HomeMy WebLinkAboutA4.01 Roof PlanHR2SROOF AREA "A"SQ FTG2112AT / NEAR RIDGEAT / NEAR EAVEVENT TYPESQ. FT.REQUIREDRANGESQ. FT.SUPPLIEDPERCENTOF TOTALSUPPLIEDPOT LARGE(SQ. IN. EACH)POT SMALL(SQ. IN. EACH)RIDGE VENT(SQ. IN. PER LF)EAVE VENT(SQ. IN. EACH)CONT. VENT(SQ. IN. PER LF)61.0040.0018.0028.0010.00HIGH - POTVENTS ONLY2.823.523.3947.9480AT EAVE4.223.523.6852.06053.00TOTAL (MIN)7.047.047.07100.003 HIGH -RIDGE VENT2.823.523.5048.740028.00AT EAVE4.223.523.6851.26053.00TOTAL (MIN)7.047.047.18100.00ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLEHR2SROOF AREA "B"SQ FTG276AT / NEAR RIDGEAT / NEAR EAVEVENT TYPESQ. FT.REQUIREDRANGESQ. FT.SUPPLIEDPERCENTOF TOTALSUPPLIEDPOT LARGE(SQ. IN. EACH)POT SMALL(SQ. IN. EACH)RIDGE VENT(SQ. IN. PER LF)EAVE VENT(SQ. IN. EACH)CONT. VENT(SQ. IN. PER LF)61.0040.0018.0028.0010.00HIGH - POTVENTS ONLY0.370.460.4243.2610AT EAVE0.550.460.5656.7408.00TOTAL (MIN)0.920.920.98100.003 HIGH -RIDGE VENT0.370.460.5047.37004.00AT EAVE0.550.460.5652.6308.00TOTAL (MIN)0.920.921.06100.00ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLEHR2SROOF AREA "C"SQ FTG144AT / NEAR RIDGEAT / NEAR EAVEVENT TYPESQ. FT.REQUIREDRANGESQ. FT.SUPPLIEDPERCENTOF TOTALSUPPLIEDPOT LARGE(SQ. IN. EACH)POT SMALL(SQ. IN. EACH)RIDGE VENT(SQ. IN. PER LF)EAVE VENT(SQ. IN. EACH)CONT. VENT(SQ. IN. PER LF)61.0040.0018.0028.0010.00HIGH - POTVENTS ONLY0.190.240.4246.5610AT EAVE0.290.240.4953.4407.00TOTAL (MIN)0.480.480.91100.003 HIGH -RIDGE VENT0.190.240.00####000.00AT EAVE0.290.240.00######00.00TOTAL (MIN)0.480.480.00######ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE8:128:129:129:126.5:126.5:128:129:129:123:129:129:129:129:12"A"2112ROOF AREA:SQ. FT.PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATIONMIN. 71 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "E""B"276ROOF AREA:SQ. FT.3:128:12MIN. 153 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "D"9:129:124:12MIN. 157 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF4:124:124:12MIN. 208 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF\A1;1'-0"\PTYP.\A1;28'-0"\A1;4'-0"\A1;2'-11"\A1;3'-5{\H0.75x;\S1#2;}"\A1;4'-0"\A1;2'-11"\A1;5'-2{\H0.75x;\S1#2;}"\A1;4'-0"A4.01 ROOF PLANMidwest Zone Office1900 Golf Road - Suite 300Schaumburg, Illinois 60173(c) Copyright 2015 PulteGroup, Inc.
PRODUCT MANAGER----VERSION RELEASEDATE:xx/xx/xxxxPROJECT TYPE
Single Family
SHEET
PLAN NAME
SPECIFICATION LEVEL
NPC CHILD NUMBER
----
Truman
1702.300Home for * Market Home *, 7231-023002837 Trailblazer Court, Carmel, IN 46032ROOF PLANSCALE: 1/4" = 1'-0" (HALF SCALE ON 11x17 PAPER)
01/25/22