HomeMy WebLinkAboutA200.4 - SOUTH 4TH LEVEL FLATSDN
DN
SW EGRESS -
LEVEL 4
SE EGRESS -
LEVEL 4
ELEVATOR
A3-2
1
A3-1
1
A3-12 4 1/4"BEDROOM 1
ENSUITE BATH
CL
HALL
BEDROOM 2
LAUNDRY
BATH
CL
SOUTH CORRIDOR
-LEVEL 4
UNIT 6 -ENT.
DINING KITCHEN
LIVING ROOMBALCONY
BALCONY
LIVING ROOM
DINING
HALL
LAUNDRY ENSUITE BATH
BEDROOM 1 WIC BEDROOM 2 BATH BEDROOM 3
CL
KITCHEN
UNIT 5 -ENT.
CL
L.
L.
WIC
L.
MECH
11' - 2 1/4"8' - 1"PANTRY
CL
MECH
1
A5-0EG-1EG-1J1
E1J1
D1 H1 Q1 Q1
H1
D1
D1
A1A1
B1
D1
F1
E1
C2
H1
E-2
03 0110
01 120907 11071204
0309
04031106
12C1
E-20202
09
07
02
1212 030202
DW
DW
SHOWER
SHOWER
TOILETTOILET
CHASE
** SEE THIRD FLOOR PLAN
NOTES AND DIMENSIONS -
UNLESS OTHERWISE NOTED**
** SEE THIRD FLOOR PLAN
NOTES AND DIMENSIONS -
UNLESS OTHERWISE NOTED**
C3
6
A4-3
5
A4-3
1
A4-3
1
A4-3
3
A4-3
5
A4-3
1
A5-1
3
A4-3
2
A5-0
2
A4-3
081
1' - 2"12PANTRY
CL
UP
7
A4-3
5
5
A4-3
4
A4-3
59
59
59
59
PLAN GENERAL NOTES
1. DO NOT SCALE DRAWINGS.
2. HINGE SIDE OF DOOR SHALL BE 5" OFF THE FACE OF
ADJACENT WALL, UNLESS NOTED OTHERWISE.
3. LOCATIONS OF ANY AND ALL CHASES, BULKHEADS, OR
DROP CEILINGS NECESSARY FOR THE RUNNING OF
DUCTWORK, PLUMBING, OR ELECTRICAL LINES TO BE
DETERMINED ON SITE WITH INPUT FROM THE ARCHITECT
AND MAY NOT BE SHOWN ON DRAWINGS.
4. PROVIDE LINTELS AND HEADERS AS REQUIRED, SEE
STRUCTURAL DRAWINGS.
ALL ANGLES AT 45 DEGREE INCREMENTS UNLESS NOTED
OTHERWISE.
5. SEE PLUMBING DRAWINGS FOR LOCATIONS OF FLOOR
DRAINS.
6. ALL RESIDENTIAL UNIT INTERIOR WALLS ARE TYPE 'A1'
UNLESS NOTED OTHERWISE.
7. PROVIDE DRYER VENT BOXES AT ALL DRYER LOCATIONS.
8. SEE SHEET T1-5 FOR SHEAR WALL AND BRACING SCHEDULE.
DATE
155 EAST MARKET STREETSECOND FLOOR, SUITE 200
INDIANAPOLIS, INDIANA 46204
T 317.721.2724
ROTTMANNCOLLIER.COM
SCOPE DOCUMENT
THESE DOCUMENTS INDICATE THE GENERAL
SCOPE OF THE PROJECT IN TERMS OFARCHITECTURAL DESIGN CONCEPT, DIMENSIONS
OF THE BUILDING, MAJOR ARCHITECTURALELEMENTS AND TYPE OF STRUCTURAL,
MECHANICAL AND ELECTRICAL SYSTEMS. THE
DRAWINGS DO NOT CECESSARILY INDICATE OR
DESCRIBE ALL WORK REQUIRED FOR FULLPERFORMANCE AND COMPLETION OF THE
REQUIREMENTS OF THE CONTRACT. ON THE
BASIS OF THE GENERAL SCOPE INDIACATED OR
DESCRIBED, TRADE CONTRACTOR SHALL
FURNISH ALL ITEMS REQUIRED FOR PROPER
EXECUTION AND COMPLETION OF THE WORK
SHEET
PROJECT NO.
REVISIONSMÉLANGE FLATSA NEW MULTIFAMILY RESIDENTIALBLOCK DEVELOPMENTFIREHOUSE DEVELOPMENTCARMEL, INDIANA 4603203-05-2021 OWNER REVIEW SET
08-16-2021 CONSTRUCTION SET
11-01-2021 ADDENDUM 1
A2-4
SOUTH -4TH LEVEL
FLATS
03-05-2021
19112
1/4" = 1'-0" 1 SOUTH -4TH LEVEL FLATS
PLAN KEYNOTES
1 SLOPE GARAGE FLOOR TOWARD GARAGE DOOR - MIN. 1/10" PER FOOT
2 CONCRETE DOES NOT SLOPE IN THIS AREA
3 DOOR TRANSITION TO MEET ADA REQ.
4 FLOOR FINISH CHANGE - CENTER AT DOOR PANEL
5 METAL HANDRAIL ON BOTH SIDES OF STAIRS AT 36" ABOVE NOSINGS EXTEND 1'-0"
BEYOND TOP AND BOTTOM RISER. PROVIDE CONTINUOUS BLOCKING IN WALL. RETURN
ENDS TO WALL, POST, OR FLOOR. PAINT
6 INSTALL LABEL ON DRYER VENT BOX LISTING EQUIVALENT DRYER DUCT LENGTH.
7 FOUR (4) PANTRY SHELVE - 16" DEEP, SEE DETAIL
8 FOUR (4) LINEN SHELVES - 12" DEEP, SEE DETAIL
9 LAUNDRY SHELF ABOVE, SEE DETAIL.
10 DOUBLE (2) RODS AND SHELVES
11 SINGLE (1) ROD AND SHELF
12 60" FIBERGLASS TUB BASE W/ TILE WALL SURROUND. INSTALL SCHLUTER-KERDI
SYSTEM BEHIND TILE.
13 SHOWER BASE WITH TILE SURROUND AND FRAMELESS GLASS ENCLOSURE. INSTALL
SCHLUTER-KERDI SYSTEM BEHIND TILE.
14 42" TALL WALL WITH STONE TOP AND GLASS ABOVE TO 7'-0" A.F.F.
15 STANDARD SHOWER HEAD PER OWNER SPEC
16 PROVIDE TWO (2) SOLID SURFACE CORNER SHELVES AT 48" AND 60" A.F.F.
17 SINK LOCATION TO ALLOW 2'-0" MINIMUM CLEARANCE BETWEEN CENTERLINE OF SINK
AND WALL
18 COORDINATE WITH OWNER ALL FLOORING INSTALLATION LOCATIONS, IN-WALL
BLOCKING FOR VANITY MOUNTING, AND WATER SUPPLY AND DRAIN LINE LOCATIONS,
BASED ON TYPE OF VANITY SELECTED.
19 NOT USED
20 CHASE - SEE ASSEMBLY DETAIL M1 T1-6
21 POSITION ISLAND SUCH THAT CENTERLINE OF SINK IS ALIGNED WITH THE CENTERLINE
OF THE RANGE.
22 OPTIONAL BEVERAGE BAR - SEE DETAIL 5 - SHEET A2-11 PLAN OPTIONS
23 THIS WINDOW SHALL BE SAFETY TEMPERED GLAZING AT THIS LOCATION ONLY
24 NOT USED
25 FULL HEIGHT FINISHED END PANEL
26 FULL HEIGHT CABINET
27 DECORATIVE BULKHEAD - SEE T1-3 DETAIL 10
28 ALIGN EDGE OF WINDOW WITH EDGE OF WINDOW BELOW - SEE ELEVATIONS
29 ALIGN WALL FRAMING WITH ADJACENT PARALLEL WALL
30 WALL FRAMING DOES NOT ALIGN - REFER TO WALL TYPES FOR WALL FINISH
THICKNESSES
31 WINDOW TO ALIGN WITH WINDOW ON FLOOR BELOW - SEE ELEVATIONS
32 ALIGN EDGE OF OPENING WITH OPENING BELOW - SEE ELEVATIONS
33 NOT USED
34 DECORATIVE CASEWORK COLUMN - ALIGN AS SHOWN
35 STRUCTURAL COLUMN - WRAP W/ CASEWORK
36 METAL BALCONY GUARDRAIL, SEE EXTERIOR ELEVATIONS AND WALL SECTIONS FOR
DETAILS.
37 SHEAR WALL ALIGN TO WALL BELOW - SEE STRUCTURAL
38 ALIGN WALL WITH EXTERIOR WALL CORNER
39 2X2 WITH GYP. WALL COVERING - SEE WALL TYPE B1 SHEET T1-4
40 2X4 WITH GYP. WALL COVERING - SEE WALL TYPE B2 SHEET T1-4
41 GYP. APPLIED DIRECTLY TO CMU WALL CONSTRUCTION
42 3/4" PLYWOOD SEPARATION W/ 5/8" GYP BOTH SIDES - UPPER TRIANGLE OF
STAIRCASE ONLY
43 ADA COMPLIANT RAIN CUT
44 PRE-FABRICATED MAILBOX UNITS - SEE INTERIOR ELEVATIONS
45 PRE MANUFACTURED DOG WASH - SEE OWNER PROVIDED SHOP DRAWINGS
46 NORTH BUILDING SPRINKLER DRAIN DOWN VALVE ABOVE JANITOR MOP SINK
47 SOUTH BUILDING SPRINKLER DRAIN DOWN VALVE ABOVE - PROVIDE DRAIN TO
EXTERIOR AND 2'-0" X 2'-0" MIN. CLEAR FLOOR
48 22" X 36" RATED ATTIC ACCESS DOOR SEE DETAIL
49 MECHANICAL CHASE ABOVE PROVIDE RATED ACCESS DOOR AS REQUIRED BY
MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE SPRINKLER SPECIFICATIONS
50 MECHANICAL BULKHEAD - V.I.F. REQUIRED HEIGHT AND STOREFRONT SYSTEM HEIGHT
BELOW
51 CENTER SINK ON WINDOW
52 FRAMELESS GLASS SHOWER DOOR AND ENCLOSURE UP TO 7'-0" A.F.F. (2'-4" DOOR
WIDTH)
53 OPTIONAL OPEN PANTRY WITH CABINETS - SEE DETAIL #4 - SHEET A2-11 PLAN OPTIONS
54 FOUR (4) LINEN SHELVES - 16" DEEP, SEE DETAIL
55 COUNTER MOUNTED ABOVE SIDE BY SIDE WASHER AND DRYER
56 HANDHELD SHOWER HEAD MOUNTED WITH TOP OF CONTROLS AT 48" AFF.
57 DRYWALL SCUTTLE OPENING, SEE DETAIL.
58 KNOX BOX WITH TOP MOUNTED AT 48" ABOVE SIDEWALK
59 5.5" X 22" VULCAN VENT "VE552FC" IN CEILING ABOVE
60 OPTIONAL WOW! WALL - SEE DETAIL A2-11
61 OPTIONAL BANQUETTE - SEE DETAIL A2-11
01/31/22