Loading...
HomeMy WebLinkAboutA200.10 - ATTIC AND ROOF ACCESS AND ROOF PLANSDN 1/4 : 12 1/4 : 12 1/4 : 121/4 : 12 1/4 : 12 1/4 : 12 1/4 : 12 1/4 : 12 1/4 : 121/4 : 12 1/4 : 12 1/4 : 12 1/4 : 12 1/4 : 12 1/4 : 12 1/4 : 121/4 : 12 3/8 : 12 1/4 : 12 1/4 : 12 1/4 : 12 1/4 : 12 3 : 12 1 A4-4 2 A4-4 3 A4-4 6 A4-4 5 A4-4 4 A4-4 2 A4-5 1 A4-5 1 A5-0 2 A5-0 3 A4-4 6 A4-4 5 A4-4 1 A4-5 2 A5-0 1 A5-0 1 1 1 1 1/4 : 12 1/4 : 12 1/4 : 12 1/4 : 12 33 444444 4 4 66 77 7 7 7 7 7 7 8TYP 8 TYP 8 TYP 8 TYP 11 11 11 11 11 12 TYP 12 TYP 12 TYP 12 TYP 12 TYP 12 TYP 13 TYP 1010 14 TYPTYP TYPTYP TYP TYP TYP 4 A4-4 13TYP 1/4 : 12 1/4 : 12 ROOF GENERAL NOTES 1. ALL ROOF SLOPES ARE SLOPING DOWN IN THE DIRECTION OF THE ARROWS WITH THE PITCH AS SHOWN ON ROOF PLAN. 2. PROVIDE SADDLES AS REQUIRED FOR PROPER ROOF DRAINAGE. 3. PROVIDE PVC BOOT FOR DOWNSPOUTS AT GRADE. TIE ALL DOWNSPOUTS TOGETHER BELOW GRADE AND CONNECT TO STORM SEWER SYSTEM, REFER TO CIVIL DRAWINGS. 4. VERIFY GUTTER/SCUPPER AND DOWNSPOUT LOCATIONS WITH ARCHITECT. 5. ROOF PENETRATIONS FOR MEP SYSTEMS ARE NOT SHOWN. SEE MEP DRAWINGS FOR ACTUAL LOCATIONS AND TYPES. 6. ALL NON-PREFINISHED ROOF PENETRATIONS SHALL BE PAINTED TO MATCH ROOF. 7. KEEP ALL ROOF PENETRATIONS TO A MINIMUM AND AWAY FROM PARAPET WHERE POSSIBLE. E-3 E-315 16 17 UNIT 6 ATTIC 1636 S.F. UNIT 5 ATTIC 1883 S.F. 16 16 16 17 17 17 17 UNIT 11 ATTIC 1967 S.F. UNIT 12 ATTIC 1743 S.F. EGRESS STAIRS BELOW EGRESS STAIRS BELOW ELEVATOR ELEVATOR ROOF ACCESS / EGRESS STAIRS BELOW ROOF ACCESS / EGRESS STAIRS BELOW SOUTH CORRIDOR BELOW NORTH CORRIDOR BELOW 18 18 181818 5 18 18 18 1818 3 18 17 18 1817 22 3 5 5 5 14 TYP. OF 4 14 TYP. OF 4 99 DATE 155 EAST MARKET STREETSECOND FLOOR, SUITE 200 INDIANAPOLIS, INDIANA 46204 T 317.721.2724 ROTTMANNCOLLIER.COM SCOPE DOCUMENT THESE DOCUMENTS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OFARCHITECTURAL DESIGN CONCEPT, DIMENSIONS OF THE BUILDING, MAJOR ARCHITECTURALELEMENTS AND TYPE OF STRUCTURAL, MECHANICAL AND ELECTRICAL SYSTEMS. THE DRAWINGS DO NOT CECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR FULLPERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT. ON THE BASIS OF THE GENERAL SCOPE INDIACATED OR DESCRIBED, TRADE CONTRACTOR SHALL FURNISH ALL ITEMS REQUIRED FOR PROPER EXECUTION AND COMPLETION OF THE WORK SHEET PROJECT NO. REVISIONSMÉLANGE FLATSA NEW MULTIFAMILY RESIDENTIALBLOCK DEVELOPMENTFIREHOUSE DEVELOPMENTCARMEL, INDIANA 4603203-05-2021 OWNER REVIEW SET 08-16-2021 CONSTRUCTION SET 11-01-2021 ADDENDUM 1 A2-10 ATTIC AND ROOF ACCESS AND ROOF PLANS 03-05-2021 19112 1/8" = 1'-0"1 ROOF PLAN ROOF & ATTIC KEYNOTES 1 TPO ROOF, MECHANICALLY FASTEND, LIGHT GRAY, 45 MIL. THICKNESS. INSTALL PER ROOFING MANUFACTURER'S SPECIFICATIONS, INCLUDING ALL FLASHING AND ACCESSORIES 2 EXTEND TWO-HOUR FIRE RATED SHAFT UP TO UNDERSIDE OF ROOF SHEATHING 3 TWO-HOUR FIRE-RATED BARRIER WITH 1 1/2 HOUR RATED OPENINGS AROUND STAIRS. FROM FLOOR SLAB UP TO UNDERSIDE OF ROOF / CEILING ASSEMBLY ABOVE 4 BUILT IN SCUPPER THROUGH PARAPET WALL, SEE DETAIL. 5 EXTEND FULLY INSULATED EXTERIOR WALL UP TO UNDERSIDE OF ROOF SHEATHING. 6 PREFINISHED METAL FLASHING WITH DRIP EDGE. 7 CONDUCTOR HEAD, AND 4"X5" PREFINISHED ALUMINUM RECTANGULAR DOWNSPOUT. SEE DETAIL 8 PREFINISHED METAL WALL CAP WITH SLOPED TOP AND DRIP EDGE EACH SIDE 9 RADON PIPE TERMINATED IN ATTIC. SEE DETAIL NO MITIGATION FAN NECESSARY AT THIS LOCATION 10 TPO COMPATIBLE WALKWAY PADS 11 6" BUILT-UP INSULATION PROVIDE CRICKETS AND ADDITIONAL TAPERED ROOF SLOPES WITHIN INSULATION SYSTEM 12 SLOPED BRACING AT PARAPET WALL, RUN ROOFING AND FLASHING UP TO WALL CAP. 13 CONDENSING UNITS - SEE MECHANICAL PLANS FOR LOCATIONS. PROVIDE ROOF PAD WITH VIBRATION DAMPERS. 14 ATTIC VENT. SEE FLOOR PLANS FOR MORE INFORMATION. 15 RATED ATTIC ACCESS DOOR IN CEILING - SEE DETAIL. 16 24" ATTIC ACCESS WALKWAY MADE OF 3/4" PLYWOOD - LOCATE IN MOST ACCESSIBLE AREA OF TRUSS OPENING 17 DRAFT STOP DOOR - SEE DETAIL. 18 DRAFT STOP WALL FROM TOP OF UNIT SEPARATION WALL OR FIRE BARRIER TO UNDERSIDE OF ROOF DECK ABOVE 1/8" = 1'-0"2 ATTIC AND ROOF ACCESS PLAN DOWNSPOUT CALCULATIONS 3.1 IN/HR (IPC, CHAPTER 15, APPENDIX B RATES OF RAINFALL FOR VARIOUS CITIES) 2633 S.F. MAXIMUM AREA PER DOWNSPOUT W/ 1 DOWNSPOUT BLOCKED 2633 S.F. X 144 S.I. = 379,152 S.I. 379152 S.I. X 3.1 IN. = 1,175,371 C.I. 1,175,371 C.I. / 1728 C.I. PER FT. = 680 C.F. 680 C.F. PER HR X 7.5 GAL. PER C.F. = 5,100 GAL. PER HR. 5,100 GAL. PER HR. / 60 MINUTES = 85 GAL. PER MIN. 2015 IPC 1106.3 MINIMUM VERTICAL LEADER SIZING 2"X4" = 92 GAL. PER MIN. 2 1/2" X 3" = 92 GAL. PER MIN. 4" X 5" DOWNSPOUT PROVIDED NOTES: 01/31/22