Loading...
HomeMy WebLinkAboutGALLAGHER PERMIT SET A202D E F G H I J ELEVATOR 6A ELEVATOR 6B STAIR 6A ELEVATOR 6C ELEVATOR LOBBY ELEC. STORAGE JAN. CORRIDOR MEN RESTROOM WOMEN RESTROOM STAIR 6B SHARED BALCONY 18"CLEAR12"CLEAR18"CLEARTENANTFUTURE 10'-0"209 CORRIDOR 9'-0" 214 OFFICE 6 9'-0" 206 OFFICE 5 9'-0" 205 ENTRY 10'-0"200 ROOMCONFERENCE 10'-0"209 HUDDLE ROOM 9'-0" 213 OFFICE 3 9'-0"203 OFFICE 4 9'-0"204 COLLABORATION SPACEPANTRY/ 10'-0"210 BRANCH MANAGER 9'-0" 216 OFFICE 1 9'-0" 217 OFFICE 2 9'-0" 219 CLOSET 9'-0" 220ROOMMEETING 9'-0"218 ROOMINTERVIEW 9'-0"201 CLOSET 9'-0" 202 OFFICE 2OPEN 10'-0" 211 OFFICE 1OPEN 10'-0" 215 CLOSET 9'-0" 207 ROOMCOPY 10'-0" 221 ROOMDATA 9'-0"208 BRANCH MANAGER 9'-0" 212 8'-11" 8'-11" 9'-11"9'-11" CORRIDOR 9'-0" 222 8'-11" 8'-11" 9'-11" 1'-4" FINISH CEILING, REFERENCE REFLECTED CEILING PLAN. PROVIDE BACKER ROD AND SEALANT AS REQUIRED. PROVIDE KICKERS AS REQUIRED FOR SECURE CONSTRUCTION OF BULKHEAD. 3-5/8" METAL STUD +10'-0" B.O. FINISH CEILING +11'-0" F.V. B.O. BULKHEAD +9'-11" B.O. BULKHEAD EXTEND GYPSUM WALLBOARD 6" ABOVE FINISH CEILING.1"UNDERSIDE OF BULKHEAD TO BE PAINTED CEILING BRIGHT WHITE. EXISTING CONSTRUCTION TO REMAIN. VERIFY EXISTING CONDITIONS. A202SECOND LEVEL REFLECTED CEILINGPLANSECOND LEVEL REFLECTED CEILING PLAN 01 A202 SECOND LEVEL REFLECTED CEILING PLAN Scale: 3/16" = 1'-0"NORTHCONSTRUCTIONNOT FORT. JOLLY2110202021-12-29CONTACT(YYYY-MM-DD)CONSULTANTTITLE: DRAWING NO. (YYYY-MM-DD)DATEREV.DESCRIPTIONPROJECT:DATETITLE:CERTIFIED BY:CONSULTANTJOB NUMBERSHEET OFTELEPHONE:LAUTH GROUP, INC.PROJECT:CONTACT:PROJECT NUMBER:STATE NUMBER:E-MAIL:FAX:GALLAGHERAGORA OFFICE BUILDING10 WEST CARMEL DRIVE, SUITE 240CARMEL, IN 46032THE RENAISSANCE GROUPKEN STROKE317.848.6500317.848.6511KSTROKE@LAUTH.NET8555 North River Road .Suite 220 . Indianapolis . Indiana . 46240[p] 317. 842.8500 [f] 317.842.88772021-12-221PROPOSED CHANGE #1KEY PLAN - SECOND LEVEL NORTH PROJECT LOCATION 01 A202 Typical Bulkhead Detail Scale: 1" = 1'-0" 05 A202 Typical Suspended Ceiling Detail Not to Scale 02 A202 Typical Bulkhead Detail Scale: 1" = 1'-0" B.O. BULKHEAD REFERENCE R.C.P. FINISH CEILING 3-5/8" METAL STUD @ 16" O.C. TO DECK ABOVE FINISH CEILING - REFERENCE REFLECTED CEILING PLAN REFERENCE R.C.P. CEILING CROSS TEE MAIN RUNNER PROVIDE SEISMIC BRACING OF CEILING TEE 12 GAUGE VERTICAL HANGER WIRE 5/8" GYPSUM WALLBOARD. EXTEND 6" ABOVE FINISH CEILING B.O. BULKHEAD REFERENCE R.C.P. FINISH CEILING REFERENCE R.C.P. REFERENCE R.C.P. 3-5/8" METAL STUD @ 16" O.C. TO DECK ABOVE FINISH CEILING - REFERENCE REFLECTED CEILING PLAN 3-5/8" METAL KICKERS AS REQUIRED FOR BRACING. 5/8" GYPSUM WALLBOARD. EXTEND 6" ABOVE FINISH CEILING NEW WALL CONSTRUCTION, REFERENCE FLOOR PLAN FOR ADDITIONAL INFORMATION. 2 4 GENERAL CEILING NOTES CEILING LEGEND CEILING PLAN NOTES * ALL LIGHT FIXTURES ARE TO BE LED UNLESS NOTED OTHERWISE. GYPSUM BOARD 2X4 SUSPENDED ACOUSTICAL PANEL CEILING(REFERENCE FINISH SCHEDULE FOR TYPE) 2X2 SUSPENDED ACOUSTICAL PANEL CEILING (REFERENCE FINISH SCHEDULE FOR TYPE) 2X2 HVAC RETURN AIR GRILLE(REFERENCE MECHANICAL SCHEDULE) STRIP LIGHT FIXTURE RECESSED LED CAN LIGHT FIXTURE LED PENDANT LIGHT FIXTURE EXIT LIGHT FIXTURE 2X4 LED LAY-IN LIGHT FIXTURE (REFERENCE ELECTRICAL SCHEDULE) 2X2 HVAC DIFFUSER(REFERENCE MECHANICAL SCHEDULE) A. ALL WALLS EXTEND TO DECK UNLESS NOTED AS FOLLOWS: WALLS TO 6" ABOVE CEILING HEIGHT WALLS TO JOISTS ABOVE WALLS TO DECK ABOVE B. LIGHT FIXTURE AND DIFFUSERS ON DRAWINGS SHOWN FOR LOCATION ONLY. COORDINATE WITH MECHANICAL AND ELECTRICAL DRAWINGS FOR EXACT SPECIFICATIONS ANDVERIFICATION OF QUANTITY. C. ALL CEILING ARE TO BE INSTALLED AT 9'-0" UNLESS NOTEDOTHERWISE. D. CENTER ACOUSTICAL CEILING PANELS IN EACH DIRECTIONWITH THE MAIN PORTION OF ANY ROOM OR SPACE, UNLESSNOTED OTHERWISE. 6" J D NEW GYPSUM DRYWALL BULKHEAD LOCATION. ALIGN EDGEOF BULKHEAD WITH ADJACENT WALLS. REFERENCE TYPICAL BULKHEAD DETAIL 01/A202 AND 02/A202 FOR ADDITIONALINFORMATION. PROVIDE DIMMABLE FIXTURES AND CONTROLS. PROVIDE LOOSE LAID SOUND BATT INSULATION ALONG PERIMETER OVER CEILING IN THIS AREA. DO NOT PLACEINSULATION OVER LIGHTS OR RETURN AIR DIFFUSERS. PROVIDE AND INSTALL SUSPENDED CEILING GRID SYSTEM AND ACOUSTICAL CEILING TILES, WHERE INDICATED.REFERENCE TYPICAL SUSPENDED CEILING DETAIL 03/A202 FOR ADDITIONAL INFORMATION. PAINT ALL EXPOSED CEILING ELEMENTS (STEEL JOISTS, STRUCTURAL DECK, DUCTWORK, PIPING, ETC) TO BE P1. 1 2 3 4 2X2 LED LAY-IN LIGHT FIXTURE(REFERENCE ELECTRICAL SCHEDULE) 48" X 6" LAY-IN LIGHT FIXTURE SUSPENDED LIGHT FIXTURE 5 2 4 2 42 4 2 4 2 4 2 3 4 2 4 4 D6 6" 6"6"6"6"6"66"DD 358"1'-738"358"1 03 A202 Typical Bulkhead Detail Scale: 3/4" = 1'-0" FINISH CEILING, REFERENCE REFLECTED CEILING PLAN. EXTEND GYPSUM WALLBOARD 6" ABOVE FINISH CEILING. 6" METAL STUD. FIELD VERIFY FINAL SIZE REQUIRED TO ALIGN BULKHEAD WITH ADJACENT WALL. PROVIDE 2x BLOCKING. ALIGN BOTTOM OF BULKHEAD WITH EXISTING CURTAIN WALL MULLION. PROVIDE BACKER ROD AND SEALANT, TYPICAL. EXISTING SPANDREL PANEL LOCATION. EXISTING CURTAIN WALL TO REMAIN. PROTECT DURING ALL PHASES OF CONSTRUCTION. PROVIDE 2" RIGID INSULATION AT SPANDREL PANEL LOCATIONS. 03 A202 03 A202 04 A20204 A202 03 A202 04 A202 Typical Bulkhead Detail Scale: 3/4" = 1'-0" FINISH CEILING, REFERENCE REFLECTED CEILING PLAN. EXTEND GYPSUM WALLBOARD 6" ABOVE FINISH CEILING. 6" METAL STUD. FIELD VERIFY FINAL SIZE REQUIRED TO ALIGN BULKHEAD WITH ADJACENT WALL. PROVIDE 2x BLOCKING. ALIGN BOTTOM OF BULKHEAD WITH EXISTING CURTAIN WALL MULLION. PROVIDE BACKER ROD AND SEALANT, TYPICAL. EXISTING SPANDREL PANEL LOCATION. EXISTING CURTAIN WALL TO REMAIN. PROTECT DURING ALL PHASES OF CONSTRUCTION. PROVIDE 2" RIGID INSULATION AT SPANDREL PANEL LOCATIONS. D 6"66"6"2 1 6"03 A202 03 A202 03 A20203 A20203 A202 04 A202 1 1D 6"6" 6"6 D D6"6"6" 6" 6" 6" 6"6"6"6"D 2 4 6"2 4 4 2 4 2 4 2 4 4 2 4 2 4 2 4 2 4 2 3 4 4 1 62 4 D 06 A202 Typical Bulkhead Detail Scale: 3/4" = 1'-0" 06 A202 01/24/22