T ENTRY101STG.102xBOARD ROOM10326'-0"13'-3"BREAK104OFFICE105122 SFxOFFICE10611'-0"13'-9"xOFFICE10718'-3"13'-9"xENTRY10923'-11"9'-1"xSTORAGE11011'-8"11'-5"BREAK111COLLABORATIONCORRIDOR112xCONF.11311'-7"12'-11"OPENCOLLABORATION114xOFFICE11513'-1"9'-5"xOFFICE11619'-6"20'-0"xOFFICE11715'-0"10'-0"xOFFICE11815'-0"12'-7"xSTG./IT1194'-1"3'-8"xOFFICE 12018'-10"13'-9"FEFEELNELNFELIFE SAFETYPLANL100LIFE SAFETY PLANDESCRIPTIONDATEISSUE11.11.21REVIEW SET11.17.21 PERMIT SETREVISIONSDESCRIPTIONMARKDATE DBTHIS DRAWING, AND THE IDEAS,DESIGNS AND CONCEPTS CONTAINEDHEREIN, ARE THE EXCLUSIVEINTELLECTUAL PROPERTY OF SCHOTTDESIGN, INC., AND ARE NOT TO BEUSED OR REPRODUCED IN WHOLE, ORIN PART, WITHOUT THE WRITTENCONSENT OF SCHOTT DESIGN.450 E. 96th Street
Indianapolis, IN 46240
p: 317.387.1700
www.schottdesign.comPROJECT NUMBERDRAWN BYPROJ. MGRM/O
STRATEGIES
PENN ON PARKWAY - SUITE 160
501 PENNSYLVANIA PKWY, INDIANAPOLIS, IN 46280CBBW2021.1041ST FLOORN1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PERNEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTSCONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IFTHE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ONPLAN ARE FOR REFERENCE ONLY.2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES),EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANYOTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TOMEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE,INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS,CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE,ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI ORTENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT INCONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW ANDEXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPEAND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANYPOINT TO A VISIBLE EXTINGUISHER.THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES.4. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILDSERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE,WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FORTHE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLERSYSTEM.5. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIREDDRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATEDDOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVINGJURISDICTION OVER THE PROJECT.LIFE SAFETY NOTESL1. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTIONDETAILS.L2. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARMNOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXITSIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS ASREQUIRED TO MEET ALL LOCAL AND STATE CODES.L3. SQUARE FOOTAGES NOTED IN CODE SUMMARY CHART ARE NOTREFLECTIVE OF USABLE/RENTABLE SQUARE FOOTAGE AS CALCULATEDBY METHODS SUCH AS BOMA STANDARDS. OCCUPANCYCALCULATIONS & TOTALS ARE CALCULATED BASED ONINTERNATIONAL BUILDING CODE NOT ACTUAL HEAD COUNTS.CONTACT SDI FOR ADDITIONAL INFORMATION AS NECESSARY.GENERAL NOTESEXISTING ELECTRICAL PANEL LOCATIONEXISTING EXITEPEXLEGENDFIRE EXTINGUISHEREXIT SIGN + EMERGENCY LIGHT COMBOFEEMERGENCY LIGHTAREA NOT IN CONTRACTAREA OF WORKTRAVEL DISTANCESCOPE OF WORKOFFICE REMODEL OF PREVIOUSLY BUILT-OUT OFFICE SPACETOTAL BUILDING AREATOTAL PROJECT AREACHANGE OF OCCUPANCY CLASS? NOOCCUPANCY CLASSIFICATIONB(USINESS)SPRINKLER SYSTEM (YES/NO)YES - EXISTING TO REMAINTOTAL AREA OF ACCESSORY USES0TOTAL AREA ON THE FLOORSFSF/FLOORXSTORIESSFSF33,830 SFACCESSORY AREA EXCEEDS 10%NOFIRE BARRIERS, AND/OR OCCUPANCYSEPARATIONS (IF REQUIRED)N/A=CODE SUMMARYPREVIOUS USE OF SPACEB(USINESS)ASHRAE 90.1 SUMMARYEXEMPT (SEE REFLECTED CEILING PLAN)BUILT BEFORE 1978?NO5,29233,8304135,319BUILDING CONSTRUCTION TYPEII-BTRAVEL DISTANCE = 144'-9"0 2' 4' 8'16'ENLARGED LIFE SAFETY PLANL1001L10010 4' 8' 16'EPEPEXEXEXEXEXTRAVEL
D
ISTANCE
=
101
'-9
"BUSINESSBUSINESSBUSINESSBUSINESSOCCUPANCY CALCULATIONS'AREA SUITE A'SPACE TYPEAREASF PER OCCUPANT OCCUP LOADGEN. OFFICESF100NUMBER OF EXITSREQUIRED: 1 PROVIDED: 1TOTAL OCCUPANTS IN AREA232,30323SPACE TYPEAREASF PER OCCUPANT OCCUP LOADGEN. OFFICESF100NUMBER OF EXITSREQUIRED: 1 PROVIDED: 2TOTAL OCCUPANTS IN AREA302,98930OCCUPANCY CALCULATIONS'AREA SUITE B'SUITE ASUITE B