HomeMy WebLinkAboutE-102 = Lighting PlanTBW24/72 TBW24/36 TBW24/72TBW24/36 TBW24/72 TBW24/36 TBW24/72 TBW24/36
TBW24/72 TBW24/36
TBW24/72 TBW24/36
30/72E30/72E30/72E30/72E30/60E
30/60E30/60E
30/60E30/72E30/72EC1
BF
C1
BF
C1
BF
C1
BF
C1
BF
C1
BF
24/84 24/9636/7224/84
24/9636/7224/84 24/9636/7224/84 24/9636/7220/6620/6620/6620/6624/84
24/9636/7224/84 24/9636/72UP
UP
FIRST FLOOR
EL: -2' - 0"
FIRST FLOOR
EL: 0' - 0"2
3
2
3
2
3
2
3
2
3
2
3 OSOSOSOSOSOSDOS OSOSD D
OS
OSPP
OS
OS
OS1023 OS
OS
OSPP
SW2
OS
PP
PP
PP
OS
OS
PP
PP
PP
OS
OS
RAMP
L1
1ELP-2#7
L1
1ELP-2#7
L1
1ELP-2#7
L1
1ELP-2#7L1
1ELP-2#7
L1
1ELP-2#7
L1
1ELP-2#13
L1
1ELP-2#13
L1
1ELP-2#13
L1
1ELP-2#13 L1
1ELP-2#13
L1
1ELP-2#13
L1
1ELP-2#13 L1
1ELP-2#13
L1
1ELP-2#13
L1
1ELP-2#13
L1
1ELP-2#11 L1L1
1ELP-2#11L1L1
1ELP-2#11
L1
1ELP-2#11L1L1
1ELP-2#11
L1
1ELP-2#11
L1
1ELP-2#11
L1
1ELP-2#11
L1
1ELP-2#11 L1 L1
1ELP-2#11
1ERP-21ELP-2
TX-1
01
01
01
L2
L2
L2
03
02
X1
EXL3
EXL3
EXL3
EXL3
EXL3
EXL3
EXL4
1ELP-2#9
EXL4
1ELP-2#9
EXL4
1ELP-2#9
EXL4
1ELP-2#9
EXL4
1ELP-2#9
EXL4
1ELP-2#9
EXL4
1ELP-2#9
EXL4
1ELP-2#9
EXL4
1ELP-2#9
EXL4
1ELP-2#9
EXL4
1ELP-2#9
EXL4
1ELP-2#9
L5
L5 L5
L5 L5
L5L5
L4
1ELP-2#9 L4
1ELP-2#9
L4
1ELP-2#9 L4
1ELP-2#9
L4
1ELP-2#9
L4
1ELP-2#9
L4
1ELP-2#9
L4
1ELP-2#9
L4
1ELP-2#9
L4
1ELP-2#9
02
02
02
02
L6
1ELP-2#13
EXL3
L2
X1 02
02
X1
01
04
04
ETS
ETS
ETS
ETS
ETS
1/8" = 1'-0" 1 LIGHTING PLAN
LIGHTING - GENERAL NOTES
A REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT
PLACEMENT OF ALL LIGHTING FIXTURES. VERIFY CEILING CONSTRUCTION
AND PROVIDE LIGHTING FIXTURES WITH ALL NECESSARY MOUNTING
HARDWARE.
B RECESSED FIXTURES SHALL BE PROVIDED WITH STRUCTURAL SUPPORTS,
AS REQUIRED BY THE AHJ. IF REQUIRED, REFER TO DETAIL SHEETS FOR
INSTALLATION REQUIREMENTS.
C RECESSED FIXTURES LOCATED IN A FIRE RATED CEILING SHALL BE
PROVIDED WITH A FIVE SIDED ENCLOSURE, WITH A FIRE RATING GREATER
THAN OR EQUAL TO THE RATING OF THE CEILING ASSEMBLY. THE
ENCLOSURE SHALL MEET ALL NEC AND MANUFACTURER REQUIRED
CLEARANCES.
D ALL WORK SHALL BE INSTALLED PARALLEL AND PERPENDICULAR TO THE
BUILDING STRUCTURE, WHERE EXPOSED. ALL EXPOSED WIRING SHALL BE
IN CONDUIT, UNLESS OTHERWISE APPROVED BY OWNER.
E ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE PROPERLY
SEALED WITH AN APPROVED FIRE STOP SYSTEM GREATER THAN OR EQUAL
TO THE FIRE RATING OF THE WALL ASSEMBLY.
F RACEWAYS SHALL NOT BE PERMITTED TO SERVE AS AN EGC.
G ALL EXTERIOR PENETRATIONS, AND / OR PENETRATIONS THROUGH A
THERMAL ENVELOPE, SHALL BE SEALED WITH AN APPROVED SEALANT TO
PREVENT THE ENTRANCE OF AIR OR WATER. (NEC ART. 300.7(A))
H EMERGENCY LIGHTING WITH INDIVIDUAL BATTERY BACKUP SHALL BE FED
FROM THE SAME CIRCUIT AS THE LIGHTING IN THE AREA WHICH IT SERVES.
(NEC ART. 700.12(F))
No. 1 2000739
STATE OF
JA R E D RICHEY
RE G I STERED
INDIAN APROFESSIONAL E N GINEER
DRAWING No. :PROJECT NAME :DRAWING TITLE :ORIGINAL DRAWING IS : 30"x42"
DEEM MECHANICAL & ELECTRICAL, LLC.
RESERVES THE RIGHT TO REVISE THE
DESIGN OF THE ELECTRICAL AND/OR
MECHANICAL SYSTEMS PROVIDING THE
CHANGES MEET THE DESIGN/BUILD
SPECIFICATIONS FOR THIS PROJECT.
1
A
2 3 4 5 6
1 2 3 4 5 6
B
C
D
E
A
B
C
D
E
DRAWN BY :
DATE :
SCALE :
PROJECT No. : 1 /1 7/2022 1 0:1 2:54 AM
1 /8" = 1 '-0"410 MONON TRAIL, CARMEL, IN 46032LIGHTING PLANMERCHANTS CORPORATECENTER OFFICE ANDSOCIAL HUB TIE-102
JLS
1 2/1 3/2021
21 083
SHEET E-102 - KEYED NOTES
01 RELOCATE DEMOED 'L3' TYPE LIGHT FIXTURES IN THE AREA.
02 WIRE NEW EXIT/EMERGENCY LIGHTING TO THE CLOSEST EXISTING
EMERGENCY LIGHTING CIRCUIT 1ELP-3.
03 RELOCATE DEMOED LIGHT FIXTURES IN THE AREA
04 SEE DETAILS FOR LIGHTING CONTROLS IN THIS AREA ON SHEET E-701.
N REVISION SCHEDULENo. DESCRIPTION DATE1 STATESUBMISSIONS01/17/202201/31/22