HomeMy WebLinkAboutA121 First Floor Reflected CeilingDSNSNELNELN
REFLECTEDCEILING PLANA121NO WORK IN THIS AREA UNLESS OTHERWISE NOTED.PROVIDE NEW CEILING GRID AND TILE AS SHOWN TO MATCH ANDALIGN WITH EXISTING SUCH THAT NEW AND EXISTING CEILINGSAPPEAR CONTINUOUS.AT EXISTING PENDANT LIGHTS PROVIDE NEW CEILING TILE ASREQUIRED FOR A FINISH LOOK.PLAN NOTESLIGHT CIRCUITLIGHT SWITCH, DIMMERLIGHT SWITCH, 3-WAYLIGHT SWITCHNDNN3D3EXIT LIGHT FIXTURELIGHT FIXTURE,PENDANTRECESSED LIGHTFIXTURELIGHT FIXTURE, 2'x4', FLATPANEL LEDRELOCATED DIFFUSER,LAY-IN, 4"x4'RELOCATED DIFFUSER,LAY-IN, 2'x2'CEILING GRID,SUSPENDED, 2'x2'NEW OR RELOCATEDEXISTING TO REMAINPENDANT LIGHT FIXTURE,EXACT SPECIFICATION TBDLIGHT FIXTURE,TRACKLIGHT FIXTURE,PENDANTPENDANT LIGHT FIXTURE,VARIESLIGHT FIXTURE,TRACKEXIT LIGHT FIXTURELIGHT CIRCUITLIGHT SWITCH, DIMMERLIGHT SWITCH, 3-WAYLIGHT SWITCHCEILING GRID,SUSPENDED, 2'x2'DIFFUSER,LAY-IN, 4"x4'DIFFUSER,LAY-IN, 2'x2'GYPSUM BOARD CEILINGLIGHT FIXTURE, 2'x4', FLATPANEL LEDLEGENDREFLECTED CEILING PLANRECESSED LIGHTFIXTUREDESCRIPTIONDATEISSUE11.11.21REVIEW SET11.17.21PERMIT SETREVISIONSDESCRIPTIONMARKDATEDBTHIS DRAWING, AND THE IDEAS,DESIGNS AND CONCEPTS CONTAINEDHEREIN, ARE THE EXCLUSIVEINTELLECTUAL PROPERTY OF SCHOTTDESIGN, INC., AND ARE NOT TO BEUSED OR REPRODUCED IN WHOLE, ORIN PART, WITHOUT THE WRITTENCONSENT OF SCHOTT DESIGN.450 E. 96th Street
Indianapolis, IN 46240
p: 317.387.1700
www.schottdesign.comPROJECT NUMBERDRAWN BYPROJ. MGRM/O
STRATEGIES
PENN ON PARKWAY - SUITE 160
501 PENNSYLVANIA PKWY, INDIANAPOLIS, IN 46280CBBW2021.1041ST FLOORN02'4'8'16'EMERGENCY LIGHT FIXTUREEMERGENCY LIGHT FIXTURE MECHANICAL DIFFUSER RELOCATIONA1211*REFER TO MECHANICAL NOTES FOR FURTHER INFORMATIONEXISTING VAV BOXES ORHEAT PUMP AND MAIN SUPPLYDUCTS TO REMAINRELOCATE DIFFUSERS &FLEXDUCT IF REQUIREDVAV /HEAT PUMPGYPSUM BOARD CEILINGSWITCH, GARBAGEDISPOSAL (ABOVECOUNTERTOP)NGGSWITCH, GARBAGEDISPOSALEXPOSED TO DECKA1211SWITCH, EXHAUST FANNEESWITCH, EXHAUST FAN1.REUSE EXISTING CEILING GRID AND TILE UNLESS OTHERWISE NOTED.EXISTING GRID IS 2'x2' AT 9'-11" A.F.F. TILES ARE 2X2' ACOUSTICAL LAYIN TILES. REPAIR ANY DAMAGED GRID AND REPLACE ANYDAMAEGED TILES WITH NEW MATCH EXISTING.2.IF IN GOOD CONDITION, EXISITING CEILING TILES SALVAGED FROMDECONSTRUCTION CAN BE SUBSTITUTED FOR NEW. PROVIDE LIKECEILING TILES IN INDIVDUAL ROOMS WHERE POSSIBLE TO CREATEUNIFORM LOOK.3.PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PERNEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTSCONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IFTHE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ONPLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS,CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHINSUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDIOR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULTIN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.4.UNLESS NOTED OTHERWISE, THE LIGHTS SHOWN AS "NEW ORRELOCATED" ARE TO BE RELOCATED FROM A PREVIOUS LOCATIONAS SHOWN ON THE DEMOLITION PLAN. THE DESIGN INTENT IS LESSTHAN 50% OF THE LIGHTS ARE ACTUALLY BEING REPLACED WITH NEWAND OVERALL WATTAGE IS STAYING THE SAME OR DECREASING.LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS.ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANTINSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1,CONTRACTOR MUST NOTIFY SDI.5.ALL NEW SWITCHES TO BE OCCUPANCY SENSORS; PROVIDE COMBOUNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH AONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BELOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OFINCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTEDOCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED.6.NEW DEVICES AND FACE PLATES TO MATCH EXISTING. WHEREPOSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATEMULTI-SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ONPLAN.7.ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND ISOUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TOADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES ANDLIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTINGELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR ISTO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIREDSO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITHALL APPLICABLE CODES.8.EXISTING SWITCHING TO REMAIN THROUGHOUT UNLESS OTHERWISENOTED. ENSURE EACH SUITE LIGHTING TO REMAIN OPERATIONALINDEPENDENTLY. UTILIZE EXISTING SWITCHING AND RE-CIRCUIT ASREQUIRED PER NEW DEMISE.9.CONTRACTOR TO ENSURE ALL LIGHT COLOR TEMPERATURES ARE THESAME FOR CONSISTANT LOOK THROUGHOUT.GENERAL NOTES1. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND ISOUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICALAPPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALLMECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS ANDFLEX DUCT PER NEW WALL LAYOUT. IF IN GOOD CONDITION, EXISTINGH.V.A.C. DIFFUSERS SALVAGED FROM DECONSTRUCTION MAY BESUBSTITUTED FOR NEW. NO NEW HARD DUCTWORK OR EQUIPMENT ISBEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFYAPPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THATADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THEINDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES.MECHANICAL NOTESAREA NOT IN CONTRACTAREA OF WORKEXPOSED TO DECKLIGHT FIXTURE, 2'x4',INDIRECT LEDLIGHT FIXTURE, 2'x4',INDIRECT LEDLIGHT FIXTURE, 2'x2', FLATPANEL LEDLIGHT FIXTURE, 2'x2', FLATPANEL LED