HomeMy WebLinkAboutA200.5 - NORTH FOUNDATION PLANFOUNDATION PLAN
GENERAL NOTES
1. DO NOT SCALE DRAWINGS.
2. ALL DIMENSIONS ARE TAKEN FROM OUT TO OUT OF STUD, UNLESS NOTED OTHERWISE. DIMENSIONS WITH
+/-ARE TO BE FIELD VERIFIED BY CONTRACTOR.
3. NOT ALL FLOOR/SLAB PENETRATIONS MAY BE SHOWN. SEE M.E.P. DRAWINGS FOR PENETRATION
LOCATIONS. CONTRACTOR SHALL VERIFY THE SIZE AND LOCATION OF ALL M.E.P REQUIREMENTS AND
CLEARANCES PRIOR TO PROCEEDING WITH THE PROJECT. PENETRATIONS THROUGH THE STRUCTURE
SHALL BE SUBJECT TO APPROVAL BY THE STRUCTURAL ENGINEER.
4. ALL ANGLES AT 45 DEGREE INCREMENTS UNLESS NOTED OTHERWISE.
5. RAKE EXCAVATED MATERIALS BACK 12" MINIMUM FROM EDGES OF ALL EXCAVATIONS TO PREVENT
LOOSE SOIL FROM FALLING BACK INTO TRENCH.
6. REFER TO SITE PLANS FOR EXTERIOR CONCRETE SIDEWALKS, STOOPS, ETC.
2
A5-0
1
A5-0
3
A4-0
2
A4-0
1
A4-0
4
A4-0
8
8
8
8
7
7
7 7 7 7
1 3
1 3
2
2
4
4
4 4 4 4
4
4
4
4
4
4
TYP 5
TYP
5
TYP.5
TYP 5
9TYP
9 TYP
9TYP
9 TYP.
6
6
6 6 6 6
10
10
16' - 0"16' - 0" 16' - 0" 8' - 0"
10
3' - 8"3' - 8"3' - 8"4' - 0"4' - 0"3' - 8"
11
118' - 0"16' - 0"+99'-2" +99'-2"+99'-2"
+99'-2"
+99'-2"
+99'-2"
+99'-5"
+99'-5"
+99'-5"+99'-5"+99'-5"+99'-5"
+99'-5"
+99'-5"3' - 8"3
3
10
+99'-5"
+99'-5"
+99'-5"
+99'-5"
+99'-5"
+99'-5"
12
+99'-3"
12
+99'-3"
3' - 6" 3' - 6" 11 1/4" 3' - 6"1' - 4" 7' - 3"1' - 1"
3
2
A4-0
A2-12
2
A2-12
1
TYP.
1
A4-0
TYP.
TYP.
TYP.
1
A4-0
TYP.
5
A4-0
5
A4-0 5
A4-0
12
12
FOUNDATION LEGEND
CONCRETE SLAB - NO SLOPE
CONCRETE SLAB - SLOPE
TO GARAGE DOOR
CONCRETE SLAB - 1:50 SLOPE
LOWERED FOUNDATION WALL -
STEP #1 - SEE STRUCTURAL
LOWERED FOUNDATION WALL -
STEP #2 - SEE STRUCTURAL
TOP OF FOUNDATION
WALL - SEE STRUCTURAL
CMU BLOCK WALL
DATE
155 EAST MARKET STREETSECOND FLOOR, SUITE 200
INDIANAPOLIS, INDIANA 46204
T 317.721.2724
ROTTMANNCOLLIER.COM
SCOPE DOCUMENT
THESE DOCUMENTS INDICATE THE GENERAL
SCOPE OF THE PROJECT IN TERMS OFARCHITECTURAL DESIGN CONCEPT, DIMENSIONS
OF THE BUILDING, MAJOR ARCHITECTURALELEMENTS AND TYPE OF STRUCTURAL,
MECHANICAL AND ELECTRICAL SYSTEMS. THE
DRAWINGS DO NOT CECESSARILY INDICATE OR
DESCRIBE ALL WORK REQUIRED FOR FULLPERFORMANCE AND COMPLETION OF THE
REQUIREMENTS OF THE CONTRACT. ON THE
BASIS OF THE GENERAL SCOPE INDIACATED OR
DESCRIBED, TRADE CONTRACTOR SHALL
FURNISH ALL ITEMS REQUIRED FOR PROPER
EXECUTION AND COMPLETION OF THE WORK
SHEET
PROJECT NO.
REVISIONSMÉLANGE FLATSA NEW MULTIFAMILY RESIDENTIALBLOCK DEVELOPMENTFIREHOUSE DEVELOPMENTCARMEL, INDIANA 4603203-05-2021 OWNER REVIEW SET
08-16-2021 CONSTRUCTION SET
11-01-2021 ADDENDUM 1
A2-5
NORTH FOUNDATION
PLAN
03-05-2021
19112
1/4" = 1'-0" 1 NORTH -FOUNDATION
FOUNDATION PLAN KEYNOTES
1 4" CONCRETE SLAB ON GRADE, SEE STRUCTURAL DRAWINGS
2 4" CONCRETE SLAB ON GRADE, SEE STRUCTURAL DRAWINGS
3 CONCRETE DOES NOT SLOPE IN THIS AREA
4 HOLD DOWN FOUNDATION WALL AT DOOR LOCATIONS - SEE STRUCTURAL
5 BRICK LEDGE, SEE STRUCTURAL DRAWINGS
6 GARAGE SLAB RAIN CUT
7 4" CONCRETE SLAB ON GRADE, SEE STRUCTURAL DRAWINGS
8 FIELD BLEND FLAT SLAB INTO SLOPED SLAB AT GARAGE DOOR / HALL
LOCATIONS
9 TOP OF FOUNDATION WALL - SEE STRUCTURAL DRAWINGS
10 THICKENED SLAB BELOW, SEE STRUCTURAL DRAWINGS
11 PLUMBING FIXUTURE - COORDINATE LOCATION WITH ARCHITECTURAL AND
PLUMBING PLANS
12 FLOOR DRAIN, SLOPE CONCRETE FLOOR MIN. 1/8" PER FOOT TO DRAIN
01/31/22