HomeMy WebLinkAboutU0.01 Basement Utility PlanCONCRETE SLABGFI220V
S
DEDICATED GFI w/ GAS WATER HEATER OPT.
GAS VALVEGFI
ELECTRICAL PANEL (VERIFY LOCATION IN FIELD)
GFI
DEDICATED GFI FOR SUMP PUMP (VERIFY IN FIELD)OPT. DEDICATED GFI FOR EJECTOR PUMP (VERIFY IN FIELD)
3SS
TO SWITCH \PABOVECONCRETE SLABCONCRETE SLAB\A1;14'-4"
\A1;2'-0"
U0.01 BASEMENT UTILITY PLANMidwest Zone Office1900 Golf Road - Suite 300Schaumburg, Illinois 60173(c) Copyright 2015 PulteGroup, Inc.
PRODUCT MANAGER----VERSION RELEASEDATE:xx/xx/xxxxPROJECT TYPE
Single Family
SHEET
PLAN NAME
SPECIFICATION LEVEL
NPC CHILD NUMBER
----
Truman
1702.300Home for * Market Home *, 7231-023002837 Trailblazer Court, Carmel, IN 46032BASEMENT FOUNDATION PLANSCALE: 1/4" = 1'-0" (HALF SCALE ON 11x17 PAPER)
Install Smoke/Carbon
Monoxcide Detector in
this area, per code
01/25/22