HomeMy WebLinkAboutA111 First Floor ArchitecturalDW ENTRY101STG.102BOARD ROOM103BREAK104OFFICE105OFFICE106OFFICE107ENTRY109STORAGE110BREAK111COLLABORATIONCORRIDOR112CONF.113OPENCOLLABORATION114OFFICE115OFFICE116OFFICE117OFFICE118STG./IT119OFFICE 120FEFE4'
-0
"8'-9"10'
-2
"FE5'-4"5'-5"ARCHITECTURALFLOOR PLANA111ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESSSTUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLSARE IN LINE WITH EXISTING WALLS.NEW FIRE EXTINGUISHER TO BE PROVIDED AND INSTALLED BYCONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLEDACCORDING TO NFPA 10.EXISTING FIRE EXTINGUISHER TO REMAIN IF IN PROPER WORKINGORDER. CONTRACTOR TO CONFIRM THAT EXISTING FIREEXTINGUISHER IS INSTALLED ACCORDING TO NFPA 10.PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FORTENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACTLOCATION WITH TENANT.CONFIRM THAT EXISTING WALL MATCHES WALL TYPE "W2". IF NOT,ALTER EXISTING WALL AS REQUIRED TO MATCH "W2".WHERE DECONSTRUCTION HAS OCCURRED, PROVIDE NEWFINISHED ENDS AS REQUIRED.NO WORK IN THIS AREA UNLESS OTHERWISE NOTED.BASE BID: EXISTING ENTRY DOOR TO REMAIN. PROVIDE SEPARATEPRICE TO RELOCATE HERCULITE DOOR AND PROVIDE NEWLOCKING LADDER PULL. REFER TO SHEETS D111 AND A131 FORADDITIONAL INFORMATION.PROVIDE SEPARATE PRICE TO RELOCATE HERCULITE SYSTEM ANDDOOR. IF ALTERNATE IS ACCEPTED, RELOCATE EXISTING WALLMOUNTED TELEVISION WITHIN CONF 113. COORDINATE EXACTLOCATION WITH TENANT.PROVIDE SEPARATE PRICE FOR NEW 18” DEEP BY FULL LENGTHPLASTIC LAMINATE COUNTER AT 42” AFF. SUPPORT COUNTER ASREQUIRED WITH A&M PRE-FINISHED WHITE MOUNTING BRACKETSAS REQUIRED TO SUPPORT COUNTER._______________________________________________________________PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTEAND VENT PIPING FOR SINKS. PROVIDE INSULATION ON ALL NEWAND EXISTING PIPING. REFER TO LANDLORD FOR SOURCE OF HOTWATER AND LOCATION ALLOWED IN THIS BUILDING.CONTRACTOR TO INSTALL AUTOMATIC SHUTOFF VALVES ANDBACK FLOW PREVENTERS AS REQUIRED.PROVIDE WATER LINE WITH BACKFLOW PREVENTER FORREFRIGERATOR. CONFIRM LOCATION WITH TENANT.PLAN NOTESARCHITECTURAL PLANWALLDOOR AND FRAME(SEE DOOR SCHEDULE)NEW CONSTRUCTIONEXISTING TO REMAINWALLDOOR AND FRAMEWINDOW / SIDELIGHTWINDOW / SIDELIGHTARCHITECTURAL LEGENDPARTIAL HEIGHT WALLPARTIAL HEIGHT WALL DEMISING WALL TO DECKWITH INSULATION358" METAL STUDS AT 16" O.C.;ONE LAYER OF 58" TYPE "X" GYPSUM BOARDEACH SIDE;EXTEND WALL TO UNDERSIDE OF DECK;FIBERGLASS SOUND BATT INSULATION INSIDEWALL AND 2'-0" EACH SIDE OF WALL ABOVECEILINGW1W2 WALL WITH INSULATION358 " METAL STUDS AT 16" O.C.;ONE LAYER OF 58" TYPE "X" GYPSUM BOARDEACH SIDE;EXTEND WALL TO UNDERSIDE OF CEILING;FIBERGLASS SOUND BATT INSULATION INSIDEWALL AND 2'-0" EACH SIDE OF WALL ABOVECEILINGWALL TYPESW1NOTE:ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL.ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED.PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED INRESTROOM AND/OR SHOWER ROOMS.NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THISPROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS.DESCRIPTIONDATEISSUE11.11.21REVIEW SET11.17.21PERMIT SETREVISIONSDESCRIPTIONMARKDATEDBTHIS DRAWING, AND THE IDEAS,DESIGNS AND CONCEPTS CONTAINEDHEREIN, ARE THE EXCLUSIVEINTELLECTUAL PROPERTY OF SCHOTTDESIGN, INC., AND ARE NOT TO BEUSED OR REPRODUCED IN WHOLE, ORIN PART, WITHOUT THE WRITTENCONSENT OF SCHOTT DESIGN.450 E. 96th Street
Indianapolis, IN 46240
p: 317.387.1700
www.schottdesign.comPROJECT NUMBERDRAWN BYPROJ. MGRM/O
STRATEGIES
PENN ON PARKWAY - SUITE 160
501 PENNSYLVANIA PKWY, INDIANAPOLIS, IN 46280CBBW2021.1041ST FLOORN02'4'8'16'1.SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT.2.REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT ORWALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALLFINISH. REFER TO MANUFACTURER RECOMMENDATIONS.3.PROVIDE INSULATION ON ALL NEW AND EXISTING PLUMBINGPIPING AND BACK FLOW PREVENTERS ON ALL WATER LINES ASREQUIRED.GENERAL NOTESW?AREA NOT IN CONTRACTAREA OF WORKW2W2W2W2W2W2A2112