HomeMy WebLinkAboutM004.0Truss Connector Total List
Manuf Product Qty
USP HUS26 29
USP RT7A*100
24" OC
SPACING
24" OC
SPACING
24" OC SPACING SAUSALITO
LOT 180A
Hatch Legend
9" STEP CLG.
2' STEP CLG.
A-C1
A-C2
A-A1 A-A5A-A7 A-D1
A-D3
A-B1 A-B2A-B3A-B10A-B11A-E1
A-E2
A-V1
A-V2
A-V3
A-V1
A-V2
A-V3
A-V4
A-V5
A-V1
A-V2
A-V3
A-V7
A-V8
A-V9
A-V10
A-V6 A-P1A-P12 PLY
2 PLY
2 PLY
2 PLY
(4) A-A2(3) A-A3 (2) A-A4 (5) A-A6 (9) A-D2(3) A-B4(2) A-B6(3) A-B8 (4) A-B9
(15) A-P2
1-04-0013-09-00 5-00-006-04-00 6-08-08 12-03-08 61-04-0086-08-006-02-00 8-11-00 71-07-0086-08-0012-00-00 18-04-08 8-08-08 10-08-00 6-02-00 4-10-00
61-00-00
20-07-00
9-09-08
9-09-08 20-07-00
61-00-00
37-03-081-03-00
28-10-08 IMPORTANT
THIS DRAWINGIS FOR FIELD PLACEMENT OF INDIVIDUAL
COMPONENTS ONLY, AND DOES NOT CONSTITUTE AN
ENGINEERED DOCUMENT.
NOTE
PROPER BEARINGANDBEARINGDESIGN INCLUDING
ANCHORAGE, IS THE RESPONSIBILITY OF THE BUILDING
DESIGNER, ARCHITECT AND /OR BUILDINGENGINEER. REFER
TO INDIVIDUAL TRUSS DESIGNS FOR REACTIONS, MINIMUM
REQUIRED BEARINGSIZE, UPLIFT, AND ADDITIONAL LOADS.
84 COMPONENTS DOES NOT ASSUME RESPONSIBILITYIN
THESE AREAS OF CONCERN.
BRACING
ERECTION, TEMPORARY, AND PERMANENT BRACINGIS THE
RESPONSIBILITY OF THE CONTRACTOR AND /OR BUILDING
DESIGNER. REFER TO INDIVIDUAL TRUSS DESIGNS FOR
ADDITIONAL BRACINGREQUIREMENTS. REFER TO BCSI-B1
SUMMARY SHEET. THE STRUCTURAL BUILDINGCOMPONENTS
ASSOCIATION COMMENTARY, AND RECOMMENDATIONS FOR
HANDLING, INSTALLING&BRACINGMETALPLATECONNECTED
WOOD TRUSSES. www.sbcindustry.com
INSTALLATION
DO NOT CUT, DRILL, OR ALTER TRUSSES. ANYQUESTIONS
CALL 84 COMPONENTS. PROPER INSTALLATION, AND
HANDLINGOF COMPONENTS IS THE RESPONSIBILITY OF THE
ERECTINGCONTRACTOR. 84 COMPONENTS MUSTBE
NOTIFIED OF ANY PROBLEMS, AND AFFORDED THE
OPPORTUNITY TO REVIEW, AND MAKENECESSARY
CORRECTIONS, ORNO BACKCHARGES WILL BE ACCEPTED
ORAPPROVED.
WARNING
WARNINGS, AND INSTRUCTIONS FOR ERECTION
OF COMPONENTS ARE INCLUDED IN THE DELIVERY PACKAGE.
KEEP THIS INFORMATION ON THE JOB SITE. THESE
DOCUMENTS WILL ALSO BE NEEDED FOR JOB SITE
INSPECTION. MISUSE AND IMPROPER INSTALLATION OF
COMPONENTS MAY RESULT IN FAILURE, BODILY INJURY, LOSS
OF PROPERTY, AND /OR LIFE.
RoofArea:
Overhang Length:
Eave Length:
HipLength:
ValleyLength:
Ridge Length:
SHEETNUMBER:
R1.1
RoofTruss
Placement Plan
SCALE: NTS
Job#: 23739
PO#:
Date: 3/12/2021
Drawn By: DS
Designed By: DS
Checked By:
ROOF LOADS:
TCLL: 20.0 lb/ft²
TCDL: 10.0 lb/ft²
BCLL: 0.0 lb/ft²
BCDL:10.0 lb/ft²
Building Code: IRC 2012
Wind Speed: 115 mph
On-Center Spacing: 24" U.N.O.
5820.73 SF
243.28 LF
379.04 LF
17.22 LF
243.59 LF
249.38 LF
ROOF DATA
THIS LAYOUTIS INTENDED FOR THE PURPOSE OF TRUSS LOCATION AND PLACEMENTONLY. REFER TO THE BUILDINGPLANS FOR ACTUAL BUILDINGCONSTRUCTION.TG180ALOTA6934 CHERRY CREEK BLVDCARMEL, INROOF TRUSS PLACEMENTPLAN237391850 N Graham RoadFranklin, Indiana 46131Office:(317) 346-4274Fax: (317) 346-0916