Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
GN010.5 Engr stamp
16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). October 6,2021 Liu, Xuegang Pages or sheets covered by this seal: I48223582 thru I48223619 My license renewal date for the state of Indiana is July 31, 2022. J21105943 Old Town - 59 Sunrise IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use,the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss AT01 Truss Type Attic Qty 1 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223582 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:20:51 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-6uaY6SfXtAqd9uz_ExGKw2LU4uc9aRNDYGJbfYyWQZQ Scale = 1:80.3 1 2 3 4 5 6 7 8 9 10 11 17 16 15 14 13 12 1823 24 4x6 5x6 4x6 2x4 10x10 2x4 10x10 3x6 2x4 3x6 2x4 2x4 2x4 2x4 4x6 4x6 3x4 3x4 2x4 2x4 2x4 2x4 15-4-0 8-1-141-0-04-7-104-7-10 9-4-44-8-10 17-2-07-9-12 24-11-127-9-12 29-8-64-8-10 34-4-04-7-10 4-7-10 4-7-10 9-4-4 4-8-10 11-8-3 2-3-15 12-6-13 0-10-11 17-2-0 4-7-3 21-9-3 4-7-3 22-7-13 0-10-11 24-11-12 2-3-15 29-8-6 4-8-10 34-4-0 4-7-10 1-5-912-10-141-5-98.00 12 Plate Offsets (X,Y)-- [14:0-4-12,0-5-0], [15:0-4-12,0-5-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.20 0.35 0.40 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.09 -0.13 0.01 -0.00 (loc) 14-15 14-15 12 17 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 233 lb FT = 20% GRIP 137/123 LUMBER- TOP CHORD 2x6 SPF No.2 BOT CHORD 2x6 SPF No.2 *Except* 14-15: onCENTER® AFL 2.1E 1 1/2" x 11 7/8" WEBS 2x3 SPF No.2 *Except* 8-14,4-15,1-17,11-12: 2x4 SPF-S Stud, 5-7: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 9-9-10 oc bracing. JOINTS 1 Brace at Jt(s): 18 REACTIONS.All bearings 34-4-0. (lb) - Max Horz 17=329(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 17, 12, 16, 13 except 15=-141(LC 10), 14=-143(LC 11) Max Grav All reactions 250 lb or less at joint(s) except 17=515(LC 19), 15=821(LC 18), 14=825(LC 19), 12=506(LC 1), 12=506(LC 1), 16=460(LC 1), 13=460(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-538/140, 2-4=-707/221, 4-5=-693/294, 5-6=-370/137, 6-7=-370/137, 7-8=-693/294, 8-10=-707/217, 10-11=-538/122, 1-17=-458/99, 11-12=-458/96 BOT CHORD 16-17=-304/339, 15-16=-155/485, 14-15=-76/550, 13-14=-40/397 WEBS 8-14=-333/214, 4-15=-337/217, 5-18=-275/230, 7-18=-275/230, 2-16=-483/131, 10-13=-483/131, 1-16=-64/353, 11-13=-48/338 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 5-5-6, Interior(1) 5-5-6 to 11-10-6, Exterior(2R) 11-10-6 to 22-5-10, Interior(1) 22-5-10 to 28-10-10, Exterior(2E) 28-10-10 to 34-2-4 zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 17, 12, 16, 13 except (jt=lb) 15=141, 14=143. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Attic room checked for L/360 deflection. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss AT02 Truss Type Attic Qty 5 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223583 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:20:53 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-2HhIX8hoPn4LOB7NMMJo?TQfhiE52GJW?aoijRyWQZO Scale = 1:74.5 1 2 3 4 5 6 7 8 9 10 11 17 16 15 14 13 12 1823 24 4x6 5x8 4x6 4x6 10x10 10x10 10x10 3x6 10x10 3x6 4x6 3x6 3x6 2x4 4x6 4x6 4x8 4x8 2x4 2x4 15-4-0 8-1-141-0-04-7-104-7-10 9-4-44-8-10 17-2-07-9-12 24-11-127-9-12 29-8-64-8-10 34-4-04-7-10 4-7-10 4-7-10 9-4-4 4-8-10 11-8-3 2-3-15 12-6-13 0-10-11 17-2-0 4-7-3 21-9-3 4-7-3 22-7-13 0-10-11 24-11-12 2-3-15 29-8-6 4-8-10 34-4-0 4-7-10 1-5-912-10-141-5-98.00 12 Plate Offsets (X,Y)-- [1:0-3-0,0-1-8], [11:0-3-0,0-1-8], [12:Edge,0-3-8], [13:0-2-8,0-2-0], [14:0-4-12,0-5-0], [15:0-4-12,0-5-0], [16:0-2-8,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.90 0.52 0.76 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.40 -0.71 0.04 0.22 (loc) 14-15 14-15 12 15-16 l/defl >999 >578 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 259 lb FT = 20% GRIP 137/123 LUMBER- TOP CHORD 2x6 SP 2400F 2.0E *Except* 1-3,9-11: 2x6 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E *Except* 14-15: onCENTER® AFL 2.1E 1 1/2" x 11 7/8" WEBS 2x3 SPF No.2 *Except* 8-14,4-15,1-17,11-12: 2x4 SPF-S Stud, 5-7: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-3-9 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 9-9-10 oc bracing. WEBS 1 Row at midpt 5-18, 7-18 JOINTS 1 Brace at Jt(s): 18 REACTIONS. (size)17=0-3-8, 12=0-3-8 Max Horz 17=329(LC 9) Max Grav 17=2012(LC 18), 12=2012(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2577/0, 2-4=-2717/0, 4-5=-1972/109, 7-8=-1975/109, 8-10=-2722/0, 10-11=-2577/0, 1-17=-1943/4, 11-12=-1942/3 BOT CHORD 16-17=-274/375, 15-16=-79/2333, 14-15=0/2121, 13-14=0/2086 WEBS 8-14=0/1206, 10-14=-360/301, 4-15=0/1206, 2-15=-360/298, 5-18=-2219/10, 7-18=-2219/10, 2-16=-678/97, 10-13=-685/101, 1-16=0/2016, 11-13=0/2011 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 5-5-6, Interior(1) 5-5-6 to 11-10-6, Exterior(2R) 11-10-6 to 22-5-10, Interior(1) 22-5-10 to 28-10-10, Exterior(2E) 28-10-10 to 34-2-4 zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Ceiling dead load (5.0 psf) on member(s). 4-5, 7-8, 5-18, 7-18; Wall dead load (5.0psf) on member(s).8-14, 4-15 6) Bottom chord live load (40.0 psf) and additional bottom chord dead load (10.0 psf) applied only to room. 14-15 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Attic room checked for L/360 deflection. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss AT03 Truss Type Attic Qty 2 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223584 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:20:54 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-WTFgkUhQA5CC0LiZv4q1XhzpB5TnngQfEEXFGtyWQZN Scale = 1:84.0 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 2125 26 4x6 5x8 12x18 MT18HS 10x10 2x4 2x4 12x12 8x8 2x4 3x6 10x10 10x10 10x16 MT18HS 3x6 3x6 2x4 4x8 8x8 5x10 MT18HS 5x12 2x4 2x4 15-4-0 8-1-144-7-10 4-7-10 9-4-4 4-8-10 17-2-0 7-9-12 24-11-12 7-9-12 27-0-8 2-0-12 28-6-8 1-6-0 34-4-0 5-9-8 4-7-104-7-10 9-4-44-8-10 11-8-32-3-15 12-6-13 0-10-11 17-2-04-7-3 21-9-34-7-3 22-7-130-10-11 24-11-12 2-3-15 27-0-82-0-12 28-6-81-6-0 34-4-05-9-8 1-5-912-10-141-5-92-5-82-0-02-0-08.00 12 Plate Offsets (X,Y)-- [10:0-4-0,0-4-8], [18:0-4-12,0-5-0], [19:0-2-8,0-2-0], [20:Edge,0-10-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.98 1.00 0.90 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.40 -0.73 0.18 0.22 (loc) 17-18 17-18 12 18-19 l/defl >999 >561 n/a >999 L/d 360 240 n/a 240 PLATES MT20 MT18HS Weight: 267 lb FT = 20% GRIP 137/123 137/123 LUMBER- TOP CHORD 2x6 SP 2400F 2.0E *Except* 1-3,10-11: 2x6 SPF No.2 BOT CHORD 2x6 SPF No.2 *Except* 9-16,10-13: 2x3 SPF No.2 17-18: onCENTER® AFL 2.1E 1 1/2" x 11 7/8" 16-17: 2x6 SP 2400F 2.0E WEBS 2x3 SPF No.2 *Except* 4-18,8-17,1-20,11-12: 2x4 SPF-S Stud, 8-15,5-7,11-14: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-1-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 9-9-10 oc bracing: 17-18 6-0-0 oc bracing: 15-16. WEBS 1 Row at midpt 8-17, 5-21, 7-21 JOINTS 1 Brace at Jt(s): 21 REACTIONS. (size)20=0-3-8, 12=0-3-8 Max Horz 20=329(LC 7) Max Grav 20=2012(LC 18), 12=2012(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2574/0, 2-4=-2697/0, 4-5=-1978/107, 7-8=-1983/110, 8-9=-4332/0, 9-10=-3854/0, 10-11=-4365/0, 1-20=-1944/0, 11-12=-2003/0 BOT CHORD 19-20=-273/371, 18-19=-74/2329, 17-18=0/2146, 15-16=-569/325, 9-15=-990/0, 14-15=0/3531, 10-14=0/675 WEBS 2-18=-318/274, 4-18=0/1164, 8-17=-1074/352, 15-17=0/2822, 8-15=-50/3469, 10-15=-763/176, 5-21=-2219/12, 7-21=-2219/12, 2-19=-629/69, 1-19=0/2019, 11-14=0/3363 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 5-5-6, Interior(1) 5-5-6 to 11-10-6, Exterior(2R) 11-10-6 to 22-5-10, Interior(1) 22-5-10 to 28-7-12, Exterior(2E) 28-7-12 to 34-2-4 zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Ceiling dead load (5.0 psf) on member(s). 4-5, 7-8, 5-21, 7-21; Wall dead load (5.0psf) on member(s).4-18, 8-17 7) Bottom chord live load (40.0 psf) and additional bottom chord dead load (10.0 psf) applied only to room. 17-18 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Attic room checked for L/360 deflection. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss GE01 Truss Type GABLE Qty 1 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223585 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:20:56 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-TsNR99jgiiSwFfsx1VsVd62KYvMYFlUyhY0MKmyWQZL Scale = 1:57.1 Sheet Front Full Sheathing1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 1415 29 28 27 26 25 24 23 22 21 20 19 18 17 16 30 31 3x6 3x6 4x6 3x6 3x6 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 22-0-0 22-0-0 -0-10-8 0-10-8 11-0-0 11-0-0 22-0-0 11-0-0 22-10-8 0-10-8 1-5-98-9-91-5-98.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-4], [14:0-3-0,0-1-4], [16:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.28 0.15 0.22 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.00 -0.00 -0.00 -0.00 (loc) 15 15 16 14 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 326 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 8-22 REACTIONS.All bearings 22-0-0. (lb) - Max Horz 29=-248(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 23, 25, 26, 27, 21, 20, 19, 18 except 29=-223(LC 6), 16=-198(LC 7), 28=-202(LC 7), 17=-184(LC 6) Max Grav All reactions 250 lb or less at joint(s) 16, 22, 23, 25, 26, 27, 21, 20, 19, 18 except 29=252(LC 9), 28=276(LC 8), 17=257(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 5-6=-112/251, 6-7=-149/319, 7-8=-180/374, 8-9=-180/374, 9-10=-149/319, 10-11=-112/251 WEBS 8-22=-335/100 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-10-8 to 4-5-2, Exterior(2N) 4-5-2 to 5-8-6, Corner(3R) 5-8-6 to 16-3-10, Exterior(2N) 16-3-10 to 17-6-14, Corner(3E) 17-6-14 to 22-10-8 zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 23, 25, 26, 27, 21, 20, 19, 18 except (jt=lb) 29=223, 16=198, 28=202, 17=184. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss GE02 Truss Type GABLE Qty 1 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223586 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:20:58 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-PEVBarlxDKieUz0K8vuziX8dsjswjXRF9sVTPeyWQZJ Scale = 1:93.9 Sheet BackLeft Option 12-4-0 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 22 21 20 1918 17 16 15 14 13 12 50 51 52 53 4x6 4x8 3x4 3x6 3x4 3x6 3x6 3x4 3x8 2x4 2x4 4x8 3x6 3x4 6x6 3x4 5x8 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 6-0-0 6-0-0 12-4-0 6-4-0 12-5-12 0-1-12 12-7-8 0-1-12 21-10-4 9-2-12 28-4-0 6-5-12 34-4-0 6-0-0 -0-10-80-10-8 6-0-06-0-0 11-6-35-6-3 17-2-05-7-13 22-9-135-7-13 24-5-31-7-5 28-4-03-10-13 34-4-06-0-0 35-2-80-10-8 1-5-912-10-141-5-98.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-12], [4:0-3-0,0-2-4], [6:0-1-4,0-1-8], [10:0-3-8,Edge], [32:0-2-0,0-0-8], [34:0-2-0,0-0-8], [36:0-2-0,0-0-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.49 0.86 0.77 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.28 -0.42 0.01 0.03 (loc) 15-16 15-16 12 13-15 l/defl >941 >622 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 540 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 6-16,6-15: 2x4 SPF No.2, 2-22,10-12: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 *Except* 6-23: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-12 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 3-16, 5-16, 6-16, 6-15, 7-15, 9-15 REACTIONS.All bearings 12-7-8 except (jt=length) 12=0-3-8. (lb) - Max Horz 22=-354(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 22, 21, 20 except 16=-183(LC 10), 12=-130(LC 11), 17=-379(LC 16) Max Grav All reactions 250 lb or less at joint(s) 19 except 22=312(LC 23), 21=470(LC 17), 16=1771(LC 17), 16=1409(LC 1), 12=1011(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 5-6=-64/260, 6-7=-765/314, 7-9=-752/164, 9-10=-1063/143, 2-22=-259/82, 10-12=-911/160 BOT CHORD 21-22=-338/408, 20-21=-229/253, 19-20=-229/253, 17-19=-229/253, 16-17=-229/253, 15-16=-63/297, 13-15=-21/767 WEBS 5-16=-364/252, 6-16=-933/111, 6-15=-277/997, 7-15=-362/252, 9-15=-377/175, 10-13=0/649 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-10-8 to 4-5-2, Interior(1) 4-5-2 to 11-10-6, Exterior(2R) 11-10-6 to 22-5-10, Interior(1) 22-5-10 to 29-10-14, Exterior(2E) 29-10-14 to 35-2-8 zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 22, 21, 20 except (jt=lb) 16=183, 12=130, 17=379. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss GE03 Truss Type GABLE Qty 1 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223587 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:20:59 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-tR3ZnBlZ_dqV67aWidPCEkgpR6MTS7yOOWF0x5yWQZI Scale = 1:56.0 1 2 3 4 5 6 7 8 9 10 11 23 22 21 20 19 18 17 16 15 14 13 12 24 25 4x6 3x6 4x6 3x6 3x6 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 18-8-0 18-8-0 9-9-0 9-9-0 18-8-0 8-11-0 2-3-88-9-82-10-28.00 12 Plate Offsets (X,Y)-- [12:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.43 0.20 0.17 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 12 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 89 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-17 REACTIONS.All bearings 18-8-0. (lb) - Max Horz 23=163(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 18, 20, 21, 16, 15, 14 except 23=-189(LC 6), 12=-243(LC 7), 22=-211(LC 10), 13=-220(LC 6) Max Grav All reactions 250 lb or less at joint(s) 23, 12, 17, 18, 20, 21, 16, 15, 14 except 22=305(LC 17), 13=308(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 4-5=-118/253, 5-6=-151/313, 6-7=-151/313, 7-8=-118/252 WEBS 6-17=-264/69 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) 0-1-4 to 5-4-14, Corner(3R) 5-4-14 to 13-3-2, Corner(3E) 13-3-2 to 18-6-12 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 18, 20, 21, 16, 15, 14 except (jt=lb) 23=189, 12=243, 22=211, 13=220. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss GE04 Truss Type GABLE Qty 1 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223588 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:21:00 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-Ldcx?XmBlxyMkG9jGKxRnyDuCWcWBVIXcA_ZTXyWQZH Scale = 1:54.2 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 8 7 6 5 28 29 6x6 4x6 2x4 2x4 3x6 3x8 3x4 3x8 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 7-5-8 7-5-8 16-1-8 8-8-0 7-5-8 7-5-8 12-7-0 5-1-8 16-1-8 3-6-8 3-9-138-9-83-0-28.00 12 Plate Offsets (X,Y)-- [9:0-1-6,0-1-0], [12:0-1-6,0-1-0], [15:0-1-6,0-1-0], [20:0-1-9,0-0-0], [23:0-1-9,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.82 0.59 0.49 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.13 -0.26 0.01 0.01 (loc) 5-6 5-6 5 6 l/defl >999 >745 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 294 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-8,4-5: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-9-13 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)8=0-3-8, 5=Mechanical Max Horz 8=-143(LC 6) Max Uplift 8=-68(LC 11), 5=-58(LC 11) Max Grav 8=633(LC 1), 5=633(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-514/130, 2-3=-476/148, 1-8=-573/131 BOT CHORD 5-6=-54/334 WEBS 1-6=-22/342, 3-5=-561/114 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 5-5-6, Exterior(2R) 5-5-6 to 10-8-2, Exterior(2E) 10-8-2 to 15-11-12 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 5. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss GE05 Truss Type GABLE Qty 1 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223589 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:21:01 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-ppAKCtnpWF4DMQkvq2SgK9mDyw4?w?Rhrqk7?zyWQZG Scale = 1:67.0 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 21 22 3x6 4x6 4x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 6x6 2x4 14-11-0 14-11-0 -0-10-8 0-10-8 14-11-0 14-11-0 1-5-911-4-148.00 12 Plate Offsets (X,Y)-- [2:0-2-0,0-1-8], [6:0-3-0,0-2-4], [19:0-2-8,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.18 0.07 0.30 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 -0.00 -0.00 (loc) 1 1 12 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 84 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 11-12: 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 19-20. WEBS 1 Row at midpt 11-12, 10-13, 9-14 REACTIONS.All bearings 14-11-0. (lb) - Max Horz 20=396(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 12, 13, 14, 15, 16, 17, 18 except 20=-278(LC 8), 19=-619(LC 10) Max Grav All reactions 250 lb or less at joint(s) 12, 13, 14, 15, 16, 17, 18 except 20=804(LC 10), 19=317(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-20=-1071/479, 2-3=-599/279, 3-4=-566/255, 4-5=-466/213, 5-7=-386/177, 7-8=-310/139 BOT CHORD 19-20=-570/227 WEBS 2-19=-406/1023 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-10-8 to 4-5-2, Exterior(2N) 4-5-2 to 9-5-10, Corner(3E) 9-5-10 to 14-9-4 zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 13, 14, 15, 16, 17, 18 except (jt=lb) 20=278, 19=619. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss GE06 Truss Type GABLE Qty 1 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223590 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:21:02 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-H?kiQDoRHYC3zaJ5NlzvsNIK_KLufPDq4UTgYQyWQZF Scale = 1:78.1 Sheet FrontLeft Option 2-11-8 1 Ply 7/16OSB8 1 2 3 4 5 6 12 10 9 8 7 26 27 11 28 4x6 2x4 3x4 2x4 3x6 3x6 3x4 3x4 3x6 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2-11-8 2-11-8 3-3-0 0-3-8 5-9-11 2-6-11 11-4-13 5-7-3 17-2-8 5-9-11 -0-10-80-10-8 5-9-115-9-11 11-4-135-7-3 17-2-85-9-11 1-5-912-11-48.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-8], [4:0-3-0,0-2-4], [19:0-1-10,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.42 0.41 0.46 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.05 -0.08 -0.01 0.02 (loc) 7-8 7-8 7 8-9 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 228 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 6-7,5-7: 2x4 SPF No.2, 2-12: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 8-3-6 oc bracing. WEBS 1 Row at midpt 6-7, 5-7 REACTIONS. (size)7=Mechanical, 12=3-3-0, 11=0-3-8 Max Horz 12=457(LC 10) Max Uplift 7=-322(LC 10) Max Grav 7=873(LC 17), 12=728(LC 17), 11=127(LC 16) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-748/0, 3-5=-496/0, 2-12=-691/14 BOT CHORD 11-12=-508/336, 9-11=-508/336, 8-9=-317/661, 7-8=-158/412 WEBS 3-8=-334/213, 5-8=-64/493, 5-7=-749/288, 2-9=0/498 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-10-8 to 4-5-2, Interior(1) 4-5-2 to 11-9-2, Exterior(2E) 11-9-2 to 17-0-12 zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable studs spaced at 2-0-0 oc. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 7=322. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss GE07 Truss Type GABLE Qty 1 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223591 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:21:03 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-mCI4dZo32sLwbkuIxTU8ParZ0kmTOwR_I8DE4syWQZE Scale = 1:60.0 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 19 18 17 16 15 14 13 12 20 2x4 5x6 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x4 2x4 14-3-0 14-3-0 -0-10-8 0-10-8 14-3-0 14-3-0 1-5-910-11-98.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.14 0.07 0.21 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 -0.00 (loc) 1 1 12 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 257 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 11-12: 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 7-11-9 oc bracing: 18-19. WEBS 1 Row at midpt 11-12, 10-13 REACTIONS.All bearings 14-3-0. (lb) - Max Horz 19=378(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 19, 12, 13, 14, 15, 16, 17 except 18=-277(LC 10) Max Grav All reactions 250 lb or less at joint(s) 12, 13, 14, 15, 16, 17, 18 except 19=402(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-19=-510/226, 2-3=-292/125, 3-4=-557/256, 4-5=-486/219, 5-6=-393/180, 6-8=-317/142 BOT CHORD 18-19=-551/226 WEBS 3-18=-267/650 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-10-8 to 4-3-0, Exterior(2N) 4-3-0 to 8-9-10, Corner(3E) 8-9-10 to 14-1-4 zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 19, 12, 13, 14, 15, 16, 17 except (jt=lb) 18=277. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss GE08 Truss Type GABLE Qty 1 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223592 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:21:04 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-EOsSquphpATnDuTUVA?NxoOfI74N7Jn7XoyncIyWQZD Scale = 1:49.9 Sheet Back Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 20 19 18 17 16 15 14 13 12 11 21 4x6 3x6 4x6 3x4 2x4 2x4 2x4 2x4 2x4 2x4 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 16-4-8 16-4-8 8-11-4 8-11-4 16-4-8 7-5-4 1-10-27-9-102-10-28.00 12 Plate Offsets (X,Y)-- [18:0-3-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.49 0.22 0.39 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 11 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 240 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 16-4-8. (lb) - Max Horz 20=223(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 11, 15, 16, 17, 18, 14, 13 except 20=-360(LC 8), 19=-335(LC 7), 12=-103(LC 6) Max Grav All reactions 250 lb or less at joint(s) 11, 15, 16, 17, 18, 14, 13, 12 except 20=398(LC 7), 19=401(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 4-5=-140/270, 5-6=-173/336, 6-7=-173/336, 7-8=-140/264 WEBS 6-15=-286/93 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) 0-1-4 to 5-4-14, Corner(3R) 5-4-14 to 10-11-4, Corner(3E) 10-11-4 to 16-3-4 zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 15, 16, 17, 18, 14, 13 except (jt=lb) 20=360, 19=335, 12=103. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss GE09 Truss Type GABLE Qty 1 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223593 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:21:06 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-An_DFaryLnjVSBdscb2r1DT2Qxm5bAHQ?6RuhByWQZB Scale = 1:47.5 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 21 22 3x4 3x6 4x6 3x6 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 14-5-0 14-5-0 -0-10-8 0-10-8 7-2-8 7-2-8 14-5-0 7-2-8 15-3-8 0-10-8 1-6-107-6-111-6-1010.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-4], [10:0-3-0,0-1-4], [12:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.26 0.14 0.58 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.00 -0.00 -0.00 0.00 (loc) 11 11 12 10 l/defl n/r n/r n/a n/r L/d 180 120 n/a 120 PLATES MT20 Weight: 66 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 14-5-0. (lb) - Max Horz 20=-221(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 17, 18, 15, 14 except 20=-182(LC 6), 12=-171(LC 7), 19=-166(LC 7), 13=-158(LC 6) Max Grav All reactions 250 lb or less at joint(s) 20, 12, 17, 18, 19, 15, 14, 13 except 16=252(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 4-5=-122/340, 5-6=-171/435, 6-7=-171/435, 7-8=-122/340 WEBS 6-16=-460/113 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-10-8 to 4-5-2, Corner(3R) 4-5-2 to 9-11-14, Corner(3E) 9-11-14 to 15-3-8 zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 17, 18, 15, 14 except (jt=lb) 20=182, 12=171, 19=166, 13=158. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss GE10 Truss Type GABLE Qty 1 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223594 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:21:07 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-ezYbTwsa65rM4LC3AIZ4ZQ0E6L8SKkxZDmBRDdyWQZA Scale = 1:56.9 Sheet Back Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 17 3x6 2x4 2x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 15-6-11 15-6-11 15-6-11 15-6-11 0-0-410-4-88.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.13 0.06 0.17 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 10 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 231 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud *Except* 1-5: 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 9-10, 8-11 REACTIONS.All bearings 15-6-11. (lb) - Max Horz 1=399(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 10, 1, 11, 12, 13, 14, 15 except 16=-106(LC 10) Max Grav All reactions 250 lb or less at joint(s) 10, 1, 11, 12, 13, 14, 15 except 16=269(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-588/269, 2-3=-454/203, 3-4=-383/176, 4-6=-306/137 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) 0-5-12 to 5-6-11, Exterior(2N) 5-6-11 to 10-1-14, Corner(3E) 10-1-14 to 15-5-7 zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 1, 11, 12, 13, 14, 15 except (jt=lb) 16=106. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss GE11 Truss Type GABLE Qty 1 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223595 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:21:08 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-695zgGsCtOzDhVmFk04J6eYPslUh3BBjSQw_l3yWQZ9 Scale = 1:56.9 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 17 3x6 2x4 2x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 15-6-11 15-6-11 15-6-11 15-6-11 0-0-410-4-88.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.13 0.06 0.17 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 10 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 231 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud *Except* 1-5: 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 9-10, 8-11 REACTIONS.All bearings 15-6-11. (lb) - Max Horz 1=399(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 10, 1, 11, 12, 13, 14, 15 except 16=-106(LC 10) Max Grav All reactions 250 lb or less at joint(s) 10, 1, 11, 12, 13, 14, 15 except 16=269(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-588/269, 2-3=-454/203, 3-4=-383/176, 4-6=-306/137 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) 0-5-12 to 5-6-11, Exterior(2N) 5-6-11 to 10-1-14, Corner(3E) 10-1-14 to 15-5-7 zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 1, 11, 12, 13, 14, 15 except (jt=lb) 16=106. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss M01 Truss Type Monopitch Qty 1 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223596 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:21:08 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-695zgGsCtOzDhVmFk04J6eYFalMN368jSQw_l3yWQZ9 Scale: 3/16"=1' 1 2 3 4 5 8 7 6 910 11 12 13 3x6 4x8 3x8 3x4 3x4 3x4 6x6 3x6 6-9-12 6-9-12 15-2-8 8-4-12 -0-10-8 0-10-8 6-9-12 6-9-12 15-2-8 8-4-12 1-5-911-7-49-1-1211-7-48.00 12 Plate Offsets (X,Y)-- [5:0-4-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.79 0.53 0.50 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.13 -0.24 -0.19 0.13 (loc) 6-7 6-7 10 7-8 l/defl >738 >419 n/a >623 L/d 360 240 n/a 240 PLATES MT20 Weight: 72 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-6: 2x4 SPF No.2, 2-8: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (size)8=0-3-8, 7=0-3-8, 10=0-3-0 Max Horz 8=396(LC 10) Max Uplift 8=-20(LC 6), 7=-280(LC 10), 10=-148(LC 10) Max Grav 8=272(LC 19), 7=963(LC 17), 10=299(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-324/251 BOT CHORD 7-8=-508/299 WEBS 3-7=-633/318, 2-7=-292/448, 5-10=-307/153 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-10-8 to 4-5-2, Interior(1) 4-5-2 to 14-9-4 zone; end vertical left exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 4) Bearing at joint(s) 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8 except (jt=lb) 7=280, 10=148. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss M02 Truss Type Monopitch Qty 8 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223597 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:21:09 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-aMfLuctqei54JfLRIjbYer5b88qCogFsh4gYHWyWQZ8 Scale = 1:17.0 1 2 3 5 4 2x4 2x4 3x6 3x4 1-11-8 1-11-8 -0-10-8 0-10-8 1-11-8 1-11-8 1-5-92-9-42-5-120-3-82-9-48.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.10 0.05 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.00 -0.00 -0.00 0.00 (loc) 5 5 4 4-5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 11 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 2-4: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 4=0-1-8 Max Horz 5=63(LC 7) Max Uplift 4=-60(LC 10) Max Grav 5=147(LC 1), 4=63(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; end vertical left exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss M03 Truss Type Monopitch Qty 1 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223598 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:21:10 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-2YDj5yuSP0DxxpwerR6nB3eeVY4KX1Q0vkP5qyyWQZ7 Scale = 1:60.5 1 2 3 4 5 8 7 6 910 11 3x6 4x8 3x6 3x4 3x4 3x4 6x8 3x6 6-9-12 6-9-12 14-2-8 7-4-12 -0-10-8 0-10-8 6-9-12 6-9-12 14-2-8 7-4-12 1-5-910-11-49-1-1210-11-48.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [5:0-4-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.64 0.44 0.45 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.07 -0.13 -0.11 0.13 (loc) 6-7 6-7 10 7-8 l/defl >999 >670 n/a >623 L/d 360 240 n/a 240 PLATES MT20 Weight: 67 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-6: 2x4 SPF No.2, 2-8: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (size)8=0-3-8, 7=0-3-8, 10=0-3-0 Max Horz 8=369(LC 10) Max Uplift 8=-11(LC 6), 7=-244(LC 10), 10=-140(LC 10) Max Grav 8=276(LC 19), 7=871(LC 17), 10=259(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-285/225 BOT CHORD 7-8=-518/311 WEBS 3-7=-568/276, 2-7=-297/454, 5-10=-273/148 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-10-8 to 4-5-2, Interior(1) 4-5-2 to 13-9-4 zone; end vertical left exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 4) Bearing at joint(s) 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8 except (jt=lb) 7=244, 10=140. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss M04 Truss Type MONOPITCH Qty 6 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223599 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:21:11 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-Xkn5IIv49JLoYzVqP8d0kGAp8yOMGSd98O9fMOyWQZ6 Scale = 1:61.8 1 2 3 4 5 8 7 6 910 11 3x6 4x8 4x6 3x4 3x4 3x4 6x8 3x6 7-3-4 7-3-4 14-6-8 7-3-4 -0-10-8 0-10-8 7-3-4 7-3-4 14-6-8 7-3-4 1-5-911-1-149-1-1211-1-148.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [5:0-4-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.58 0.45 0.51 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.08 -0.14 0.16 0.03 (loc) 6-7 6-7 10 6 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 69 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-6: 2x4 SPF No.2, 2-8: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 8-8-0 oc bracing. WEBS 1 Row at midpt 3-6 REACTIONS. (size)8=0-3-8, 10=0-3-0 Max Horz 8=378(LC 10) Max Uplift 10=-262(LC 10) Max Grav 8=716(LC 17), 10=717(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-651/0, 6-9=-145/561, 5-9=-145/561, 2-8=-608/26 BOT CHORD 7-8=-452/383, 6-7=-210/543 WEBS 3-7=0/327, 3-6=-683/264, 2-7=0/384, 5-10=-735/270 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-10-8 to 4-5-2, Interior(1) 4-5-2 to 14-1-4 zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 4) Bearing at joint(s) 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 10=262. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss T01 Truss Type Common Qty 4 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223600 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:21:12 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-?xLUWdvjwdTfA640zs8FGUjz_MfO?xgJN1uCuryWQZ5 Scale = 1:51.4 1 2 3 4 5 6 7 11 10 9 812131415 4x6 3x6 3x8 3x4 3x4 3x6 6x8 5x8 3x6 11-0-0 11-0-0 22-0-0 11-0-0 -0-10-8 0-10-8 5-7-4 5-7-4 11-0-0 5-4-12 16-4-12 5-4-12 22-0-0 5-7-4 22-10-8 0-10-8 1-5-98-9-91-5-98.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.70 0.78 0.40 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.36 -0.63 0.02 0.02 (loc) 9-11 9-11 8 9 l/defl >730 >415 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 89 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 8-10: 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 2-11,6-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-9-13 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-11, 5-8 REACTIONS. (size)11=0-3-8, 8=0-3-8 Max Horz 11=-249(LC 8) Max Uplift 11=-122(LC 10), 8=-122(LC 11) Max Grav 11=1045(LC 17), 8=1045(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-380/117, 3-4=-927/211, 4-5=-927/211, 5-6=-374/120, 2-11=-384/140, 6-8=-380/141 BOT CHORD 9-11=-144/937, 8-9=-49/812 WEBS 4-9=-84/658, 3-11=-812/105, 5-8=-817/103 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-10-8 to 4-5-2, Interior(1) 4-5-2 to 5-5-14, Exterior(2R) 5-5-14 to 16-6-2, Interior(1) 16-6-2 to 17-6-14, Exterior(2E) 17-6-14 to 22-10-8 zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 11=122, 8=122. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss T02 Truss Type COMMON Qty 7 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223601 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:21:13 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-T7vsjzwLhxbWoGfDXZgUphFCsm0jkIOSchelRHyWQZ4 Scale = 1:75.4 1 2 3 4 5 6 7 8 9 10 11 19 18 17 16 15 14 13 12 20 21 22 23 3x6 4x8 3x6 3x4 3x6 3x6 3x4 4x8 2x4 2x4 4x8 3x6 3x4 5x8 3x4 5x8 3x6 6-0-0 6-0-0 12-5-12 6-5-12 21-10-4 9-4-8 28-4-0 6-5-12 34-4-0 6-0-0 -0-10-8 0-10-8 6-0-0 6-0-0 11-6-3 5-6-3 17-2-0 5-7-13 22-9-13 5-7-13 28-4-0 5-6-3 34-4-0 6-0-0 35-2-8 0-10-8 1-5-912-10-141-5-98.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [7:0-0-0,0-0-0], [10:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.44 0.71 0.82 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.33 -0.49 0.01 0.03 (loc) 15-16 15-16 12 13-15 l/defl >791 >536 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 165 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 6-16,6-15: 2x4 SPF No.2, 2-19,10-12: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-5-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-16, 5-16, 6-16, 6-15, 7-15, 9-15 REACTIONS. (size)19=0-3-8, 16=0-3-8, 12=0-3-8 Max Horz 19=-354(LC 8) Max Uplift 19=-22(LC 10), 16=-251(LC 10), 12=-132(LC 11) Max Grav 19=459(LC 23), 16=1842(LC 17), 12=994(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-360/52, 3-5=-70/297, 5-6=-19/320, 6-7=-741/317, 7-9=-728/164, 9-10=-1038/146, 2-19=-403/79, 10-12=-893/163 BOT CHORD 18-19=-338/413, 16-18=-187/377, 15-16=-73/269, 13-15=-24/746 WEBS 3-16=-492/198, 5-16=-365/252, 6-16=-994/102, 6-15=-275/1011, 7-15=-362/252, 9-15=-377/175, 10-13=0/620 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-10-8 to 4-5-2, Interior(1) 4-5-2 to 11-10-6, Exterior(2R) 11-10-6 to 22-5-10, Interior(1) 22-5-10 to 29-10-14, Exterior(2E) 29-10-14 to 35-2-8 zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 19 except (jt=lb) 16=251, 12=132. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss T03 Truss Type COMMON Qty 4 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223602 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:21:14 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-xJTExJxzSEjMPQEP4GBjLvoK29LPTmobqLNJzjyWQZ3 Scale = 1:51.7 1 2 3 4 5 9 8 7 6 10 11 12 13 3x4 4x6 2x4 3x6 3x4 3x8 3x4 4x8 3x6 9-9-0 9-9-0 18-8-0 8-11-0 4-7-8 4-7-8 9-9-0 5-1-8 14-10-8 5-1-8 18-8-0 3-9-8 2-3-88-9-82-10-28.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.60 0.81 0.74 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.29 -0.48 0.01 0.01 (loc) 7-9 7-9 6 7 l/defl >767 >460 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 79 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-9,5-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)9=0-3-8, 6=0-3-8 Max Horz 9=248(LC 7) Max Uplift 9=-82(LC 10), 6=-79(LC 11) Max Grav 9=826(LC 17), 6=801(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-684/182, 3-4=-682/181 BOT CHORD 7-9=-119/659, 6-7=-72/475 WEBS 3-7=-58/402, 2-9=-692/95, 4-6=-742/108 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 5-5-6, Exterior(2R) 5-5-6 to 13-2-10, Exterior(2E) 13-2-10 to 18-6-4 zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 6. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss T04 Truss Type COMMON Qty 4 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223603 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:21:15 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-PW0c8fybDYrD1apbe_iyu6LU_Zf1CBOl3?7sV9yWQZ2 Scale = 1:51.7 1 2 3 4 5 9 8 7 6 10 11 12 3x4 4x6 2x4 3x8 3x4 3x8 3x4 5x8 3x6 10-5-8 10-5-8 19-4-8 8-11-0 5-4-0 5-4-0 10-5-8 5-1-8 15-7-0 5-1-8 19-4-8 3-9-8 1-9-138-9-82-10-28.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.65 0.91 0.85 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.38 -0.64 0.02 0.02 (loc) 7-9 7-9 6 7 l/defl >604 >358 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 81 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-9,5-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. REACTIONS. (size)9=Mechanical, 6=0-3-8 Max Horz 9=173(LC 7) Max Uplift 9=-83(LC 10), 6=-77(LC 11) Max Grav 9=866(LC 17), 6=836(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-259/77, 2-3=-723/176, 3-4=-726/175 BOT CHORD 7-9=-181/725, 6-7=-73/483 WEBS 3-7=-54/455, 2-9=-679/127, 4-6=-776/139 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 5-2-11, Exterior(2R) 5-2-11 to 13-11-2, Exterior(2E) 13-11-2 to 19-2-12 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss T05 Truss Type Common Qty 1 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223604 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:21:15 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-PW0c8fybDYrD1apbe_iyu6LYdZkoCGDl3?7sV9yWQZ2 Scale = 1:51.7 1 2 3 4 5 10 9 8 7 6 11 12 3x6 4x6 2x4 2x4 3x6 3x6 3x6 3x8 3x4 3x8 2-3-8 2-3-8 9-9-0 7-5-8 18-8-0 8-11-0 4-7-8 4-7-8 9-9-0 5-1-8 14-10-8 5-1-8 18-8-0 3-9-8 2-3-88-9-82-10-28.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.42 0.61 0.54 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.15 -0.30 0.01 0.01 (loc) 6-7 6-7 6 7 l/defl >999 >647 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 81 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-10,5-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)9=0-3-8, 6=0-3-8 Max Horz 9=162(LC 7) Max Uplift 9=-88(LC 10), 6=-67(LC 11) Max Grav 9=836(LC 1), 6=634(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-475/157, 3-4=-475/156 BOT CHORD 7-9=-122/313, 6-7=-61/355 WEBS 2-9=-719/141, 4-6=-565/124 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 5-5-6, Exterior(2R) 5-5-6 to 13-2-10, Exterior(2E) 13-2-10 to 18-6-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 6. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss T06 Truss Type Common Qty 1 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223605 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:21:16 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-tia_M?yD_sz4fkOnChDBRKtjuz4XxjsuIfsQ1cyWQZ1 Scale = 1:51.4 1 2 3 4 5 10 9 8 7 6 11 12 3x6 4x6 2x4 2x4 3x6 3x6 3x4 3x8 3x4 3x8 2-3-8 2-3-8 2-5-4 0-1-12 9-9-0 7-3-12 18-5-0 8-8-0 4-7-8 4-7-8 9-9-0 5-1-8 14-10-8 5-1-8 18-5-0 3-6-8 2-3-88-9-83-0-28.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.39 0.58 0.51 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.13 -0.27 0.01 0.01 (loc) 6-7 6-7 6 7 l/defl >999 >717 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 80 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-10,5-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)9=0-3-8, 6=Mechanical Max Horz 9=162(LC 7) Max Uplift 9=-86(LC 10), 6=-65(LC 11) Max Grav 9=827(LC 1), 6=623(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-466/153, 3-4=-463/153 BOT CHORD 7-9=-127/303, 6-7=-59/331 WEBS 2-9=-707/140, 4-6=-559/125 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 5-5-6, Exterior(2R) 5-5-6 to 12-11-10, Exterior(2E) 12-11-10 to 18-3-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss T07 Truss Type Common Qty 6 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223606 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:21:17 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-Lu8NZLzrl95xGuz_mPkQzXQo2NQ?gEi2WJcza2yWQZ0 Scale = 1:45.8 1 2 3 4 8 7 6 5 9 10 2x4 4x6 6x6 3x6 3x6 3x8 2x4 3x8 8-11-4 8-11-4 16-4-8 7-5-4 2-9-0 2-9-0 8-11-4 6-2-4 16-4-8 7-5-4 1-10-27-9-102-10-28.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.81 0.63 0.28 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.14 -0.28 0.01 0.01 (loc) 6-8 6-8 5 6-8 l/defl >999 >679 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 66 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-8,4-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-8-15 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)8=0-3-8, 5=0-3-8 Max Horz 8=224(LC 7) Max Uplift 8=-73(LC 10), 5=-68(LC 11) Max Grav 8=643(LC 1), 5=643(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-565/154, 3-4=-579/145, 4-5=-584/126 BOT CHORD 6-8=-154/529 WEBS 3-6=0/266, 2-8=-664/195, 4-6=-21/375 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 5-5-6, Exterior(2R) 5-5-6 to 10-11-2, Exterior(2E) 10-11-2 to 16-2-12 zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 5. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss T08 Truss Type COMMON Qty 5 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223607 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:21:18 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-p4ilmh_TWTDou1XAJ6FfWkzzqnp9PkPBlzLW6UyWQZ? Scale = 1:45.0 1 2 3 4 5 8 7 6 9 10 4x6 3x4 3x4 3x8 8x8 8x8 7-2-8 7-2-8 14-5-0 7-2-8 -0-10-8 0-10-8 7-2-8 7-2-8 14-5-0 7-2-8 15-3-8 0-10-8 1-6-107-6-111-6-1010.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [4:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.81 0.37 0.13 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.05 -0.10 0.00 -0.00 (loc) 6-7 6-7 6 6-7 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 60 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-8,4-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)8=0-3-8, 6=0-3-8 Max Horz 8=222(LC 9) Max Uplift 8=-76(LC 10), 6=-76(LC 11) Max Grav 8=626(LC 1), 6=626(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-541/155, 3-4=-541/155, 2-8=-563/185, 4-6=-563/185 BOT CHORD 7-8=-256/368 WEBS 3-7=0/271, 2-7=-96/255, 4-7=-100/256 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-10-8 to 4-5-2, Exterior(2R) 4-5-2 to 9-11-14, Exterior(2E) 9-11-14 to 15-3-8 zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 3) The Fabrication Tolerance at joint 2 = 12%, joint 4 = 12% 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss TG01 Truss Type Flat Girder Qty 1 Ply 2 Old Town - 59 Sunrise Job Reference (optional) I48223608 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:21:19 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-IHG7_1?6HnMfWB6Mtqmu2yVImA7F8CdK_d54exyWQZ_ Scale = 1:17.112 4 3 5 6 2x4 3x4 2x4 4x6 4-5-0 4-5-0 4-5-0 4-5-0 2-10-2LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.15 0.51 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.02 -0.05 0.00 0.02 (loc) 3-4 3-4 3 3-4 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 43 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD 2-0-0 oc purlins: 1-2, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=0-3-8, 3=0-3-8 Max Uplift 4=-97(LC 4), 3=-116(LC 4) Max Grav 4=686(LC 1), 3=861(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone; Lumber DOL=1.33 plate grip DOL=1.33 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb) 3=116. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 603 lb down and 85 lb up at 1-11-4, and 613 lb down and 78 lb up at 3-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 3-4=-20 Concentrated Loads (lb) Vert: 5=-603(F) 6=-613(F) October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss TG02 Truss Type Common Girder Qty 1 Ply 2 Old Town - 59 Sunrise Job Reference (optional) I48223609 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:21:20 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-mTqVBN0k24UW7LhZRXI7b92MhaTXtWGUDHqd9NyWQYz Scale = 1:45.0 1 2 3 4 5 8 7 69101112 3x4 4x6 3x4 6x8 4x6 4x6 8x8 8x8 7-2-8 7-2-8 14-5-0 7-2-8 3-9-0 3-9-0 7-2-8 3-5-8 10-8-0 3-5-8 14-5-0 3-9-0 1-6-107-6-111-6-1010.00 12 Plate Offsets (X,Y)-- [7:0-4-0,0-4-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.59 0.51 0.62 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.10 -0.18 0.01 0.07 (loc) 6-7 6-7 6 6-7 l/defl >999 >957 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 168 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF-S Stud *Except* 1-8,5-6: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)8=0-3-8, 6=0-3-8 Max Horz 8=197(LC 5) Max Uplift 8=-185(LC 8), 6=-304(LC 9) Max Grav 8=1620(LC 2), 6=2630(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1963/320, 3-4=-1963/320, 4-5=-767/153, 5-6=-554/131 BOT CHORD 7-8=-204/1332, 6-7=-148/1391 WEBS 3-7=-315/2253, 4-7=-150/273, 2-7=-153/328, 2-8=-1958/225, 4-6=-1329/151 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 8=185, 6=304. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 815 lb down and 103 lb up at 6-4-12, 815 lb down and 103 lb up at 8-4-12, and 815 lb down and 103 lb up at 10-4-12, and 815 lb down and 103 lb up at 12-4-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Continued on page 2 October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss TG02 Truss Type Common Girder Qty 1 Ply 2 Old Town - 59 Sunrise Job Reference (optional) I48223609 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:21:20 2021 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-mTqVBN0k24UW7LhZRXI7b92MhaTXtWGUDHqd9NyWQYz LOAD CASE(S) Standard Uniform Loads (plf) Vert: 1-3=-60, 3-5=-60, 6-8=-20 Concentrated Loads (lb) Vert: 9=-743(B) 10=-743(B) 11=-743(B) 12=-743(B) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss V01 Truss Type Valley Qty 1 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223610 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:21:21 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-EfOtPi0MpOcNlVGl?FpM8NbWR_t4c5gdRxaBipyWQYy Scale = 1:28.5 1 2 3 43x6 4x6 3x6 2x4 0-0-5 0-0-5 10-8-1 10-7-13 5-4-1 5-4-1 10-8-1 5-4-1 0-0-44-5-60-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.66 0.23 0.09 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 28 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=10-7-8, 3=10-7-8, 4=10-7-8 Max Horz 1=-105(LC 6) Max Uplift 1=-35(LC 10), 3=-46(LC 11), 4=-14(LC 10) Max Grav 1=208(LC 1), 3=208(LC 1), 4=373(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss V02 Truss Type Valley Qty 1 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223611 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:21:22 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-isyGc21_aikENfrxYyKbga7nVODhLYnngbJkEFyWQYx Scale = 1:21.5 1 2 3 43x4 4x6 3x4 2x4 0-0-5 0-0-5 7-5-11 7-5-6 3-8-14 3-8-14 7-5-11 3-8-14 0-0-43-1-60-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.32 0.21 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=7-5-1, 3=7-5-1, 4=7-5-1 Max Horz 1=71(LC 9) Max Uplift 1=-25(LC 11), 3=-34(LC 11), 4=-9(LC 10) Max Grav 1=140(LC 1), 3=140(LC 1), 4=254(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss V03 Truss Type Valley Qty 1 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223612 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:21:22 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-isyGc21_aikENfrxYyKbga7p3OG2LY8ngbJkEFyWQYx Scale = 1:11.7 1 2 3 4 2x4 4x6 2x4 2x4 0-0-5 0-0-5 4-3-5 4-3-0 2-1-10 2-1-10 4-3-5 2-1-10 0-0-41-9-60-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.15 0.06 0.01 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-3-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=4-2-11, 3=4-2-11, 4=4-2-11 Max Horz 1=-37(LC 6) Max Uplift 1=-18(LC 11), 3=-22(LC 11) Max Grav 1=79(LC 1), 3=79(LC 1), 4=120(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss V04 Truss Type Valley Qty 2 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223613 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:21:23 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-A2VeqO2cL?s5_pQ86frqDogw4oZ_4yywvF3HmiyWQYw Scale = 1:53.9 1 2 3 4 7 6 583x4 2x4 2x4 2x4 2x4 2x4 2x4 13-6-11 13-6-11 0-0-49-0-88.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.33 0.20 0.23 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 47 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-5 REACTIONS.All bearings 13-6-5. (lb) - Max Horz 1=345(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 5 except 6=-133(LC 10), 7=-178(LC 10) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 6=469(LC 17), 7=549(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-356/242 WEBS 3-6=-263/186, 2-7=-337/228 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-5-12 to 5-6-11, Interior(1) 5-6-11 to 8-1-14, Exterior(2E) 8-1-14 to 13-5-7 zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5 except (jt=lb) 6=133, 7=178. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss V05 Truss Type Valley Qty 2 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223614 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:21:24 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-eE301k3E6J_ycy?KgNM3l?D7fBvwpQP48vorI8yWQYv Scale = 1:46.1 1 2 3 4 7 6 53x4 2x4 2x4 2x4 2x4 2x4 2x4 11-6-11 11-6-11 0-0-47-8-88.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.21 0.16 0.16 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 39 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 11-6-5. (lb) - Max Horz 1=292(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 5 except 6=-148(LC 10), 7=-129(LC 10) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 6=481(LC 17), 7=379(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-323/170 WEBS 3-6=-290/207 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5 except (jt=lb) 6=148, 7=129. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss V06 Truss Type Valley Qty 2 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223615 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:21:25 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-6RdOE43ssd6pE6aWE4tIIDlGUbEGYuSDMZYOrayWQYu Scale = 1:39.8 1 2 3 5 463x4 2x4 2x4 2x4 2x4 9-6-11 9-6-11 0-0-46-4-88.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.33 0.22 0.11 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 31 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=9-6-5, 4=9-6-5, 5=9-6-5 Max Horz 1=239(LC 10) Max Uplift 4=-44(LC 10), 5=-190(LC 10) Max Grav 1=193(LC 19), 4=156(LC 17), 5=592(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-254/147 WEBS 2-5=-362/280 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb) 5=190. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss V07 Truss Type Valley Qty 2 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223616 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:21:25 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-6RdOE43ssd6pE6aWE4tIIDlIdbEBYuyDMZYOrayWQYu Scale = 1:31.5 1 2 3 5 42x4 2x4 2x4 2x4 2x4 7-6-11 7-6-11 0-0-45-0-88.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.19 0.22 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 22 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=7-6-5, 4=7-6-5, 5=7-6-5 Max Horz 1=186(LC 10) Max Uplift 4=-54(LC 10), 5=-145(LC 10) Max Grav 1=108(LC 19), 4=136(LC 17), 5=368(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-281/250 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb) 5=145. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss V08 Truss Type Valley Qty 2 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223617 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:21:26 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-adBmSQ4VdwEgrG9inoOXqQIIb?V3HMMMbDHxN1yWQYt Scale = 1:23.3 1 2 32x4 2x4 2x4 5-6-11 5-6-11 0-0-43-8-88.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.95 0.56 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-6-11 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=5-6-5, 3=5-6-5 Max Horz 1=132(LC 10) Max Uplift 3=-84(LC 10) Max Grav 1=199(LC 1), 3=213(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss V09 Truss Type Valley Qty 2 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223618 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:21:26 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-adBmSQ4VdwEgrG9inoOXqQIRH?b_HMMMbDHxN1yWQYt Scale = 1:14.8 1 2 3 2x4 2x4 2x4 3-6-11 3-6-11 0-0-42-4-88.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.33 0.19 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-6-11 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=3-6-5, 3=3-6-5 Max Horz 1=79(LC 10) Max Uplift 3=-50(LC 10) Max Grav 1=119(LC 1), 3=127(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 6,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job J21105943 Truss V10 Truss Type Valley Qty 2 Ply 1 Old Town - 59 Sunrise Job Reference (optional) I48223619 8.430 s Aug 16 2021 MiTek Industries, Inc. Tue Oct 5 15:21:27 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:YMR9tkxfWOb?4FSdPy6y9PzwQBq-3pl9fm57OEMWTQjvLVwmNerhdPzr0pcWqt1VvTyWQYs Scale: 1.5"=1' 1 2 3 2x4 5x6 1-6-11 1-6-11 0-0-41-0-88.00 12 Plate Offsets (X,Y)-- [2:0-5-7,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.03 0.02 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 3 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-6-11 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=1-6-5, 3=1-6-5 Max Horz 1=26(LC 10) Max Uplift 3=-16(LC 10) Max Grav 1=39(LC 1), 3=42(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.98; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. October 6,2021 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.21.The design does not take into account any dynamic or other loads other than those expressly stated.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3- 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths