HomeMy WebLinkAboutE111 ElectricalDWREFRIGBYTENANT
REFRIGBYT
ENANT
TVTVENTRY101STG.102BOARD ROOM103BREAK104OFFICE105OFFICE106OFFICE107ENTRY109STORAGE110BREAK111COLLABORATIONCORRIDOR112CONF.113OPENCOLLABORATION114OFFICE115OFFICE116OFFICE117OFFICE118STG./IT119OFFICE 120+42"
+42"
+42"
+42"+56"+42"+42"+42"+42"
+42"
+42"
+60"
+60"
+44"+44"
+60"
+60"
+
6
0
"
+
6
0
"
+44"
DED
+42"TV+60"
+60"
+24" D
E
D
GFCI
GFCI
+42"TV+72"
+72"
+72"ELECTRICAL PLANE111NOT USED.COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDEDEDICATED RECEPTACLE AS REQUIRED.PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSETINTO CABINET/ WALL FOR TENANT'S MICROWAVE, CENTERED AT24" A.F.F.PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTEDTELEVISION AT HEIGHT NOTED ON PLAN. COORDINATE EXACTLOCATION WITH TENANT.PROVIDE SEPARATE PRICE FOR NEW FLUSH MOUNT FLOOR COREWITH POKE THRU DEVICE FOR ELECTRICAL AND DATA.COORDINATE WITH TENANTS FURNITURE VENDOR ON EXACTLOCATION. PROVIDE POKE THRU DEVICE SUBMITTAL TO TENANTFOR APPROVAL PRIOR TO ORDERING.IF SEPARATE PRICE IS ACCEPTED (SEE SHEET A111 NOTE A10),PROVIDE (2) DUPLEX ABOVE COUNTER OUTLETS AT 50" AFF.PLAN NOTESELECTRICAL PLANLEGENDDESCRIPTIONDATEISSUE11.11.21REVIEW SET11.17.21PERMIT SETREVISIONSDESCRIPTIONMARKDATEDBTHIS DRAWING, AND THE IDEAS,DESIGNS AND CONCEPTS CONTAINEDHEREIN, ARE THE EXCLUSIVEINTELLECTUAL PROPERTY OF SCHOTTDESIGN, INC., AND ARE NOT TO BEUSED OR REPRODUCED IN WHOLE, ORIN PART, WITHOUT THE WRITTENCONSENT OF SCHOTT DESIGN.450 E. 96th Street
Indianapolis, IN 46240
p: 317.387.1700
www.schottdesign.comPROJECT NUMBERDRAWN BYPROJ. MGRM/O
STRATEGIES
PENN ON PARKWAY - SUITE 160
501 PENNSYLVANIA PKWY, INDIANAPOLIS, IN 46280CBBW2021.1041ST FLOORN02'4'8'16'1.TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OFFURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS.2.ALL OUTLETS ARE TO INSTALLED 18" MIN. A.F.F. TO THE CENTER OFTHE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALLNEW DEVICES AND FACE PLATES TO MATCH EXISTING.3.REFER TO DOOR SCHEDULE AND COORDINATE WITHTENANT/OWNER REGARDING POWER LOCATIONS TOACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/ORMAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THETENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI.4.CONTRACTOR TO PROVIDE GFCI OUTLET FOR WATER HEATER ANDAUTOMATIC SHUTOFF VALVES AS REQUIRED.5.ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND ISOUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITEDTO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICESAND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THEEXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICALCONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONALWORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED ANDMUST COMPLY WITH ALL APPLICABLE CODES.GENERAL NOTESDEDPOWER OUTLET, DUPLEXNEW CONSTRUCTIONEXISTING TO REMAINPOWER OUTLET,QUADRUPLEXJUNCTION BOXPOWER OUTLET, DUPLEXPOWER OUTLET,QUADRUPLEXJUNCTION BOXBOX, BLANK COVER PLATEBOX, OPENBOX, BLANK COVER PLATEBOX, OPENPROVIDE JUNCTION BOXABOVE CEILING FORPOWER POLECONNECTION. POWERPOLE BY OTHERS.POWER AND DATA POLEFLOOR BOX WITH POWERAND DATA, FLUSHMOUNTEDFLOOR BOX WITHJUNCTION BOX ANDDATA, FLUSH MOUNTEDFLOOR BOX WITH POWERAND DATA, FLUSHMOUNTEDFLOOR BOX WITHJUNCTION BOX ANDDATA, FLUSH MOUNTEDDEDICATED CIRCUITDATA/COMMUNICATIONOUTLET (PROVIDE BOXAND PULL STRING ONLY)DATA/COMMUNICATIONOUTLETGFCIGROUND FAULT CIRCUITINTERRUPT OUTLETHEIGHT OF ELECTRICALOR DATA DEVICECEILING MOUNTEDJUNCTION BOXCEILING MOUNTEDJUNCTION BOXJJBOJ+42"AREA NOT IN CONTRACTAREA OF WORK