD.Handhole #4 60+94 "PR-A" Handhole #6 62+55 "PR-A" Handhole #5 60+94 "PR-A"App. Ex is t . R/W INSTALL 101 LFT 12" D.I. PIPE 12" CONNECTION REMOVE & RETURN HYDRANT INSTALL (1) 12 x 12 MJ TEE (1) 12" MJ PLUG INSTALL (1) 12" GATE VALVE (1) 12" x 12" MJ TEE (1) 12" MJ PLUG (1) 12" x 6" REDUCER (1) HYDRANT ASSEMBLY 2 ~ 4" PVC Conduits. See Technical Specifications) INSTALL 165 LFT 12" D.I. PIPE PROPOSED LEGEND NOTES 1.CONTRACTOR TO FIELD VERIFY EXISTING WATER MAIN FOR SIZE,TYPE & LOCATION AT ALL CONNECTION & DISCONNECT LOCATIONS. 2.CONTRACTOR TO VERIFY EXISTING ELEVATION AT HYDRANT LOCATION BEFORE INSTALLING HYDRANT ASSEMBLY. 3.VALVE KEY EXTENSIONS ARE TO BE USED FOR ANY VALVE KEY BELOW 4' FROM FINISHED GRADE. 4.CONTRACTOR TO DEFLECT PIPE AND USE MJ BENDS AS NECESSARY OR AS DIRECTED BY C.W.U. PERSONNEL TO STAY ON PROPOSED ALIGNMENT AND AVOID EXISTING AND PROPOSED STRUCTURES, PIPES AND UTILITIES. 5.54" IS THE MINIMUM COVER FOR ALL WATER LINES FROM PROPOSED GRADE. ANY ALTERATIONS TO COVER MUST BE EITHER APPROVED BY CARMEL WATER UTILITY. 6. UTILITIES SHOWN PER FIELD SURVEY. THE CONTRACTOR SHALL EXPOSE AND VERIFY ALL WATER UTILITY CONNECTIONS AND CROSSINGS PRIOR TO ANY CONSTRUCTION, AND REPORT ANY DISCREPANCIES TO CARMEL WATER UTILITY. 7.CONTRACTOR TO VERIFY ELEVATIONS OF WATER MAIN RELOCATIONS, SO NOT TO CONFLICT WITH ROAD PROJECT IMPROVEMENTS. Water Main Reducer Complete Hydrant Assembly Gate Valve Tee MJ Plug Thrust Block (See Typical Sheet for Additional Details) Mill and Overlay with WedgeR Curb & Gutter Type II15 Sod26 Full Depth Asphalt PavementK Concrete SidewalkF Perpendicular Curb Ramp Curb & Gutter Type III18 HMA SidewalkP P C PCCP for Approaches, 9" on Subgrade Treatment Type II C2 PCCP, 7" with D-1 Contraction Joints at 15' Max. Spacing on 10" Compacted Aggregate No. 53 Base on Subgrade Treatment Type IB Concrete Curb14 Modified Roll Curb16 Mill and OverlayR1 Mulched Seeding, U27 M.A.M. 16-ENG-80 58 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SHEETS of PROJECT HORIZONTAL SCALECITY OF CARMEL RIVER ROAD RECONSTRUCTION M.B. T.B. M.A.M. 1-9-17 VERTICAL SCALE DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: WATER MAIN PLANS.dwgDATE/USER: 12/23/2016 12:41 PM / TbennettWATER MAIN EXTENSION PLANS 1"=20' 49 D.E.B. D.E.B. ℄℄℄℄Center of Round-about Grading Plan50BScale: 1"= 10'-0"NORTH0'5'10'20'R.A.I.16-ENG-8058RECOMMENDEDFOR APPROVALLANDSCAPE ARCHITECTDATEDESIGNED:CHECKED:DRAWN:CHECKED:SHEETSofPROJECTHORIZONTAL SCALECITY OF CARMELRIVER ROAD RECONSTRUCTIONK.R.A.L.B.S.VERTICAL SCALElandscape architecture & planningStutz Building / 212 W. 10th Street, Suite B435 / Indianapolis, IN 46202phone: (317) 955-9960 fax: (317) 955-9961REMENSCHNEIDER ASSOCIATES, INC.All designs indicated by this drawing were created for use on this project, and are owned by and the property of Remenschneider Associates Inc. None of suchdesigns or ideas shall be used by any person, firm or corporation without the written permission of the landscape architects. All written dimensions take precedenceover scaled dimensions. Contractors shall verify all dimensions and conditions on site. Remenschneider Associated Incorporated must be notified of any variations.KENNETH J. REMENSCHNEIDER 01/11/17As NotedN/ACenter of Round-about Layout Plan50AScale: 1"= 10'-0"NORTH0'5'10'20'50CENTER OF ROUND-ABOUTLAYOUT AND GRADING PLANS CK1TD1QB1PA1GT1NS1PA1NS1QB1PA1GT1GD1CK1QI1GT2PA1GD1LT1QB1LT1PA1BN1TD1QR1GT1GDBN1QB2GB4BN2QI1PA1QI1LT1CO1GD2QI1TD1GD1BN1Landscape Plan51AScale: 1"= 20'-0"NORTH0'10'20'40'Landscape Plan51BScale: 1"= 20'-0"NORTH0'10'20'40'MATCHLINER.A.I.16-ENG-8058RECOMMENDEDFOR APPROVALLANDSCAPE ARCHITECTDATEDESIGNED:CHECKED:DRAWN:CHECKED:SHEETSofPROJECTHORIZONTAL SCALECITY OF CARMELRIVER ROAD RECONSTRUCTIONK.R.A.L.B.S.VERTICAL SCALElandscape architecture & planningStutz Building / 212 W. 10th Street, Suite B435 / Indianapolis, IN 46202phone: (317) 955-9960 fax: (317) 955-9961REMENSCHNEIDER ASSOCIATES, INC.All designs indicated by this drawing were created for use on this project, and are owned by and the property of Remenschneider Associates Inc. None of suchdesigns or ideas shall be used by any person, firm or corporation without the written permission of the landscape architects. All written dimensions take precedenceover scaled dimensions. Contractors shall verify all dimensions and conditions on site. Remenschneider Associated Incorporated must be notified of any variations.KENNETH J. REMENSCHNEIDER 01/11/17As NotedN/AMATCHLINEMATCHLINE MATCHLINELANDSCAPING MUST BE PLANTED ACCORDING TO THE DETAILS ON SHEET 58 - SEE PLANTING DETAILSLANDSCAPING MUST BE PLANTED ACCORDING TO THE DETAILS ON SHEET 58 - SEE PLANTING DETAILS51LANDSCAPE PLANTING PLANS NS2CK2PA1QB1BN1TD1QB1PA1PA1BN1GD1NS2TD2NS3TD1GB4GD1GB4GB4NF17AH44LK13RG23SA61LK21LB20RG42EP12NF15R.A.I.16-ENG-8058RECOMMENDEDFOR APPROVALLANDSCAPE ARCHITECTDATEDESIGNED:CHECKED:DRAWN:CHECKED:SHEETSofPROJECTHORIZONTAL SCALECITY OF CARMELRIVER ROAD RECONSTRUCTIONK.R.A.L.B.S.VERTICAL SCALElandscape architecture & planningStutz Building / 212 W. 10th Street, Suite B435 / Indianapolis, IN 46202phone: (317) 955-9960 fax: (317) 955-9961REMENSCHNEIDER ASSOCIATES, INC.All designs indicated by this drawing were created for use on this project, and are owned by and the property of Remenschneider Associates Inc. None of suchdesigns or ideas shall be used by any person, firm or corporation without the written permission of the landscape architects. All written dimensions take precedenceover scaled dimensions. Contractors shall verify all dimensions and conditions on site. Remenschneider Associated Incorporated must be notified of any variations.KENNETH J. REMENSCHNEIDER 01/11/17As NotedN/AMATCHLINELandscape Plan52BScale: 1"= 20'-0"40'20'10'0'Landscape Plan52AScale: 1"= 10'-0"NORTH20'10'5'0'NORTHLANDSCAPING MUST BE PLANTED ACCORDING TO THE DETAILS ON SHEET 58 - SEE PLANTING DETAILS52LANDSCAPE PLANTING PLANS LB15SA42NF26AH45LK11LK16RG26AG6NF65SA79LB14BK10LB18LK16LK17RG27SA49NF26AH45PV8BK10LB14SA64NF59SA99SA73BK10LB14PV8CV296SA73NF63SA84PV8Landscape Plan53AScale: 1"= 10'-0"NORTH0'5'10'20'R.A.I.16-ENG-8058RECOMMENDEDFOR APPROVALLANDSCAPE ARCHITECTDATEDESIGNED:CHECKED:DRAWN:CHECKED:SHEETSofPROJECTHORIZONTAL SCALECITY OF CARMELRIVER ROAD RECONSTRUCTIONK.R.A.L.B.S.VERTICAL SCALElandscape architecture & planningStutz Building / 212 W. 10th Street, Suite B435 / Indianapolis, IN 46202phone: (317) 955-9960 fax: (317) 955-9961REMENSCHNEIDER ASSOCIATES, INC.All designs indicated by this drawing were created for use on this project, and are owned by and the property of Remenschneider Associates Inc. None of suchdesigns or ideas shall be used by any person, firm or corporation without the written permission of the landscape architects. All written dimensions take precedenceover scaled dimensions. Contractors shall verify all dimensions and conditions on site. Remenschneider Associated Incorporated must be notified of any variations.KENNETH J. REMENSCHNEIDER 01/11/17As NotedN/AMATCHLINELANDSCAPING MUST BE PLANTED ACCORDING TO THE DETAILS ON SHEET 58 - SEE PLANTING DETAILS53LANDSCAPE PLANTING PLANS NF26AH45LK11NS2PA1TD1BN2QB1LT1QI2CK 1P A 1CO1NS1LT1GB4CK1PA1BN1QB2BN1PA1GT1QR1QR1GT1TD1CK1GD1GD1CO1TD1CK1GD1QR1CO2CO3Landscape Plan54AScale: 1"= 20'-0"Landscape Plan54BScale: 1"= 20'-0"MATCHLINEMATCHLINE NORTH40'20'10'0'NORTH40'20'10'0'R.A.I.16-ENG-8058RECOMMENDEDFOR APPROVALLANDSCAPE ARCHITECTDATEDESIGNED:CHECKED:DRAWN:CHECKED:SHEETSofPROJECTHORIZONTAL SCALECITY OF CARMELRIVER ROAD RECONSTRUCTIONK.R.A.L.B.S.VERTICAL SCALElandscape architecture & planningStutz Building / 212 W. 10th Street, Suite B435 / Indianapolis, IN 46202phone: (317) 955-9960 fax: (317) 955-9961REMENSCHNEIDER ASSOCIATES, INC.All designs indicated by this drawing were created for use on this project, and are owned by and the property of Remenschneider Associates Inc. None of suchdesigns or ideas shall be used by any person, firm or corporation without the written permission of the landscape architects. All written dimensions take precedenceover scaled dimensions. Contractors shall verify all dimensions and conditions on site. Remenschneider Associated Incorporated must be notified of any variations.KENNETH J. REMENSCHNEIDER 01/11/17As NotedN/AMATCHLINEMAT C H LI N ELANDSCAPING MUST BE PLANTED ACCORDING TO THE DETAILS ON SHEET 58 - SEE PLANTING DETAILSLANDSCAPING MUST BE PLANTED ACCORDING TO THE DETAILS ON SHEET 58 - SEE PLANTING DETAILS54LANDSCAPE PLANTING PLANS TD1QI1QR1LT1BN1CO1GD1GT2GD1NS1QB1NS1QB1NS1GT1GB1QI1GT1PA1QB1LT1TD1CO2TD1QB1TD1QI1GT1QI1QR1QR1CK1QR1CK1PA1LT1CK1Landscape Plan55AScale: 1"= 20'-0"NORTHLandscape Plan55BScale: 1"= 20'-0"NORTH40'20'10'0'40'20'10'0'MATC H L I N EMATCHLINE MATCHLINE MATCHLINER.A.I.16-ENG-8058RECOMMENDEDFOR APPROVALLANDSCAPE ARCHITECTDATEDESIGNED:CHECKED:DRAWN:CHECKED:SHEETSofPROJECTHORIZONTAL SCALECITY OF CARMELRIVER ROAD RECONSTRUCTIONK.R.A.L.B.S.VERTICAL SCALElandscape architecture & planningStutz Building / 212 W. 10th Street, Suite B435 / Indianapolis, IN 46202phone: (317) 955-9960 fax: (317) 955-9961REMENSCHNEIDER ASSOCIATES, INC.All designs indicated by this drawing were created for use on this project, and are owned by and the property of Remenschneider Associates Inc. None of suchdesigns or ideas shall be used by any person, firm or corporation without the written permission of the landscape architects. All written dimensions take precedenceover scaled dimensions. Contractors shall verify all dimensions and conditions on site. Remenschneider Associated Incorporated must be notified of any variations.KENNETH J. REMENSCHNEIDER 01/11/17As NotedN/ALANDSCAPING MUST BE PLANTED ACCORDING TO THE DETAILS ON SHEET 58 - SEE PLANTING DETAILSLANDSCAPING MUST BE PLANTED ACCORDING TO THE DETAILS ON SHEET 58 - SEE PLANTING DETAILS55LANDSCAPE PLANTING PLANS CO1GD1GB2LT1NS1QI1GB3Landscape Plan56AScale: 1"= 20'-0"NORTH40'20'10'0'MATCHLINER.A.I.16-ENG-8058RECOMMENDEDFOR APPROVALLANDSCAPE ARCHITECTDATEDESIGNED:CHECKED:DRAWN:CHECKED:SHEETSofPROJECTHORIZONTAL SCALECITY OF CARMELRIVER ROAD RECONSTRUCTIONK.R.A.L.B.S.VERTICAL SCALElandscape architecture & planningStutz Building / 212 W. 10th Street, Suite B435 / Indianapolis, IN 46202phone: (317) 955-9960 fax: (317) 955-9961REMENSCHNEIDER ASSOCIATES, INC.All designs indicated by this drawing were created for use on this project, and are owned by and the property of Remenschneider Associates Inc. None of suchdesigns or ideas shall be used by any person, firm or corporation without the written permission of the landscape architects. All written dimensions take precedenceover scaled dimensions. Contractors shall verify all dimensions and conditions on site. Remenschneider Associated Incorporated must be notified of any variations.KENNETH J. REMENSCHNEIDER 01/11/17As NotedN/ALANDSCAPING MUST BE PLANTED ACCORDING TO THE DETAILS ON SHEET 58 - SEE PLANTING DETAILS56LANDSCAPE PLANTING PLANS R.A.I.16-ENG-8058RECOMMENDEDFOR APPROVALLANDSCAPE ARCHITECTDATEDESIGNED:CHECKED:DRAWN:CHECKED:SHEETSofPROJECTHORIZONTAL SCALECITY OF CARMELRIVER ROAD RECONSTRUCTIONK.R.A.L.B.S.VERTICAL SCALElandscape architecture & planningStutz Building / 212 W. 10th Street, Suite B435 / Indianapolis, IN 46202phone: (317) 955-9960 fax: (317) 955-9961REMENSCHNEIDER ASSOCIATES, INC.All designs indicated by this drawing were created for use on this project, and are owned by and the property of Remenschneider Associates Inc. None of suchdesigns or ideas shall be used by any person, firm or corporation without the written permission of the landscape architects. All written dimensions take precedenceover scaled dimensions. Contractors shall verify all dimensions and conditions on site. Remenschneider Associated Incorporated must be notified of any variations.KENNETH J. REMENSCHNEIDER 01/11/17As NotedN/ARetaining Wall Detail57ENot to ScaleLimestone Cap Detail57CNot to ScaleTypical Masonry Wall Layout Plan 57AScale: 1/4"=1'-0"Typical Wall and Pier Elevation57DNot to ScaleMasonry Pier57BNot to ScaleVeneer Wall Tie Detail57GNot to ScaleStep Foundation Detail56FScale: Not To Scale57MASONRY WALL DETAILS Shrub Planting Detail58BNot to ScaleTree Planting Detail58ANot to ScaleNOTES: - SEE PROJECT MANUAL TECHNICAL SPECIFICATIONS FOR COMPLETE LANDSCAPE PLANTING & PLANTING SOIL PREPARATIONS - ALL PLANTING AREAS SHALL RECEIVE 3" DEPTH OF SHREDDED HARDWOOD MULCH, FREE OF CORN COBS, WOOD CHIPS, GRAVEL AND CRUSHED STONE. - MULCH SHALL NOT BE HELD IN PLACE BY PLASTIC NET, OR SPRAYING OF ANY BINDER MATERIAL OR ASPHALT EMULSION - CONTRACTOR SHALL WARRANTY PLANT MATERIAL FOR A PERIOD OF ONE YEAR FROM PROJECT COMPLETION - PLANTS SHALL BE WATERED BY THE CONTRACTOR AFTER INSTALLATION PER PROJECT WATERING SCHEDULE. LOSSES DUE TO LACK OF WATER DURING WARRANTY PERIOD BECOME LIABILITY OF CONTRACTOR. - WEEDING, LANDSCAPE MAINTENANCE AND WATERING TO BE THE CONTRACTOR'S RESPONSIBILITY DURING CONSTRUCTION - TOPSOIL SHALL CONFORM TO TECHNICAL SPECIFICATIONS FREE OF HEAVY CLAY, ROCKS AND DIRT CLODS OVER 1 INCH IN DIAMETER AS WELL AS CONTAIN 3%-5% ORGANIC MATTER - CONTRACTOR SHALL STAKE INDIVIDUAL TREE AND SHRUB LOCATIONS AND OUTLINE AREAS FOR MULTIPLE HERBACEOUS PLANTINGS, ADJUST LOCATIONS WHEN REQUESTED AND OBTAIN PROJECT LANDSCAPE ARCHITECT'S ACCEPTANCE PRIOR TO PLANTING. - ALL PLANT ID TAGS SHALL BE REMOVED AFTER INSTALLATION.Plug & Perennial Spacing Detail58DNot to ScaleR.A.I.16-ENG-8058RECOMMENDEDFOR APPROVALLANDSCAPE ARCHITECTDATEDESIGNED:CHECKED:DRAWN:CHECKED:SHEETSofPROJECTHORIZONTAL SCALECITY OF CARMELRIVER ROAD RECONSTRUCTIONK.R.A.L.B.S.VERTICAL SCALElandscape architecture & planningStutz Building / 212 W. 10th Street, Suite B435 / Indianapolis, IN 46202phone: (317) 955-9960 fax: (317) 955-9961REMENSCHNEIDER ASSOCIATES, INC.All designs indicated by this drawing were created for use on this project, and are owned by and the property of Remenschneider Associates Inc. None of suchdesigns or ideas shall be used by any person, firm or corporation without the written permission of the landscape architects. All written dimensions take precedenceover scaled dimensions. Contractors shall verify all dimensions and conditions on site. Remenschneider Associated Incorporated must be notified of any variations.KENNETH J. REMENSCHNEIDER 01/11/17As NotedN/ATREE & SHRUB SCHEDULEKEYNOTEBOTANICAL NAMECOMMON NAMEAPPROX. QTY.SIZESPACINGNOTESAmalanchier x grandifolia 'Autumn Brilliance'Autumn Brilliance Serviceberry61.5" CaliperSee PlanSingle-StemBetula nigraRiver Birch112.5" CaliperSee PlanSingle-StemBuxus x koreana 'Green Velvet''Green Velvet' Boxwood3018"-24" Height3' o.c..Celtis occidentalis 'Chicagoland'Chicagoland Hackberry122.5" CaliperSee Plan.Cladrastis kentukeaYellowwood102.5" CaliperSee Plan.Ginkgo biloba 'Autumn Gold'Autumn Gold Ginkgo262.5" CaliperSee Plan.Gleditsia triacanthos inermis 'Sky Cole'Thornless Honeylocust122.5" CaliperSee PlanInermisGymnoclanus dioicaKentucky Coffeetree122.5" CaliperSee PlanLiriodendron tulipiferaTuliptree92.5" CaliperSee Plan.Nyssa sylvatica 'Wildfire'Wildfire Black Gum162.5" CaliperSee Plan.Platanus x acerfoliaLondon Planetree142.5" CaliperSee Plan.Quercus bicolorSwamp White Oak142.5" CaliperSee Plan.Quercus imbricariaShingle Oak112.5" CaliperSee Plan.Quercus rubrumNorthern Red Oak82.5" CaliperSee Plan.Taxodium distichumCommon Baldcypress142.5" CaliperSee Plan.PERENNIAL & GROUNDCOVER SCHEDULEKEYNOTEBOTANICAL NAMECOMMON NAMEAPPROX. QTY.SIZESPACINGNOTESAmsonia hubrichtiiNarrow Leaf Blue Star1341 gallon2'-6" o.c.Carex vulpinoidiaFox Sedge296Plug; 2" pot1'-6" o.c.Echinacea purpurea 'Magnus'Magnus Purple Coneflower121 gallon2'-6" o.c.Leucanthemum x superbum 'Becky'Becky Shasta Daisy951 gallon2'-0" o.c.Liatris spicata 'Kobold'Kobold Gayfeather941 gallon2'-0" o.c.Nepeta x faassenii 'Walker's Low'Walker's Low Nepeta2711 gallon2'-6" o.c.Panicum virgatum 'Northwind'Northwind Switchgrass243 gallon3'-0" o.c.Rudbeckia fulgida 'Goldstrum'Goldstrum Black-eyed Susan1181 gallon2'-0" o.c.Sesleria autumnalisAutumn Moor Grass6241 gallon2'-0" o.c.LANDSCAPING MUST BEPLANTED ACCORDING TO THEDETAILS ON THIS SHEETStone Mulch Detail58CNot to Scale58PLANTING DETAILS DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CROSS SECTIONS.dwgDATE/USER: 1/10/2017 11:29 AM / MmastersonRECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALECITY OF CARMEL RIVER ROAD PHASE 2______VERTICAL SCALE CROSS SECTIONS SAMPLE LINE PLACEMENT 1"=30' . XS1M.A.M. 16-ENG-80 XS29 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE M.B. T.B. M.A.M. _____ ALL "PR-A" SAMPLE LINES ARE PERPENDICULAR TO "PR-A" ALIGNMENT AND ARE NOT SHOWN. RIVER RD. Line "PR-A" 10+8 8 11+50 12+00 12+58 12+95 57+8158+5059+0059+5060+0060+5060+7563+0063+3764+0064+5064+8565+4310+8 6 11+50 12+00 12+50 13+33 Line "PR-A" Line "B" Line "PR-A1 " Line "PR-A2" 1+24 0+76 0+000+301+752 + 2 5 2+70 3+15RIVER RD.CHERRY CREEK BLVD.Line "W-ENT"Line "W-EXIT" DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CROSS SECTIONS.dwgDATE/USER: 1/10/2017 11:29 AM / MmastersonRECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALECITY OF CARMEL RIVER ROAD PHASE 2______VERTICAL SCALE CROSS SECTIONS LINE "PR-A" 1"=5' 1"=5' XS2 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 M.A.M. 16-ENG-80 XS29 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE M.B. T.B. M.A.M. _____ 45+00 45+00 745 750 755 745 750 755 45+50 45+50 745 750 755 745 750 755 45+93 45+93 740 745 750 755 740 745 750 755 46+50 46+50 745 750 755 745 750 755 P.G.=751.504:14:1 P.G.=751.043:1 3:1 6:1 P.G.=750.643:1 3:1 5:1 P.G.=750.113:1 -1.5% 3:1 Ex. El. 751.37Ex. El. 750.67Ex. El. 750.22Ex. El. 749.79FILL CUT AREA = 15.0 AREA = 11.5 VOL. = 0 VOL. = 0 FILL CUT AREA = 36.6 AREA = 16.5 VOL. = 48 VOL. = 26 FILL CUT AREA = 48.1 AREA = 14.2 VOL. = 67 VOL. = 24 FILL CUT AREA = 42.8 AREA = 53.7 VOL. = 97 VOL. = 72 Ex. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WInv. Out = 746.49 Str. No. 12 Inv. In From Str. No. 12 = 745.89 Inv. Out = 745.38 Str. No. 11 Inv. In From Str. No. 11 = 745.22 Str. No. 10 12" 12" Conduit/Interduct Conduit/Interduct Conduit/Interduct Conduit/Interduct DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CROSS SECTIONS.dwgDATE/USER: 1/10/2017 11:29 AM / MmastersonRECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALECITY OF CARMEL RIVER ROAD PHASE 2______VERTICAL SCALE CROSS SECTIONS LINE "PR-A" 1"=5' 1"=5' XS3 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 M.A.M. 16-ENG-80 XS29 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE M.B. T.B. M.A.M. _____ 47+00 47+00 740 745 750 755 740 745 750 755 47+55 47+55 740 745 750 740 745 750 48+00 48+00 740 745 750 755 740 745 750 755 48+50 48+50 740 745 750 755 740 745 750 755 P.G.=749.693:1 -1.5% 3:1 P.G.=749.533:1 -1.5% 3:1 P.G.=749.642:1-1.5% 2.6:1 P.G.=750.032:13:1 3.0:1 Ex. El. 749.32Ex. El. 748.74Ex. El. 748.63Ex. El. 748.80FILL CUT AREA = 50.4 AREA = 54.0 VOL. = 86 VOL. = 100 FILL CUT AREA = 104.0 AREA = 24.9 VOL. = 157 VOL. = 80 FILL CUT AREA = 156.3 AREA = 17.5 VOL. = 217 VOL. = 35 FILL CUT AREA = 261.1 AREA = 4.4 VOL. = 386 VOL. = 20 Ex. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/W12" Inv. In From Str. No. 14 = 744.89 Inv. In From Str. No. 15 = 745.49 Inv. Out = 744.16 Str. No. 13 12" Inv. In From Str. No. 16 = 745.35 Inv. Out = 745.35 Str. No. 14 D.S.=743.93 Conduit/InterductConduit/Interduct Conduit/Interduct Conduit/Interduct Conduit/Interduct DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CROSS SECTIONS.dwgDATE/USER: 1/10/2017 11:29 AM / MmastersonRECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALECITY OF CARMEL RIVER ROAD PHASE 2______VERTICAL SCALE CROSS SECTIONS LINE "PR-A" 1"=5' 1"=5' XS4 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 M.A.M. 16-ENG-80 XS29 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE M.B. T.B. M.A.M. _____ 49+00 49+00 740 745 750 755 740 745 750 755 49+50 49+50 740 745 750 755 740 745 750 755 50+00 50+00 740 745 750 755 740 745 750 755 50+50 50+50 740 745 750 755 740 745 750 755 P.G.=750.692:1 3:1 2.7:1 P.G.=751.492:1 3:1 2.3:1 P.G.=752.293:1 3:1 2.5:1 P.G.=753.09752.57 3.0:1 3:1 Ex. El. 749.50Ex. El. 749.83Ex. El. 750.56Ex. El. 751.52FILL CUT AREA = 354.2 AREA = 0.0 VOL. = 570 VOL. = 4 FILL CUT AREA = 321.8 AREA = 0.0 VOL. = 625 VOL. = 0 FILL CUT AREA = 259.9 AREA = 0.0 VOL. = 541 VOL. = 0 FILL CUT AREA = 147.3 AREA = 16.9 VOL. = 381 VOL. = 16 Ex. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WInv. Out = 746.54 Str. No. 19 Inv. In From Str. No. 19 = 746.10 Inv. Out = 743.92 Str. No. 18 12" 12" D.S.=743.75 Str. No. 20 D.S.=745.02 U.S.=745.70 53" Conduit/Interduct Conduit/Interduct Conduit/Interduct Conduit/Interduct DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CROSS SECTIONS.dwgDATE/USER: 1/10/2017 11:29 AM / MmastersonRECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALECITY OF CARMEL RIVER ROAD PHASE 2______VERTICAL SCALE CROSS SECTIONS LINE "PR-A" 1"=5' 1"=5' XS5 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 M.A.M. 16-ENG-80 XS29 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE M.B. T.B. M.A.M. _____ 51+00 51+00 740 745 750 755 740 745 750 755 51+50 51+50 740 745 750 755 760 740 745 750 755 760 52+00 52+00 740 745 750 755 760 740 745 750 755 760 P.G.=753.89753.37 3.0:1 3:1 P.G.=754.69754.17 3.0:1 3:1 P.G.=755.49754.97 3.0:1 3:1 Ex. El. 752.59Ex. El. 753.50Ex. El. 754.39FILL CUT AREA = 97.8 AREA = 23.9 VOL. = 230 VOL. = 38 FILL CUT AREA = 133.3 AREA = 11.5 VOL. = 217 VOL. = 33 FILL CUT AREA = 119.9 AREA = 26.4 VOL. = 238 VOL. = 36 Ex. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WInv. Out = 749.74 Str. No. 22 12" Inv. In From Str. No. 22 = 749.30 Inv. Out = 745.20 Str. No. 21 12" D.S.=745.00 Conduit/Interduct Conduit/Interduct Conduit/Interduct DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CROSS SECTIONS.dwgDATE/USER: 1/10/2017 11:29 AM / MmastersonRECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALECITY OF CARMEL RIVER ROAD PHASE 2______VERTICAL SCALE CROSS SECTIONS LINE "PR-A" 1"=5' 1"=5' XS6 50 10 15 20 25 30 35 40 45 50 5551015202530354045505560657075 M.A.M. 16-ENG-80 XS29 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE M.B. T.B. M.A.M. _____ 80859095 50 10 15 20 25 30 35 40 45 50 555101520253035404550556065707580859095 52+50 52+50 740 745 750 755 760 740 745 750 755 760 53+00 53+00 740 745 750 755 760 740 745 750 755 760 53+50 53+50 740 745 750 755 760 740 745 750 755 760 P.G.=756.29755.37 3.0:1 -1.5%P.G.=757.09755.77 3.0:1 -1.5%P.G.=757.76756.17 3.0:1 -1.5%Ex. El. 755.34Ex. El. 756.13Ex. El. 756.54FILL CUT AREA = 97.6 AREA = 69.2 VOL. = 203 VOL. = 90 FILL CUT AREA = 68.8 AREA = 113.5 VOL. = 154 VOL. = 169 FILL CUT AREA = 64.5 AREA = 154.0 VOL. = 124 VOL. = 248 Ex. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WConduit/Interduct Conduit/Interduct Conduit/Interduct DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CROSS SECTIONS.dwgDATE/USER: 1/10/2017 11:29 AM / MmastersonRECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALECITY OF CARMEL RIVER ROAD PHASE 2______VERTICAL SCALE CROSS SECTIONS LINE "PR-A" 1"=5' 1"=5' XS7M.A.M. 16-ENG-80 XS29 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE M.B. T.B. M.A.M. _____ 50 10 15 20 25 30 35 40 455101520253035404550556065707580859095 50 10 15 20 25 30 35 40 455101520253035404550556065707580859095 100105 100105 54+00 54+00 740 745 750 755 760 740 745 750 755 760 54+50 54+50 740 745 750 755 760 740 745 750 755 760 55+00 55+00 740 745 750 755 760 740 745 750 755 760 P.G.=758.16756.57 3.1:1 -1.5%P.G.=758.30756.67 3.0:1 -1.5%P.G.=758.17756.47 3.0:1 -1.5%Ex. El. 756.81Ex. El. 756.88Ex. El. 756.96FILL CUT AREA = 88.8 AREA = 140.1 VOL. = 142 VOL. = 272 FILL CUT AREA = 111.5 AREA = 153.9 VOL. = 185 VOL. = 272 FILL CUT AREA = 97.2 AREA = 170.0 VOL. = 193 VOL. = 300 Ex. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WConduit/Interduct Conduit/Interduct Conduit/Interduct DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CROSS SECTIONS.dwgDATE/USER: 1/10/2017 11:29 AM / MmastersonRECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALECITY OF CARMEL RIVER ROAD PHASE 2______VERTICAL SCALE CROSS SECTIONS LINE "PR-A" 1"=5' 1"=5' XS8M.A.M. 16-ENG-80 XS29 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE M.B. T.B. M.A.M. _____ 50 10 15 20 25 30 35 40 455101520253035404550556065707580859095 50 10 15 20 25 30 35 40 455101520253035404550556065707580859095 100105 100105 55+50 55+50 740 745 750 755 760 740 745 750 755 760 56+00 56+00 740 745 750 755 760 740 745 750 755 760 56+50 56+50 740 745 750 755 760 740 745 750 755 760 P.G.=757.91756.27 3.0:1 -1.5%P.G.=757.65756.07 3.0:1 -1.5%P.G.=757.39755.87 3.0:1 -1.5%Ex. El. 757.25Ex. El. 757.40Ex. El. 757.47FILL CUT AREA = 53.8 AREA = 202.1 VOL. = 140 VOL. = 345 FILL CUT AREA = 38.4 AREA = 228.7 VOL. = 85 VOL. = 399 FILL CUT AREA = 27.5 AREA = 240.6 VOL. = 61 VOL. = 435 Ex. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WConduit/Interduct Conduit/Interduct Conduit/Interduct DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CROSS SECTIONS.dwgDATE/USER: 1/10/2017 11:29 AM / MmastersonRECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALECITY OF CARMEL RIVER ROAD PHASE 2______VERTICAL SCALE CROSS SECTIONS LINE "PR-A" 1"=5' 1"=5' XS9M.A.M. 16-ENG-80 XS29 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE M.B. T.B. M.A.M. _____ 50 10 15 20 25 30 35 40 455101520253035404550556065707580859095 50 10 15 20 25 30 35 40 455101520253035404550556065707580859095 100105 100105 57+00 57+00 740 745 750 755 760 740 745 750 755 760 57+50 57+50 740 745 750 755 760 740 745 750 755 760 P.G.=757.13755.67 3.0:1 -1.5%P.G.=756.87755.47 3.0:1 -1.5% 57+81 57+81 740 745 750 755 760 740 745 750 755 760 Ex. El. 757.42Ex. El. 757.39FILL CUT AREA = 22.3 AREA = 262.5 VOL. = 46 VOL. = 466 FILL CUT AREA = 15.2 AREA = 310.8 VOL. = 35 VOL. = 531P.G.=756.71755.35 3.0:1 -1.5% FILL CUT AREA = 12.0 AREA = 364.0 VOL. = 16 VOL. = 387 Ex. El. 757.33Ex. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WConduit/Interduct Conduit/Interduct Conduit/Interduct DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CROSS SECTIONS.dwgDATE/USER: 1/10/2017 11:29 AM / MmastersonRECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALECITY OF CARMEL RIVER ROAD PHASE 2______VERTICAL SCALE CROSS SECTIONS LINE "PR-A1" 1"=5' 1"=5' XS10M.A.M. 16-ENG-80 XS29 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE M.B. T.B. M.A.M. _____ 50 10 15 20 25 30 35 40 455101520253035404550556065707580859095 50 10 15 20 25 30 35 40 455101520253035404550556065707580859095 100105 100105 57+81 57+81 740 745 750 755 760 740 745 750 755 760 P.G.=756.71755.34 3.0:1 58+50 58+50 745 750 755 760 745 750 755 760 754.87P.G.=756.354:1 6:1 59+00 59+00 745 750 755 760 745 750 755 760 P.G.=756.09754.47 3.1:1 6:1 59+50 59+50 745 750 755 760 745 750 755 760 P.G.=755.83754.07 3.0:1 6:1 Ex. El. 757.32FILL CUT AREA = 11.6 AREA = 364.2 VOL. = 0 VOL. = 0 FILL CUT AREA = 12.2 AREA = 380.0 VOL. = 0 VOL. = 0 FILL CUT AREA = 6.5 AREA = 388.6 VOL. = 13 VOL. = 525 FILL CUT AREA = 0.0 AREA = 344.1 VOL. = 6 VOL. = 644 Ex. R/WEx. R/WEx. R/WEx. R/WEx. R/WStr. No. 30 746.10 Str. No. 30 746.21 Conduit/Interduct Conduit/Interduct Conduit/Interduct Conduit/Interduct Inv. Out = 752.20 Str. No. 26 Inv. In From Str. No. 26 = 751.76 Inv. Out = 746.25 Str. No. 25 12" 12" D.S.=746.00Str. No. 30 746.00 DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CROSS SECTIONS.dwgDATE/USER: 1/10/2017 11:29 AM / MmastersonRECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALECITY OF CARMEL RIVER ROAD PHASE 2______VERTICAL SCALE CROSS SECTIONS LINE "PR-A1" 1"=5' 1"=5' XS11M.A.M. 16-ENG-80 XS29 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE M.B. T.B. M.A.M. _____ 50 10 15 20 25 30 35 40 4551015202530354045505560657075808590 50 10 15 20 25 30 35 40 4551015202530354045505560657075808590 50 55 60 50 55 60 60+00 60+00 745 750 755 760 745 750 755 760 P.G.=755.57753.673:1 6:1 60+50 60+50 745 750 755 760 745 750 755 760 60+75 60+75 745 750 755 760 745 750 755 760 4:1 4:1 FILL CUT AREA = 0.0 AREA = 294.2 VOL. = 0 VOL. = 591 FILL CUT AREA = 0.0 AREA = 272.7 VOL. = 0 VOL. = 520 Ex. R/WEx. R/WEx. R/WStr. No. 30 746.33 Str. No. 30 746.45 Inv. Out = 751.16 Str. No. 27- Pr. El.=755.15- Pr. El.=755.18- Pr. El.=755.18- Pr. El.=755.0912" Inv. In From Str. No. 27 = 751.11 Inv. In From Str. No. 28 = 751.11 Inv. Out = 751.11 Str. No. 29 @ 60+58 Inv. Out = 751.35 Str. No. 28 12" Inv. In From Str. No. 32B = 746.53 Inv. In From Str. No. 31 = 750.27 Inv. Out = 746.53 Str. No. 30 @ 60+83 Inv. In From Str. No. 29 = 750.55 Inv. Out = 750.55 Str. No. 31 @ 60+75 Conduit/Interduct Conduit/Interduct Conduit/Interduct DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CROSS SECTIONS.dwgDATE/USER: 1/10/2017 11:29 AM / MmastersonRECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALECITY OF CARMEL RIVER ROAD PHASE 2______VERTICAL SCALE CROSS SECTIONS LINE "PR-A2" 1"=5' 1"=5' XS12 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 M.A.M. 16-ENG-80 XS29 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE M.B. T.B. M.A.M. _____ 63+00 63+00 745 750 755 760 745 750 755 760 4:1 4:1 63+37 63+37 745 750 755 760 745 750 755 760 P.G.=754.13753.04 4:1 64+00 64+00 745 750 755 760 745 750 755 760 752.79P.G.=753.424:1 Ex. El. 755.78Ex. El. 754.86Ex. El. 754.80FILL CUT AREA = 1.9 AREA = 142.5 VOL. = 0 VOL. = 0 FILL CUT AREA = 0.0 AREA = 141.5 VOL. = 2 VOL. = 331 Str. No. 36 747.67 Str. No. 36 747.82 Str. No. 36 748.09 - Pr. El.=754.52Conduit/Interduct Conduit/Interduct Conduit/Interduct - Pr. El.=754.39Pr. R/WPr. R/WPr. R/W DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CROSS SECTIONS.dwgDATE/USER: 1/10/2017 11:29 AM / MmastersonRECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALECITY OF CARMEL RIVER ROAD PHASE 2______VERTICAL SCALE CROSS SECTIONS LINE "PR-A2" 1"=5' 1"=5' XS13 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 M.A.M. 16-ENG-80 XS29 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE M.B. T.B. M.A.M. _____ 64+50 64+50 745 750 755 760 745 750 755 760 752.59P.G.=753.114:1 64+85 64+85 745 750 755 760 745 750 755 760 752.45P.G.=753.034:1 65+43 65+43 745 750 755 760 745 750 755 760 P.G.=753.144:1 4:1 Ex. El. 754.71Ex. El. 754.43Ex. El. 753.63FILL CUT AREA = 0.0 AREA = 185.3 VOL. = 0 VOL. = 303 FILL CUT AREA = 1.1 AREA = 164.5 VOL. = 1 VOL. = 227 FILL CUT AREA = 49.4 AREA = 52.0 VOL. = 54 VOL. = 232 Str. No. 36 748.29 Str. No. 42 749.63 Inv. In From Str. No. 38 = 748.82 Inv. Out = 748.82 Str. No. 37 Inv. In From Str. No. 42 = 749.34 Inv. In From Str. No. 37 = 748.60 Inv. In From Str. No. 35 = 748.44 Inv. Out = 748.44 Str. No. 36 Inv. In From Str. No. 33 = 748.71 Inv. Out = 748.71 Str. No. 35 12"12" Conduit/Interduct Conduit/Interduct Conduit/Interduct Pr. R/WPr. R/WPr. R/W DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CROSS SECTIONS.dwgDATE/USER: 1/10/2017 11:29 AM / MmastersonRECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALECITY OF CARMEL RIVER ROAD PHASE 2______VERTICAL SCALE CROSS SECTIONS LINE "PR-A" 1"=5' 1"=5' XS14 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 M.A.M. 16-ENG-80 XS29 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE M.B. T.B. M.A.M. _____ 65+43 65+43 745 750 755 760 745 750 755 760 66+00 66+00 745 750 755 745 750 755 66+50 66+50 745 750 755 745 750 755 67+00 67+00 750 755 760 750 755 760 4:1 4:1P.G.=753.563:1P.G.=754.17751.46 4:1P.G.=755.00751.66 4:1 Ex. El. 753.63Ex. El. 753.00Ex. El. 753.42Ex. El. 754.12Ex. R/WEx. R/WEx. R/WEx. R/WFILL CUT AREA = 49.4 AREA = 52.0 VOL. = 0 VOL. = 0 FILL CUT AREA = 139.1 AREA = 0.4 VOL. = 204 VOL. = 53 FILL CUT AREA = 165.7 AREA = 8.9 VOL. = 285 VOL. = 8 FILL CUT AREA = 150.1 AREA = 2.1 VOL. = 289 VOL. = 9 Str. No. 42 749.63 Str. No. 42 749.92 Inv. Out = 750.65 Str. No. 43 Inv. In From Str. No. 42A = 750.17 Inv. In From Str. No. 43 = 750.43 Inv. In From Str. No. 41 = 750.42 Inv. Out = 750.17 Str. No. 42 Inv. In From Str. No. 40 = 750.64 Inv. Out = 750.64 Str. No. 41 12"15"12"U.S.=751.34 P.G.=753.14Str. No. 42A 750.37 Conduit/Interduct Conduit/Interduct Conduit/Interduct Conduit/Interduct Pr. R/WPr. R/WPr. R/WPr. R/W DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CROSS SECTIONS.dwgDATE/USER: 1/10/2017 11:29 AM / MmastersonRECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALECITY OF CARMEL RIVER ROAD PHASE 2______VERTICAL SCALE CROSS SECTIONS LINE "PR-A" 1"=5' 1"=5' XS15 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 M.A.M. 16-ENG-80 XS29 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE M.B. T.B. M.A.M. _____ 67+50 67+50 750 755 760 750 755 760 68+00 68+00 750 755 760 750 755 760 68+50 68+50 750 755 760 750 755 760 69+00 69+00 750 755 760 750 755 760 69+50 69+50 750 755 760 750 755 760 P.G.=756.00751.86 4:1 755.38 P.G.=756.84755.23 755.78 P.G.=757.37755.69 756.18 P.G.=757.58755.84 755.88 P.G.=757.48755.99 Ex. El. 754.99Ex. El. 756.06Ex. El. 757.07Ex. El. 757.82Ex. El. 758.31Ex. R/WEx. R/WEx. R/WEx. R/WEx. R/WFILL CUT AREA = 114.4 AREA = 17.3 VOL. = 238 VOL. = 16 FILL CUT AREA = 70.1 AREA = 8.2 VOL. = 167 VOL. = 22 FILL CUT AREA = 34.5 AREA = 37.1 VOL. = 95 VOL. = 43 FILL CUT AREA = 20.3 AREA = 71.6 VOL. = 50 VOL. = 100 FILL CUT AREA = 9.0 AREA = 97.1 VOL. = 27 VOL. = 156 Str. No. 47 750.96 Str. No. 47 751.16 Str. No. 47 751.35 Str. No. 42A 750.76 Str. No. 42A 750.56 Conduit/Interduct Conduit/Interduct Conduit/Interduct Conduit/Interduct Conduit/Interduct Pr. R/WPr. R/WPr. R/WPr. R/WPr. R/W DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CROSS SECTIONS.dwgDATE/USER: 1/10/2017 11:29 AM / MmastersonRECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALECITY OF CARMEL RIVER ROAD PHASE 2______VERTICAL SCALE CROSS SECTIONS LINE "PR-A" 1"=5' 1"=5' XS16 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 M.A.M. 16-ENG-80 XS29 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE M.B. T.B. M.A.M. _____ 70+00 70+00 750 755 760 750 755 760 70+50 70+50 750 755 760 750 755 760 71+00 71+00 750 755 760 750 755 760 71+50 71+50 750 755 760 750 755 760 72+00 72+00 750 755 760 750 755 760 755.58 P.G.=757.22756.14 755.28 P.G.=757.09756.29 755.88 P.G.=757.22756.44 756.48 P.G.=757.48756.59 757.08 P.G.=757.74756.74 Ex. El. 758.76Ex. El. 758.86Ex. El. 758.87Ex. El. 758.90Ex. El. 759.15Ex. R/WEx. R/WEx. R/WEx. R/WEx. R/WFILL CUT AREA = 0.3 AREA = 107.1 VOL. = 9 VOL. = 189 FILL CUT AREA = 0.2 AREA = 109.7 VOL. = 0 VOL. = 201 FILL CUT AREA = 0.4 AREA = 87.8 VOL. = 1 VOL. = 183 FILL CUT AREA = 2.4 AREA = 86.1 VOL. = 3 VOL. = 161 FILL CUT AREA = 4.1 AREA = 71.0 VOL. = 6 VOL. = 145 Str. No. 47 751.55 Str. No. 53 752.25 Str. No. 53 752.50 Str. No. 53 752.75 Inv. Out = 753.32 Str. No. 45 Inv. In From Str. No. 49 = 752.90 Inv. In From Str. No. 45 = 753.07 Inv. Out = 752.90 Str. No. 46 Inv. In From Str. No. 53 = 752.00 Inv. In From Str. No. 48 = 752.63 Inv. In From Str. No. 46 = 752.68 Inv. Out = 751.75 Str. No. 47 Inv. In From Str. No. 50 = 752.90 Inv. Out = 752.90 Str. No. 48 12"12"12" Conduit/Interduct Conduit/Interduct Conduit/Interduct Conduit/Interduct Conduit/Interduct Pr. R/WPr. R/WPr. R/WPr. R/WPr. R/W DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CROSS SECTIONS.dwgDATE/USER: 1/10/2017 11:29 AM / MmastersonRECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALECITY OF CARMEL RIVER ROAD PHASE 2______VERTICAL SCALE CROSS SECTIONS LINE "PR-A" 1"=5' 1"=5' XS17 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 M.A.M. 16-ENG-80 XS29 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE M.B. T.B. M.A.M. _____ 72+50 72+50 750 755 760 750 755 760 73+00 73+00 750 755 760 750 755 760 73+50 73+50 750 755 760 765 750 755 760 765 74+00 74+00 750 755 760 765 750 755 760 765 757.68 P.G.=758.00756.94 757.64 P.G.=758.26757.14 757.44 P.G.=758.52757.34 757.24 P.G.=758.78757.54 Ex. El. 759.58Ex. El. 759.84Ex. El. 760.11Ex. El. 760.30Ex. R/WEx. R/WEx. R/WEx. R/WFILL CUT AREA = 2.8 AREA = 78.4 VOL. = 6 VOL. = 138 FILL CUT AREA = 2.0 AREA = 78.7 VOL. = 4 VOL. = 145 FILL CUT AREA = 2.5 AREA = 76.7 VOL. = 4 VOL. = 144 FILL CUT AREA = 7.3 AREA = 69.9 VOL. = 9 VOL. = 136 Str. No. 53 753.00 Inv. Out = 754.11 Str. No. 52 Inv. In From Str. No. 54 = 753.84 Inv. In From Str. No. 52 = 753.89 Inv. In From Str. No. 57 = 753.25 Inv. Out = 753.25 Str. No. 53 Inv. Out = 754.11 Str. No. 54 12"12" Str. No. 57 753.50 Str. No. 57 753.75 Conduit/Interduct Conduit/Interduct Conduit/Interduct Conduit/Interduct DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CROSS SECTIONS.dwgDATE/USER: 1/10/2017 11:29 AM / MmastersonRECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALECITY OF CARMEL RIVER ROAD PHASE 2______VERTICAL SCALE CROSS SECTIONS LINE "PR-A" 1"=5' 1"=5' XS18 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 M.A.M. 16-ENG-80 XS29 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE M.B. T.B. M.A.M. _____ 74+50 74+50 750 755 760 765 750 755 760 765 75+00 75+00 750 755 760 750 755 760 75+50 75+50 750 755 760 765 750 755 760 765 76+00 76+00 755 760 765 755 760 765 76+21 76+21 755 760 765 755 760 765 757.04 P.G.=759.04757.74P.G.=759.30757.94 756.38 758.14P.G.=759.564:1 3:1 756.20 758.34P.G.=759.825:1 3:1 P.G.=759.93758.42 -4.5%Ex. El. 760.19Ex. El. 759.87Ex. El. 759.67Ex. El. 759.58Ex. El. 759.58Ex. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WFILL CUT AREA = 19.1 AREA = 49.1 VOL. = 24 VOL. = 110 FILL CUT AREA = 45.4 AREA = 42.4 VOL. = 60 VOL. = 85 FILL CUT AREA = 49.6 AREA = 29.7 VOL. = 88 VOL. = 67 FILL CUT AREA = 63.0 AREA = 36.2 VOL. = 104 VOL. = 61 FILL CUT AREA = 55.7 AREA = 31.3 VOL. = 46 VOL. = 26 Inv. Out = 755.40 Str. No. 58 Inv. Out = 755.41 Str. No. 59 12"12" Str. No. 56 756.84 Str. No. 61 756.13 DRIVE LT. Str. No. 57 754.00 Str. No. 57 754.25 Inv. In From Str. No. 58 = 755.18 Inv. In From Str. No. 59 = 755.14 Inv. Out = 754.50 Str. No. 57 Conduit/Interduct Conduit/Interduct Conduit/Interduct Conduit/Interduct Conduit/Interduct DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CROSS SECTIONS.dwgDATE/USER: 1/10/2017 11:29 AM / MmastersonRECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALECITY OF CARMEL RIVER ROAD PHASE 2______VERTICAL SCALE CROSS SECTIONS LINE "PR-A" 1"=5' 1"=5' XS19 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 M.A.M. 16-ENG-80 XS29 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE M.B. T.B. M.A.M. _____ 77+00 77+00 755 760 765 755 760 765 77+50 77+50 750 755 760 765 750 755 760 765 78+00 78+00 750 755 760 765 750 755 760 765 78+57 78+57 750 755 760 765 750 755 760 765 755.84 758.54P.G.=760.346:1 3:1 758.34P.G.=760.60755.66 4:1 3:1 758.14P.G.=760.86755.48 3:1 3:1 757.91P.G.=761.15755.28 2:1 3:1 Ex. El. 760.05Ex. El. 760.16Ex. El. 760.05Ex. El. 759.91Ex. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WFILL CUT AREA = 127.1 AREA = 24.3 VOL. = 265 VOL. = 83 FILL CUT AREA = 134.9 AREA = 23.2 VOL. = 239 VOL. = 46 FILL CUT AREA = 141.6 AREA = 20.5 VOL. = 252 VOL. = 42 FILL CUT AREA = 150.1 AREA = 8.3 VOL. = 303 VOL. = 32 Conduit/Interduct Conduit/Interduct Conduit/Interduct Conduit/Interduct DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CROSS SECTIONS.dwgDATE/USER: 1/10/2017 11:29 AM / MmastersonRECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALECITY OF CARMEL RIVER ROAD PHASE 2______VERTICAL SCALE CROSS SECTIONS LINE "PR-A" 1"=5' 1"=5' XS20 50 10 15 20 25 30 35 40 45 50 55 60 6551015202530354045505560657075 M.A.M. 16-ENG-80 XS29 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE M.B. T.B. M.A.M. _____ 8085 50 10 15 20 25 30 35 40 45 50 55 60 65510152025303540455055606570758085 78+97 78+97 755 760 765 755 760 765 79+58 79+58 750 755 760 750 755 760 80+00 80+00 755 760 765 755 760 765 758.18 757.75P.G.=761.243:1 4:1 3:1 3:1P.G.=761.03757.51 3:1 6:1P.G.=760.78757.34 3:1 3:1 4:1 Ex. El. 759.74Ex. El. 759.41Ex. El. 759.25Ex. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WFILL CUT AREA = 124.1 AREA = 24.3 VOL. = 200 VOL. = 25 FILL CUT AREA = 158.0 AREA = 0.2 VOL. = 147 VOL. = 11 FILL CUT AREA = 36.4 AREA = 17.5 VOL. = 23 VOL. = 6 Existing Pipe Existing Pipe Existing Pipe 79+20 79+20 755 760 755 760P.G.=761.21+1.4%4:1 -7.3% 79+89 79+89 755 760 765 755 760 765 P.G.=760.85+2.0%-4.2%4:1 Str. No. 61A 757.66 Existing Pipe Existing Pipe FILL CUT AREA = 74.9 AREA = 9.8 VOL. = 134 VOL. = 6 FILL CUT AREA = 52.4 AREA = 16.1 VOL. = 75 VOL. = 17 DRIVE RT. DRIVE LT. DRIVE RT. Str. No. 61B 757.38Ex. El. 759.29Ex. El. 759.56Conduit/Interduct Conduit/Interduct Conduit/Interduct Conduit/Interduct Conduit/Interduct DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CROSS SECTIONS.dwgDATE/USER: 1/10/2017 11:29 AM / MmastersonRECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALECITY OF CARMEL RIVER ROAD PHASE 2______VERTICAL SCALE CROSS SECTIONS LINE "PR-A" 1"=5' 1"=5' XS21M.A.M. 16-ENG-80 XS29 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE M.B. T.B. M.A.M. _____ 50 10 15 20 25 30 35 40 45 50 55 60 65510152025303540455055606570758085 50 10 15 20 25 30 35 40 45 50 55 60 65510152025303540455055606570758085 80+65 80+65 750 755 760 765 750 755 760 765 81+03 81+03 750 755 760 750 755 760 81+50 81+50 750 755 760 750 755 760 82+00 82+00 750 755 760 750 755 760 82+25 82+25 750 755 760 750 755 760 757.08P.G.=760.393:1 3:1P.G.=760.16756.93 4:1 3:1 3:1 4:1 P.G.=759.88756.74 4:1 3:1 3:1 4:1 P.G.=759.58756.54 3:1 3:1 3:1P.G.=759.43756.44 3:1 3:1 3:1 Ex. El. 759.10Ex. El. 759.09Ex. El. 758.79Ex. El. 758.57Ex. El. 758.51Ex. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WFILL CUT AREA = 116.6 AREA = 14.4 VOL. = 184 VOL. = 38 FILL CUT AREA = 126.9 AREA = 9.3 VOL. = 171 VOL. = 17 FILL CUT AREA = 138.5 AREA = 5.5 VOL. = 232 VOL. = 13 FILL CUT AREA = 150.0 AREA = 2.5 VOL. = 267 VOL. = 7 FILL CUT AREA = 156.2 AREA = 1.3 VOL. = 142 VOL. = 2 Inv. In From Str. No. 63A = 755.77 Inv. Out = 755.77 Str. No. 63 Inv. In From Str. No. 63 = 755.62 Str. No. 62 12" Inv. Out = 755.28 Str. No. 65 Inv. In From Str. No. 65 = 754.76 Inv. Out = 754.76 Str. No. 64 12"12" D.S.=754.58 Existing Pipe Existing Pipe Inv. Out = 756.14 Str. No. 63A Conduit/Interduct Conduit/Interduct Conduit/Interduct Conduit/Interduct Conduit/Interduct DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CROSS SECTIONS.dwgDATE/USER: 1/10/2017 11:29 AM / MmastersonRECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALECITY OF CARMEL RIVER ROAD PHASE 2______VERTICAL SCALE CROSS SECTIONS LINE "PR-A" 1"=5' 1"=5' XS22M.A.M. 16-ENG-80 XS29 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE M.B. T.B. M.A.M. _____ 50 10 15 20 25 30 35 40 45 50 55 60 65510152025303540455055606570758085 50 10 15 20 25 30 35 40 45 50 55 60 65510152025303540455055606570758085 83+00 83+00 750 755 760 765 750 755 760 765 83+60 83+60 750 755 760 765 750 755 760 765 84+04 84+04 750 755 760 765 750 755 760 765 84+50 84+50 750 755 760 765 750 755 760 765 P.G.=758.98756.14 3:1 3:1 3:1P.G.=758.80755.90 3:1 3:1 3:1 3:1 3:1 3:1P.G.=759.16756.29 3:1 3:1 3:13:1 Ex. El. 758.51Ex. El. 758.80Ex. El. 759.08Ex. El. 758.43Ex. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WFILL CUT AREA = 112.5 AREA = 11.3 VOL. = 373 VOL. = 17 FILL CUT AREA = 100.5 AREA = 16.6 VOL. = 237 VOL. = 31 FILL CUT AREA = 119.7 AREA = 14.5 VOL. = 179 VOL. = 25 FILL CUT AREA = 101.8 AREA = 15.1 VOL. = 189 VOL. = 25 Inv. Out = 750.85 Str. No. 70 18"Existing 18" Inv. Out = 755.01 Str. No. 72 12" D.S.=754.93 Existing Pipe D.S.=754.28 Inv. In From Str. No. 67 = 754.36 Inv. In From Str. No. 68 = 754.62 Inv. Out = 754.36 Str. No. 66 Inv. In From Str. No. 69 = 754.62 Inv. Out = 754.62 Str. No. 67 12"12" D.S.=750.75 Conduit/Interduct Conduit/Interduct Conduit/Interduct Conduit/Interduct DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CROSS SECTIONS.dwgDATE/USER: 1/10/2017 11:29 AM / MmastersonRECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALECITY OF CARMEL RIVER ROAD PHASE 2______VERTICAL SCALE CROSS SECTIONS LINE "PR-A" 1"=5' 1"=5' XS23M.A.M. 16-ENG-80 XS29 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE M.B. T.B. M.A.M. _____ 50 10 15 20 25 30 35 40 45 50 55 60 65510152025303540455055606570758085 50 10 15 20 25 30 35 40 45 50 55 60 65510152025303540455055606570758085 85+00 85+00 750 755 760 750 755 760 85+50 85+50 750 755 760 750 755 760 86+00 86+00 750 755 760 750 755 760 86+50 86+50 750 755 760 750 755 760 87+00 87+00 750 755 760 750 755 760 P.G.=759.46756.68P.G.=759.46756.68 3:1 3:1 3:13:1 3:1 3:13:1 P.G.=759.76757.07 4:1 3:1 3:13:1 P.G.=760.06757.46 3:1 3:1 3:13:1 P.G.=760.36757.85 3:1 3:1 3:13:1 P.G.=760.664:1 3:1 3:1 4:1 Ex. El. 759.44Ex. El. 759.79Ex. El. 760.07Ex. El. 760.38Ex. El. 760.60Ex. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WFILL CUT AREA = 94.5 AREA = 12.1 VOL. = 182 VOL. = 26 FILL CUT AREA = 77.1 AREA = 9.6 VOL. = 159 VOL. = 20 FILL CUT AREA = 73.0 AREA = 8.1 VOL. = 139 VOL. = 16 FILL CUT AREA = 69.4 AREA = 10.5 VOL. = 131 VOL. = 17 FILL CUT AREA = 49.4 AREA = 10.2 VOL. = 109 VOL. = 19 Existing Pipe Existing Pipe Existing Pipe Existing Pipe Existing Pipe Conduit/Interduct Conduit/Interduct Conduit/Interduct Conduit/Interduct Conduit/Interduct DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CROSS SECTIONS.dwgDATE/USER: 1/10/2017 11:29 AM / MmastersonRECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALECITY OF CARMEL RIVER ROAD PHASE 2______VERTICAL SCALE CROSS SECTIONS LINE "PR-A" 1"=5' 1"=5' XS24 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 M.A.M. 16-ENG-80 XS29 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE M.B. T.B. M.A.M. _____ 87+50 87+50 755 760 765 755 760 765 88+00 88+00 755 760 765 755 760 765 88+50 88+50 755 760 765 755 760 765 89+00 89+00 755 760 765 755 760 765 89+50 89+50 755 760 765 755 760 765 P.G.=760.874:1 3:1 4:1 P.G.=760.894:1 3:1 4:1 P.G.=760.734:1 4:14:1 P.G.=760.394:14:1 P.G.=759.964:1 Ex. El. 760.72Ex. El. 760.72Ex. El. 760.62Ex. El. 760.33Ex. El. 760.00Ex. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WEx. R/WFILL CUT AREA = 47.3 AREA = 6.3 VOL. = 89 VOL. = 15 FILL CUT AREA = 43.9 AREA = 7.0 VOL. = 84 VOL. = 12 FILL CUT AREA = 32.7 AREA = 8.3 VOL. = 72 VOL. = 13 FILL CUT AREA = 18.8 AREA = 8.9 VOL. = 49 VOL. = 15 FILL CUT AREA = 6.2 AREA = 5.9 VOL. = 23 VOL. = 14 Conduit/Interduct Conduit/Interduct Conduit/Interduct Conduit/Interduct Conduit/Interduct DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CROSS SECTIONS.dwgDATE/USER: 1/10/2017 11:29 AM / MmastersonRECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALECITY OF CARMEL RIVER ROAD PHASE 2______VERTICAL SCALE CROSS SECTIONS LINE "PR-A" 1"=5' 1"=5' XS25 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 M.A.M. 16-ENG-80 XS29 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE M.B. T.B. M.A.M. _____ 90+00 90+00 755 760 765 755 760 765 90+55 90+55 750 755 760 765 750 755 760 765 P.G.=759.52P.G.=759.04Ex. El. 759.62Ex. El. 759.04Ex. R/WEx. R/WEx. R/WEx. R/WFILL CUT AREA = 0.0 AREA = 9.9 VOL. = 6 VOL. = 15 FILL CUT AREA = 0.9 AREA = 0.4 VOL. = 1 VOL. = 10 Conduit/Interduct Conduit/Interduct DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CROSS SECTIONS.dwgDATE/USER: 1/10/2017 11:29 AM / MmastersonRECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALECITY OF CARMEL RIVER ROAD PHASE 2______VERTICAL SCALE CROSS SECTIONS LINE "W-EXIT" 1"=5' 1"=5' XS26 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 M.A.M. 16-ENG-80 XS29 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE M.B. T.B. M.A.M. _____ 10+86 10+86 745 750 755 760 745 750 755 760 748.51P.G.=752.084:1 11+50 11+50 745 750 755 745 750 755 748.70P.G.=752.084:1 12+00 12+00 745 750 755 745 750 755 748.85P.G.=752.084:1 12+50 12+50 745 750 755 745 750 755 749.29P.G.=752.284:1 13+33 13+33 750 755 760 750 755 760 751.00P.G.=753.764:1 Ex. El. 751.63Ex. El. 751.57Ex. El. 752.70Ex. El. 754.04Ex. El. 755.95FILL CUT AREA = 13.1 AREA = 28.8 VOL. = 0 VOL. = 0 FILL CUT AREA = 20.0 AREA = 44.1 VOL. = 41 VOL. = 81 FILL CUT AREA = 1.4 AREA = 81.9 VOL. = 21 VOL. = 112 FILL CUT AREA = 0.0 AREA = 150.7 VOL. = 1 VOL. = 216 FILL CUT AREA = 0.0 AREA = 178.3 VOL. = 0 VOL. = 506 SEE SHEET XS26 FOR LINE "W-ENT" Inv. In From Str. No. 80 = 749.08 Inv. Out = 749.08 Str. No. 81 12"Pr. R/WPr. R/WPr. R/WPr. R/WPr. R/W DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CROSS SECTIONS.dwgDATE/USER: 1/10/2017 11:29 AM / MmastersonRECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALECITY OF CARMEL RIVER ROAD PHASE 2______VERTICAL SCALE CROSS SECTIONS LINE "W-ENT" 1"=5' 1"=5' XS27 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 M.A.M. 16-ENG-80 XS29 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE M.B. T.B. M.A.M. _____ 10+88 10+88 745 750 755 745 750 755 11+50 11+50 745 750 755 745 750 755 12+00 12+00 745 750 755 745 750 755 12+58 12+58 745 750 755 760 745 750 755 760 12+95 12+95 750 755 760 750 755 760 P.G.=752.13748.52 4:1P.G.=752.13748.77 4:1P.G.=752.13748.97 4:1P.G.=752.564:1P.G.=753.454:1 Ex. El. 751.99Ex. El. 752.10Ex. El. 753.07Ex. El. 754.29Ex. El. 755.52FILL CUT AREA = 4.2 AREA = 37.6 VOL. = 0 VOL. = 0 FILL CUT AREA = 0.1 AREA = 76.4 VOL. = 5 VOL. = 131 FILL CUT AREA = 0.0 AREA = 128.3 VOL. = 0 VOL. = 189 FILL CUT AREA = 0.0 AREA = 141.3 VOL. = 0 VOL. = 283 750.16 751.00 SEE SHEET XS25 FOR LINE "W-EXIT" Inv. In From Str. No. 82A = 749.19 Inv. Out = 749.19 Str. No. 82 12" Conduit/Interduct Conduit/Interduct Conduit/Interduct Conduit/Interduct DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CROSS SECTIONS.dwgDATE/USER: 1/10/2017 11:29 AM / MmastersonRECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALECITY OF CARMEL RIVER ROAD PHASE 2______VERTICAL SCALE CROSS SECTIONS LINE "B" 1"=5' 1"=5' XS28 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 M.A.M. 16-ENG-80 XS29 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE M.B. T.B. M.A.M. _____ 1+24 1+24 745 750 755 760 765 745 750 755 760 765 P.G.=755.264:1 0+76 0+76 745 750 755 760 765 745 750 755 760 765 P.G.=755.500+00 0+00 750 755 760 765 750 755 760 765 P.G.=755.884:1 0+30 0+30 750 755 760 765 750 755 760 765 P.G.=755.734:1 Ex. El. 756.60Ex. El. 756.92Ex. El. 757.27Ex. El. 757.70Str. No. 32 747.43 Str. No. 32 747.22 Conduit/Interduct Conduit/Interduct DIRECTORY PATH: R:\Active\Platinum Properties\River Road Phase 2\CAD\PLANSFILENAME: CROSS SECTIONS.dwgDATE/USER: 1/10/2017 11:29 AM / MmastersonRECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALECITY OF CARMEL RIVER ROAD PHASE 2______VERTICAL SCALE CROSS SECTIONS LINE "B" 1"=5' 1"=5' XS29 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 50 10 15 20 25 30 35 40 45 50 55 60 65 70 7551015202530354045505560657075 M.A.M. 16-ENG-80 XS29 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE M.B. T.B. M.A.M. _____ 1+75 1+75 745 750 755 760 765 745 750 755 760 765 P.G.=755.002+25 2+25 745 750 755 760 765 745 750 755 760 765 P.G.=755.164:1 2+70 2+70 750 755 760 765 750 755 760 765 P.G.=755.413+15 3+15 750 755 760 765 750 755 760 765 P.G.=755.654:1 Ex. El. 757.36Ex. El. 757.20Ex. El. 757.21Ex. El. 757.53Str. No. 32B 747.05 Str. No. 32B 746.83 Conduit/Interduct Conduit/Interduct